Search NASASearch

SEARCH · Search NASA

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.

NASA Discipline Musculoskeletal

TLSLEAF: Automatic Leaf Angle Estimates From Single-Scan Terrestrial Laser Scanning

Leaf angle distribution (LAD) in forest canopies affects estimates of leaf area, light interception, and global-scale photosynthesis, but is often simplified to a single theoretical value. Here, we present TLSLeAF (Terrestrial Laser Scanning Leaf Angle Function), an automated open-source method of deriving LADs from terrestrial laser scanning. TLSLeAF produces canopy-scale leaf angle and LADs by relying on gridded laser scanning data. The approach increases processing speed, improves angle estimates, and requires minimal user input. Key features are automation, leaf–wood classification, beta parameter output, and implementation in R to increase accessibility for the ecology community. TLSLeAF precisely estimates leaf angle with minimal distance effects on angular estimates while rapidly producing LADs on a consumer-grade machine. We challenge the popular spherical LAD assumption, showing sensitivity to ecosystem type in plant area index and foliage profile estimates that translate to c. 25% and c. 11% increases in canopy net photosynthesis (c. 25%) and solar-induced chlorophyll fluorescence (c. 11%). TLSLeAF can now be applied to the vast catalog of laser scanning data already available from ecosystems around the globe. The ease of use will enable widespread adoption of the method outside of remote-sensing experts, allowing greater accessibility for addressing ecological hypotheses and large-scale ecosystem modeling efforts.

3D

PSIDD (2): A Prototype Post-Scan Interactive Data Display System for Detailed Analysis of Ultrasonic Scans

This article presents the description of PSIDD(2), a post-scan interactive data display system for ultrasonic contact scan and single measurement analysis. PSIDD(2) was developed in conjunction with ASTM standards for ultrasonic velocity and attenuation coefficient contact measurements. This system has been upgraded from its original version PSIDD(1) and improvements are described in this article. PSIDD(2) implements a comparison mode where the display of time domain waveforms and ultrasonic properties versus frequency can be shown for up to five scan points on one plot. This allows the rapid contrasting of sample areas exhibiting different ultrasonic properties as initially indicated by the ultrasonic contact scan image. This improvement plus additional features to be described in the article greatly facilitate material microstructural appraisal.

Cao, Wei

Self port scanning tool : providing a more secure computing Environment through the use of proactive port scanning

Secure computing is a necessity in the hostile environment that the internet has become. Protection from nefarious individuals and organizations requires a solution that is more a methodology than a one time fix. One aspect of this methodology is having the knowledge of which network ports a computer has open to the world, These network ports are essentially the doorways from the internet into the computer. An assessment method which uses the nmap software to scan ports has been developed to aid System Administrators (SAs) with analysis of open ports on their system(s). Additionally, baselines for several operating systems have been developed so that SAs can compare their open ports to a baseline for a given operating system. Further, the tool is deployed on a website where SAs and Users can request a port scan of their computer. The results are then emailed to the requestor. This tool aids Users, SAs, and security professionals by providing an overall picture of what services are running, what ports are open, potential trojan programs or backdoors, and what ports can be closed.

nMap

System converts slow-scan to standard fast-scan TV signals

Signal conversion system converts slow-scan video signals into standard fast-scan television signals that are required for reproduction of television pictures on American TV sets. This system permits conversion of TV pictures produced in accordance with the standards of one country into the standards of another country.

Lipoma, P. C.

PSIDD: A Post-Scan Interactive Data Display System for Ultrasonic Scans

An ultrasonic data display system was developed at NASA Lewis Research Center that allows the user to interactively examine digitized waveforms and processed information associated with any specific scan location of an ultrasonic contact scan. This information is displayed on a video display monitor and includes acquired time-domain waveforms, frequency-domain magnitude and phase spectra, and ultrasonic properties (pulse velocity, phase velocity, reflection coefficient, attenuation coefficient, attenuation coefficient error) as a function of frequency for a material. This report describes the system features and illustrates the system's usefulness for nondestructive materials characterization.

Roth, Don J.

Multifrequency Ultra-High Resolution Miniature Scanning Microscope Using Microchannel And Solid-State Sensor Technologies And Method For Scanning Samples

A miniature, ultra-high resolution, and color scanning microscope using microchannel and solid-state technology that does not require focus adjustment. One embodiment includes a source of collimated radiant energy for illuminating a sample, a plurality of narrow angle filters comprising a microchannel structure to permit the passage of only unscattered radiant energy through the microchannels with some portion of the radiant energy entering the microchannels from the sample, a solid-state sensor array attached to the microchannel structure, the microchannels being aligned with an element of the solid-state sensor array, that portion of the radiant energy entering the microchannels parallel to the microchannel walls travels to the sensor element generating an electrical signal from which an image is reconstructed by an external device, and a moving element for movement of the microchannel structure relative to the sample. Discloses a method for scanning samples whereby the sensor array elements trace parallel paths that are arbitrarily close to the parallel paths traced by other elements of the array.

Wang, Yu

Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

Whalen, Robert T.

The New Weather Radar for America's Space Program in Florida: A Temperature Profile Adaptive Scan Strategy

A new weather radar is being acquired for use in support of America s space program at Cape Canaveral Air Force Station, NASA Kennedy Space Center, and Patrick AFB on the east coast of central Florida. This new radar replaces the modified WSR-74C at Patrick AFB that has been in use since 1984. The new radar is a Radtec TDR 43-250, which has Doppler and dual polarization capability. A new fixed scan strategy was designed to best support the space program. The fixed scan strategy represents a complex compromise between many competing factors and relies on climatological heights of various temperatures that are important for improved lightning forecasting and evaluation of Lightning Launch Commit Criteria (LCC), which are the weather rules to avoid lightning strikes to in-flight rockets. The 0 C to -20 C layer is vital since most generation of electric charge occurs within it and so it is critical in evaluating Lightning LCC and in forecasting lightning. These are two of the most important duties of 45 WS. While the fixed scan strategy that covers most of the climatological variation of the 0 C to -20 C levels with high resolution ensures that these critical temperatures are well covered most of the time, it also means that on any particular day the radar is spending precious time scanning at angles covering less important heights. The goal of this project is to develop a user-friendly, Interactive Data Language (IDL) computer program that will automatically generate optimized radar scan strategies that adapt to user input of the temperature profile and other important parameters. By using only the required scan angles output by the temperature profile adaptive scan strategy program, faster update times for volume scans and/or collection of more samples per gate for better data quality is possible, while maintaining high resolution at the critical temperature levels. The temperature profile adaptive technique will also take into account earth curvature and refraction when geo-locating the radar beam (i.e., beam height and arc distance), including non-standard refraction based on the user-input temperature profile. In addition to temperature profile adaptivity, this paper will also summarize the other requirements for this scan strategy program such as detection of low-level boundaries, detection of anvil clouds, reducing the Cone Of Silence, and allowing for times when deep convective clouds will not occur. The adaptive technique will be carefully compared to and benchmarked against the new fixed scan strategy. Specific environmental scenarios in which the adaptive scan strategy is able to optimize and improve coverage and resolution at critical heights, scan time, and/or sample numbers relative to the fixed scan strategy will be presented.

Carey, L. D.

Suspension system for gimbal supported scanning payloads

Gimballed scanning devices or instruments are the subject of this invention. Scanning is an important aspect of space science. To achieve a scan pattern some means must be provided which impart to the payload an oscillatory motion. Various forms of machines have been employed for controllably conferring on scanning instruments predetermined scan patterns. They include control moment gyroscopes, reaction wheels, torque motors, reaction control systems, and the like. But rotating unbalanced mass (RUM) devices are a new and efficient way to generate scans in gimballed payloads. RUM devices are superior to previous scanning apparatus, but they require power consuming and frequently complex auxiliary control systems to position and reposition the particular scan pattern relative to a target or a number of targets. Herein the control system is simplified. The most frequently employed method for achieving the various scan patterns is to gimbal the scanning device. Gimbals are suspended in such a way that they can be activated to generate the scan pattern. The suspension means described is for payloads supported in gimbals wherein the payload rotation is restricted by a flex pivot so that the payload oscillates, thereby moving in a scan pattern.

Polites, Michael E.

Large Aperture Scanning Lidar Based on Holographic Optical Elements

Lidar remote sensing instruments can make a significant contribution to satisfying many of the required measurements of atmospheric and surface parameters for future spaceborne platforms, including topographic altimeters, atmospheric profiles of, wind, humidity, temperature, trace molecules, aerosols, and clouds. It is highly desirable to have wide measurement swaths for rapid coverage rather than just the narrow ribbon of data that is obtained with a nadir only observation. For most applications global coverage is required, and for wind measurements scanning or pointing is required in order to retrieve the full 3-D wind vector from multiple line-of-sight Doppler measurements. Conventional lidar receivers make up a substantial portion of the instrument's size and weight. Wide angle scanning typically requires a large scanning mirror in front of the receiver telescope, or pointing the entire telescope and aft optics assembly, Either of these methods entails the use of large bearings, motors, gearing and their associated electronics. Spaceborne instruments also need reaction wheels to counter the torque applied to the spacecraft by these motions. NASA has developed simplified conical scanning telescopes using Holographic Optical Elements (HOEs) to reduce the size, mass, angular momentum, and cost of scanning lidar systems. NASA has developed two operating lidar systems based on 40 cm diameter HOEs. The first such system, named Prototype Holographic Atmospheric Scanner for Environmental Remote Sensing (PHASERS) was a joint development between NASA Goddard Space Flight Center (GSFC) and the University of Maryland College Park. PHASERS is based on a reflection HOE for use at the doubled Nd:YAG laser wavelength of 532 nm and has recently undergone a number of design changes in a collaborative effort between GSFC and Saint Anselm College in New Hampshire. The next step was to develop IR transmission HOEs for use with the Nd:YAG fundamental in the Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE). The HOE spins like a compact disk in a large ring ball bearing. In an aircraft the HOE faces down, looking out through a window at an angle of 45 degrees off-nadir. The HOE diffracts 85% of the incident 532 nm light into a 160 micron spot at a focal length of 1 meter. HARLIE is a field deployable lidar measuring aerosol, cloud, and boundary layer backscatter for atmospheric research. It has flown several times and is also used from a ground-based trailer in an upward-looking mode. The HOE generates a 45 degree conical scan pattern by rotating at speeds up to 30 rpm. Like PHASERS, the HOE in HARLIE serves both as the laser collimating lens as well as the receiver telescope primary optic. The telescope is coupled to the receiver package via fiber optic. The transmitter is a diode pumped Nd:YAG laser operating at 1064 nm, delivering 1 mJ pulses at a 5 KHz rep-rate. The receiver has a 200 microradian field-of-view and a 0.5 nm optical bandpass. The photon counting data system utilizes a single Geiger-mode silicon avalanche photodiode detector, This new technology has also presented us with new data visualization challenges as well as new measurement techniques. The backscatter data obtained from a stationary (i.e. ground-based) scanning HOE lidar is on the surface of a cone, which when viewed over many consecutive scans can reveal atmospheric motions on this surface over time as the atmosphere advects over the site. In a moving platform such as an airplane or satellite, the data from consecutive scans cover different areas under the flight path, revealing atmospheric structure in 3-dimensions. An example of a visualization of HARLIE ground-based data is presented, showing aerosol backscatter on a 90 degree conical surface generated from one 360 degree scan of the lidar during the HOLO-1 field campaign on the afternoon of 10 March 1999. Higher backscatter levels are rendered as lighter signal against a dark background. Breaking Kelvin-Helmholtz waves are evident on the north side of the scan at an altitude of 10-11 km. Time series of successive scans made at regular intervals render unique views of atmospheric motions, from which vertical profiles of atmospheric wind vectors can be obtained using a unique data analysis approach. Wind vectors obtained from the lidar were compared with co-located radiosonde wind profiles during an intensive operating period in September-October 2000 at the Atmospheric Radiation Measurement Program's Southern Great Plains Central Facility.

Schwemmer, Geary K.

Improving Cross-track Scanning Radiometers’ Precipitation Retrieval over Ocean by Morphing

Previous studies showed that conical scanning radiometers greatly outperform cross-track scanning radiometers for precipitation retrieval over ocean. This study demonstrates a novel approach to improve precipitation rates at the cross-track scanning radiometers’ observation time by propagating the conical scanning radiometers’ retrievals to the cross-track scanning radiometers’ observation time. The improved precipitation rate is a weighted average of original cross-track radiometers’ retrievals and retrievals propagated from a conical scanning radiometer. The cross-track scanning radiometers include the Advanced Technology Microwave Sounder (ATMS) on board the SNPP satellite and four Microwave Humidity Sounders (MHSs). The conical scanning radiometers include the Advanced Microwave Scanning Radiometer 2 (AMSR2) and three Special Sensor Microwave Imager/Sounders (SSMISs), while the precipitation retrievals from the Global Precipitation Measurement (GPM) Microwave Imager (GMI) are taken as the reference. Results show that the morphed precipitation rates agree much better with the reference. The degree of improvement depends on several factors, including the propagated precipitation source, the time interval between the cross-track scanning radiometer and the conical scanning radiometer, the precipitation type (convective versus stratiform), the precipitation events’ size, and the geolocation. The study has potential to greatly improve high-impact weather systems monitoring (e.g., hurricanes) and multisatellite precipitation products. It may also enhance the usefulness of future satellite missions with cross-track scanning radiometers on board.

Yalei You

3D Scanning Laboratory

The 3D Scanning Lab uses a number of technologies to capture 3D surface data. Those technologies are structured light scanning, discrete point measurement photogrammetry and Light Detecting and Ranging(LIDAR). Structured light is a non-contact optical technique used to capture as built surface geometries quickly and accurately. LIDAR is a laser scanning technique used to capture 3D surfaces. And photogrammetry uses a certified DSLR camera to measure discrete registered and non-registered points in 3D space. MSFC’s 3D Scanning Team uses 3D scanning to provide hardware inspections, reverse engineered CAD models, manufacturing/process development and digital assemblies. The inspection process compares the captured data to CAD, providing a color plot detailing the deviations of the scan data to the CAD model. Dimensional measurements and GD&T can also be interrogated. Inspection can provide scan-to-scan data comparisons which is ideal for assessing tested hardware, e.g. comparing data captured before and after hardware testing. Reverse engineering is used to develop CAD models from scan data. This is useful for heritage hardware studies, developing building or structural models and inputs for simulation studies and design efforts. The lab uses the 3D surface scan data to drive manufacturing/machining processes, termed match machining. This technique has been used to modify nozzles, injectors, additive manufactured parts, composite barrel sections, etc. Parts of an assembly can be scanned and assembled in a virtual environment providing an accurate 3D representation of the assembled hardware in its as-scanned state. This can provide detailed information of internal components that would otherwise not be accessible.

Advanced Manufacturing

Results of a laboratory experiment that tests rotating unbalanced-mass devices for scanning gimbaled payloads and free-flying spacecraft

Rotating unbalanced-mass (RUM) devices are a new way to scan space-based, balloon-borne, and ground-based gimbaled payloads, like x-ray and gamma-ray telescopes. They can also be used to scan free-flying spacecraft. Circular scans, linear scans, and raster scans can be generated. A pair of RUM devices generates the basic scan motion and an auxiliary control system using torque motors, control moment gyros, or reaction wheels keeps the scan centered on the target and produces some complementary motion for raster scanning. Previous analyses and simulation results show that this approach offers significant power savings compared to scanning only with the auxiliary control system, especially with large payloads and high scan frequencies. However, these claims have never been proven until now. This paper describes a laboratory experiment which tests the concept of scanning a gimbaled payload with RUM devices. A description of the experiment is given and test results that prove the concept are presented. The test results are compared with those from a computer simulation model of the experiment and the differences are discussed.

Alhorn, D. C.

Rotating Unbalanced-Mass devices for scanning: Results from the proof-of-concept test

Rotating unbalanced-mass (RUM) devices are a new way to scan space-based, balloon-borne, and ground-based gimbaled payloads, like x-ray and gamma-ray telescopes. They can also be used to scan free-flying spacecraft. Circular scans, linear scans, and raster scans can be generated. A pair of RUM devices generates the basic scan motion and an auxiliary control system using torque motors, control moment gyros, or reaction wheels keeps the scan centered on the target and produces some complementary motion for raster scanning. Previous analyses and simulation results show that this approach offers significant power savings compared to scanning only with the auxiliary control system, especially with large payloads and high scan frequencies. However, these claims have never been proven until now. This paper describes a laboratory experiment which tests the concept of scanning a gimbaled payload with RUM devices. The test results are compared with those from a computer simulation model of the experiment and the differences are discussed.

Alhorn, Dean C.