Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polymer glasses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comment on Comment on “Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments”*

Abstract Cangialosi, Alegría, and Colmenero have made a comment on a paper of ours [Polym. Eng. Sci. 2022:1–13], in which we discussed the concern that the enthalpy recovery data reported by Cangialosi and co‐workers [Phys. Rev. Lett. 2013;111(9):095701] for polystyrene aged up to 15 K below glass transition temperature was anomalous and contradicted existing experimental results from the literature over a similar range of aging conditions. Their response shifts the focus away from the raised questions about their experimental results and attempts to invalidate the data that we cited in support of our argument. Here we respond to the comment and add additional analysis that suggests the structural recovery response of glassy materials exhibits smooth behavior over the full range of measurements, up to 7 or 8 logarithmic decades. We do this by referring to the work on the intrinsic isotherm down‐jump and memory responses of poly(vinyl acetate) between 40°C and 15°C over six logarithmic decades by Kovacs [Fortsch. Hochpolym. Fo. 1963;3(1/2):394–508], the small‐strain tensile creep of poly(vinyl chloride) quenched from 90°C to 40°C (approximately 40°C below T g ) over seven logarithmic decades from Struik [Polym Eng. Sci., 1977;17:165–173], and the volume recovery behavior for aging times up to 3 months in a temperature range between 95°C and −50°C by Greiner and Schwarzl [Rheol. Acta. 1984;23(4):378–395]. We also add discussion that an isothermal aging procedure using a vacuum oven is highly vulnerable to temperature errors due to the problem of good temperature control when the heat transfer mechanism is primarily radiative.

Jin, Shuang↗

Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments*

Abstract There is considerable interest in data reported by Cangialosi et al. [Cangialosi, D., Boucher, V. M., Alegría, A., & Colmenero, J. (2013). Physical Review Letters , 111 (9), 095701] that purportedly showed unusual irregular responses in the isothermal structural recovery behavior of glasses because the observation challenges the general view of the dynamics being smooth functions of time as observed in extensive dilatometric experiments by Kovacs [Kovacs, A. J. (1964). In Fortschritte der Hochpolymeren‐Forschung , 3 , 394–507. Springer, Berlin, Heidelberg.] in the 1960s. The reported data show an apparent two mechanism structural (enthalpy) recovery at aging temperatures ranging from 6 to 17 K below which is also controversial as it could not be reproduced in work from Koh and Simon [Koh, Y. P., & Simon, S. L. (2013). Macromolecules , 46(14), 5815–5821.] where a second plateau observed in the enthalpy loss curve was not reproduced in nearly 1‐year‐long experiments at 15 K below . Therefore, it is important to determine what might be possible reasons for the apparent non‐smooth relaxations. Here, we examine the possibility that the poor temperature control of a typical vacuum oven could explain the anomalous results. We used the Tool–Narayanaswamy–Moynihan (TNM) model of structural recovery to calculate the effect of typical vacuum oven temperature variation on the structural recovery of polystyrene and find that we can reproduce the reported experimental results. The issue of temperature control using a vacuum oven is discussed, and data from thermocouple measurements of temperature at various locations inside a vacuum oven are shown.

36 MATERIALS SCIENCE↗

An overview of the nonequilibrium behavior of polymer glasses

It is pointed out that research efforts are at present being directed in two areas, one comprising experimental studies of this phenomenon in various glassy polymer systems and the other involving the development of a quantitative theory capable of satisfactorily predicting aging behavior for a variety of polymer materials under different conditions. Recent work in both these areas is surveyed. The basic principles of nonequilibrium behavior are outlined, with emphasis placed on changes in material properties with annealing below the glass transition temperature. Free volume theory and thermodynamic theory are discussed.

Tant, M. R.↗

Leveraging the Polymer Glass Transition to Access Thermally Switchable Shear Jamming Suspensions

Suspensions of polymeric nano-and microparticles are fascinating stress-responsive material systems that, depending on their composition, can display a diverse range of flow properties under shear, such as drastic thinning, thickening, and even jamming (reversible solidification driven by shear). However, investigations to date have almost exclusively focused on nonresponsive particles, which do not allow in situ tuning of the flow properties. Polymeric materials possess rich phase transitions that can be directly tuned by their chemical structures, which has enabled researchers to engineer versatile adaptive materials that can respond to targeted external stimuli. Reported herein are suspensions of (readily prepared) micrometer-sized polymeric particles with accessible glass transition temperatures (T g ) designed to thermally control their non-Newtonian rheology. The underlying mechanical stiffness and interparticle friction between particles change dramatically near T g . Capitalizing on these properties, it is shown that, in contrast to conventional systems, a dramatic and nonmonotonic change in shear thickening occurs as the suspensions transition through the particles' T g . This straightforward strategy enables the in situ turning on (or off) of the system's ability to shear jam by varying the temperature relative to T g and lays the groundwork for other types of stimuli-responsive jamming systems through polymer chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of circular polymer-glass fabric composites

Potentially automated pultrusion technique has been provided for production of curved, glass-reinforced polyimide, epoxy, and graphite reinforced structures. Specially designed apparatus has been manufactured for production of curved structures.

Hardesty, E. E.↗

Cracks in Glass Polymers Induced by Solvent Absorption

Combination of soluble particles and absorbed solvents cause polymer cracking. New failure mechanism in glassy polymers identified. Cracking caused by presence of particles insoluble in polymer matrix but soluble in solvent. Experiments performed and equations describe cracking phenomenon set forth in concise report.

Fedors, R. F.↗

Applying machine learning and quantum chemistry to predict the glass transition temperatures of polymers

Glass transition temperature (T g ) is important for understanding the physical and mechanical properties of a polymer material because it relates to the thermal energy required to transition between a hard glassy state and a soft rubbery one. Over the years, various models have been developed for predicting this thermal property from molecular structure to aid in designing novel polymers in selected classes. This work builds on those efforts by utilizing both machine learning (ML) and quantum chemistry (QC) techniques to develop models that can predict T g values from the molecular structure under different data availability scenarios and for a wide variety of polymer types. For the ML model, a graph convolutional network (GCN) was used to map topological polymer features; this model was trained against a dataset of more than 7500 T g values and resulted in a root mean square error (RMSE) of 38.1 °C. The QC-based regression model was trained on 83 T g values and produced an RMSE of 34.5 °C. In conclusion, this work demonstrated that while both model techniques produce accurate predictions and are suitable for different data availability scenarios, the QC-based regression model offered a more interpretable model framework with significantly less training data.

36 MATERIALS SCIENCE↗

Cracking during pyrolysis of preceramic polymers within glass microtubes

Abstract Cracking of preceramic polymers during pyrolysis under highly‐constrained conditions is examined by X‐ray computed tomography of fine glass microtubes containing the pyrolyzing material. The microtubes represent model geometries that mimic the long channels between fibers during production of ceramic composites by precursor impregnation and pyrolysis. Complementary fracture mechanics analyses of interface cracking and crack kinking are used to glean insights into the conditions under which periodic alternating cracks form. A key finding is that alternating cracks are an inherent feature of constrained pyrolysis . This feature is attributable in large part to the high energy release rates for interface cracks to kink into the pyrolyzing material under the hydrostatic tension developed during pyrolysis. It also requires interfaces with toughness comparable to that of the pyrolyzing material, to prevent large‐scale interface separation. The results further indicate the need for small uniform spaces for pyrolysis within fiber preforms in order to produce networks of fine periodic pyrolysis cracks; these networks in turn facilitate impregnation and pyrolysis in subsequent processing cycles.

Larson, Natalie M.↗

Constitutive Model Development for Aging Polymer Encapsulants (ASC P&EM FY2021 L2 Milestone 7836)

This SAND report fulfills the completion requirements for the ASC Physics and Engineering Modeling Level 2 Milestone 7836 during Fiscal Year 2021. The Sandia Simplified potential energy clock (SPEC) non-linear viscoelastic constitutive model was developed to predict a whole host of polymer glass physical behaviors in order to provide a tool to assess the effects of stress on these materials over their lifecycle. Polymer glasses are used extensively in applications such as electronics packaging, where encapsulants and adhesives can be critical to device performance. In this work, the focus is on assessing the performance of the model in predicting material evolution associated with long-term physical aging, an area that the model has not been fully vetted in. These predictions are key to utilizing models to help demonstrate electronics packaging component reliability over decades long service lives, a task that is very costly and time consuming to execute experimentally. The initiating hypothesis for the work was that a model calibration process can be defined that enables confidence in physical aging predictions under ND relevant environments and timescales without sacrificing other predictive capabilities. To test the hypothesis, an extensive suite of calibration and aging data was assembled from a combination of prior work and collaborating projects (Aging and Lifetimes as well as the DoD Joint Munitions Program) for two mission relevant epoxy encapsulants, 828DGEBA/DEA and 828DGEBA/T403. Multiple model calibration processes were developed and evaluated against the entire set of data for each material. A qualitative assessment of each calibration's ability to predict the wide range of aging responses was key to ranking the calibrations against each other. During this evaluation, predictions that were identified as non-physical, i.e., demonstrated something that was qualitatively different than known material behavior, were heavily weighted against the calibration performance. Thus, unphysical predictions for one aspect of aging response could generate a lower overall rating for a calibration process even if that process generated better quantitative predictions for another aspect of aging response. This insurance that all predictions are qualitatively correct is important to the overall aim of utilizing the model to predict residual stress evolution, which will depend on the interplay amongst the different material aging responses. The DSC-focused calibration procedure generated the best all-around aging predictions for both materials, demonstrating material models that can qualitatively predict the whole host of different physical aging responses that have been measured. This step forward in predictive capability comes from an unanticipated source, utilization of calorimetry measurements to specify model parameters. The DSC-focused calibration technique performed better than compression-focused techniques that more heavily weigh measurements more closely related to the structural responses to be predicted. Indeed, the DSC-focused calibration procedure was only possible due to recent incorporation of the enthalpy and heat capacity features into SPEC that was newly verified during this L2 milestone. Fundamentally similar aspects of the two material model calibrations as well as parametric studies to assess sensitives of the aging predictions are discussed within the report. A perspective on the next steps to the overall goal of residual stress evolution predictions under stockpile conditions closes the report.

36 MATERIALS SCIENCE↗

Insulation or Irradiance: Exploring Why Bifacial Photovoltaics Run Hot

Bifacial photovoltaics are predicted to become the dominant device architecture over the next couple of years, but their thermal performance is not yet well understood. In this study, we model the thermal effects of different backside lamination materials on the performance of bifacial PERC cells. Glass-glass laminated cells were found to operate hotter than equivalent glass-polymer backsheet packed cells. This was solely due to the increased absorption of rear side incident light.

bifacial↗

Feasibility of Metal Oxide Glasses and Polymer Membranes as Sorbents for Gaseous Oxidized Mercury

Mass spectrometry methods are currently under development by the atmospheric mercury (Hg) research community to elucidate the identity of atmospheric oxidized mercury (Hg II ) compounds. Due to high instrument detection limits, materials that can quantitatively preconcentrate atmospheric Hg II without facilitating compound-altering chemical reactions are needed to support these methods. Cation exchange membranes (CEM) and nylon membranes are currently used to preconcentrate ambient Hg II for concentration measurements and Hg II compound estimation, respectively. However, CEM and nylon membranes are poor candidates for observations by mass spectrometry methods due to release of interfering compounds upon heating; glasses do not have this problem. Here, three metal oxide glasses were explored as potential alternatives for Hg II preconcentration for future use with mass spectrometry methods: calcium phosphate (CaP), iron phosphate (FeP), and calcium aluminate (CaAl). The glasses demonstrated quantitative selective capture of HgBr 2 without capture of Hg 0 . Under ambient conditions, the CaP, FeP, and CaAl sorbed 36.4 ± 12.6% of the total HgII as the CEM. However, when Hg concentrations were normalized to surface area, CaP, FeP, and CaAl sorbed more HgBr 2 in the laboratory and ambient HgII compared to CEM. The CEM and CaP retained similar concentrations of HgBr 2 when preloaded samples were deployed in the field. Additionally, a permeation tube-based calibrator was used to load sorbents with HgBr 2 for investigation of HgII retention on CEM and thermal desorption profile changes on nylon membranes during active sampling. Nylon membranes were purchased from three vendors and used to compare HgBr 2 retention; a different HgBr 2 thermal desorption profile was achieved for each vendor’s nylon membrane.

Amides↗