Degradation behavior of CIGS solar Cells: A parametric analysis

A parametric study of the effect of bulk and interface properties on device characteristics as a function of heat and light stress under open-circuit and short-circuit conditions is developed for Cu(In,Ga)(S,Se) 2 solar cells using SCAPS-1D simulator. The variables and interdependencies modeled include: (1) conduction band offset (CBO) between buffer and absorber; (2) buffer ionized donor density; (3) CIGS shallow acceptor density; (4) CIGS deep acceptor density; (5) CIGS shallow donor density; (6) ionized acceptor concentration in the ordered vacancy compound (OVC) CIGS/buffer interface; and (7) back contact work-function. An increase in absorber shallow acceptor or a decrease in shallow donor density results in an increase in net carrier density and open-circuit voltage (V OC ). Further, a decrease in V OC is observed with an increase in the deep acceptors or neutral midgap defects in the CIGS due to higher charge carrier recombination. A change of CBO from spike to cliff condition is a dominant mechanism of decreasing VOC with an interface defect density of 10 12 cm -2 . The minimum depletion width is found to be specifically sensitive to CBO and interface defect density. An inflection in the capacitance–voltage curves (in reverse bias) is observed with simultaneous increase in bulk deep acceptor density and shallow donor density near the back contact.

14 SOLAR ENERGY↗

Parametric analysis of anodic degradation mechanisms for fast charging lithium batteries with graphite anode

In this work, we report the impact of the temperature-driven synergistically-coupled anodic degradation mechanisms on the electrochemical performance of lithium batteries with graphite anode over multiple cycles. Temperature dependence of electrochemical reactions and damage mechanisms, such as solid electrolyte interface (SEI) growth, lithium plating/stripping, dead lithium storage/dissolution, and film cracking are incorporated into the degradation model. Results of a parametric analysis are presented, evaluating the effects of charging rates (1–6 C), operating temperatures (-15 – 45°C) and electrode design parameters, on the relative performance fade in the lithium-ion battery. Thermo-electrochemical process maps are developed to provide insights into the relationship between electrode performance and failure mechanisms. The simulation results predict a severe capacity loss due to lithium plating at low temperatures, which is further aggravated at high charging rates. A common strategy for mitigating lithium plating, through charging at high temperatures, also results in rapid capacity loss due to accelerated SEI formation. Simulation results are used to identify the combination of operating conditions and electrode design parameters that improve the electrochemical performance of the battery. These results demonstrate an opportunity to design safe and high-performance lithium-ion batteries, guided by anodic degradation models.

Battery design↗

Quantifying market volume sensitivity to material property modifications in polyhydroxybutyrate: A parametric analysis approach

Polyhydroxybutyrate (PHB), a biodegradable biopolymer, represents a promising alternative to petroleum-based thermoplastics. However, despite consistent market growth, PHB faces persistent commercialization challenges that limit widespread adoption. Existing research has focused predominantly on optimizing PHB production processes, leaving a critical gap in understanding which material property modifications would most effectively enhance market competitiveness. This study addresses this gap by systematically analyzing the relationship between polymer material properties and market performance using U.S. market data from 2008 to 2021 for 21 thermoplastic polymers across 19 material properties. We employed principal component regression to identify property modifications that could maximize market volume while reducing CO 2 emissions. Our parametric analysis revealed that two specific material properties – Hardness Shore A and Sheet Extrusion Temperature – significantly influence PHB marketability across different price points. Market simulations demonstrated that a 10% increase in Hardness Shore A could increase PHB market volume by 431.5 million kg while reducing emissions by 188.7 kg CO 2 . A similar 10% increase to Sheet Extrusion Temperature could yield a 297.5 million kg volume increase and a 99.2 kg CO 2 reduction in emissions. Critically, this approach is agnostic to the specific methods required to achieve these property changes, instead providing material scientists with quantitative, data-driven targets for R&D prioritization. Here, this framework offers a novel methodology for evaluating biopolymer competitiveness and supporting strategic decisions to accelerate PHB market adoption and contribute to decarbonization of the plastics industry.

09 BIOMASS FUELS↗

Case Studies and Parametric Analysis of Heliostat Performance With a Tradeoff-Informed Technoeconomic Analysis Metric

The Heliostat Consortium (HelioCon) was launched in 2021 to advance heliostat technology. Here this work presents a collection of baseline case studies for the technoeconomic analysis (TEA) of candidate heliostat improvements for concentrating solar power (CSP) and concentrated solar thermal (CST) systems that employ central receivers. The case studies we develop include a large-scale CSP plant, a smaller, modular CSP plant, and a small CST plant used for industrial process heat. In this work, we also propose a novel metric for TEA of a plant component technology that recasts relative changes in levelized system costs into component-specific capital cost budgets. This measure, which we refer to as the equivalent breakeven installed cost, is the maximum budget for the technology component that leads to improved levelized costs. Finally, we perform a parametric analysis to show the impact of candidate technologies on the levelized cost of heat and, by extension, equivalent breakeven installed cost.

14 SOLAR ENERGY↗

Multi-parametric analysis for mixed integer linear programming: An application to transmission upgrade and congestion management

Upgrading the capacity of existing transmission lines is essential for meeting the growing energy demands, facilitating the integration of renewable energy, and ensuring the security of the transmission system. This study focuses on the selection of lines whose capacities and by how much should be expanded from the perspective of the Independent System Operators (ISOs) to minimize the total system cost. We employ advanced multi-parametric programming and an enhanced branch-and-bound algorithm to address complex mixed-integer linear programming (MILP) problems, considering multi-period time constraints and physical limitations of generators and transmission lines. To characterize the various decisions in transmission expansion, we model the increased capacity of existing lines as parameters within a specified range. This study first relaxes the binary variables to continuous variables and applies the Lagrange method and Karush-Kuhn-Tucker (KKT) conditions to obtain optimal solutions and identify critical regions associated with active and inactive constraints. Moreover, we extend the traditional branch-and-bound (B&B) method by determining the problem’s upper and lower bounds at each node of the B&B decision tree, helping to manage computational challenges in large-scale MILP problems. Here, we compare the difference between the upper and lower bounds to obtain an approximate optimal solution within the decision-makers’ tolerable error range. In addition, the first derivative of the objective function on the parameters of each line is used to inform the selection of lines for easing congestion and maximizing social welfare. Finally, the capacity upgrades are selected by weighing the reductions in system costs against the expense of upgrading line capacities. The findings are supported by numerical simulations and provide transmission-line planners with decision-making guidance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Variable Parametric Analysis of Prototype Building Energy Performance Using Current and Future Weather Scenarios For Data-Driven Market Transformation Support

This project aimed to develop a public building simulation data set that may be used to inform building code development and guidelines for building innovation. The data set consists of several common building types and many representative locations across the United States. A parametric design of building properties was developed to create a range of building energy models that represent common building design decisions with a particular focus on fenestration options. The US Department of Energy prototype building energy models were altered according to a parametric building design and simulated using both current weather data and future weather estimates derived from global climate models. The resulting data set allows for pertinent exploration of building design parameters, including fenestration, within different environments across the United States in the broader context of climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

A Novel Framework for Parametric Analysis of Coastal Transition Zone Modeling

Abstract Vulnerability of coastal regions to extreme events motivates an operational coupled inland‐coastal modeling strategy focusing on the coastal transition zone (CTZ), an area between the coast and upland river. To tackle this challenge, we propose a top‐down framework for investigating the contribution of different processes to the hydrodynamics of CTZs with various geometrical shapes, different physical properties, and under several forcing conditions. We further propose a novel method, called tidal vanishing point (TVP), for delineating the extent of CTZs through the upland. We demonstrate the applicability of our framework over the United States East and Gulf coasts. We categorize CTZs in the region into three classes, namely, without estuary (direct river–coast connection), triangular‐, and trapezoidal‐shaped estuary. The results show that although semidiurnal tidal constituents are dominant in most cases, diurnal tidal constituents become more prevalent in the river segment as the discharge increases. Also, decreasing the bed roughness value promotes more significant changes in the results than increasing it by the same value. Additionally, the estuary promotes tidal energy attenuation and consequently decreases the reach of tidal signals through the upland. The proposed framework is generic and extensible to any coastal region.

Chegini, Taher↗

Parametric Analysis of Holdup in HEPA Filters

This technical document (TECH) contains an analysis of several conditions deemed credible for plutonium oxide buildup in high-efficiency air particulate (HEPA) filters to determine the effect of holdup inside the filter on reactivity. This document is performed in accordance with NCS-AP-005, R3 [Ref. (1)].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗