Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV emulator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning for photovoltaic single axis tracker fault detection and classification

More than 81% of the annual capacity of utility-scale photovoltaic (PV) power plants in the U.S. use single-axis trackers (SATs) due to SATs delivering 4% in capacity factor on average over fixed-array systems. However, SATs are subject to faults, such as software misconfigurations and mechanical failures, resulting in suboptimal tracking. If left undetected, the overall power yield of the PV power plant is reduced significantly. Minimizing downtime and ensuring efficient operation of SATs requires robust detection and diagnosis mechanisms for SAT faults. We present a machine learning framework for implementing real-time SAT fault detection and classification. Our implementation of the proposed framework reliably identifies measurements taken from a test PV system undergoing emulated SAT faults relative to state-of-the-art algorithms and produces nearly zero false positives on our testing days. Code and data are available at https://pvpmc.sandia.gov/tools.

Fault classification↗

Impact of duration and missing data on the long-term photovoltaic degradation rate estimation

Accurate quantification of photovoltaic (PV) system degradation rate (R D ) is essential for lifetime yield predictions. Although R D is a critical parameter, its estimation lacks a standardized methodology that can be applied on outdoor field data. The purpose of this paper is to investigate the impact of time period duration and missing data on R D by analyzing the performance of different techniques applied to synthetic PV system data at different linear R D patterns and known noise conditions. The analysis includes the application of different techniques to a 10-year synthetic dataset of a crystalline Silicon PV system, with emulated degradation levels and imputed missing data. Here, the analysis demonstrated that the accuracy of ordinary least squares (OLS), year-on-year (YOY), autoregressive integrated moving average (ARIMA) and robust principal component analysis (RPCA) techniques is affected by the evaluation duration with all techniques converging to lower R D deviations over the 10-year evaluation, apart from RPCA at high degradation levels. Moreover, the estimated R D is strongly affected by the amount of missing data. Filtering out the corrupted data yielded more accurate R D results for all techniques. It is proven that the application of a change-point detection stage is necessary and guidelines for accurate R D estimation are provided.

14 SOLAR ENERGY↗

Operation and Control of a PV Converter with Enhanced Stability Based on Virtual Impedance Emulation in a Pseudo Resistive Grid

A three-phase grid-connected photo-voltaic converter is investigated to enhance its operational capabilities and stability margins. These converters are generally connected to the grid with an inductive impedance. In this paper the possibility of using a resistive impedance to enhance the stability of the overall system has been investigated. To reduce the losses in the system, rather than using a real resistance, a virtual resistance is emulated inside the control architecture to ensure resistive power transfer between two sources. The stability results with inductive and resistive grids are presented based on the previously reported frequency response. The overall system is modeled via MATLAB/Simulink and several important case study results are presented in this paper to verify the efficacy of the proposed architecture.

grid-forming controls↗

SoDa: An Irradiance-Based Synthetic Solar Data Generation Tool (SoDa) v0.1

SoDa is an irradiance-based synthetic Solar Data generation tool to generate realistic sub-minute solar photovoltaic (PV) power time series, that emulate the weather pattern for a certain geographical location. Our tool relies on the National Solar Radiation Database (NSRDB) to obtain irradiance and weather data patterns for the site. Irradiance is mapped onto a PV model estimate of a solar plant's 30-min power output, based on the configuration of the panel. We use a stochastic model with a switching behavior due to different weather regimes as provided by the cloud type label in the NSRDB, with parameters for the cloudy states trained on the high-resolution solar power measurements from a Phasor Measurement Unit (PMU).

Carreno, IgnacioLosada↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Photovoltaic System Health-State Architecture for Data-Driven Failure Detection

The timely detection of photovoltaic (PV) system failures is important for maintaining optimal performance and lifetime reliability. A main challenge remains the lack of a unified health-state architecture for the uninterrupted monitoring and predictive performance of PV systems. To this end, existing failure detection models are strongly dependent on the availability and quality of site-specific historic data. The scope of this work is to address these fundamental challenges by presenting a health-state architecture for advanced PV system monitoring. The proposed architecture comprises of a machine learning model for PV performance modeling and accurate failure diagnosis. The predictive model is optimally trained on low amounts of on-site data using minimal features and coupled to functional routines for data quality verification, whereas the classifier is trained under an enhanced supervised learning regime. The results demonstrated high accuracies for the implemented predictive model, exhibiting normalized root mean square errors lower than 3.40% even when trained with low data shares. The classification results provided evidence that fault conditions can be detected with a sensitivity of 83.91% for synthetic power-loss events (power reduction of 5%) and of 97.99% for field-emulated failures in the test-bench PV system. Finally, this work provides insights on how to construct an accurate PV system with predictive and classification models for the timely detection of faults and uninterrupted monitoring of PV systems, regardless of historic data availability and quality. Such guidelines and insights on the development of accurate health-state architectures for PV plants can have positive implications in operation and maintenance and monitoring strategies, thus improving the system’s performance.

photovoltaics↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

NDNSEG (Named Data Network Scalable Environment Generator) [SWR-21-91]

NDNSEG (Named Data Network Scalable Environment Generator) automates the deployment of NDN environments in NREL's Cyber-Energy Emulation Platform (CEEP). Specifying the number of clients, servers, gateways, and pv_inverters and running NDNSEG will automate the generation of required files to deploy the number of specified virtual machines, the underlying networking infrastructure, and configuration for GitLab CI/CD.

Peterson, Jordan↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating System to Edge-of-Network Architecture and Management for SHINES (SEAMS) Technologies of High Penetration Grids

Consistent with the U.S. DOE’s EERE SHINES FOA objectives, the goal of this project was to enable integration from EMS to variable DER in a way that delivered visibility and opportunities for managing and controlling distributed resources using SEAMS technologies. This project implemented several SHINES technologies, which included: (1) three Stem battery systems; (2) six ConnectDER PV collars; (3) two E-Gear PV/Battery storage interfaces; and (4) eight Kitu smart inverter emulators. A Siemens Energy IP DEMS was deployed in a development environment and integrated with the SHINES technologies via OpenADR and IEEE 2030.5 protocols with documented architecture. In the case of IEEE 2030.5, a suite of technologies including a gateway, an API, software and a server from Kitu Systems (the Citadel, Convoy, Kitu Crosslink API, and Kitu Spark) were used to demonstrate that the utility could achieve visibility of distributed energy resources (DER) and control of single and multiple DER systems with a single command. The project also included a LCOE analysis of SHINES technologies compared to traditional system and circuit mitigation measures.

14 SOLAR ENERGY↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Events Emulation Based Transmission and Distribution Co-Simulation for Situation Awareness and Grid Anomaly (SAGA) Detection: Preprint

Energy management of transmission and distribution networks is becoming more challenged with the accelerated increasing of distributed energy resources (DERs) such as distributed photovoltaic (PV) generation and distributed energy storage. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive transmission and distribution co-simulation platform should be developed. Furthermore, with DERs more actively participated in system operation such as providing real time grid services, their cyber vulnerability should be better understood to maintain system reliability. This paper discussed a cyber-physical events emulation based transmission & distribution co-simulation platform to perform different cyber events emulation and analyze the impacts of cyber physical events happened in distribution system on the T&D system operation. The case studies with both a transmission network and a synthetic distribution network data validate that the proposed T&D co-simulation platform can perform comprehensive cyber physical events emulation. Therefore, with extensive simulation using the proposed model, the system operator can accumulate adequate training data for the system situation awareness and grid anomaly detection purpose.

31 CESER - Office of Cybersecurity, Energy Securit↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Interoperable, Inverter-Based Distributed Energy Resources (DERs) Enable 100% Renewable and Resilient Utility Microgrids

Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.

battery energy storage systems↗