Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIXIE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron activation analysis using gamma-gamma coincidence to eliminate spectral interferences

The use of neutron activation analysis (NAA) sometimes has limitations with the identification of specific gamma ray peaks due to spectral interferences. The implementation of gamma-gamma coincidence techniques using the XIA Pixie-16 system has demonstrated the ability reduce many of these challenges. In this work, experiments were performed on two different NIST reference materials using gamma-gamma coincidence techniques to identify long-lived radionuclides that are often difficult to evaluate due to various spectral interferences. The experiments have shown that utilizing gamma-gamma coincidence with the XIA Pixie-16 system for 177m Lu, 124 Sb, 160 Tb, 175 Yb, and 153 Sm can eliminate spectral interferences and high backgrounds due to Compton scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Constraining low redshift [C II ] emission by cross-correlating FIRAS and BOSS data

ABSTRACT We perform a tomographic cross-correlation analysis of archival FIRAS data and the BOSS galaxy redshift survey to constrain the amplitude of [C II] 2P3/2 → 2P1/2 fine structure emission. Our analysis employs spherical harmonic tomography (SHT), which is based on the angular cross-power spectrum between FIRAS maps and BOSS galaxy over-densities at each pair of redshift bins, over a redshift range of 0.24 < z < 0.69. We develop the SHT approach for intensity mapping, where it has several advantages over existing power spectral estimators. Our analysis constrains the product of the [C II] bias and [C II] specific intensity, $b_{\rm [C \small{\rm II}]}I_{\rm [C \small{\rm II}]}$, to be <0.31 MJy/sr at z ≈ 0.35 and <0.28 MJy/sr at z ≈ 0.57 at $95{{\ \rm per\ cent}}$ confidence. These limits are consistent with most current models of the [C II] signal, as well as with higher-redshift [C II] cross-power spectrum measurements from the Planck satellite and BOSS quasars. We also show that our analysis, if applied to data from a more sensitive instrument such as the proposed PIXIE satellite, can detect pessimistic [C II] models at high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral distortion anisotropy from inflation for primordial black holes

Single-field inflationary models that seek to greatly enhance small-scale power in order to form primordial black holes predict both a squeezed bispectrum that is enhanced by this small-scale power and a potentially detectable enhancement of cosmic microwave background (CMB) spectral distortions. Despite this combination, spectral distortion anisotropy on CMB scales remains small since the squeezed bispectrum represents an unobservable modulation of the scale rather than local amplitude for the short-wavelength acoustic power that dissipates and forms the μ spectral distortion. Furthermore, the leading-order amplitude effect comes from the local modulation of acoustic dissipation at the beginning of the μ epoch at the end of thermalization by a long-wavelength mode that is correlated with CMB anisotropy itself. Compensating factors from the suppression by the square of the ratio the comoving horizon at thermalization to the smallest detectable primary CMB scales (~0.0005) and maximal allowed enhancement of μ (~5000) leaves a signal in the μT cross spectrum that is still well beyond the capabilities of PIXIE or LiteBIRD space missions due to sensitivity and resolution while remaining much larger than in single-field slow-roll inflation and potentially observable.

79 ASTRONOMY AND ASTROPHYSICS↗

Exotic energy injection in the early Universe. II. CMB spectral distortions and constraints on light dark matter

Here, we calculate the post-recombination contribution to the cosmic microwave background (CMB) spectral distortion due to general exotic energy injections, including dark matter (DM) decaying or annihilating to Standard Model particles. Upon subtracting the background distortion that would be present even without such energy injections, we find residual distortions that are still potentially large enough to be detectable by future experiments such as PIXIE. The distortions also have a high-energy spectral feature that is a unique signature of the injection of high-energy particles. We present a calculation of the global ionization history in the presence of decaying dark matter with sub-keV masses, and also show that previous calculations of the global ionization history in the presence of energy injection are not significantly modified by these additional spectral distortions. Our improved treatment of low-energy electrons allows us to extend calculations of the CMB anisotropy constraints for decaying DM down to arbitrarily low masses. We also recast these bounds as constraints on the coupling of axionlike particles to photons.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB spectral distortions from cooling macroscopic dark matter

We propose a new mechanism by which dark matter (DM) can affect the early and late Universe. The hot interior of a macroscopic DM, or macro, can behave as a heat reservoir so that energetic photons and neutrinos are emitted from its surface and interior, respectively. In this paper, we focus on the spectral distortions (SDs) of the cosmic microwave background before recombination. Here, the SDs depend on the density and the cooling processes of the interior and the surface composition of the macros. We use neutron stars as a model for nuclear-density macros and find that the spectral distortions are mass independent for a fixed density. In our work, we find that, for macros of this type that constitute 100% of the dark matter, the μ and y distortions can be near or above the detection threshold for typical proposed next-generation experiments such as PIXIE.

79 ASTRONOMY AND ASTROPHYSICS↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integration of SARS-CoV-2 testing and genomic sequencing into influenza sentinel surveillance in Uganda, January to December 2022

The Uganda Virus Research Institute, National Influenza Center laboratory integrated SARS-CoV-2 polymerase chain reaction testing and genomic sequencing into the influenza surveillance program that was established in 2007. A total of 7,698 nasopharyngeal/oropharyngeal (NP/OP) swab samples were collected and analyzed from ILI/SARI sentinel sites across the country from January to December 2022. All samples were tested for influenza and SARS-CoV-2. Of these, 252 (3.3%), 162 (2.1%), and 589 (7.7%) were positive for influenza A, influenza B, and SARS-CoV-2, respectively. Out of 414 influenza-positive samples, 122 (29.5%) were AH1pdm09, 130 (31.4%) were AH3, and 162 (39.1%) were B-Victoria. All SARS-CoV-2 sequenced samples were of the Omicron variant, with subvariants of concern known to evade the immune system being detected, such as BQ.1 and XBB.2. Other SARS-CoV-2 positive samples collected from other health centers in the community outside the surveillance sites were included into SARS-CoV-2 genomic sequencing with similar patterns with respect to variants. In all, the ILI/SARI surveillance system has shown to be an efficient, cost-effective, and sustainable program, providing a ready platform to monitor the circulation of SARS-CoV-2 in communities at the national level while remaining vigilant for the persistent threat of influenza. The integration of SARS-CoV-2 detection and genomic surveillance into the influenza surveillance program will strengthen the laboratory response capacity, as well as facilitate the timely release of SARS-CoV-2 genomic information to be used to complement the multiple response strategies for COVID-19 pandemic mitigation.

59 BASIC BIOLOGICAL SCIENCES↗