Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Method and apparatus of surface-incident, plasmon-enhanced multiple quantum well modulators and optical coupling thereon

An optical interconnect system has first and second waveguides each with wedge-shaped cross-section at a first end, disposed over an optical modulator. The optical modulator is a surface-plasmon multi quantum well (SP-MQW) modulator, the first waveguide an input waveguide and the second waveguide configured an output waveguide. In embodiments the SP-MQW modulator has multiple semiconductor layers disposed atop a lower metal layer between 10 and 300 nanometers thick and configured such that incident light is reflected at the lower metal layer unless a voltage is applied to the semiconductor layers, when incident light is coupled into a surface plasmon mode in the lower metal layer.

42 ENGINEERING↗

1.5 – 1.6 μm semiconductor lasers with an asymmetric periodic optically coupled waveguide

High-power 1.5 – 1.6-μm semiconductor lasers with an asymmetric periodic optically coupled waveguide are developed and their current – voltage, light – current, and spectral characteristics are experimentally studied. The characteristics of these lasers are compared with the characteristics of traditional lasers based on double separate-confinement heterostructures. It is shown that the developed lasers have lower divergence and almost the same threshold and power characteristics as conventional lasers with Fabry – Perot resonators. The developed lasers with a cavity length of 1.6 mm and a mesa-stripe contact width of 3 μm mounted in a housing 11 mm in diameter have a power no lower than 200 mW at a pump current not exceeding 700 mA with a divergence of 25 – 35° versus 45° typical for conventional lasers. (lasers)

36 MATERIALS SCIENCE↗

Nanophotonic quantum sensing with engineered spin-optic coupling

Nitrogen vacancy centers in diamond provide a spin-based qubit system with long coherence time even at room temperature, making them suitable ambient-condition quantum sensors for quantities including electromagnetic fields, temperature, and rotation. The optically addressable level structures of NV spins allow transduction of spin information onto light-field intensity. The sub-optimal readout fidelity of conventional fluorescence measurement remains a significant drawback for room-temperature ensemble sensing. Here, we discuss nanophotonic interfaces that provide opportunities to achieve near-unity readout fidelity based on IR absorption via resonantly enhanced spin-optic coupling. Spin-coupled resonant nanophotonic devices are projected to particularly benefit applications that utilize micro- to nanoscale sensing volume and to outperform present methods in their volume-normalized sensitivity.

42 ENGINEERING↗

Long-range optical coupling with epsilon-near-zero materials

Long-range resonant quantum tunneling of electrons happens across potential barriers when the wavefunction interferes constructively outside the barrier. Here we demonstrate an analogy in optical systems based on epsilon-near-zero materials, achieving phase-modulated, long-range optical interactions between transparent semiconducting oxide layers beyond the evanescent photonic coupling. Distinct from weak thin-film interference, intense electromagnetic fields confined within the epsilon-near-zero thin films show anti-correlated intensity oscillations as a function of interlayer separation up to hundreds of microns. The oscillatory, anti-correlated electromagnetic field intensities were probed by second harmonic generation from wedged indium tin oxide multilayers. Such a system that hosts subwavelength mode footprint and simultaneously long-range radiative coupling offers prospects for long-distance optical communication, large-scale photonic circuits, and hybrid quantum photonic systems.

Wang, Danqing [Fudan University, Shanghai (China);↗

High-temperature analysis of optical coupling using AlGaAs/GaAs LEDs for high-density integrated power modules

A low-temperature co-fired ceramic (LTCC)-based optocoupler design is demonstrated as a possible solution for optical isolation in high-density integrated power modules. The design and fabrication of LTCC based package are discussed. Commercially available aluminum gallium arsenide/gallium arsenide (AlGaAs/GaAs) double heterostructure is used both as emitter and photodetector in the proposed optocoupler. A detailed study on the electroluminescence and spectral response of the AlGaAs/GaAs structure is conducted at elevated temperatures. The material figure of merit parameter, D*, is calculated in the temperature range 77–800 K. The fabricated optocoupler is tested at elevated temperatures, and the results are presented.

42 ENGINEERING↗

From pixels to patterns: Coupling Optical Coherence Tomography and machine learning for monitoring coastal wetland root systems

Coastal wetlands are crucial in shoreline stabilization, carbon sequestration, and storm protection. Yet, due to limitations in traditional destructive sampling techniques, the belowground biomass (live root mass) and necromass (dead and decaying roots) remain difficult to assess in coastal wetlands, limiting our understanding on coastal resilience, nutrient cycling, and soil structure. This study employs Optical Coherence Tomography (OCT) as a high-resolution imaging technique to analyze root biomass and necromass in the Terrebonne Basin, Louisiana. A Random Forest (RF) model was developed to classify root health states based on OCT-derived features, achieving an accuracy of 70% in distinguishing live from dead root segments. The results demonstrate that OCT, combined with ML, offers a promising novel approach to root analysis, providing fine-scale insights into root morphology and decay patterns that are not easily captured by conventional methods. This research lays the foundation for future integration of OCT with complementary imaging modalities such as X-ray Computed Tomography (XCT) and advanced ML algorithms to enhance classification accuracy and scalability. Future work aims to expand the dataset diversity across different wetland types and apply the methodology for large-scale, repeatable assessments of root biomass turnover and accumulation, with important implications for wetland monitoring, conservation, and restoration under changing environmental conditions.

AI/ML↗

Studies of Laser-Driven Flyer Acceleration Using Optical Fiber Coupling [Book Chapter]

An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.

440600 -- Optical Instrumentation-- (1990-)↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wafer-level handle replacement

A wafer includes a number of die, with each die including electronic integrated circuits and optical devices. The wafer has a top surface and a bottom surface and a base layer. The bottom surface of the wafer corresponds to a bottom surface of the base layer. A wafer support system is attached to the top surface of the wafer. A thickness of the base layer is removed to expose a target layer within the wafer and to give the wafer a new bottom surface. A replacement handle structure is attached to the new bottom surface of the wafer. The replacement handle structure includes a first thickness region and a second thickness region. The first thickness region is positioned closest to the new bottom surface. The first thickness region is formed of an optical cladding material that mitigates optical coupling between optical devices within the die and the replacement handle structure.

Meade, Roy Edward↗

Trace Elemental Analysis of Bulk Thorium Using an Automated Separation–Inductively Coupled Plasma Optical Emission Spectroscopy Methodology

Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. Finally, while reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.

47 OTHER INSTRUMENTATION↗

Trapping light in air with membrane metasurfaces for vibrational strong coupling

Optical metasurfaces can manipulate electromagnetic waves in unprecedented ways at ultra-thin engineered interfaces. Specifically, in the mid-infrared (mid-IR) region, metasurfaces have enabled numerous biochemical sensing, spectroscopy, and vibrational strong coupling (VSC) applications via enhanced light-matter interactions in resonant cavities. However, mid-IR metasurfaces are usually fabricated on solid supporting substrates, which degrade resonance quality factors (Q) and hinder efficient sample access to the near-field electromagnetic hotspots. Besides, typical IR-transparent substrate materials with low refractive indices, such as CaF 2 , NaCl, KBr, and ZnSe, are usually either water-soluble, expensive, or not compatible with low-cost mass manufacturing processes. Here, we present novel free-standing Si-membrane mid-IR metasurfaces with strong light-trapping capabilities in accessible air voids. We employ the Brillouin zone folding technique to excite tunable, high-Q quasi-bound states in the continuum (qBIC) resonances with our highest measured Q-factor of 722. Leveraging the strong field localizations in accessible air cavities, we demonstrate VSC with multiple quantities of PMMA molecules and the qBIC modes at various detuning frequencies. Our new approach of fabricating mid-IR metasurfaces into semiconductor membranes enables scalable manufacturing of mid-IR photonic devices and provides exciting opportunities for quantum-coherent light-matter interactions, biochemical sensing, and polaritonic chemistry. The authors introduce a mid-IR metasurface fabricated by decorating a free-standing Si-membrane with air holes. The enhanced light-matter interactions in such air cavities enable vibrational strong coupling and advanced biochemical sensing.

infrared spectroscopy↗

Method and system to separate optically measured coupled parameters

A system includes a first optical sensor sensitive to both a parameter of interest, Parameter1, and at least one confounding parameter, Parameter2 and a second optical sensor sensitive only to the confounding parameter. Measurement circuitry measures M1 in response to light scattered by the first optical sensor, where M1=value of Parameter1+K*value of Parameter2. The measurement circuitry also measures M2 in response to light scattered by the second optical sensor, where M2=value of Parameter2. Compensation circuitry determines a compensation factor, K, for the confounding parameter based on measurements of M1 and M2 taken over multiple load/unload cycles or over one or more thermal cycles. The compensation factor is used to determine the parameter of interest.

Ganguli, Anurag↗

Heterogeneously integrated electro-optic modulator

In an electro-optical modulator, an electro-optical modulation layer is bonded to a cladding layer that overlies a substrate. A modulation zone waveguide is optically coupled to the electro-optical modulation layer and optically coupled to an I/O waveguiding structure embedded in the cladding layer. The I/O waveguiding structure is conformed to guide input light toward the modulation zone waveguide and to guide output light away from the modulation zone waveguide.

36 MATERIALS SCIENCE↗

Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry

The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. In this work, 17 UOC samples, 2 quality control samples, and 26 process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗