Search NASA⌕ Search

SEARCH · Search NASA

Results for “SDSM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determination of the SNPP VIIRS SDSM Screen Relative Transmittance From Both Yaw Maneuver and Regular On-Orbit Data

The Visible Infrared Imaging Radiometer Suiteaboard the Suomi National Polar-orbiting Partnership (SNPP) satellite performs radiometric calibration of its reflective solar bands primarily through observing a sunlit onboard solar diffuser (SD). The SD bidirectional reflectance distribution function(BRDF) degradation factor is determined by an onboard SD stability monitor (SDSM), which observes the Sun through a pinhole screen and the sunlit SD. The transmittance of the SDSM pinhole screen over a range of solar angles was determined prelaunch and used initially to determine the BRDF degradation factor.The degradation-factor-versus-time curves were found to have a number of very large unphysical undulations likely due to the inaccuracy in the prelaunch determined SDSM screen transmittance.To refine the SDSM screen transmittance, satellite yaw maneuvers were carried out. With the SDSM screen relative transmittance determined from the yaw maneuver data, the computed BRDFdegradation factor curves still have large unphysical ripples, indicating that the projected solar horizontal angular step size in the yaw maneuver data is too large to resolve the transmittance at a fine angular scale. We develop a methodology to use both the yaw maneuver and a small portion of regular on-orbit data to determine the SDSM screen relative transmittance at a fine angular scale. We determine that the error standard deviation of the calculated relative transmittance ranges from 0.00030 (672 nm) to 0.00092 (926 nm). With the newly determined SDSM screen relative transmittance, the computed BRDF degradation factor behaves much more smoothly over time.

Lei, Ning↗

Comparison of the MODIS and VIIRS On-Board SD and SDSM Performance

The MODIS reflective solar bands (RSB) are calibrated on-orbit using a solar diffuser (SD) with its on-orbit degradation, or change in the bi-directional reflectance factor (BRF) monitored using a solar diffuser stability monitor (SDSM). By performing alternate observations of direct sunlight via an attenuation screen and of sunlight reflected diffusely off the SD, the SDSM monitors the on-orbit degradation of the SD. The MODIS SDSM has 9 detectors, covering wavelengths from 0.41 to 0.94 microns. Both Terra and Aqua MODIS instruments have successfully operated for more than 16 years on-orbit, with the SD experiencing significant degradation at the shortest wavelength (about 50 percent for Terra MODIS and about 20 percent for Aqua MODIS at 0.41 microns). The first VIIRS instrument on the Suomi NPP spacecraft was launched in October 2011 and the follow-on instrument was launched in November 2017 on the JPSS-1 spacecraft (now NOAA-20). Both the VIIRS instruments carry a MODIS-like SD and SDSM system with an improved design based on the lessons learned from MODIS. Unlike MODIS, the VIIRS SDSM collects data using 8 detectors covering a similar wavelength range as MODIS. A similar wavelength dependent SD degradation pattern is also observed in both VIIRS instruments. This paper provides a comparison of the on-orbit performance of the four instruments in terms of the on-orbit changes in the SDSM detector responses and on-orbit degradations of their SDs. The NOAA-20 VIIRS instrument is still in its first year of operation and hence the early performance of the Terra and Aqua MODIS and SNPP VIIRS is discussed to provide a perspective comparison.

VIIRS↗

SNPP and N20 VIIRS Solar Vector Orientation Knowledge Error Detected by SDSM Sun Views

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a passive scanning Earth observing satellite radiometer. The VIIRS has 22 spectral bands with design center wavelengths from 0.41 to 12.01 μm, providing data to generate more than 20 Earth’s biogeophysical parameters. Fourteen of the 22 VIIRS bands are the reflective solar bands (RSBs), detecting Earth reflected sunlight. To ensure data quality, regular on-orbit radiometric calibrations of the RSBs are performed, mainly through observations of an onboard solar diffuser (SD). The spectral radiance provided by the sunlit SD depends on the SD screen transmittance which is a function of the solar vector orientation. Additionally, on orbit the SD’s bidirectional reflectance distribution function (BRDF) changes its value due to solar bombardment. The BRDF change is derived from the SD stability monitor (SDSM) measurements. The SDSM views the Sun through a screen with through holes (the SDSM screen) and the SD at almost the same time. The time series of the ratio of the signal strengths is a measure of the SD BRDF on-orbit change. Hence the measurements of the on-orbit SD BRDF change depends on the SDSM screen relative transmittance which is also solar vector orientation dependent. In this paper for both the SNPP and the NOAA-20 VIIRS instruments we examine the solar vector orientation knowledge error through matching the SDSM screen relative effective transmittances derived from the calibration data collected on the yaw maneuver and the regular orbits.

SNPP↗

MODIS Solar Diffuser On-Orbit Degradation Characterization Using Improved SDSM Screen Modeling

The Solar Diffuser (SD) is used for the MODIS reflective solar bands (RSB) calibration. An on-board Solar Diffuser Stability Monitor (SDSM) tracks the degradation of its on-orbit bi-directional reflectance factor (BRF). To best match the SDSM detector signals from its Sun view and SD view, a fixed attenuation screen is placed in its Sun view path, where the responses show ripples up to 10%, much larger than design expectation. Algorithms have been developed since the mission beginning to mitigate the impacts of these ripples. In recent years, a look-up-table (LUT) based approach has been implemented to account for these ripples. The LUT modeling of the elevation and azimuth angles is constructed from the detector 9 (D9) of SDSM observations in the MODIS early mission. The response of other detectors is normalized to D9 to reduce the ripples observed in the sun-view data. The accuracy of all detectors degradation estimation depends on how well the D9 approximated. After multiple years of operation (Terra: 16 years; Aqua: 14 years), degradation behavior of all detectors can be monitored by their own. This paper revisits the LUT modeling and proposes a dynamic scheme to build a LUT independently for each detector. Further refinement in the Sun view screen characterization will be highlighted to ensure the degradation estimation accuracy. Results of both Terra and Aqua SD on-orbit degradation are derived from the improved modeling and curve fitting strategy.

Chen, H.↗

Center of Excellence in Remote Sensing at SDSM&T

The College of Earth Systems at the South Dakota School of Mines and Technology established a Center for Remote Sensing to consolidate and coordinate the educational and research thrusts from different parts of campus into unified center with a focus on applications of remote sensing data in integrated environmental assessments. The threefold mission objectives of the Center are: 1) To educate students and the community in the principles and applications of remote sensing 2) To facilitate use of remote sensing in research coupling earth modeling, monitoring, and GIS 3) To distribute remote sensing data and expertise to regional federal, state, tribal, and local agencies.

Price Maribeth H.↗

Modeling transmittance of MODIS solar diffuser stability monitor sun view screen

Earlier work by Sun et al. [2005] modeled the Sun view screen transmittance of the solar diffuser stability monitor (SDSM) on Moderate Resolution Imaging Spectroradiometer (MODIS) which explains the oscillatory pattern in the Terra/Aqua MODIS SDSM Sun view response collected during the post-launch yaw maneuvers. The SDSM screen consists of small size pinholes which limit the screen transmittance. The SDSM Sun view transmittance pattern is affected by the size and distribution of pinholes, screen thickness, and orientation between the aperture stop and the Sun view screen. Planning of post-launch yaw maneuver test often requires comprehensive angular coverage to resolve the angular variation of the screen transmittance. This paper developed a Gauss-Kronrod quadrature method-based model to simulate the SDSM Sun view transmittance. This method performs iterative integration of the interception area between pinhole and aperture stop which is critical in the screen transmittance calculation. Parametric dependences of the MODIS SDSM Sun view transmittance on various geometric factors such as the pinhole size or spacing and misalignment between the SDSM Sun view screen and aperture stop are studied. The implications for the post-launch yaw maneuver planning to resolve the angular variation of the SDSM Sun view transmittance due to the SDSM Sun view screen misalignment are discussed.

MODIS↗

On-Orbit Performance of MODIS Solar Diffuser Stability Monitor

Moderate Resolution Imaging Spectroradiometer (MODIS) is currently operated on both the Terra and Aqua spacecraft. It collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands. MODIS RSB calibration is reflectance based via an on-board solar diffuser (SD). On-orbit changes in the SD bidirectional reflectance factor are tracked by an onboard solar diffuser stability monitor (SDSM). The SDSM functions as an independent ratioing radiometer with nine filtered detectors, covering wavelengths in the visible (VIS) and near-infrared (NIR) spectral regions. A brief overview of SDSM design functions, on-orbit operations, and performance for both Terra and Aqua MODIS is provided. In addition to the SD on-orbit degradation at different wavelengths, the changes in SDSM detector responses and their potential impact on tracking SD on-orbit degradation are examined. After more than 12 years of on-orbit operation, Aqua MODIS SD has shown degradation varying from 0.6% at 0.94 microns to 19.0% at 0.41 microns. Due to more frequent solar exposure and longer operation time, the Terra MODIS SD has experienced a much larger degradation, varying from 2.3% at 0.94 microns to 48.0% at 0.41 microns. For both Terra and Aqua MODIS, the SD has experienced more degradation at shorter wavelengths. Meanwhile, the SDSM detector responses have also experienced wavelength-dependent degradation. The largest change in the SDSM detector responses, however, occurred at longer NIR wavelengths. Since launch, the SDSM systems on both Terra and Aqua MODIS have continued their nominal operations, enabling critical parameters to be derived in support of the RSB on-orbit calibration. The calibration strategies developed for and lessons learned from MODIS SDSM operations, and a preliminary performance comparison with the S-NPP VIIRS SDSM are discussed.

MODIS↗

On-orbit Performance of MODIS Solar Diffuser Stability Monitor

MODIS has 20 reflective solar bands (RSBs) in the visible (VIS), near-infrared (NIR) , and shortwave infrared (SWIR) spectral regions. MODIS RSBs are calibrated on-orbit by a solar diffuser (SD) with its on-orbit degradation tracked by a solar diffuser stability monitor (SDSM). The SDSM is an instrument by itself, consisting of a solar integration sphere (SIS) with 9 individual filtered detectors covering wavelengths from 0.41 to 0.94 micrometers. It functions as a ratioing radiometer with alternate observations made of the direct sunlight (Sun view) and that diffusely reflected from the SD panel (SD view) during each scheduled SD/SDSM calibration event. Since launch, Terra and Aqua MODIS and their SDSM have successfully operated for more than 12 and 10 years, respectively. The VIIRS, on-board the newly launched Suomi National Polar orbiting Partnership (NPP) spacecraft, has been designed and built with strong MODIS heritage and carries a similar and improved SD and SDSM calibration system. This paper provides an overview of SDSM design functions, its on-orbit calibration strategies and performance for both Terra and Aqua MODIS missions. Discussions of its on-orbit performance are focused on changes in SDSM detector responses over time and their impact on tracking SD on-orbit degradation. Also presented in this paper are lessons learned from MODIS SDSM and improvements made for the VIIRS SDSM, and preliminary comparisons of their on-orbit performance.

Xiong, Xiaoxiong↗

MODIS Solar Diffuser Degradation Determination and Its Spectral Dependency

This study presents a modeling approach to improve solar diffuser (SD) degradation determination from SD stability monitor (SDSM) measurements. The MODIS instrument uses a SDto calibrate its reflective solar bands (RSBs) on-orbit. Due to the imperfectly designed SDSM sun view screen, the SD reflectance tracked by SDSM has large noise. The SDSM measurements noise is spectrally coherent and can be minimized by normalizing measurements to the least degradeddetector 9 (936 nm). In this study, a SD degradation model is used to determine the SDdegradation's wavelength dependency and the detector 9 degradation is estimated by the model solution.The results show the SD degradations measured at 6 SDSM detectors (554 _ 936 nm) have stable relationships, where the degradation is inversely proportion to 1/wavelength^4. The model estimated SD degradation at SDSM detector 9 wavelength (936 nm) is ~0.9% from 2002 to 2018.Based on the SD degradation model solution, the SD degradation at short/mid wave bands are estimated to improve short/mid wave bands calibration. The model can also be used to improve interpolating SD degradation at SDSM detectors to RSB wavelengths. Compared to linear interpolation, bands 9 and 10 show the largest differences of up to 0.3 and 0.4% respectively. These differences directly impact the calibration coefficients of these bands.

radiometric calibration↗

Performance of NOAA-20 VIIRS Solar Diffuser and Solar Diffuser Stability Monitor

Visible Infrared Imaging Radiometer Suite (VIIRS) radiometrically calibrates its reflective solar bands (RSBs) primarily through a sunlit onboard solar diffuser (SD). The sunlit SD provides a known radiance under the condition that the absolute product of the SD screen transmittance and the bidirectional reflectance distribution function (BRDF) along the SD-to-telescope direction is accurately known. The BRDF changes due to solar exposure. The change, referred to as the H-factor, is monitored by the onboard SD stability monitor (SDSM). The accuracy of the retrieved H-factor propagates to the retrieved F-factor which corrects the scene spectral radiance. High accuracy of the retrieved H-factor relies on high accuracies in the SDSM screen relative effective transmittance and the relative product of the SD screen effective transmittance and the BRDF at the mission start, and a high SDSM detector signal-to-noise ratio (SNR). This article briefly reviews the algorithms used for the NOAA-20 (N20) VIIRS RSB on-orbit radiometric calibration. Additionally, we show the performance of the N20 VIIRS SDSM, giving the SDSM detector SNRs and the SDSM detector gain temporal changes. We develop a model for the SNRs. The model shows that the decreased SNRs in time are due to the detector gain decreases. We also show the N20 VIIRS SD on-orbit performance, measured by the retrieved H-factor and the estimated standard deviation of its error. The H-factor for the telescope view is obtained from the H-factor for the SDSM view, multiplied by an H-factor angular dependence term. We use an innovative method to determine the angular dependence, using the dependence obtained for the Suomi National Polar-orbiting Partnership (SNPP) VIIRS.

VIIRS↗

S-NPP VIIRS Solar Diffuser Degradation at the View Direction of the Rotating Telescope Assembly

S-NPP VIIRS has been on-orbit for more than nine years since it was launched on October28th,2011. The VIIRS reflective solar bands (RSBs) are calibrated on-orbit primarily by an onboard solar diffuser (SD). The SD on-orbit degradation is tracked by an onboard SD stability monitor(SDSM). The VIIRS RSBs view the SD through a rotating telescope assembly (RTA). The RTA views the SD from a direction that is quite different from that of the SDSM. It has been shown that the SD degrades non-uniformly with respect to the incident and outgoing directions, especially at the short wavelengths. Thus, the SDSM calibration cannot provide an accurate SD degradation estimation for the view direction of the RTA, resulting in long-term drifts in the calibration coefficients derived from the SD and SDSM calibration. S-NPP VIIRS has been scheduled to view the Moon approximately monthly since its launch. The lunar observations can provide accurate long-term trends for the RSB calibration coefficients since the lunar surface reflectance is quite stable. By comparing the SD and lunar calibration results, we can obtain the SD degradation differences at the view directions of the SDSM and RTA and derive the SD degradation at the view direction of the RTA. Moreover, we can also derive the SD degradation in the short-wave infrared (SWIR) spectral range, wherein the SDSM cannot track the SD degradation. In this paper, we will derive the SD degradation for the view direction of the RTA from the SD, SDSM, and lunar calibrations from the visible to SWIR spectral range. We will also simulate the SD degradation with analytical models and compare their performances.

SNPP VIIRS↗

Assessment of MODIS and VIIRS Solar Diffuser On-Orbit Degradation

Both MODIS and VIIRS instruments use a solar diffuser (SD) for their reflective solar bands (RSB) on-orbit calibration. On-orbit changes in SD bi-directional reflectance factor (BRF) are tracked by a solar diffuser stability monitor (SDSM) using its alternate measurements of the sunlight reflected off the SD panel and direct sunlight through a fixed attenuation screen. The SDSM calibration data are collected by a number of filtered detectors, covering wavelengths from 0.41 to 0.94 micrometers. In this paper we describe briefly the Terra and Aqua MODIS and S-NPP VIIRS SDSM on-orbit operation and calibration activities and strategies, provide an overall assessment of their SDSM on-orbit performance, including wavelength-dependent changes in the SDSM detector responses and changes in their SD BRF, and discuss remaining challenging issues and their potential impact on RSB calibration quality. Due to different launch dates, operating configurations, and calibration frequencies, the Terra and Aqua MODIS and S-NPP VIIRS SD have experienced different amount of SD degradation. However, in general the shorter the wavelength, the larger is the SD on-orbit degradation. On the other hand, the larger changes in SDSM detector responses are observed at longer wavelengths in the near infrared (NIR).

MODIS↗

Impacts of the Angular Dependence of the Solar Diffuser BRDF Degradation Factor on the SNPP VIIRS Reflective Solar Band On-Orbit Radiometric Calibration

Using an onboard sunlit solar diffuser (SD) as the primary radiance source, the visible infrared imaging radiometer suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs radiometric calibration of its reflective solar bands (RSBs). The SD bidirectional reflectance distribution function (BRDF) value decreases over time. A numerical degradation factor is used to quantify the degradation and is determined by an onboard SD stability monitor (SDSM), which observes the sun and the sunlit SD at almost the same time. We had shown previously that the BRDF degradation factor was angle-dependent. Consequently, due to that the SDSM and the RSB view the SD at very different angles relative to both the solar and the SD surface normal vectors, directly applying the BRDF degradation factor determined by the SDSM to the VIIRS RSB calibration can result in large systematic errors. We develop a phenomenological model to calculate the BRDF degradation factor for the RSB SD view from the degradation factor for the SDSM SD view. Using the yearly undulations observed in the VIIRS detector gains for the M1-M4 bands calculated with the SD BRDF degradation factor for the SDSM SD view and the difference between the VIIRS detector gains calculated from the SD and the lunar observations, we obtain the model parameter values and thus establish the relation between the BRDF degradation factors for the RSB and the SDSM SD view directions.

Lei, Ning↗

Determination of the NOAA-20 VIIRS screen transmittance functions with both the yaw maneuver and regular on-orbit calibration data

The Visible Infrared Imaging Radiometer Suite (VIIRS) aboard theNOAA-20 satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs) through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and then scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD’s bidirectional reflectance distribution function (BRDF), referred to as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM) whose eight detectors alternately observe the Sun through another attenuation screen (the SDSM screen) and the sunlit SD. The products of the SD screen transmittance and the BRDF at the mission start for both the SDSM and RSBs and the SDSM screen effective transmittance were measured prelaunch. Large unrealistic undulations in the retrieved H-factor were seen when using the prelaunch screen functions. To improve the accuracy of the retrieved H-factor, shortly after the satellite launch, 15 yaw maneuvers were performed to further characterize the screens. Although significantly improved, the H-factor derived using the screen functions determined fromthe yaw maneuver data still has large unrealistic undulations, revealing that the solar azimuth angular step size of the yaw maneuvers is too large. In this paper,we add high-quality regular on-orbitSDcalibration data to the yaw maneuver data to further improve the relative product of the SD screen effective transmittance and the BRDF at the mission start for the SDSM and the SDSM screen relative effective transmittance. The H-factor time series derived from the newly determined screen transmittance functions is much smoother than that derived from using only the yaw maneuver data and thus considerably improves the radiometric calibration accuracy.

Ning Lei↗

Characterization of MODIS Solar Diffuser On-orbit Degradation

MODIS reflective solar bands (RSB) are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD bi-directional reflectance factor (BRF) was characterized pre-launch by the instrument vendor using reference samples traceable to NIST reflectance standards. Its on-orbit degradation is regularly monitored by the SDSM. It consists of a solar integration sphere (SIS) with 9 filtered detectors with wavelengths ranging from 0.41 to 0.94 micrometer, a rotating mirror assembly, and an electronics module. During each SD/SDSM calibration, the SDSM views the sunlight directly and the sunlight diffusely reflected from the SD panel. The time series of SDSM measurements (ratio of the SD view response to the Sun view response) is used to compute the SD BRF degradation at each SDSM detector wavelength. Since launch Terra MODIS has operated for more than seven years and Aqua for nearly five years. The SD panel on each MODIS instrument has experienced noticeable degradation with the largest changes observed in the VIS spectral region. Following a brief description of the MODIS RSB calibration methodology and SD/SDSM operational activities, this paper illustrates the SD on-orbit degradation results for both Terra and Aqua MODIS. It discusses the impacts on the SD RF degradation due to sensor operational conditions and SD solar exposure time. For Aqua MODIS, operated under the same conditions, the SD annual degradation rate is approximately 2.9% at 0.41 micrometers, 1.6% at 0.47 micrometers, and less than 1.1% at wavelengths above 0.53 micrometers. For Terra MODIS, however, an SD door (SDD) related anomaly in May 2003 had led to a decision to keep the SDD permanently at its open position. Since then its SD has experienced a much faster SD degradation rate.

Xiong, X.↗

On-Orbit Performance of MODIS Solar Diffuser Stability Monitor

MODIS reflective solar bands (RSB) calibration is provided by an on-board solar diffuser (SD). On-orbit changes in the SD bi-directional reflectance factor (BRF) are tracked by a solar diffuser stability monitor (SDSM). The SDSM consists of a solar integration sphere (SIS) with nine detectors covering wavelengths from 0.41 to 0.94 microns. It functions as a ratioing radiometer, making alternate observations of the sunlight through a fixed attenuation screen and the sunlight diffusely reflected from the SD during each scheduled SD/SDSM calibration event. Since launch, Terra and Aqua MODIS SD/SDSM systems have been operated regularly to support the RSB on-orbit calibration. This paper provides an overview of MODIS SDSM design functions, its operation and calibration strategies, and on-orbit performance. Changes in SDSM detector responses over time and their potential impact on tracking SD on-orbit degradation are examined. Also presented in this paper are lessons learned from MODIS SD/SDSM calibration system and improvements made to the VIIRS SD/SDSM system, including preliminary comparisons of MODIS and VIIRS SDSM on-orbit performance.

MODIS↗

Suomi-NPP VIIRS Solar Diffuser Stability Monitor Performance

When illuminated by the Sun, the onboard solar diffuser (SD) panel provides a known spectral radiance source to calibrate the reflective solar bands of the Visible Infrared Imaging Radiometer Suite on the Suomi-NPP satellite. The SD bidirectional reflectance distribution function (BRDF) degrades over time due to solar exposure, and this degradation is measured using the SD stability monitor (SDSM). The SDSM acts as a ratioing radiometer, comparing solar irradiance measurements off the SD panel to those from a direct Sun view. We discuss the design and operations of the SDSM, the SDSM data analysis, including improvements incorporated since launch, and present the results through 1000 days after launch. After 1000 days, the band-dependent H-factors, a quantity describing the relative degradation of the BRDF of the SD panel since launch, range from 0.716 at 412 nanometers to 0.989 at 926 nanometers. The random uncertainty of these H-factors is about 0.1 percent, which is confirmed by the similar standard deviation values computed from the residuals of quadratic exponential fits to the H-factor time trends. The SDSM detector gains have temperature sensitivity of up to about 0.36 percent per kelvin, but this does not affect the derived H-factors. An initial error in the solar vector caused a seasonal bias to the H-factors of up to 0.5 percent. The total exposure of the SD panel to UV light after 1000 orbits is equivalent to about 100 hours of direct sunlight illumination perpendicular to the SD panel surface.

Fulbright, Jon↗

Initial Determination of the NOAA-20 VIIRS Screen Transmittances with Both Yaw Maneuver and Regular on Orbit Data

One of the scientific instruments aboard the NOAA-20 satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). The VIIRS regularly performs on-orbit radiometric calibration of its reflective solar bands, primarily through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD bidirectional reflectance distribution function (BRDF), denoted as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM). The eight SDSM detectors observe the sun through another attenuation screen (the SDSM screen) and the sunlit SD almost at the same time to measures the SD BRDF change. The products of the SD screen transmittance and the BRDF at t=0 and the SDSM screen transmittance were measured prelaunch. Large undulations in the H-factor were seen when using the prelaunch screen transmittances. Fifteen on-orbit yaw maneuvers were performed to validate and to further characterize the screens. Although significantly improved, the H-factor from the yaw maneuver data determined screen transmittance still has undulations as large as about 0.7-0.8%, revealing that the angular step size of the yaw maneuvers is too large. In this paper, we add regular on-orbit data to the yaw maneuver data to further improve the relative products and the relative SDSM screen transmittance. The H-factor time series derived from the newly determined screen transmittance is much smoother than that derived from using only the yaw maneuver data and thus improves considerably the radiometric calibration accuracy.

Lei, Ning↗