Search NASA⌕ Search

SEARCH · Search NASA

Results for “PVT scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nature of Moisture-Induced fogging defects in scintillator plastic

Polyvinyl toluene (PVT) scintillator plastic may degrade in the field due to inward water diffusion at elevated temperatures, which exceeds the saturation limit at lower temperatures, and after long periods of time (e.g., many years), leads to the formation of disk-like defects that attenuate scintillation light, leading to detector degradation. In this work, using fractography and high-magnification optical and electron microscopy to characterize the water-induced defects, a model of the fogging process is hypothesized as follows: excess water present at low temperatures diffuses to spheroids to minimize contact with the hydrophobic polymer. Through the hydrophobic effect, the entropy of water increases by forming nanoclusters which minimizes the contact between the water and the PVT. As the water nanoclusters grow, they break and fold the polymer into densely-packed crystalline regions creating more space for water within the spheroids. The polymer outside the spheroid resists the shrinkage which builds up tension within the spheroid. Once the tensile stress exceeds the yield strength of the plastic, the spheroid is torn in half resulting in a defect. Excess water then drains into the cavities along the disk thereby further increasing its entropy. Slower cooling (over 1 day) leads to larger spheroids and hence, larger “permanent” defects. Freezing causes some defects to further grow due to the expansion of water to ice. These findings imply that the remaining lifetime of scintillator plastic in the field could be predicted using temperature and humidity data thereby mitigating security risks of degraded radiation portal monitors.

36 MATERIALS SCIENCE↗

Ba(1-x)SrxMg3SiN4:Eu narrowband red phosphor

We evaluated polyvinyl toluene (PVT) scintillators fabricated with different emitting dopants and scintillator optical configurations for fast neutron imaging. A neutron imaging apparatus was constructed to study scintillators under MeV neutron exposure. PVT with 2% Xylyl Flrpic emitter was identified as the brightest. The addition of a black backing to the scintillator, compared with a specular reflector film backing, improved the resolution of the neutron image obtained with the PVT scintillator by about 2 9. It is concluded that a PVT imaging screen with 2% Xylyl Flrpic, configured with a black backing, provides the best quality fast neutron image of the scintillators tested.

Osborne, R. A.↗

Evaluation of polyvinyl toluene scintillators for fast neutron imaging

We evaluated here polyvinyl toluene (PVT) scintillators fabricated with different emitting dopants and scintillator optical configurations for fast neutron imaging. A neutron imaging apparatus was constructed to study scintillators under MeV neutron exposure. PVT with 2% Xylyl Flrpic emitter was identified as the brightest. The addition of a black backing to the scintillator, compared with a specular reflector film backing, improved the resolution of the neutron image obtained with the PVT scintillator by about 2 ×. It is concluded that a PVT imaging screen with 2% Xylyl Flrpic, configured with a black backing, provides the best quality fast neutron image of the scintillators tested.

36 MATERIALS SCIENCE↗

Comparison of Supervised and Un-Supervised Machine Learning Algorithms for Threat Detection and Scintillator Performance for Radiation Portal Monitoring

Following the events of September 11, 2001, international border crossing have been equipped with radiation portal monitors (RPMs) to identify illicit radioactive material. Polyvinyl toluene (PVT) scintillators are commonly used due to their low cost and reasonable maintainability, however they offer low spectral resolution. Despite the fact that over twenty years has transpired since this event, radioisotopes are still typically identified by hand-crafted classification algorithms, e.g., total counts or energy windowing, and exhibit relatively poor performance in detecting threats at the low false alarm rates required to support the stream of commerce. While some improvement to performance has been realized via the use of supervised machine learning, these classification algorithms typically utilize simulations in lieu of real data due to the sparsity of data for one or more classes. Accordingly, the performance of these algorithms is somewhat less than optimal when examining experiments or simulations with model mismatch. Consequently, in this work, we examine the application of a number of unsupervised machine learning, anomaly detection based algorithms, to circumvent the inverse crime when analyzing spectroscopy data for RPMs. We also compare anomaly detection results with those obtained via the use of supervised classification detection ML algorithms when model mismatch is introduced between the simulated threat items utilized for training/testing. Finally, we compared the performance of the PVT scintillators to those obtained with higher resolution detectors using both anomaly detection and supervised classification algorithms.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PVT Degradation Studies: NMR Analysis

Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. Nuclear magnetic resonance spectroscopy has been used to elucidate the state of water inside the PVT. The deuterium NMR results show that water absorbed by PVT under warm, humid conditions enters several distinct environments, and when the PVT is transferred from incubation to ambient temperature and humidity the water is lost on a time scale of a few hours from these samples. Most of the deuterium NMR peaks can be assigned to bulk liquid water, but almost 35% of the detected signal intensity is contained in a resonance that resembles spectra of water contained in nanometer-scale pores in mesoporous carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PVT Analysis With A Deconvolution Algorithm

Polyvinyl Toluene (PVT) plastic scintillator is the most common gamma ray detector material used for large systems when only gross counting is needed because of its low cost, robustness, and relative sensitivity. PVT does provide some energy information about the incident photons, as has been demonstrated through the development of Energy Windowing analysis. There is a more sophisticated energy analysis algorithm developed by Symetrica, Inc., and they have demonstrated the application of their deconvolution algorithm to PVT with very promising results. The thrust of such a deconvolution algorithm used with PVT is to allow for identification and rejection of naturally occurring radioactive material, reducing alarm rates, rather than the complete identification of all radionuclides, which is the goal of spectroscopic portal monitors. Under this condition, there could be a significant increase in sensitivity to threat materials. The advantage of this approach is an enhancement to the low cost, robust detection capability of PVT-based radiation portal monitor systems. The success of this method could provide an inexpensive upgrade path for a large number of deployed PVT-based systems to provide significantly improved capability at a much lower cost than deployment of NaI(Tl)-based systems of comparable sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PVT Degradation Studies: Acoustic Diagnostics

Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

36 MATERIALS SCIENCE↗

Impact of temperature on light yield and pulse shape discrimination of polysiloxane-based organic scintillators formulated with commercial resins

This work investigates how increased temperature affects neutron/ discrimination and light yield (LY) in several different polysiloxane-based scintillators doped with either 9,9-dimethyl-2-phenylflourene (PhF) or 2,5-diphenyloxazole (PPO) as a primary fluorophore and 9,9-dimethyl-2,7-di((E)-styryl) fluorene (SFS) as the secondary fluorophore. The polysiloxane matrices were prepared from the commercial resins Wacker Lumisil 579 or Shin-Etsu KER-6000. Control scintillators were prepared from poly(vinyltoluene) (PVT), the industry standard matrix, as a reference point for LY and pulse shape discrimination (PSD) measurements. Samples with PhF and PPO dopant concentrations of 1 wt% and 5 wt% in the polysiloxanes and 3 wt% and 5 wt% in the PVT samples were tested at 20 °C, 35 °C, and 50 °C. In the polysiloxane samples, the KER-6000 resin outperformed the Wacker 579 and PhF proved to be a better dopant than PPO in both LY and PSD capabilities. Polysiloxane scintillators showed slight decreases in LY and increases in neutron/discrimination at increased temperatures, while PVT scintillators showed a similar LY decrease with little to no improvement in neutron/discrimination at increased temperatures. Altogether, polysiloxane scintillators may not require recalibration in applications where temperatures increase up to 50 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An approach towards plastic scintillators from thermally activated delayed fluorescent dyes and cross-linkable bismuth compounds

Cross-linked polyvinyltoluene (PVT) based plastic scintillators loaded with dyes exhibiting thermally activated delayed fluorescence (TADF) and various amounts of (caproate)di-(methacrylate) bismuth (CMB) were developed. The co-polymerization of vinyl toluene monomer loaded with different weight ratios of CMB and 1 wt% of TADF dye yielded highly transparent cross-linked plastic scintillators with intense green photoluminescence. The thermal and mechanical properties of the scintillators were investigated using thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and micro indentation techniques. Here, their performance for radiation detection was assessed by performing gamma spectroscopy using a Cs-137 source and benchmarked to commercial plastic scintillators. The loading of CMB was guided by Monte Carlo N-Particle (MCNP) simulations. The results of this study show that the cross-linking approach and the use of TADF dyes yield scintillators with good mechanical properties with a uniaxial yield strength up to ~66 MPa for compositions loaded with 40 wt% of CMB and high optical quality. However, the light yield in gamma spectroscopy experiments is found to be reduced with the addition of CMB, suggesting a trade-off between mechanical yield strength and light yield in gamma spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Accelerated Aging Test for Plastic Scintillator Gamma Ray Detectors

Polyvinyl toluene (PVT) and polystyrene (PS), collectively referred to as “plastic scintillator,” are synthetic polymer materials used to detect gamma radiation, and are commonly used in instrumentation. Recent studies have revealed that plastic scintillator undergoes an environmentally related material degradation that adversely affects performance under certain conditions and histories. A significant decrease in gamma ray sensitivity has been seen in some detectors in systems as they age. The degradation of sensitivity of plastic scintillator over time is due to a variety of factors, and the term “aging” is used to encompass all factors. Some plastic scintillator samples show no aging effects (no significant change in sensitivity over more than 10 years), while others show severe aging (significant change in sensitivity in less than 5 years). Aging effects arise from weather (variations in heat and humidity), chemical exposure, mechanical stress, light exposure, and loss of volatile components. The damage produced by these various causes can be cumulative, causing observable damage to increase over time. Damage may be reversible up to some point, but becomes permanent under some conditions. It has been demonstrated that exposure of plastic scintillator in an environmental chamber to 30 days of high temperature and humidity (90% relative humidity and 55°C) followed by a single cycle to cold temperature (-30°C) will produce severe fogging in all PVT samples. This thermal cycle will be referred to as the “Accelerated Aging Test.” This document describes the procedure for performing this Accelerated Aging Test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plastic scintillators stable for operating in wide ranges of humidity and temperature variations

To provide efficient and reproducible response to nuclear radiation, scintillating plastics should be prepared as materials of high optical transparency and homogeneity that should remain intact during the lifetime of their operation. A problem with traditionally used polyvinyltoluene (PVT) or polystyrene (PS) plastic scintillators arises from their exposure to repeated large temperature swings that cause surface and volume defects, resulting in decreased sensitivity of the detection properties. We find that the problem can be avoided by composition modifications that enable preparation of plastics with properties that are resistant to the continuous variations in environmental conditions. This paper describes improvements in physical properties that can be achieved by the addition of crosslinkers (such as divinylbenzene, DVB) and oxygen-containing compounds or copolymers (e.g. polymethylamethacrylate, PMMA) to the traditional PVT or PS polymer matrices. Results of characterization show that the new materials can be prepared with the scintillation performance equal to that of commercial plastic scintillators, such as EJ-200.

36 MATERIALS SCIENCE↗

Tensile, flexural, and light output measurements of selected organic scintillators for evaluation of their potential as structural materials

In order to design structures, such as unmanned vehicle structures, out of plastic scintillator, e.g., for radionuclide searches, suitable materials must either be identified or developed. In searches utilizing unmanned vehicles, the absence of an additional detector attached to the vehicle body as a payload could enable the vehicle to travel faster, carry a longer lived battery, or carry other auxiliary equipment which may be useful for search and/or response. To this end, four mechanical characteristics of selected organic scintillators manufactured by Eljen technologies, Sandia Livermore, and Lawrence Livermore National Lab have been measured. Specifically, tensile and flexural tests have been performed to ASTM specifications on organic scintillators with polyvinyl toluene (PVT), polystyrene (PS), or crosslinked versions of these bases. In addition to these mechanical tests, light output testing was performed in order to quantify whether crosslinking or adding organometallic complexes affects light output in the particular scintillator compositions we measured. We found that the tested plastic scintillators have strengths that are comparable to common structural plastics. We also show that chemically modifying the polymer base can show improvements in the mechanical properties without being overly detrimental to the scintillator light output.

42 ENGINEERING↗