Search NASA⌕ Search

SEARCH · Search NASA

Results for “PFIB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Using Xe Plasma FIB for High-Quality TEM Sample Preparation

Here, a direct comparison between electron transparent transmission electron microscope (TEM) samples prepared with gallium (Ga) and xenon (Xe) focused ion beams (FIBs) is performed to determine if equivalent quality samples can be prepared with both ion species. We prepared samples using Ga FIB and Xe plasma focused ion beam (PFIB) while altering a variety of different deposition and milling parameters. The samples’ final thicknesses were evaluated using STEM-EELS $\textit{t/λ}$ data. Using the Ga FIB sample as a standard, we compared the Xe PFIB samples to the standard and to each other. We show that although the Xe PFIB sample preparation technique is quite different from the Ga FIB technique, it is possible to produce high-quality, large area TEM samples with Xe PFIB. We also describe best practices for a Xe PFIB TEM sample preparation workflow to enable consistent success for any thoughtful FIB operator. For Xe PFIB, we show that a decision must be made between the ultimate sample thickness and the size of the electron transparent region.

47 OTHER INSTRUMENTATION↗

Degradation Diagnostics from the Subsurface of Lithium-Ion Battery Electrodes

Despite the long-established rocking-chair theory of lithium-ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe + PFIB)-based characterization technique to probe the cross-sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in-depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Here, through the quantitative analysis of the transition-metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB-based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high-sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity-fade observed in most LIBs.

25 ENERGY STORAGE↗

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

Plasma Focused Ion Beam Milling of High-Aspect-Ratio Holes in Diamond

Plasma focused ion beam (PFIB) technology has a great potential for applications requiring rapid micro-machining of high-aspect-ratio features. Here, we use 30-keV Ar, Xe, and O 2 ion beams to study PFIB milling of high-aspect-ratio circular holes in polycrystalline diamond. Our results show that Xe and O 2 ion beams have the highest milling efficiency for low-aspect-ratio and high-aspect-ratio hole milling, respectively. Each ion beam species produces holes with its characteristic shape and wall surface morphology. In conclusion, based on these results, we demonstrate a “hybrid” hole milled in a two-step process with Xe and O 2 ion beams with the geometry and wall morphology attractive for the attachment of a fuel fill tube to the inertial confinement fusion capsule.

ICF targets↗

Capturing Carbonation: Understanding Kinetic Complexities through a New Era of Electron Microscopy

Cryogenic plasma focused ion beam (PFIB) electron microscopy analysis is applied to visualizing ex situ (surface industrial) and in situ (subsurface geologic) carbonation products, to advance understanding of carbonation kinetics. Ex situ carbonation is investigated using NIST fly ash standard #2689 exposed to aqueous sodium bicarbonate solutions for brief periods of time. In situ carbonation pathways are investigated using volcanic flood basalt samples from Schaef et al. (2010) exposed to aqueous CO 2 solutions by them. The fly ash reaction products at room temperature show small amounts of incipient carbonation, with calcite apparently forming via surface nucleation. Reaction products at 75° C show beginning stages of an iron carbonate phase, e.g., siderite or ankerite, common phases in subsurface carbon sequestration environments. This may suggest an alternative to calcite in carbonation low calcium-bearing fly ashes. Flood basalt carbonation reactions show distinct zonation with high calcium and calcium-magnesium bearing zones alternating with high iron-bearing zones. The calcium-magnesium zones are notable with occurrence of localized pore space. Oscillatory zoning in carbonate minerals is distinctly associated with far-from-equilibrium conditions where local chemical environments fluctuate via a coupling of reaction with transport. The high porosity zones may reflect a precursor phase (e.g., aragonite) with higher molar volume that then “ripens” to the high-Mg calcite phase-plus-porosity. These observations reveal that carbonation can proceed with evolving local chemical environments, formation and disappearance of metastable phases, and evolving reactive surface areas. Together this work shows that future application of cryo-PFIB in carbonation studies would provide advanced understanding of kinetic mechanisms for optimizing industrial-scale and commercial-scale applications.

36 MATERIALS SCIENCE↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗

Recent Developments in Femtosecond Laser-Enabled TriBeam Systems

Streams of multimodal three-dimensional (3D) and four-dimensional (4D) data are revolutionizing our ability to design and predict the behavior of a broad array of advanced materials systems. Over the last 10 years, a new 3D imaging platform consisting of a femtosecond (fs) pulsed laser coupled with a focused ion beam scanning electron microscope (FIB SEM) has been developed by UC Santa Barbara in collaboration with Thermo Fisher Scientific (formerly FEI). The femtosecond-laser-enabled FIB SEM, called the TriBeam, has become one of the only 3D serial sectioning methods available that can gather millimeter-scaled multimodal datasets at sub-μm voxel resolutions; these length scales are critical for many materials problems. Multimodal chemical, crystallographic, and morphological information can be gathered rapidly on a layer-by-layer basis and reconstructed in 3D. Large (gigabyte to terabyte scale) 3D datasets have been generated for a broad array of materials systems, including metallic alloys, ceramics, biomaterials, polymer- and ceramic-matrix composites, and semiconductors. The research tasks conducted have resulted in a completely new design, operating with a dual-wavelength femtosecond-pulsed laser on a plasma focused ion beam (PFIB) platform.

36 MATERIALS SCIENCE↗

Evaluating the bond strength and fracture mechanisms of cold-sprayed zinc coating on AZ91 magnesium substrate via a combined experimental and computational approach

Magnesium (Mg) alloys are ideal candidates for automotive applications due to their high strength to weight ratio, castability, recyclability etc., however, they lack corrosion and oxidation resistance. Solid-state deposition techniques, such as cold spray, have been demonstrated to enhance their corrosion resistance as it relies on the severe plastic deformation of powder particles upon impact with the substrate to form a metallurgical bond with the substrate and within the coating. At cold sprayed interfaces, a heterogeneous microstructure is formed that includes some porosity, oxides and intermetallics which can significantly affect coating performance. Thus, establishing a direct correlation between the interface microstructure and its properties can aid in designing optimal cold spray parameters. In this study, we investigated the microstructure and mechanical properties of a zinc (Zn) coating deposited on a high pressure die cast (HPDC) AZ91 Mg substrate via high resolution scanning transmission electron microscopy, in situ micro-tensile testing, and finite element method (FEM) modeling. Micro-tensile pillars fabricated using the plasma focused ion beam (PFIB) successfully isolates the coating-substrate interface within the gauge length. The average bond strength of Zn-Mg interface was determined to be ∼140 MPa with failure occurring partially at the interface and mostly into the coatings. A detailed microstructural characterization revealed evidence of a strong metallurgical bonding at the Zn-Mg interface and formation of the C14 MgZn 2 laves phase interlayer resulting in a mixed mode of fracture during the micro-tensile experiments. FEM modeling reveals the stress distribution along the interfaces and suggests that a MgZn 2 layer thickness between 200–400 nm is optimum to increase the bond strength and minimize the triaxiality. Such a site-specific interfacial analysis with correlative computational modeling provides crucial insight into the overall performance of cold spray interfaces.

Bond strength↗

Prelithiated SiO x /Graphite-NMC811 Cells: Capacity Loss, Impedance Rise and Hidden Degradation Pathways Revealed Using Three-Electrode Diagnostics

Electrodes containing SiO x /graphite (Gr) materials are attractive as anodes for high-energy lithium-ion batteries. However, their mechanical deformation, electrochemical response, and impedance evolution during long-term cycling are strongly coupled, complicating accurate diagnosis of performance fade mechanisms. In this work, the behavior of electrochemically prelithiated SiO x /Gr anodes paired with NMC811 cathodes is systematically investigated using techniques that include in-situ dilatometry, three-electrode electrochemistry, and multiscale post-cycling microscopy. The SiO x /Gr electrode exhibits a maximum expansion of 49% upon lithiation to 10 mV vs Li + /Li, with 84% of the expansion and 91% of the capacity being reversible. In full cells, relatively stable cycling with only 12% capacity fade over 500 cycles is observed. Three-electrode experiments reveal cell-level impedance growth, which is dominated by the NMC811 cathode: the SiO x /Gr anode exhibits minimal net impedance rise and an initial impedance decrease at low potentials. Despite this apparent electrochemical stability, cross-sectional SEM, PFIB tomography, and cryo-STEM reveal irreversible anode thickening caused by the accumulation of an inorganic-rich solid electrolyte interphase (SEI) permeating the anode bulk. Electrode potential-shift analysis further demonstrates that Li + ions released from lithium reservoirs in the prelithiated anode mask true lithium inventory loss during aging. These results demonstrate that low-expansion SiO x /Gr anodes can simultaneously exhibit favorable cycling and impedance metrics while undergoing substantial, hidden degradation, underscoring the importance of electrode-resolved diagnostics for evaluating prelithiated silicon-based anodes.

25 ENERGY STORAGE↗

Chemical Vapor Deposition-Grown Hexagonal Boron Nitride and Graphene for Tandem Dielectric Capacitive Polymer Devices

To address the low energy density of polymeric capacitors, this work explores how tandem combinations of antagonistic properties can enhance energy storage. We introduce multilayer architecture integrating chemical vapor deposition (CVD)-grown ≈2 nm hexagonal boron nitride (hBN) and graphene with ferroelectric polyvinylidene fluoride (PVDF) and linear polyetherimide (PEI) layers to suppress leakage paths, reduce loss, and promote Maxwell–Wagner–Sillars polarization. Raman spectroscopy, X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), and plasma focused ion beam (PFIB) analyses confirm robust material integration. In conclusion, for the tandem device, E BD ≈600 V/μm, while individual layers show lower values (PVDF|Graphene (Gr)|PVDF ≈ 50 V/μm and PEI|hBN|PEI ≈ 275 V/μm), yielding an overall ≈6000% enhancement and demonstrating the effectiveness of the 2D multilayer design.

Chemical vapor deposition (CVD)↗

Isolation of Single Donors in ZnO

The shallow donor in zinc oxide (ZnO) is a promising semiconductor spin qubit with optical access. Single indium donors are isolated in a commercial ZnO substrate using plasma focused ion beam (PFIB) milling. Quantum emitters are identified optically by spatial and frequency filtering. The indium donor assignment is based on the optical bound exciton transition energy and magnetic dependence. The emission stability of these single donors in terms of both intensity and frequency, alongside their transition linewidths less than twice the lifetime limit, highlight the promise of single In donors as optically accessible spin qubits. Here, the optical stability of single donors after FIB fabrication is promising for optical device integration required for scalable quantum technologies based on single donors in direct band gap semiconductors.

42 ENGINEERING↗

Multiscale Cryo Electron Microscopy Reveals Interfacial Degradation and Stabilization in Battery Electrodes

Electrochemical interfaces are dynamic systems, evolving based on their local environment and reactant surface structures. The electrode-electrolyte interface in Li-ion batteries can be protective, limiting parasitic reactions with the electrolyte to passivate the surface [1]. Additionally, this interphase has an impact on the Li-ion transport through that layer based on its composition, bonding environment, and thickness. These parameters are challenging to collect and may vary depending on the electrode surface site investigated relative to its spatial position in a coin cell. This study will detail a multiscale cryogenic electron microscopy approach where millimeter-scale cross-sections through the coin cell batteries were made using a cryogenic stage within a fs-laser plasma focused ion beam (laser PFIB) with complementary energy dispersive X-ray spectroscopy able to detect variations in the composition at electrode interfaces [2]. Microscale cross-sectioning and lamella sample preparation of battery electrodes was conducted at the Center for Integrated Nanotechnologies using a Ga-ion focused ion beam (FIB) with air-free and cryo-transfer [3], followed by nanoscale mapping of composition and bonding within the CEI through cryo-scanning transmission electron microscopy (cryo-STEM) electron energy loss spectroscopy [4]. This multiscale approach enabled identification of millimeter-scale features of a battery stack with visualization of degradation in electrodes such as cracks in cathode particles, gas evolution, and SEI evolution; microscale interfacial characteristics, such as heterogeneity in the SEI or barrier layer and identification of electrolyte networks to the electrode surfaces; and nanoscale measurement of the CEI thickness, mapping of transition metal bonding within the cathode particles to identify loss of active materials, and identification of beneficial electrolyte additives incorporated into the CEI structure. This multiscale approach allows for a statistical understanding of the primary mechanisms and parasitic degradation pathways that impact performance by limiting the ion transport pathways within Li+ batteries.

36 MATERIALS SCIENCE↗

High-Throughput Ion Irradiation and Microstructural Characterization of Multi-Principal-Element Alloys

Multi-principal-element alloys (MPEAs) have garnered interest in the nuclear community for their apparent resistance to microstructural damage under irradiation. While both experimentation and simulation have demonstrated reduced hardening and void swelling in MPEAs, the relationship between composition and irradiation response is still poorly understood since a rich experimental database for MPEAs does not yet exist. In this work, to accelerate the generation of experimental irradiation-response data for MPEAs, high-throughput synthesis, irradiation, and characterization techniques have been employed. Specifically, additive manufacturing has been used to produce arrays of various MPEAs (1-cm2 coupons), which have been subsequently irradiated using 4-MeV Ni2+ ions to a peak damage of 200 dpa at 500 °C. Hardening and void swelling have been assessed using nanoindentation and trenching via plasma focused ion beam (PFIB), respectively. Trends in the experimental data relating hardening and void swelling behavior to composition have been analyzed using different machine learning approaches.

36 MATERIALS SCIENCE↗

Focused Ion Beam Preparation of Low Melting Point Metals: Lessons Learned From Indium

Indium (In) and other low melting point metals are used as interconnects in a variety of hybridized circuits and a full understanding of the metallurgy of these interconnects is important to the reliability and performance of the devices. Here, this paper shows that room temperature focused ion beam (FIB) preparation of cross-sections, using Ga + or Xe + can result in artifacts that obscure the true In microbump structure. The use of modified milling strategies to minimize the increased local sample temperature are shown to produce cross-sections that are representative of the In bump microstructure in some sample configurations. Furthermore, cooling of the sample to cryogenic temperatures is shown to reliably eliminate artifacts in FIB prepared cross-sections of In bumps allowing the true bump microstructure to be observed.

36 MATERIALS SCIENCE↗

Cryogenic EM Across Length Scales for Li Metal Anode Batteries

An interfacial understanding is necessary for developing strategies to commercialize high-energy density rechargeable lithium metal anode batteries, as currently, the lithium anode/electrolyte interface is unstable with prolonged cycling. We have used several strategies to improve the cycling performance of lithium metal anodes, including reducing the parasitic reactions between lithium metal and the electrolyte, and improving the electrodeposited lithium metal morphology. These strategies have generated unconclusive electrochemical data, that has required the need for nanoscale interfacial characterization of these solid-liquid interfaces. Our team has used the cryogenic transfer workflow developed by Leica in collaboration with cryo-SEM/FIB tools by Thermo Fisher Scientific to cross-section lithium metal anodes and intact coin cell batteries to observe the interfacial structures, lithium morphology, and failure mechanisms relative to changes in electrode contract pressure and electrolyte chemistry. Cross-sectional SEM images and EDS maps of the lithium metal anodes have provided a better understanding of the electrodeposited lithium morphology, quantity of 'dead' lithium metal, and quantity of solid electrolyte interphase material that has formed alongside the lithium metal. In understanding lithium metal battery failure at the system level, we used a cryogenic stage in a laser plasma FIB to cross-section through the coin cell's cap for imaging/mapping the entire battery stack under cryogenic conditions. The tools, methods, and results of these studies will be detailed in this presentation.

characterization↗