Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCREENING TECHNIQUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improving Solar and Solar+Storage Screening Techniques to Reduce Utility Interconnection Time and Costs (Final Technical Report)

Residential PV installations have increased rapidly over the last decade, and the increased application volume has caused permitting delays and lower overall adoption rates. In this project, we developed and evaluated whether data-driven secondary modeling and screening techniques can help utilities assess customer applications more accurately than traditional screening shortcuts. Secondary topologies are predicted using decision trees and commonly available information, such as service transformer, customer, and street locations. Conductors were predicted using a logistic regression method based on real world object (RWO) types, service transformer ratings, conductor length, and distance to transformer. After developing the combined primary and secondary distribution network model, hosting capacity results were used to train a random forest model to predict the pass/fail likelihood of a customer application. Powerflow based models with predicted secondaries and data-driven methods both increased the screening success rate, relative to common utility heuristics, by as much as 55 percentage points. Data-driven screening techniques were described by one utility as a "right-sized" approach for residential customers given the low-risk of small errors and the high-cost of accurate modeling.

14 SOLAR ENERGY↗

Vapor-screen technique applied to a delta-wing aircraft

Recently, the vapor-screen technique has been applied to a delta-wing aircraft (F-106B) during both subsonic 1-g and transonic high-g flights. Selected subsonic vapor-screen images are presented which show the benefits of digital enhancement. Among the major findings are that multiple, corotating vortices exist up to 20-deg angle of attack, and the measured flight core location is not well predicted by theory. Planned extensions for this work are also discussed.

Lamar, John E.↗

Testing and failure analysis to improve screening techniques for hermetically sealed metallized film capacitors for low energy applications

Effective screening techniques are evaluated for detecting insulation resistance degradation and failure in hermetically sealed metallized film capacitors used in applications where low capacitor voltage and energy levels are common to the circuitry. A special test and monitoring system capable of rapidly scanning all test capacitors and recording faults and/or failures is examined. Tests include temperature cycling and storage as well as low, medium, and high voltage life tests. Polysulfone film capacitors are more heat stable and reliable than polycarbonate film units.

Source record↗

Vapor-screen technique for flow visualization in the Langley Unitary Plan Wind Tunnel

The vapor-screen technique for flow visualization, as developed for the Langley Unitary Plan Wind Tunnel, is described with evaluations of light sources and photographic equipment. Test parameters including dew point, pressure, and temperature were varied to determine optimum conditions for obtaining high-quality vapor-screen photographs. The investigation was conducted in the supersonic speed range for Mach numbers from 1.47 to 4.63 at model angles of attack up to 35 deg. Vapor-screen photographs illustrating various flow patterns are presented for several missile and aircraft configurations. Examples of vapor-screen results that have contributed to the understanding of complex flow fields and provided a basis for the development of theoretical codes are presented with reference to other research.

Morris, O. A.↗

Thermoluminescence of Antarctic meteorites: A rapid screening technique for terrestrial age estimation, pairing studies and identification of specimens with unusual prefall histories

Thermoluminescence (TL) is a promising technique for rapid screening of the large numbers of Antarctic meteorites, permitting identification of interesting specimens that can then be studied in detail by other, more definite techniques. Specifically, TL permits determination of rough terrestrial age, identification of potential paired groups and location of specimens with unusual pre-fall histories. Meteorites with long terrestrial ages are particularly valuable for studying transport and weathering mechanisms. Pairing studies are possible because TL variations among meteorites are large compared to variations within individual objects, especially for natural TL. Available TL data for several L3 fragments, three of which were paired by other techniques, are presented as an example of the use of TL parameters in pairing studies. Additional TL measurements, specifically a blind test, are recommended to satisfactorily establish the reliability of this pairing property. The TL measurements also identify fragments with unusual pre-fall histories, such an near-Sun orbits.

Sutton, S. R.↗

In-flight flow visualization of F-106B leading-edge vortex using the vapor-screen technique

A flight program was conducted with the objective to study the vortex flow systems existing around the F-106B aircraft. Level 1-G decelerating flight with varying angle of attack was considered along with conditions involving G levels in the range from 4.5 to 5.5 and angles of attack in the range from 16 to 19 degrees. It was demonstrated that the vapor screen technique can be applied successfully to flight vehicles under a variety of test conditions, taking into consideration the transonic maneuver performed by fighter aircraft. Details regarding the employed in-flight flow visualization technique are discussed, taking into account the seeding system, the light sheet system, the video system, the control system, and the recording of the data. Attention is also given to the flight program, the data development, and the scientific observations.

Lamar, J. E.↗

Screening technique makes reliable bond at room temperature

Stainless-steel screen used to lay room temperature curing epoxy adhesive permits reliable bonding of electronic circuits boards. This technique would be useful with thin-walled structures that warp during conventional bonding operations.

Source record↗

A Device-Independent Screening Technique for Rapidly Identifying Next Generation OPV Materials

In this paper, we introduce a methodology that enables rapid down selection of promising new OPV polymers, based on a device-independent screening metric that takes into account intrinsic charge generation and transport, as well as charge carrier lifetimes. As a demonstration of our method, we present a case study using a set of well-known high performance polymers based on the benzodithiophene (BDT) moiety: PTB7, PTB7-Th, PBDTTT-CT, and PBDTTPD. Compared to current device-optimization based methods, we are able to identify the champion material in less time, taking only hours rather than months and may even be able to identify promising candidate materials that have been abandoned for device optimization.

14 SOLAR ENERGY↗

Improved high-throughput screening technique to rapidly isolate Chlamydomonas transformants expressing recombinant proteins

Abstract The single-celled eukaryotic green alga Chlamydomonas reinhardtii has long been a model system for developing genetic tools for algae, and is also considered a potential platform for the production of high-value recombinant proteins. Identifying transformants with high levels of recombinant protein expression has been a challenge in this organism, as random integration of transgenes into the nuclear genome leads to low frequency of cell lines with high gene expression. Here, we describe the design of an optimized vector for the expression of recombinant proteins in Chlamydomonas , that when transformed and screened using a dual antibiotic selection, followed by screening using fluorescence activated cell sorting (FACS), permits rapid identification and isolation of microalgal transformants with high expression of a recombinant protein. This process greatly reduces the time required for the screening process, and can produce large populations of recombinant algae transformants with between 60 and 100% of cells producing the recombinant protein of interest, in as little as 3 weeks, that can then be used for whole population sequencing or individual clone analysis. Utilizing this new vector and high-throughput screening (HTS) process resulted in an order of magnitude improvement over existing methods, which normally produced under 1% of algae transformants expressing the protein of interest. This process can be applied to other algal strains and recombinant proteins to enhance screening efficiency, thereby speeding up the discovery and development of algal-derived recombinant protein products. Key points • A protein expression vector using double-antibiotic resistance genes was designed • Double antibiotic selection causes fewer colonies with more positive for phenotype • Coupling the new vector with FACS improves microalgal screening efficiency > 60%

59 BASIC BIOLOGICAL SCIENCES↗

Circularly Polarized Light-Induced Microwave Conductivity Measurement: Rapid Screening Technique of Electronic Conductivity in Chiral Molecular Materials

Here, we developed circularly polarized light-time-resolved microwave conductivity (CPL-TRMC) for investigation of the CPL-dependent photoinduced charge carrier dynamics in chiral materials with chiroptical properties. Chiral R- or S-perylenediimide (PDI) molecular thin films were paired with handedness-sorted (6,5) and (11,-5) single-walled carbon nanotube (SWCNT) films to compose a donor (D)-acceptor (A) system for the spin-dependent charge separation process, and the D-A system was examined through linear and circular polarization-dependent steady-state and time-resolved measurements. The R-PDI-(6,5) film exhibited strong enhancement in circular dichroism (CD) and revealed a reversed transient conductivity signal, relative to the polarity of CD in CPL-TRMC measurement upon excitation of the E 11 state, which is interpreted as arising from a spin-dependent initial charge separation process. Through linear polarization-dependent flash photolysis TRMC and circular polarization-resolved femtosecond transient absorption, we could deduce that sub-picosecond intertubular charge separation upon E 11 excitation in SWCNT was responsible for the spin-dependent photoconductivity transients observed in CPL-TRMC measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of screening techniques for ceramic capacitors

The techniques involved are ultrasonic scanning, neutron radiography, scanning laser acoustic microscopy, and voltage conditioning. The test capacitor, for this first phase, is a 0.47 uF, 50V capacitor style CKR06. Eighteen of 768 devices failed in voltage conditioning with elapsed times from 15 minutes to 1239 hours. Eleven of the failures were detected by ultrasonic scanning. Four failures were found by neutron radiography. Fourteen failures showed up in the acoustic microscopy test. Three failures in voltage conditioning were not detected by any of the techniques. Failures were confirmed by destructive physical analysis. There is no direct relationship between the size of the defect and electrical failure.

Kiernan, G. F.↗