Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger with Bypass Setpoint Temperature Control

Spacecraft radiators are sized for their maximum heat load in their warmest thermal environment, but must operate at reduced heat loads and in colder environments. For systems where the radiator environment can be colder than the working fluid freezing temperature, radiator freezing becomes an issue. Radiator freezing has not been a major issue for the Space Shuttle and the International Space Station (ISS) active thermal control systems (ATCSs) because they operate in environments that are warm relative to the freezing point of their external coolants (Freon-21 and ammonia, respectively). For a vehicle that lands at the Lunar South Pole, the design thermal environment is 215K, but the radiator working fluid must also be kept from freezing during the 0 K sink of transit. A radiator bypass flow control design such as those used on the Space Shuttle and ISS requires more than 30% of the design heat load to avoid radiator freezing during transit - even with a very low freezing point working fluid. By changing the traditional ATCS architecture to include a regenerating heat exchanger inboard of the radiator and by using a regenerator bypass flow control valve to maintain system setpoint, the required minimum heat load can be reduced by more than half. This gives the spacecraft much more flexibility in design and operation. The present work describes the regenerator bypass ATCS setpoint control methodology. It includes analytical results comparing the performance of this system to the traditional radiator bypass system. Finally, a summary of the advantages of the regenerator bypass system are presented.

Ungar, Eugene K.↗

Aerothermodynamic Analysis of a Flexible Thermal Protection System under Reentry Loads

The Carryall Block 1 reentry vehicle being developed by Outpost Space utilizes a strut supported semirigid deployable heatshield. This consists of a flexible thermal protection system, a heat-resistant fabric stack, stretched over actuated spars. The advantages of a deployable heatshield include reduced heat loading and earlier deceleration in the trajectory. However, the nature of the flexible thermal protection system necessitates considering the loaded shape of the heat shield. The flexible thermal protection system will deflect under reentry loads leading to areas of higher heating rates as well as a reduced axial coefficient as compared to the nominal shape. The Carryall Block 1 is analyzed using NASA’s FUN3D and DPLR CFD solvers with a deflected shape based on the catenary equations. The aerodynamic results are found to be within a percent for both solvers and both structured and unstructured mesh types. Fluid Structure Interaction (FSI) analysis is currently a work in progress, using file I/O to communicate between FUN3D and LS-DYNA, a commercial nonlinear structural solver. Challenges in deforming the geometry, mesh, and initial results are presented here.

thermal protection system↗

Thermal Design of Vapor Cooling of Flight Vehicle Structures Using LH2 Boil-Off

Using hydrogen boil-off vapor to cool the structure of a flight vehicle cryogenic upper stage can reduce heat loads to the stage and increase the usable propellant in the stage or extend the life of the stage. The hydrogen vapor can be used to absorb incoming heat as it increases in temperature before being vented overboard. In theory, the amount of heat leaking into the hydrogen tank from the structure will be reduced if the structure is cooled using the propellant boil-off vapor. However, the amount of boil-off vapor available to be used for cooling and the reduction in heat leak to the propellant tank are dependent to each other. The amount of heat leak reduction to the LH2 tank also depends on the total heat load on the stage and the vapor cooling configurations.

heat transfer↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Divertor Plasma Detachment Control Neural Network

DivControlNN is a state-of-the-art software tool that leverages advanced machine learning techniques to predict and control divertor plasma behavior in fusion reactors. Plasma, a highly energetic and electrically charged gas, requires meticulous management to protect reactor components and maintain optimal energy production. Conventional simulation methods, although extremely detailed, typically demand extensive computational time-making them unsuitable for real-time control scenarios. DivControlNN addresses this challenge by learning from tens of thousands of high-fidelity simulations, thereby creating a rapid surrogate model that can deliver near-instantaneous predictions. At the core of its functionality is a sophisticated technique known as latent space mapping, which condenses complex, high-dimensional plasma data into a compact, lower-dimensional representation. This streamlined representation enables the system to quickly forecast essential plasma properties and determine the precise conditions required for effective detachment. Detachment is a crucial process in which the plasma is cooled before reaching the divertor plates, thereby reducing heat loads and mitigating material erosion. In recent experiments conducted on the KSTAR tokamak in South Korea, DivControlNN successfully guided the detachment process without any fine-tuning-even when applied to a new tungsten divertor configuration. By achieving a computational speed-up of over one hundred million times compared to traditional simulation methods while maintaining low prediction errors, DivControlNN stands to significantly enhance real-time control and diagnostic capabilities in future fusion reactors. This breakthrough paves the way for safer, more reliable reactor operation and represents a major advancement toward realizing fusion energy as a practical, sustainable, and clean power source.

Xu, Xueqiao [Lawrence Livermore National Laborator↗

Testing Capabilities for Superconducting Magnets at Fermilab

This presentation will focus on the current testing capabilities for superconducting magnets at Fermilab, highlighting existing systems, recent upgrades, and future plans. The Vertical Magnet Test Facility (VMTF) remains a cornerstone for testing superconducting magnets in R&D applications, maintaining its established capabilities. Stand 4 continues to support the Hi-Lumi AUP production line of magnets in cryostats and has achieved significant improvements through a redesign of lead connections, resolving issues with liquid helium levels and resistance, culminating in a successful endurance test without interruption. Similarly, Stand 7 underwent commissioning and a lead redesign to reduce heat load, while its core testing capabilities remain unchanged. Looking forward, Stand 3 is undergoing a redesign, with plans to restart and begin commissioning by the end of 2025, introducing new features such as background magnetic field testing and upgraded power supplies. Fermilab is also advancing the High Field Vertical Magnet Test Facility (HFVMTF), designed to support the fusion and magnet R&D program, with commissioning scheduled for 2025 and critical components, including the cryostat and power supplies, being delivered. Enhancing all operations, the newly commissioned IB1 cryoplant now offers automated overnight helium production and efficient transfer to a 10,000-liter dewar, streamlining support across all test stands. This talk will provide a comprehensive overview of testing capabilities, and showcasing how Fermilab is advancing its capabilities to meet the evolving demands of superconducting magnet testing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a convective cooling system for a Mach 6 hypersonic transport airframe.

The design of a convective cooling system for an aluminum alloy airframe was established to verify preliminary weight estimates and to define future development requirements. A water glycol coolant was circulated through a closed loop network of supply and return lines to absorb incident aerodynamic heating from structural skin panels with integral passages and to transfer this heat input to a heat exchanger where it is rejected to the hydrogen fuel. Partial shielding of the aluminum alloy structure reduced heat loads to levels compatible with engine fuel flow requirements.

Anthony, F. M.↗

Telescope With Reflecting Baffle

Telescope baffle made from combination of reflecting surfaces. In contrast with previous ellipsoidal reflecting baffles, new baffle reflects skew rays more effectively and easier to construct. For infrared telescopes, reflecting baffles better than absorbing baffles because heat load reduced, and not necessary to contend with insufficiency of infrared absorption exhibited by black coatings.

Linlor, W. I.↗

FET's Perform Well At Cryogenic Temperatures

New metal-oxide-semiconductor field-effect transistors designed for source-follower preamplifiers operating at liquid-helium temperatures in conjunction with infrared detectors. Lower thresholds and offset give CryoFET's greater dynamic range and linearity than conventional MOSFET's at low temperatures and facilitates pair balancing to reduce offsets in output. Reduces heat loading of cryogenic system, extending life, reliability, and performance of cryogenic infrared instruments.

Sclar, N.↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Electromagnetic braking for Mars spacecraft

Aerobraking concepts are being studied to improve performance and cost effectiveness of propulsion systems for Mars landers and Mars interplanetary spacecraft. Access to megawatt power levels (nuclear power coupled to high-storage inductive or capacitive devices) on a manned Mars interplanetary spacecraft may make feasible electromagnetic braking and lift modulation techniques which were previously impractical. Using pulsed microwave and magnetic field technology, potential plasmadynamic braking and hydromagnetic lift modulation techniques have been identified. Entry corridor modulation to reduce loads and heating, to reduce vertical descent rates, and to expand horizontal and lateral landing ranges are possible benefits. In-depth studies are needed to identify specific design concepts for feasibility assessments. Standing wave/plasma sheath interaction techniques appear to be promising. The techniques may require some tailoring of spacecraft external structures and materials. In addition, rapid response guidance and control systems may require the use of structurally embedded sensors coupled to expert systems or to artificial intelligence systems.

Holt, A. C.↗

Demonstration of Multilayer Insulation, Vapor Cooling of Structure, and Mass Gauging for Large Scale Upper Stages: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) Final Report

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The hardware consists of a 4 meter diameter stainless steel tank, structural skirts supporting the tank in the aft direction, and an aluminum forward skirt with vapor cooling channels bolted to it. The initial testing of the SHIIVER hardware was with liquid hydrogen and liquid nitrogen (as a substitute fluid for liquid oxygen and liquid methane) and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full with no MLI on the domes. It reduced the heat load to the tank by approximately 10%, but the boil-off was essentially unchanged at 50% full whether or not vapor cooling was operational with MLI on the domes. The MLI reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment and profile envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed as a result of acoustic testing. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads.

SHIIVER↗

Studies of shock/shock interaction on smooth and transpiration-cooled hemispherical nosetips in hypersonic flow

Experimental studies are conducted to examine the utilization of transpiration cooling to reduce the peak-heating loads in areas of shock/shock interaction. Smooth and transpiration-cooled nosetip models, 12 inches in diameter, were employed in these studies, which focused on defining the pressure distributions and heat transfer in type III and IV interaction areas. Transpiration cooling was determined to significantly increase the size of the shock layer and to move the peak-heating point around the body. A transpiration-cooling rate of more than 30 percent of the freestream maximum flux did not lower the peak-heating level more than 10 percent, but the integrated heating loads were reduced.

Holden, M. S.↗

Tank Applied Testing of Load-Bearing Multilayer Insulation (LB-MLI)

The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing, both thermal and structural was performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.

Thermal Insulation↗

Tank Applied Testing of Load-Bearing Multilayer Insulation (LB-MLI)

The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing both thermally and structurally were performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.

Space Environment Simulation↗