Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reference Correlations for the Density and Viscosity of Molten Alkali and Alkaline Earth Fluoride Salts

While there is a significant body of literature pertaining to thermophysical property measurements of molten salts, there is often a wide degree of variability among independent measurements of the same compounds. As such, the scientific community benefits greatly from an unbiased, independent assessment of duplicate datasets, so that reference correlations which describe these thermophysical properties as functions of temperature can be determined and then commonly used by researchers, scientists, and engineers. With regard to molten fluoride compounds, a significant time has elapsed since density and viscosity reference correlations have been determined; Janz conducted the most recent effort, in 1988, to provide reference correlations for the densities and viscosities of molten fluoride compounds via the National Standard Reference Data System coordinated by the National Bureau of Standards. Since then, new data have been published for molten fluoride compounds, and a new precedent has surfaced for putting forth reference correlations that involve fitting to multiple primary datasets. In this work, reference correlations are put forth for molten alkali and alkaline earth fluoride compounds in an effort to provide updated, improved correlations for general use. For molten alkali fluoride densities, estimated uncertainties with a 95% confidence interval are summarized as follows: LiF (0.63%), NaF (0.48%), KF (0.76%), RbF (0.93%), and CsF (0.75%). For molten alkaline earth fluoride densities, an estimated uncertainty was not able to be quantified for BeF 2 because of limited data; however, estimated uncertainties with a 95% confidence interval are summarized as follows for the remaining alkaline earth fluorides: MgF 2 (1.5%), CaF 2 (0.92%), SrF 2 (1.6%), and BaF 2 (0.23%). For molten alkali fluoride viscosities, uncertainty was not able to be quantified for RbF and CsF because of limited data; however, estimated uncertainties with a 95% confidence interval are summarized as follows for the remaining alkali fluorides: LiF (4.4%), NaF (3.0%), and KF (4.0%). For molten alkaline earth fluoride viscosities, limited consistent data resulted in the recommendation of single datasets (from literature) that are deemed to be the most trustworthy based on the quality of the underlying experimental studies.

Birri, A. [Oak Ridge National Laboratory (ORNL), O↗

A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t sub 1 vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appropriate. This diagnostic, T sub 1, is defined for use with self consistent field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T sub 1 is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of nondynamical electron correlation and is far superior to C sub 0 from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T sub 1 (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t(sub 1) vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appopriate. This diagnostic, T(sub 1) is defined for use with self-consistent-field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T(sub 1) is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of non-dynamical electron correlation and is far superior to C(sub 0) from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T(sub 1) (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

The form of spin orbitals for open-shell restricted Hartree-Fock reference functions

A new set of spin orbitals is proposed for single-reference correlation procedures based on an open-shell restricted Hartree-Fock (RHF) reference function. The spatial parts of the new spin orbitals are from an open-shell RHF calculation. These spin orbitals form a complete, orthonormal set. The RHF single determinant based on these spin orbitals is an S sub 2 eigenfunction, but a linear combination of S sub z eigenfunctions. The advantage of these spin orbitals is that equations for perturbation theory or coupled-cluster theory are symmetric in the spin indices and hence the number of independent parameters to be determined is dramatically reduced.

Jayatilaka, Dylan↗

Baseband signal combiner for large aperture antenna array

The invention provides a means whereby the baseband output signals of all but one of the receivers associated with each of the antennas are summed and used as a correlation reference for the baseband signal not contained in the summed signal, thereby providing a plurality of correlation or alignment loops, each having an output signal related to the phase difference between its input baseband signal and the summed signal. The invention further provides a means for subtracting an output or error signal generated in one of the correlation loops whose baseband signal has a predetermined phase delay from all the other alignment loops, thereby avoiding interaction and reflection effects in the signal combiner. A variable phase delay means for each of the other baseband signals is controlled by its corresponding correlation loop.

Easterling, M. E.↗

Organismic materials for beyond von Neumann machines

The elementary basis of intelligence in organisms with a central nervous system includes neurons and synapses and their complex interconnections forming neural circuits. In non-neural organisms such as slime mold with gel-like media, viscosity modulation enables adaptation to changing environments. At a larger scale, collective intelligence emerges via social interactions and feedback in animal colonies. Learning and memory are therefore multi-scale features that evolve as a result of constant interactions with the environment. There is growing interest in emulating such features of intelligence in computing machines and autonomous systems. Materials that can respond to their environment in a manner similar to organisms (referred to as "organismic materials") therefore may be of interest as hardware components in artificial intelligence machines. In this brief review, we present a class of semiconductors called correlated oxides as candidates for learning machines. The term "correlated" refers to the fact that electrons in such lattices strongly interact and the ground state is not what is predicted by classical band theory. Such materials can undergo insulator-metal transitions at near ambient conditions under external stimuli such as thermal or electrical fields, strain, and chemical doping. Depending on the mechanism driving the transition, intermediate states can be metastable with different volatilities, and the time scales of phase change can be controlled over many orders of magnitude. The change in electronic properties can be sharp or gradual, leading to digital or analog behavior. These properties enable the realization of artificial neurons and synapses and emulate the associative and non-associative learning characteristics found in various organisms. We examine microscopic properties concerning electronic and structural transitions leading to collective behavior and theoretical treatments of the ground state and dynamical response, showcasing VO 2 as a model system. Next, we briefly review algorithms designed from the plasticity demonstrated by phase changing systems. Finally, we conclude the brief review with suggestions for future research toward realizing non-von Neumann machines.

42 ENGINEERING↗

Two-dimensional high temperature optical strain measurement system, phase 2

A laser speckle strain measurement system with two-dimensional measurement capabilities has been built and tested for high temperature applications. The 1st and 2nd principle strains at a point on a specimen are calculated from three components of one-dimensional strain. Strain components are detected by cross-correlating reference and shifted speckle patterns recorded before and after straining the specimen. Speckle patterns are recorded by a linear photodiode array camera. Accurate strains have been measured at temperatures up to 650 C. Stable speckle correlations and linear stress-strain relations have been demonstrated up to 750 C. The resolution of the system is 15 microstrains, with a gauge length less than 1 mm.

Lant, Christian T.↗

Measurements of the thermal conductivity of reference liquids using a modified transient hot-wire needle probe

Many power generation processes feature some type of working fluid that plays a critical role in the transfer of heat throughout the system. To optimize thermal efficiencies, an accurate characterization of the temperature-dependent thermal conductivity of the fluid is needed. Herein, this study develops a time-domain Modified Transient Hot-wire Needle Probe to overcome phenomena that have impaired traditional measurement techniques when the fluid is both corrosive and at an elevated temperature. First, the physical design of the instrument is presented to demonstrate features that limit interference from corrosion, electrical conduction, and convective and radiative heat transfer. Next, a governing equation for 1D (radial) heat conduction is fully developed using the thermal quadrupoles technique. A finite-element study is performed for validation. A sensitivity analysis is done to assess the time-dependent influence of critical parameters in the governing equation for several samples. Finally, thermal conductivity measurements are presented for seven different liquid substances by fitting the thermal model to experimental data across a range of temperatures. Reference correlations are included for comparison. The sample thermal conductivity and ambient temperature of the experimental conditions range from 0.125–16.5$\frac{W}{m·K}$ and 10–400°C, respectively. The total uncertainty, comprised of both the experimental design and fitting process, of all measurements is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic derivation of many-body theories based on general Fermi vacua

This paper describes Wick&D, an implementation of the algebra of second-quantized operators normal ordered with respect to general correlated references and the corresponding Wick theorem [D. Mukherjee, Chem. Phys. Lett. 274, 561 (1997) and W. Kutzelnigg and D. Mukherjee, J. Chem. Phys. 107, 432 (1997)]. Wick&D employs a compact representation of operators and a backtracking algorithm to efficiently evaluate Wick contractions. Since Wick&D can handle both fully and partially contracted terms, it can be applied to both projective and Fock-space many-body formalisms. To demonstrate the usefulness of Wick&D, here we use it to evaluate the single-reference coupled cluster equations up to octuple excitations and report an automated derivation and implementation of the second-order driven similarity renormalization group multireference perturbation theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost Heliostat for High-Flux Small-Area Receivers (Final Technical Report)

This project analyzed a two-stage heliostat concept consisting of a tracking stage and a concentrating stage. The tracking stage uses mirrors mounted on a common drive that move to track the sun. The concentrating stage consists of stationary mirrors that each have a unique angle to direct rays towards a small-area, high-flux, point-focused receiver. By splitting the collection and concentrating process into two stages, multiple small, inexpensive mirrors can share a structure and be controlled by a single drive in the tracking stage. The project effort developed modeling techniques that were specifically relevant to this two-stage heliostat concept. Both field-level and unit-level models were developed. The field-level model does not explicitly consider unit-level losses which are predicted by the unit-level model and then integrated into the field-level model through a correlation referred to as an efficiency modifier. This approach is referred to as the two-model approach; the development and demonstration of this two-model approach for a multi-stage heliostat technology is a key outcome of this work. The field-level model is used to design a field that hits a specific design day power given a set of heliostat design parameters. An oversized field is simulated and then heliostat units are removed based on their annual energy production in order to generate the highest performing field. The field reduction procedure fits a smooth curve fit to annual energy production as a function of position in the field which has the effect of reducing the noise that is otherwise caused by the Monte Carlo ray tracing technique. This approach is referred to as the annual energy fit method and substantially reduces computational run time for a given field level modeling accuracy. The annual energy fit approach enables the selection of a properly sized, high-performing field using orders of magnitude fewer rays than would otherwise be possible and the development of this approach is a second key outcome of this work. These models are used within a genetic optimization algorithm in order to optimize the geometric parameters associated with a heliostat in order to achieve the lowest cost per unit of collected design day power. The cost modeling that underlies the optimization is a simple, scaling type analysis backed up by a much more detailed Design for Manufacture and Assembly (DFMA) analysis. Although the figure of merit used for optimization was not cost per mirror area, this metric is reasonable to use as a means of comparison. The optimally designed 500 kW design has a tracking mirror specific cost of $181.85/m 2 , which is significantly larger than the target value and also larger than the current state of the art. The cost of the torque-tube type linkages contributed substantially to the overall cost. Based on this observation, potentially attractive alternative design configuration utilizing a capstan type actuation system should be investigated. Finally, NREL compared the performance of the two-stage heliostat to the performance of a focused and different sized flat conventional heliostats and showed that, as expected, additional losses versus the convention heliostat caused by a worse cosine efficiency, two stages of reflection, and interstage interactions. The two-stage heliostat requires around 75% more reflective area than a flat 1x1 meter conventional heliostat (similar to a focused heliostat) and 40% more than a flat 2x2 meter conventional heliostat.

14 SOLAR ENERGY↗

CCD architecture for spacecraft SAR image processing

A real-time synthetic aperture radar (SAR) image processing architecture amenable to future on-board spacecraft applications is currently under development. Using state-of-the-art charge-coupled device (CCD) technology, low cost and power are inherent features. Other characteristics include the ability to reprogram correlation reference functions, correct for range migration, and compensate for antenna beam pointing errors on the spacecraft in real time. The first spaceborne demonstration is scheduled to be flown as an experiment on a 1982 Shuttle imaging radar mission (SIR-B). This paper describes the architecture and implementation characteristics of this initial spaceborne CCD SAR image processor.

Arens, W. E.↗

HEAO attitude reference design

The paper deals with the precision onboard attitude reference implemented as part of the attitude control and determination subsystem for the three High Energy Astronomy Observatories (HEAO-A, HEAO-B, and HEAO-C) in the HEAO scientific spacecraft program. The first observatory (HEAO-A, designated HEAO-1 when in orbit) was launched successfully into near-earth orbit on August 12, 1977. The HEAO attitude reference, analysis techniques for performance prediction, and flight results from the HEAO-1 observatory during its first months of operation. The HEAO-B design is specifically described and analyzed in terms of gyro processing, kinematic integration, ground update algorithm, and star tracker update algorithm. Attitude reference performance estimates are also discussed. It is shown that the orbital performance of the attitude reference correlates very well with the developmental predictions, thereby validating the analytical techniques used during the development. This validation provides a firm basis from which to extrapolate to other applications and related design concepts.

Hoffman, D. P.↗

Structure Identification Within a Transitioning Swept-Wing Boundary Layer

Extensive measurements are made in a transitioning swept-wing boundary layer using hot-film, hot-wire and cross-wire anemometry. The crossflow-dominated flow contains stationary vortices that breakdown near mid-chord. The most amplified vortex wavelength is forced by the use of artificial roughness elements near the leading edge. Two-component velocity and spanwise surface shear-stress correlation measurements are made at two constant chord locations, before and after transition. Streamwise surface shear stresses are also measured through the entire transition region. Correlation techniques are used to identify stationary structures in the laminar regime and coherent structures in the turbulent regime. Basic techniques include observation of the spatial correlations and the spatially distributed auto-spectra. The primary and secondary instability mechanisms are identified in the spectra in all measured fields. The primary mechanism is seen to grow, cause transition and produce large-scale turbulence. The secondary mechanism grows through the entire transition region and produces the small-scale turbulence. Advanced techniques use Linear Stochastic Estimation (LSE) and Proper Orthogonal Decomposition (POD) to identify the spatio-temporal evolutions of structures in the boundary layer. LSE is used to estimate the instantaneous velocity fields using temporal data from just two spatial locations and the spatial correlations. Reference locations are selected using maximum RMS values to provide the best available estimates. POD is used to objectively determine modes characteristic of the measured flow based on energy. The stationary vortices are identified in the first laminar modes of each velocity component and shear component. Experimental evidence suggests that neighboring vortices interact and produce large coherent structures with spanwise periodicity at double the stationary vortex wavelength. An objective transition region detection method is developed using streamwise spatial POD solutions which isolate the growth of the primary and secondary instability mechanisms in the first and second modes, respectively. Temporal evolutions of dominant POD modes in all measured fields are calculated. These scalar POD coefficients contain the integrated characteristics of the entire field, greatly reducing the amount of data to characterize the instantaneous field. These modes may then be used to train future flow control algorithms based on neural networks.

Chapman, Keith↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brain signaling and behavioral responses induced by exposure to (56)Fe-particle radiation

Previous experiments have demonstrated that exposure to 56Fe-particle irradiation (1.5 Gy, 1 GeV) produced aging-like accelerations in neuronal and behavioral deficits. Astronauts on long-term space flights will be exposed to similar heavy-particle radiations that might have similar deleterious effects on neuronal signaling and cognitive behavior. Therefore, the present study evaluated whether radiation-induced spatial learning and memory behavioral deficits are associated with region-specific brain signaling deficits by measuring signaling molecules previously found to be essential for behavior [pre-synaptic vesicle proteins, synaptobrevin and synaptophysin, and protein kinases, calcium-dependent PRKCs (also known as PKCs) and PRKA (PRKA RIIbeta)]. The results demonstrated a significant radiation-induced increase in reference memory errors. The increases in reference memory errors were significantly negatively correlated with striatal synaptobrevin and frontal cortical synaptophysin expression. Both synaptophysin and synaptobrevin are synaptic vesicle proteins that are important in cognition. Striatal PRKA, a memory signaling molecule, was also significantly negatively correlated with reference memory errors. Overall, our findings suggest that radiation-induced pre-synaptic facilitation may contribute to some previously reported radiation-induced decrease in striatal dopamine release and for the disruption of the central dopaminergic system integrity and dopamine-mediated behavior.

NASA Discipline Radiation Health↗