Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The 1983 tail-era data series. Volume 3: Geosynchronous particle measurements

Geosynchronous particle measurements are presented for comparison with same-scale plots of ISEE 3 plasma and field data. Shown for each day are electron and proton fluxes measured with the low-energy-range electron and the low-energy-range proton detectors of the Los Alamos Charged Particle Analyzer. This instrument has flown aboard several geosynchronous orbit satellites, including the three spacecraft from which the presented data were obtained. The presented data are 5-min averages of the integral flux in each of several energy channels.

Fairfield, D. H.↗

Enhanced Detection of Primary Biological Aerosol Particles Using Machine Learning and Single-Particle Measurement

Accurately identifying primary biological aerosol particles (PBAPs) using analytical techniques poses inherent challenges due to their resemblance to other atmospheric carbonaceous particles. Here, we present a study of an enhanced method for detecting PBAPs by combining single-particle measurement with advanced supervised machine learning (SML) techniques. We analyzed ambient particles from a variety of environments and lab-generated standards, focusing on chemical composition for traditional rule-based and clustering approaches and incorporating morphological features into the SML approaches, neural networks and XGBoost, for improved accuracy. This study demonstrates that SML methods outperform traditional methods in quantifying PBAPs, achieving significant improvements in precision, recall, F1-score, and accuracy, leading to an increased number of detected PBAPs by at least 19%. The adaptability of the proposed XGBoost-based SML model is showcased in comparison to traditional methods in categorizing PBAPs for blind data sets from different geographical locations. Two field case studies were investigated, over agricultural land and Amazonia rain forest, representing relatively low and high concentrations of PBAPs, respectively, where XGBoost consistently detected up to 3.5 times more PBAPs than traditional methods. Precise detection of PBAPs in the atmosphere could significantly improve the prediction of climatic impacts by them.

42 ENGINEERING↗

Solar coronal and photospheric abundances from solar energetic particle measurements

Solar energetic particle (SEP) elemental abundance data from the Cosmic Ray Subsystem (CRS) aboard the Voyager 1 and 2 spacecraft are used to derive unfractionated coronal and photospheric abundances for elements with 3 = or Z or = 30. The ionic charge-to-mass ratio (Q/M) is the principal organizing parameter for the fractionation of SEPs by acceleration and propagation processes and for flare-to-flare variability, making possible a single-parameter Q/M-dependent correction to the average SEP abundances to obtain unfractionated coronal abundances. A further correction based on first ionization potential allows the determination of unfractionated photospheric abundances.

Breneman, H.↗

Solar Coronal and photospheric abundances from solar energetic particle measurements

Solar energetic particle (SEP) elemental abundance data from the cosmic ray subsystem (CRS) aboard the Voyager 1 and 2 spacecraft are used to derive unfractionated coronal and photospheric abundances for elements with 3 Z or = 30. It is found that the ionic charge-to-mass ratio (Q/M) is the principal organizing parameter for the fractionation of SEPs by acceleration and propagation processes and for flare-to-flare variability, making possible a single-parameter Q/M-dependent correction to the average SEP abundances to obtain unfractionated coronal abundances. A further correction based on first ionization potential allows the determination of unfractionated photospheric abundances.

Breneman, H.↗

Solar coronal and photospheric abundances from solar energetic particle measurements

Solar energetic particle (SEP) elemental abundance data from the cosmic ray subsystem (CRS) aboard the Voyager 1 and 2 spacecraft are used to derive unfractionated coronal and photospheric abundances for elements with Z = 6-30. It is found that the ionic charge-to-mass ratio (Q/M) is the principal organizing parameter for the fractionation of SEPs by acceleration and propagation processes and for flare-to-flare variability, making possible a single-parameter Q/M-dependent correction to the average SEP abundances to obtain unfractionated coronal abundances. A further correction based on first ionization potential allows the determination of unfractionated photospheric abundances.

Breneman, H. H.↗

The problem of low energy particle measurements in the magnetosphere

The accurate measurement of low energy (less than 100 eV) particle properties in the magnetosphere has been difficult, partly because of the low density of such particles, but more particularly because of spacecraft interference effects. Some early examples of how these phenomena have affected particle measurements on an OGO spacecraft are presented. Data obtained with the UCSD particle detectors on ATS-6 are then presented showing how some of these difficulties have been partially overcome. Future measurements of low energy particles in the magnetosphere can be improved by: (1) improving the low energy resolution of detectors; (2) building electrostatically clean spacecraft; (3) controlling spacecraft potential; and (4) using auxiliary measurements, particularly wave data.

Whipple, E. C., Jr.↗

Condensation-nuclei (Aitken Particle) measurement system used in NASA global atmospheric sampling program

The condensation-nuclei (Aitken particle) measuring system used in the NASA Global Atmospheric Sampling Program is described. Included in the paper is a description of the condensation-nuclei monitor sensor, the pressurization system, and the Pollack-counter calibration system used to support the CN measurement. The monitor has a measurement range to 1000 CN/cm cubed and a noise level equivalent to 5 CN/cm cubed at flight altitudes between 6 and 13 km.

Nyland, T. W.↗

A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton–proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector

The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton–proton collisions at $\sqrt{s} = 13$ TeV collected with the ATLAS detector during Run 2 at the Large Hadron Collider. The jet calibration uncertainty for anti-$k_T$ jets with a jet radius parameter of R$_\textrm{jet} = 0.4$ and in the central jet rapidity region is about 2.5% for transverse momenta ($p_{\text {T}}$) of 20 $\text {GeV}$ , about 0.5% for $p_{\text {T}} = 300$ GeV and 0.7% for $p_{\text {T}} = 4$ TeV . Excellent agreement is found with earlier determinations obtained from -balance based in situ methods ($Z/\gamma$ +jets). The combination of these two independent methods results in the most precise jet energy measurement achieved so far with the ATLAS detector with a relative uncertainty of 0.3% at $p_\textrm{T} = 300$ GeV and 0.6% at 4 TeV. The jet energy calibration is also derived with the single-particle calorimeter response measurements separately for quark- and gluon-induced jets and furthermore for jets with R jet varying from 0.2 to 1.0 retaining the correlations between these measurements. Differences between inclusive jets and jets from boosted top-quark decays, with and without grooming the soft jet constituents, are also studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

An improved pulse-height analyzer for energetic particle measurements in the upper atmosphere

An energetic particle spectrometer for measurements in the upper atmosphere by rocket is described. The system has two methods of processing data. One is a staircase generator using threshold detectors; the other is a peak detector. The system incorporates a logarithmic converter for better resolution at low amplitudes and better use of telemetry channels. The circuits are described and calibration procedures are given. Modifications are recommended for high flux environments. Appendices cover sampling error in the peak detector and modifications made to the receiver of the propagation experiment.

Dean, L.↗

Solar photospheric and coronal abundances from solar energetic particle measurements

Observations of solar energetic particles (SEP) from 22 solar flares in the 1977 to 1982 time period are reported. SEP abundances were obtained for all elements with 3 approximately less than Z approximately less than 30 except Li, Be, B, F, Sc, v, Co and Cu for which upper limits were obtained. Statistically meaningful abundances of several rare elements (P, Cl, K, Ti, and Mn) were determined for the first time, and the average abundance of the more abundant elements were determined with improved precision.

Breneman, H.↗

Optical Particle Measurements during EPCAPE Field Campaign Report

This campaign requested the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility optical particle counter (OPC) at the first ARM Mobile Facility (AMF1) located at the Scripps Pier in La Jolla, California during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE). The addition of the OPC was requested for two reasons. (1) Close the gap between the scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) size distribution from the Aerosol Observing System (AOS) measurements. (2) Principal investigator Petters has been working with Tracking Aerosol Convection Interaction Experiment (TRACER) data to compute particle fluxes from Doppler lidar (Petters et al. 2024). Briefly, backscatter flux is obtained using the eddy covariance technique using the Doppler vertical velocity and attenuated backscatter. Building upon prior studies, we were able to relate backscatter to particle number concentration by calibrating the lidar retrievals against optical particle counter-measured ground-based aerosol size distribution and radiosonde-interpolated relative humidity at lidar sample height. Performing similar analysis was of interest to EPCAPE to better understand the emissions and vertical transport of large particles into the overlying stratus clouds. However, as stated above, this analysis requires an optical size distribution that covers the 0.3-30-μm-diameter size range. The OPC was deployed between 2023-04-14 and 2024-02-14. The deployment, data quality analysis, and data archiving was handled by the DOE ARM instrument mentor team without additional involvement by the principal investigator. Data quality was marked as “routine” for the majority of the campaign.

54 ENVIRONMENTAL SCIENCES↗