Search NASA⌕ Search

SEARCH · Search NASA

Results for “PCI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

An Integrated High-Speed Microstructural Characterization Method Using Simultaneous XRD, Stereo-DIC, and PCI

High-speed characterization of the deformation mechanisms in polycrystalline metals requires the quantification of full strain fields and local microstructural evolutions simultaneously. In this paper, we present a novel experimental method to integrate phase-contrast imaging (PCI), stereographic digital image correlation (stereo-DIC), and full-ring X-ray diffraction (XRD) to allow for the simultaneous characterization of polycrystalline metals at 1MHz or higher. A Kolsky bar was integrated into the synchrotron X-ray source in Sector 32 ID-B at the Advance Photon Source (APS) at Argonne National Laboratory. When the sample is dynamically loaded, the diagnostic methods of full-ring XRD, PCI, and stereo-DIC are properly synchronized to record the deformation behavior at both continuum and microstructural scales as a function of the loading history. An advanced high-strength steel (AHSS) is used as a model material to demonstrate the capabilities of this new experimental method.

36 MATERIALS SCIENCE↗

LabVIEW Interface for PCI-SpaceWire Interface Card

This software provides a LabView interface to the NT drivers for the PCISpaceWire card, which is a peripheral component interface (PCI) bus interface that conforms to the IEEE-1355/ SpaceWire standard. As SpaceWire grows in popularity, the ability to use SpaceWire links within LabVIEW will be important to electronic ground support equipment vendors. In addition, there is a need for a high-level LabVIEW interface to the low-level device- driver software supplied with the card. The LabVIEW virtual instrument (VI) provides graphical interfaces to support all (1) SpaceWire link functions, including message handling and routing; (2) monitoring as a passive tap using specialized hardware; and (3) low-level access to satellite mission-control subsystem functions. The software is supplied in a zip file that contains LabVIEW VI files, which provide various functions of the PCI-SpaceWire card, as well as higher-link-level functions. The VIs are suitably named according to the matching function names in the driver manual. A number of test programs also are provided to exercise various functions.

Lux, James↗

An Integrated High Pressure SOFC and Premixed Compression Ignition (PCI) Engine System

Components for a transformative, high pressure, intermediate temperature solid oxide fuel cell (SOFC) and premixed compression ignition (PCI) engine system were developed. The resulting system is a 1 MWe natural gas fueled hybrid SOFC and reciprocating internal combustion engine system capable of achieving over 70% electrical efficiency at a cost of $0.87/W. To achieve 70% electric efficiency, the SOFC system operates at 80% fuel utilization; however, when operating at this high level of fuel utilization, fuel to the engine (anode tailgas) is extremely dilute. Accordingly, a substantial portion of the effort focused on development and assessment of the combustion strategy capable of consuming this dilute fuel mixture. The engine testing effort showed that pre-chamber assisted compression ignition provides the best combination of controllability, efficiency and emissions. The engine experiments showed that high efficiency combustion can be achieved with near zero criteria pollutants. It is likely that the engine system could operate with minimal aftertreatment requirements, reducing complexity, cost, and precious metal usage. System level modeling was used to assess the overall efficiency, determine cost and efficiency tradeoffs, and demonstrate the potential to perform load following with the hybrid system. Finally, advanced manufacturing was used to demonstrate the potential to fabricate heat exchangers needed for the hybrid system from low chromium materials, which addresses the issue of chromium poisoning of the SOFC stack material.

03 NATURAL GAS↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Post-Closure Inspection (PCI) Letter Report for Closed Non-Resource Conservation and Recovery Act (RCRA) Corrective Action Units (CAUs) on the Nevada National Security Site (NNSS), for Calendar Year (CY) 2020

This letter report is for the following CAUs for CY 2020, including CAUs located on the Nevada Test and Training Range (NTTR) that are accessed through the NNSS Main Gate. Use restriction (UR) issues that were identified in the 2019 inspections were addressed in 2020.

54 ENVIRONMENTAL SCIENCES↗

PCI: A PATRAN-NASTRAN model translator

The amount of programming required to develop a PATRAN-NASTRAN translator was surprisingly small. The approach taken produced a highly flexible translator comparable with the PATNAS translator and superior to the PATCOS translator. The coding required varied from around ten lines for a shell element to around thirty for a bar element, and the time required to add a feature to the program is typically less than an hour. The use of a lookup table for element names makes the translator also applicable to other versions of NASTRAN. The saving in time as a result of using PDA's Gateway utilities was considerable. During the writing of the program it became apparent that, with a somewhat more complex structure, it would be possible to extend the element data file to contain all data required to define the translation from PATRAN to NASTRAN by mapping of data between formats. Similar data files on property, material and grid formats would produce a completely universal translator from PATRAN to any FEA program, or indeed any CAE system.

Sheerer, T. J.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a synthetic phase contrast imaging diagnostic for turbulence studies at Wendelstein 7-X

Abstract We present a synthetic phase contrast imaging (PCI) diagnostic for studying turbulence at the Wendelstein 7-X (W7-X) stellarator. We first describe the implemented instrument response model, which captures diffraction effects, detector noise, and the long-wavelength cutoff due to the phase plate of the PCI system. To verify the instrument response model, we show that it is capable of reproducing the PCI signal generated by the sound wave speaker used for calibration at W7-X. Next, we discuss the calculation of synthetic PCI signals based on the global, nonlinear gyrokinetic codes GENE-3D and EUTERPE, including results from some of the first stellarator simulations of this type with kinetic electrons (KEs) in GENE-3D. While the simulations used in this work lack a neoclassical radial electric field, which is crucial for reproducing experimental PCI signals, they do indicate that the dominant rotation direction and velocities of the turbulent fluctuations can be inferred from the wave number-frequency spectra of the PCI signals, as expected. The synthetic PCI wave number spectra are further shown to be similar to those of the line-integrated fluctuating electron density, with distinct differences between adiabatic and KE simulations, explainable by previously published turbulence models. For example, the wave number spectra of all adiabatic electron simulations analyzed here follow a power law with an exponent close to −5 for sufficiently large wave numbers. This indicates that universal features of electron density turbulence at W7-X may be studied using the PCI system.

EUTERPE↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Localized phase contrast imaging at the Wendelstein 7-X stellarator

In its basic form, phase contrast imaging (PCI) provides line-integrated measurements of electron density fluctuations in plasmas. As turbulent fluctuations in magnetically confined plasmas have wave vectors almost perpendicular to the background magnetic field, the signals scattered by fluctuations from different parts of the PCI line-of-sight (LoS) are spatially separated in focal planes of the plasma. This allows localized PCI measurements by placing a mask in such a plane, to only permit signals from specific parts of the LoS to reach the PCI detectors. The present paper describes modeling and design of localization masks for the PCI system at the Wendelstein 7-X (W7-X) stellarator as well as the first results obtained using the masks in the recent long-pulse W7-X experimental campaign. During this project, we have extended the theory describing the mask response within the Fraunhofer diffraction model. As a novel development, we show from first principles that the mask response is determined by the fraction of power of the scattered beam spots that passes the mask. These insights have been used to select the W7-X mask design, consisting of a circular cutout, allowing the unscattered beam spot to pass the mask, with wedges covering a fixed angular range outside the central cutout. In the recent W7-X experimental campaign, the masks have verified the location of the main turbulence features observed by the PCI system and provided new information about the location of short-wavelength magnetohydrodynamic modes.

Physics↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Pellet Cladding Interaction In-Reactor Ramp Testing in a World without the Halden Boiling Water Reactor

One of the most crucial performance areas for fuel rods in water cooled nuclear power plants is interaction between cladding tubes and fuel pellets. Experimental programs in test reactors have provided key data to help fuel developers and plant operators understand Pellet Cladding Interaction (PCI) phenomena and optimize their strategies for reliable fuel performance. Approximately 50 years of “ramp” testing programs, where the fission heating rate is deliberately manipulated in test rods, have been performed in a handful of test reactors to reveal and understand PCI behaviors such as iodine-assisted stress corrosion cracking. Unfortunately, the test reactors most engaged in this type of work have all been retired over the years up to the recent and unexpected closure of the Halden Boiling Water Reactor which effectively caused a hiatus in PCI ramp testing programs. The need for ramp testing is crucial at this time to enable refined PCI understanding as more plants consider implementing flexible operations, increased fuel rod burnup limits, and new fuel technologies with enhanced accident tolerance. This paper reviews some of the key PCI phenomena that must be addressed with in-pile testing and surveys past test reactor’s methods for achieving the needed conditions. A strategic approach is then presented using test reactors and complimentary facilities which are still available today. Near term data opportunities are put forth along with capability development strategies that will ensure future longevity in this field of research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Supported Electrophilic Organoruthenium Catalyst for the Hydrosilylation of Olefins

A series of supported electrophilic organoruthenium complexes has been synthesized via surface organometallic chemistry (SOMC) techniques and applied to the selective hydrosilylation of olefins. The air-sensitive 16e - complex Cp*RuMes(PCy 3 ) (1) (Cp* = pentamethylcyclopentadienyl, Mes = mesityl) was synthesized by the treatment of Cp*RuCl(PCy 3 ) with mesityl Grignard MesMgBr. This species was chemisorbed onto sulfated zirconia SO 4 /ZrO 2 , but the resulting material was inactive toward cyclohexene hydrosilylation with phenylsilane. Instead, Cp*RuMes(PCy 3 ) was treated with phenylsilane (PhSiH 3 ) to provide a ruthenium disilyl hydride complex Cp*RuH(SiH 2 Ph) 2 (PCy 3 ) (3), which was fully characterized by NMR spectroscopy and single-crystal X-ray diffraction. Grafting this species onto SO 4 /ZrO 2 resulted in the formation of phenylsilane along with the surface electrophilic species [Cp*RuH(R)(X-SiHPh)(PCy 3 )] (R = H, O 3 S-O or O 3 Zr-O; 4a, 4b, X = O 3 S-O, and O 3 Zr-O, respectively) as the major species. Material 4 was characterized via a combination of spectroscopic techniques including dynamic nuclear polarization (DNP)-enhanced solid-state NMR spectroscopy, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), X-ray absorption spectroscopy (XAS), and density function theory (DFT) calculations. Further, capping the remaining acid sites on 4 with Me 3 Si-SiMe 3 provides 5, which significantly reduces side reactions, such as olefin isomerization and silane redistribution. Catalyst 5 is a highly robust and selective hydrosilylation catalyst and can be recycled up to 5 times without significant diminishment of activity. Exclusive anti-Markovnikov regiochemistry, cis-addition selectivity, and the inactivity of secondary and tertiary silanes provide support for the proposed Glaser-Tilley mechanism involving cationic ruthenium silylene species analogous to homogeneous systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗