Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pool Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sodium Pool Fire Phenomena, Sodium Pool Fire Modeling in SOFIRE II, and SOFIRE II Calculations for the AFR-100

The SOFIRE II computer code for the calculation of sodium pool fires has been obtained from the Reactor Safety Information Computational Center and the SOFIRE II ONE CELL version has been implemented at Argonne National Laboratory (ANL). A critical review of literature relevant to sodium pool fires has been carried out with the objectives of understanding sodium pool fire phenomena and how well specific phenomena are modeled or neglected in SOFIRE II. Significant predictions about sodium pool fires can be made on the basis of first principles analyses alone making use of the existing experiment database and knowledge base. In implementing SOFIRE II ONE CELL, minor modifications were necessary to compile and execute the code on a personal computer (PC) and to verify the results of the test case problem. The code was applied to the AFR-100 Sodium-Cooled Fast Reactor (SFR) design to calculate a sodium pool fire following a postulated failure of the sodium storage vessel of one of the four intermediate sodium heat transport circuits and the subsequent release of sodium onto the floor of the steel-lined compartment in which the sodium storage vessel is located. SOFIRE II calculates that only a small fraction of the released sodium burns due to the rapid consumption of the available oxygen inside of the closed compartment. The preliminary results demonstrate the effects of the heat sinks provided by the compartment floor, walls, and ceiling in reducing the temperature of the sodium pool with time.

Sienicki, James J.↗

Validation study of sodium pool fire modeling efforts in $\mathrm{MELCOR}$ and $\mathrm{SPHINCS}$ codes

Discharge of sodium coolant into containment from a sodium-cooled fast reactor vessel can occur in the event of a pipe leak or break. In this situation, some of the liquid sodium droplets discharged from the coolant system will react with oxygen in the air before reaching the containment. This phase of the event is normally termed the sodium spray fire phase. Unreacted sodium droplets pool on the containment floor where continued reaction with containment atmospheric oxygen occurs. This phase of the event is normally termed the sodium pool fire phase. Both phases of these sodium-oxygen reactions (or fires) are important to model because of the heat addition and aerosol generation that occur. Any fission products trapped in the sodium coolant may also be released during this progression of events, which if released from containment could pose a health risk to workers and the public. The paper describes progress of an international collaborative research in the area of the sodium fire modeling in the sodium-cooled fast reactors between the United States and Japan under the framework of the Civil Nuclear Energy Research and Development Working Group. In this collaboration between Sandia National Laboratories and Japan Atomic Energy Agency, the validation basis for and modeling capabilities of sodium spray and pool fires in MELCOR of Sandia National Laboratories and SPHINCS of Japan Atomic Energy Agency are being enhanced. Here this study documents MELCOR and SPHINCS sodium pool fire model validation exercises against the JAEA’s sodium pool fire experiments, F7-1 and F7-2. The proposed enhancement of the sodium pool fire models in MELCOR through addition of thermal hydraulic and sodium spreading models that enable a better representation of experimental results is also described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fire control method and analytical model for large liquid hydrocarbon pool fires

The dominate parameter governing the behavior of a liquid hydrocarbon (JP-5) pool fire is wind speed. The most effective method of controlling wind speed in the vicinity of a large circular (10 m dia.) pool fire is a set of concentric screens located outside the perimeter. Because detailed behavior of the pool fire structure within one pool fire diameter is unknown, an analytical model supported by careful experiments is under development. As a first step toward this development, a regional pool fire model was constructed for the no-wind condition consisting of three zones -- liquid fuel, combustion, and plume -- where the predicted variables are mass burning rate and characteristic temperatures of the combustion and plume zones. This zone pool fire model can be modified to incorporate plume bending by wind, radiation absorption by soot particles, and a different ambient air flow entrainment rate. Results from the zone model are given for a pool diameter of 1.3 m and are found to reproduce values in the literature.

Fenton, D. L.↗

Numerical investigation of mixing and heat transfer in a 7.9 m JP-8 pool fire

The response of objects engulfed in, and adjacent to, large-scale pool fires is of interest in accident and safety assessments. In this study, Fuego, a low-Mach turbulent reacting flow code was used to study conjugate heat transfer in a 7.9 m diameter JP-8 pool fire. Simulations were designed to replicate past experimental measurements (Blanchat et al., 2006) of incident heat flux to three cylindrical calorimeters in and around the pool fire. Two turbulent combustion models were compared directly - the eddy dissipation concept and a more recently developed unsteady flamelet model. First and second order spatial and temporal discretization schemes were also compared to assess the performance of low-dissipation numerical operators. Heat flux predictions to the transportation size calorimeter outside the fire were within experimental uncertainties. Inside the fire, experimental measurements were higher than predicted values and may have been a consequence of soot deposition and augmented participating media radiation from soot and fuel vapor. Simulation predictions improved in cases where turbulent kinetic energy and mixing were more resolved. This work, and others referenced herein, suggest that spatial resolution on the order of 0.5–1.0 cm may be required to fully resolve fluid instabilities, vortex production between fire plumes and crosswind, soot production, and fuel-air mixing. This presents a substantial computational challenge for safety assessments of engulfed objects in fully turbulent pool fires.

Conjugate heat transfer↗

High resolution numerical simulations of methane pool fires using adaptive mesh refinement

The ability to accurately predict the structure and dynamics of pool fires using computational simulations is of great interest in a wide variety of applications, including accidental and wildland fires. However, the presence of physical processes spanning a broad range of spatial and temporal scales poses a significant challenge for simulations of such fires, particularly at conditions near the transition between laminar and turbulent flow. Here, in this study, we examine the transition to turbulence in methane pool fires using high-resolution simulations with multi-step finite rate chemistry, where adaptive mesh refinement (AMR) is used to directly resolve small-scale flow phenomena. We perform three simulations of methane pool fires, each with increasing diameter, corresponding to increasing inlet Reynolds and Richardson numbers. As the diameter increases, the flow transitions from organized vortex roll-up via the puffing instability to much more chaotic mixing associated with finger formation along the shear layer and core collapse near the inlet. These effects combine to create additional mixing close to the inlet, thereby enhancing fuel consumption and causing more rapid acceleration of the fluid above the pool. We also make comparisons between the transition to turbulence and core collapse in the present pool fires and in inert helium plumes, which are often used as surrogates for the study of buoyant reacting flows.

42 ENGINEERING↗

Large-scale pool fire test recommendations

The important aspects of external pool fires are outlined. The research objectives are: (1) determine heat flux to surfaces as a function of pool size (convective and radiative heat flux); (2) obtain information that can be compared with theoretical models for radiative flux in the near field; and (3) predict radiative heat flux for arbitrary pool size. The measurements and instrumentation (calorimeters and thermocouples) used for pool fires are outlined.

Bankston, C. P.↗

Pool Fire Analysis Methodology for Assessing Damage to Waste Containers

This document provides guidelines, whereby the physical parameters associated with postulated flammable/combustible liquid pool fires are determined (thermal analysis) in order to estimate the number of waste containers impacted. Pool fire damage to waste containers may occur due to a container being fully engulfed (within the periphery of the pool), partially engulfed, or within the critical heat flux distance. The methodology described here for estimating the size of the pool fire is developed using spill characteristics outlined in Chapter 65 of the SFPE Handbook (Ref. 7) and testing done by Hansen (Ref. 25). For exposures, the critical flux height is determined using the detailed method of Shokri and Beyler (Ref. 8) from the flame height, calculated as described by Heskestad (Ref. 7) and the average black body emissive power, determined using the method of Shokri and Beyler (Ref. 8). Three types of liquid pool fires should be considered; unconfined crash/instantaneous spill fires, unconfined continuously flowing (also called metered leak) spill fires, and confined spill fires. All fuel sources should be considered consistent with the facility Fire Hazard Analysis (FHA). However, the most likely liquid fuel sources present in TRU waste facilities are those present on TRU waste handling vehicles (forklifts, pallet movers, transport trucks, etc.). This method can also be used for assessing damage to items other than waste containers or other methods of analysis may be used with appropriate justification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations on the Prediction of Thermal Hazard Distances from Large Liquefied Natural Gas Pool Fires on Water for Solid Flame Models

The objective of this work is to provide recommendations on predicting thermal hazard distances resulting from large liquefied natural gas (LNG) pool fires on water. The recommendations pertain to an integral model approach and its pertinent parameters such as burn rate, flame height, surface emissive power (SEP), and transmissivity. These recommendations are based upon knowledge gained from conducting experiments of LNG pool fires on water at Sandia National Laboratories in New Mexico in 2009 in addition to earlier, smaller scale tests. The 83 diameter meter test resulted in a 56 m diameter pool fire which is the largest LNG pool fire test performed on water or land to date.

Luketa, Anay Josephine↗

Fuels Characterization for National Research Council Canada 2-m Pool Fire Test Series

This report provides a detailed analysis of the physical and chemical properties of three liquid hydrocarbon fuels: heptane, Bakken crude, and a diluted bitumen, that were subsequently tested in a series of 2-m pool fire experiments at Sandia National Laboratories for the National Research Council Canada. Properties such as relative density, vapor pressure (VPCR x ), composition, and heat of combustion were evaluated. The heptane analysis, with relative density = 0.69 (at 15°C), confirmed that the material tested was consistent with high-purity (>99%) n-heptane. The Bakken crude, with a relative density = 0.81 (at 15°C), exhibited a vapor pressure by VPCR 0.2 (37.8°C) in the range 120-157 kPa. The dilbit, with a relative density = 0.92 (at 15°C) exhibited a vapor pressure by VPCR 0.2 (37.8°C) in the range 85-98 kPa. Solids remaining in the test pans after the pool fires were also collected and weighed. No detectable solids were left after the heptane burns. In contrast, the crude oils left some brittle, black solid residue. On average, dilbit pool fires left about 40 more residue by mass than Bakken pool fires for equivalent mass of fuel feed.

01 COAL, LIGNITE, AND PEAT↗

Pool Fire and Fireball Experiments in Support of the US DOE/DOT/TC Crude Oil Characterization Research Study

This report describes an experimental study of physical, chemical, and combustion characteristics of selected North American crude oils, and how these associate with thermal hazard distances resulting from pool fires and fireballs. The emergence of large volumes of tight oils within the North American Transportation system over the last decade coupled with several high-profile train accidents involving crude oils, has raised questions about the role of oil properties in general, and tight oils in particular, in affecting the severity of hazard outcomes in related crude oil fires. The objective of the pool fire experiments is to measure parameters necessary for hazard evaluation, namely, burn rate, surface emissive power, flame height, and heat flux to an engulfed object. To carry out this objective, a series of 2-m diameter indoor and 5-m diameter outdoor experiments were performed. The objective of the fireball experiments is to measure parameters required for hazard evaluation which include fireball maximum diameter, height at maximum diameter, duration, and surface emissive power using 400-gallons of crude oil per test. The crude oil samples used for the experiments were obtained from several U.S. locations, including including “tight” oils from the Bakken region of North Dakota and Permian region of Texas, and a conventionally produced oil from the U.S. Strategic Petroleum Reserve stockpile. These samples spanned a measurable range of vapor pressure (VPCR x (T)) and light ends content representative of U.S. domestic conventional and tight crudes. The results indicate that all the oils tested here have comparable thermal hazard distances and the measured properties are consistent with other alkane-based hydrocarbon liquids. The similarity of pool fire and fireball burn characteristics pertinent to thermal hazard outcomes of the three oils studied indicate that vapor pressure is not a statistically significant factor in affecting these outcomes. Thus, the results from this work do not support creating a distinction for crude oils based on vapor pressure with regards to these combustion events.

02 PETROLEUM↗

Effect of soot concentration on radiative transport in a 2 m JP-8 pool fire

Hubbard et al. (2024) investigated conjugate heat transfer in a 7.9 m JP-8 pool fire, utilizing both heavily sooting and non-sooting fuel models. Their findings indicated that all models produced pool radiative heat fluxes within the measurement uncertainty for large-scale outdoor experiments. This study aims to further investigate the influence of soot concentration on radiative transport. To this end, Large Eddy Simulations (LES) of a 2 m diameter JP-8 pool fire were conducted, employing four turbulent combustion chemistry models: the Eddy Dissipation Concept (EDC) and three variants of flamelet model. Additionally, three variations of the one-equation subgrid scale turbulence kinetic energy model, and multiple mesh resolutions were utilized. The primary validation metrics were pool radiative heat flux and plume radiative fraction, with simulation data compared to experimental results published by Blanchat et al. (2010). The EDC model produced high soot concentrations near the pool surface, resulting in a significant shielding effect. In contrast, the flamelet combustion model has different kinetic limiters for soot production, leading to soot formation higher in the flame, where it can be more readily oxidized. Flamelet models incorporating both acetylene and benzene contributions to soot growth demonstrated better agreement with experimental data. To assess the sensitivity of pool radiative heat flux to soot mass concentration, we used a one-dimensional approximation over a wide range of soot concentrations and compared it to three-dimensional solutions obtained using Discrete Ordinates. Furthermore, this analysis illustrates the impacts of soot shielding and Turbulence Radiation Interactions (TRI), with TRI emission enhancement factors predicted to be in the range of 3–5 near the edges of the plume.

Computational fluid dynamics↗

Study of Radiative Heat Transfer and Flow Physics from Medium-scale Methanol Pool Fire Simulations [Slides]

Analysis of methanol pool fire conducted as part of validation study for SIERRA/Fuego. Radiation model was effectively calibrated by modifying radiation model parameters for methanol. Computing integrated buoyancy flux, entrainment rate, and turbulent kinetic energy allowed for evaluation of less typical quantities in this validation study. Quantities were compared with experimental data or correlations and generally showed agreement. TKE needed fine mesh to be computed accurately. Predicted flame height less sensitive to variations in mixture fraction than temperature. Mixture fraction is a preferable threshold variable for this application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation Assessment of Turbulent Reacting Flow Model Using The Area-Validation Metric on Medium-Scale Methanol Pool Fire Results

Accident analysis and ensuring power plant safety are pivotal in the nuclear energy sector. Significant strides have been achieved over the past few decades regarding fire protection and safety, primarily centered on design and regulatory compliance. Yet, after the Fukushima accident a decade ago, the imperative to enhance measures against fire, internal flooding, and power loss has intensified. Hence, a comprehensive, multilayered protection strategy against severe accidents is needed. Consequently, gaining a deeper insight into pool fires and their behavior through extensive validated data can greatly aid in improving these measures using advanced validation techniques. A model validation study was performed at Sandia National Laboratories in which a 30-cm diameter methanol pool fire was modeled using the SIERRA/Fuego turbulent reacting flow code. This validation study used a standard validation experiment to compare model results against, and conclusions have been published. The fire was modeled with a Large Eddy Simulation (LES) turbulence model with subgrid turbulent kinetic energy closure. Combustion was modeled using a strained laminar flamelet library approach. Radiative heat transfer was accounted for with a model utilizing the gray-gas approximation. In the present study, additional validation analysis is performed using the area validation metric (AVM). These activities are done on multiple datasets involving different variables and temporal/spatial ranges and intervals. In conclusion, the results provide insight into the use of the area validation metric on such temporally varying datasets and the importance of physics-aware use of the metric for proper analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Medium-Scale Methanol Pool Fire Model Validation

In this work, medium scale (30 cm diameter) methanol pool fires were simulated using the latest fire modeling suite implemented in Sierra/Fuego, a low Mach number multiphysics reacting flow code. The sensitivity of model outputs to various model parameters was studied with the objective of providing model validation. This work also assesses model performance relative to other recently published large eddy simulations (LES) of the same validation case. Two pool surface boundary conditions were simulated. The first was a prescribed fuel mass flux and the second used an algorithm to predict mass flux based on a mass and energy balance at the fuel surface. Gray gas radiation model parameters (absorption coefficients and gas radiation sources) were varied to assess radiant heat losses to the surroundings and pool surface. The radiation model was calibrated by comparing the simulated radiant fraction of the plume to experimental data. The effects of mesh resolution were also quantified starting with a grid resolution representative of engineering type fire calculations and then uniformly refining that mesh in the plume region. Simulation data were compared to experimental data collected at the University of Waterloo and the National Institute of Standards and Technology (NIST). Validation data included plume temperature, radial and axial velocities, velocity temperature turbulent correlations, velocity velocity turbulent correlations, radiant and convective heat fluxes to the pool surface, and plume radiant fraction. Additional analyses were performed in the pool boundary layer to assess simulated flame anchoring and the effect on convective heat fluxes. This work assesses the capability of the latest Fuego physics and chemistry model suite and provides additional insight into pool fire modeling for nonluminous, non-sooting flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planar measurements of soot volume fraction and OH in a JP-8 pool fire

The simultaneous measurement of soot volume fraction by laser induced incandescence (LII) and qualitative imaging of OH by laser induced fluorescence (LIF) was performed in a JP-8 pool fire contained in a 152 mm diameter pan. Line of sight extinction was used to calibrate the LII system in a laminar flame, and to provide an independent method of measuring average soot volume fraction in the turbulent flame. The presence of soot in the turbulent flame was found to be approximately 50% probable, resulting in high levels of optical extinction, which increased slightly through the flame from approximately 30% near the base, to approximately 50% at the tip. This high soot loading pushes both techniques toward their detection limit. Nevertheless, useful accuracy was obtained, with the LII measurement of apparent extinction in the turbulent flame being approximately 21% lower than a direct measurement, consistent with the influence of signal trapping. The axial and radial distributions of soot volume fraction are presented, along with PDFs of volume fraction, and new insight into the behavior of soot sheets in pool fires are sought from the simultaneous measurements of OH and LII. (author)

02 PETROLEUM↗

Laser-induced incandescence measurements of soot in turbulent pool fires

We present what we believe to be the first application of the laser-induced incandescence (LII) technique to large-scale fire testing. The construction of an LII instrument for fire measurements is presented in detail. Soot volume fraction imaging from 2 m diameter pool fires burning blended toluene/methanol liquid fuels is demonstrated along with a detailed report of measurement uncertainty in the challenging pool fire environment. Our LII instrument relies upon remotely located laser, optical, and detection systems and the insertion of water-cooled, fiber-bundle-coupled collection optics into the fire plume. Calibration of the instrument was performed using an ethylene/air laminar diffusion flame produced by a Santoro-type burner, which allowed for the extraction of absolute soot volume fractions from the LII images. Single-laser-shot two-dimensional images of the soot layer structure are presented with very high volumetric spatial resolution of the order of 10{sup -5} cm{sup 3}. Probability density functions of the soot volume fraction fluctuations are constructed from the large LII image ensembles. The results illustrate a highly intermittent soot fluctuation field with potentially large macroscale soot structures and clipped soot probability densities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗