Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pinhole optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A laser-based sizing/velocimetry technique to investigate the secondary atomization of aluminum gel propellants

A laser-based, forward-scatter diagnostic technique, employing a single laser sheet, has been developed to simultaneously measure the size and velocity of individual 10-150 micron droplets in a dilute polydisperse droplet stream (less than 1000 particles/cc) and to detect the presence of burning aluminum in these same droplets. Spectral emission from aluminum vapor in the 390-400 nm wavelength region is used as an indication of burning aluminum. The technique utilizes a 4-mm uniformly illuminated probe volume, eliminating trajectory-dependent particle sizing and size-dependent system detection bias. Particle sizing is based on a correlation of particle size with near-forward scattered light intensity. Calculations show average particle sizing variation to be within 3.5% over the expected range of refractive indices. Calibrations using a range of optical pinholes (10-100 micron) were used to verify the above sizing correlation.

Mueller, D. C.↗

Pinhole X-ray/coronagraph optical systems concept definition study

The Pinhole X-ray/Coronagraph Concept utilizes the long baselines possible in Earth orbit with the space transportation system (shuttle) to produce observations of solar X-ray emission features at extremely high spatial resolution (up to 0.1 arc second) and high energy (up to 100 keV), and also white light and UV observations of the inner and outer corona at high spatial and/or spectral resolution. An examination of various aspects of a preliminary version of the X-ray Pinhole/Coronagraph Concept is presented. For this preliminary version, the instrument package will be carried in the shuttle bay on a mounting platform, and will be connected to the occulter with a deployable boom such as an Astromast. Generally, the spatial resolution, stray light levels, and minimum limb observing angles improve as the boom length increases. However, the associated engineering problems also become more serious with greater boom lengths.

Zehnpfenning, T. F.↗

A real time interferometry system for unsteady flow measurements

A simple real-time interferometer system was developed for use in dynamic stall and other unsteady flow research at compressible flow speeds. A conventional schlieren system was modified to operate as a point diffraction interferometer. The implementation of this interferometer is discussed, and results of trials with different point diffractors are presented in this paper. The performance of the interferometer under various flow conditions was investigated. Results are presented which show the effects of the interferometer parameters such as pinhole size and pinhole-plate optical density on the performance of the system.

Brock, N. J.↗

Solar Rotating Fourier Telescope

Proposed telescope based on absorbing Fourier-transform grids images full Sun at unprecedented resolution. Overcomes limitations of both conventional optical and pinhole cameras. Arrays of grids and detectors configured for sensitivity to selected fourier components of x-ray images.

Campbell, Jonathan↗

Tomographic and analog 3-D simulations using NORA

The results of two computer simulations demonstrate the feasibility of using the nonoverlapping redundant array (NORA) to form three-dimensional images of objects with X-rays. Pinholes admit the X-rays to nonoverlapping points on a detector. The object is reconstructed in the analog mode by optical correlation and in the digital mode by tomographic computations. Trials were run with a stick-figure pyramid and extended objects with out-of-focus backgrounds. Substitution of spherical optical lenses for the pinholes increased the light transmission sufficiently that objects could be easily viewed in a dark room. Out-of-focus aberrations in tomographic reconstruction could be eliminated using Chang's (1976) algorithm.

Yin, L. I.↗

Optical Geolocation for Small Unmanned Aerial Systems

This paper presents an airborne optical geolocation system using four optical targets to provide position and attitude estimation for a sUAS supporting the NASA Acoustic Research Mission (ARM), where the goal is to reduce nuisance airframe noise during approach and landing. A large precision positioned microphone array captures the airframe noise for multiple passes of a Gulfstream III aircraft. For health monitoring of the microphone array, the Acoustic Calibration Vehicle (ACV) sUAS completes daily flights with an onboard speaker emitting tones at frequencies optimized for determining microphone functionality. An accurate position estimate of the ACV relative to the array is needed for microphone health monitoring. To this end, an optical geolocation system using a downward facing camera mounted to the ACV was developed. The 3D positioning of the ACV is computed using the pinhole camera model. A novel optical geolocation algorithm first detects the targets, then a recursive algorithm tightens the localization of the targets. Finally, the position of the sUAS is computed using the image coordinates of the targets, the 3D world coordinates of the targets, and the camera matrix. A Real-Time Kinematic GPS system is used to compare the optical geolocation system.

Dolph, Chester V.↗

Achromatical Optical Correlator

Signal-to-noise ratio exceeds that of monochromatic correlator. Achromatical optical correlator uses multiple-pinhole diffraction of dispersed white light to form superposed multiple correlations of input and reference images in output plane. Set of matched spatial filters made by multiple-exposure holographic process, each exposure using suitably-scaled input image and suitable angle of reference beam. Recording-aperture mask translated to appropriate horizontal position for each exposure. Noncoherent illumination suitable for applications involving recognition of color and determination of scale. When fully developed achromatical correlators will be useful for recognition of patterns; for example, in industrial inspection and search for selected features in aerial photographs.

Chao, Tien-Hsin↗

Micron-Accurate Laser Fresnel-Diffraction Ranging System

Two versions of an optoelectronic system undergoing development are depicted. The system is expected to be capable of measuring a distance between 2 and 10 m with an error of no more than 1 micrometer. The system would be designed to exploit Fresnel diffraction of a laser beam. In particular, it would be designed to take advantage of the fact that a Fresnel diffraction pattern is ultrasensitive to distance. The two versions would differ in the following respects: In version 1, the focus of the telescope would be in the Fresnel region, and the telescope would have a small depth of focus. As a consequence, the Fresnel pattern would be imaged directly onto the photodetector array; in version 2, a multielement lens module would displace the Fresnel region from the vicinity of the pinhole to the vicinity of the optical receiver. As the distance to be measured varied, the location of the receiver relative to the displaced Fresnel-diffraction region would vary, thereby causing the Fresnel diffraction pattern on the focal plane to vary. The multielement lens module would also correct for aberrations. The processing of the digitized Fresnel diffraction pattern in the computer might be accelerated by using only parts of the pattern or even only one small part - the central pixel. As the distance from the pinhole increased, the central pixel would rapidly cycle between maximum and minimum light intensity. This in itself would not be sufficient to uniquely determine the distance. However, by varying the size of the pinhole or the wavelength of the laser, one could obtain a second cycle of variation of intensity that, in conjunction with the first cycle, could enable a unique determination of distance. Alternatively, for a single wavelength and a single pinhole size, it should suffice to consider the data from only two different key pixels in the Fresnel pattern.

Lehner, David↗

Analysis of surfaces from the LDEF A0114, phase 4

Progress made from 1 Mar. to 31 Aug. 1991 is presented. The work concentrated on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopic (XPS) analysis of some samples. The following papers are presented: (1) observation of Be-7 on the surface of the Long Duration Exposure Facility (LDEF) Spacecraft; (2) measurement of the passive attitude control performance of a recovered spacecraft; (3) effects on LDEF exposed copper flim and bulk; (4) measurements of erosion characteristics for metal and polymer surfaces using profilometry; (5) the interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces; (6) pinhole cameras as sensors for atomic oxygen in orbit; and (7) interaction of atomic oxygen with solid surfaces in low earth orbit- results from LDEF experiment A0114.

Gregory, John C.↗

Analysis of surfaces from the LDEF A0114, phase 2

Analysis of surfaces from the Long Duration Exposure Facility (LDEF) continued during the reporting period. Work has continued on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopy (XPS) analysis of some samples. Papers that have appeared or have been accepted for publications are listed. Several of these papers and an abstact are included.

Gregory, John C.↗

Analysis of surfaces from the LDEF A0114, phase 2

During the reporting period, work continued on profilometry measurements of eroded and corroded sample surfaces, optical transmission measurements, analysis of the pinhole camera, and x-ray photoelectron spectroscopy (XPS) analysis of some samples. Among metal samples, copper showed some interesting new results. There were two forms of copper samples: a thin film sputter-coated on fused silica and a solid piece of OFHC copper. They were characterized by x-ray and Auger electron spectroscopies, x-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to demonstrate the presence of Cu2O and CuO and to determine the oxidation states.

Gregory, John C.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Pinhole Calibrator For Particle-Sizing Instrument

Rotating-pinhole calibrator designed for use in calibrating and testing optical instrument measuring sizes of cloud droplets, dust particles, and other small particles suspended in flowing air. Easily attachable to particle-size-measuring instrument and suitable for both quick verification of calibration in field and detailed calibration studies in laboratory. Calibrator used to determine such operating parameters of instrument as optical collection angles, depth of field, profile of laser beam used to measure particles, and response to trajectory of particle. Also used to align instrument. Pinhole reused any number of times without risk of variation in diffraction pattern. Furthermore, size of pinhole chosen precisely and at will.

Hovenac, Edward↗

Use of rotating pinholes and reticles for calibration of cloud droplet instrumentation

Calibration devices for the Forward Scattering Spectrometer Probe (FSSP) and the Optical Array Probe (OAP) were developed. The device used with the FSSP is a rotating pinhole calibrator. It utilizes light diffracted by a pinhole of a known diameter to simulate scattered light from a water droplet. This device can be used to calibrate the FSSP, measure the FSSP's optical collection angles and for instrument alignment and troubleshooting. The device used with the OAP is a rotating reticle calibrator. Chrome disks of a known diameter on the reticle are used for calibration of the OAP and for determining the OAP's response to out-of-focus particles in the probe volume.

Hovenac, Edward A.↗

Graphic design of pinhole cameras

The paper describes a graphic technique for the analysis and optimization of pinhole size and focal length. The technique is based on the use of the transfer function of optical elements described by Scott (1959) to construct the transfer function of a circular pinhole camera. This transfer function is the response of a component or system to a pattern of lines having a sinusoidally varying radiance at varying spatial frequencies. Some specific examples of graphic design are presented.

Edwards, H. B.↗

A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine.

Hoover, R. B.↗

Making Rectangular Apertures In Silicon

Conventional silicon micromachining techniques produce micrometer-sized rectangular apertures. Used to define source and detector openings for measurements of images and scattered light in visible, ultraviolet, and soft x-ray wavelength regions, and as general-purpose optical slits or slit arrays. Rectangular microscopic apertures replace circular pinholes made by puncturing foils with needles or by drilling foils with intense, highly-focused laser beams. Precise photolithography yields apertures of superior geometry.

Leviton, Douglas B.↗

Spacelab transitioning to Space Station

The availability of Shuttle and Spacelab makes it possible to fly a new class of scientific instruments. Thus, larger and heavier instruments can be employed, while the return of instruments after a mission provides an opportunity for instrument reconditioning and improvement in preparation for the next flight. In addition, the Shuttle provides a basic pointing capability with its Reaction Control System (RCS) which adjusts the attitude of the entire Shuttle in the desired direction. As part of Spacelab, the European Space Agency (ESA) developed an Instrument Pointing System (IPS). Early mission results are discussed, taking into account the first scientific payload carried on the Shuttle (OSTA-1), the OSS-1 payload, Spacelab 1, Spacelab 2, the Astro payload, Sunlab, and OSTA-3. Future missions are also considered, giving attention to the Solar Optical Telescope (SOT), the Shuttle Infrared Telescope Facility (SIRTF), and the Pinhole Occulter Facility (POF). It is pointed out that a number of the instruments being developed can be modified for operation on the Space Station.

Benson, R. H.↗