Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

Response of a DRAM to single-ion tracks of different heavy-ion species and stopping powers

Multiple-bit errors caused by single-ion tracks in a 256-kb DRAM fabricated by a bulk process were observed for different ion species and stopping power values. The results demonstrate the utility of this device for the evaluation of ion-beam uniformity and ion-beam-induced charge collection in IC devices. The data indicate that single-ion-induced charge transport results in multiple-bit error clusters due to lateral diffusion of excess minority carriers (electrons). Charge collection occurred from a depth of up to 35 microns from the surface of the device. An apparent charge loss was observed for very heavy ions with a high stopping power (Au at 350 MeV).

Zoutendyk, J. A.↗

Preparation and Characterization of Single Ion Conductors from High Surface Area Fumed Silica

Anions that can form dissociative salts with Li(+) have been prepared and covalently attached to high surface area fumed silica. When blended with polyethylene oxide (PEO), the functionalized fumed silica suppresses the crystallization of the PEO, provides dimensional stability, and serves as a single ion conductor. Since functionalized fumed silica is easily dispersed in common polar solvents, it can be incorporated in both the polymer electrolyte and the electrodes.

Zhang, H.↗

Multiple-Bit Errors Caused By Single Ions

Report describes experimental and computer-simulation study of multiple-bit errors caused by impingement of single energetic ions on 256-Kb dynamic random-access memory (DRAM) integrated circuit. Studies illustrate effects of different mechanisms for transport of charge from ion tracks to various elements of integrated circuits. Shows multiple-bit errors occur in two different types of clusters about ion tracks causing them.

Zoutendyk, John A.↗

Characterization of multiple-bit errors from single-ion tracks in integrated circuits

The spread of charge induced by an ion track in an integrated circuit and its subsequent collection at sensitive nodal junctions can cause multiple-bit errors. The authors have experimentally and analytically investigated this phenomenon using a 256-kb dynamic random-access memory (DRAM). The effects of different charge-transport mechanisms are illustrated, and two classes of ion-track multiple-bit error clusters are identified. It is demonstrated that ion tracks that hit a junction can affect the lateral spread of charge, depending on the nature of the pull-up load on the junction being hit. Ion tracks that do not hit a junction allow the nearly uninhibited lateral spread of charge.

Zoutendyk, J. A.↗

Heavy ion action on single cells: Cellular inactivation capability of single accelerated heavy ions

Heavy ions (HZE-particles) constitute an important part of radiation in space. Although their number is small the high amount of energy transferred by individual particles may cause severe biological effects. Their investigation requires special techniques which were tested by experiments performed at the UNILAC at the GSI (Darmstadt). Diploid yeast was used which is a suitable eucaryotic test system because of its resistance to extreme conditions like dryness and vacuum. Cells were placed on nuclear track detector foils and exposed to ions of different atomic number and energy. To assess the action of one single ion on an individual cell, track parameters and the respective colony forming abilities (CFA) were determined with the help of computer aided image analysis. There is mounting evidence that not only the amount of energy deposited along the particle path, commonly given by the LET, is of importance but also the spatial problem of energy deposition at a submicroscopical scale. It is virtually impossible to investigate track structure effects in detail with whole cell populations and (globally applied) high particle fluences. It is, therefore, necessary to detect the action of simple ions in individual cells. The results show that the biological action depends on atomic number and specific energy of the impinging ions, which can be compared with model calculations of recent track structure models.

Kost, M.↗

Norbornene-Based Polymer Electrolytes for Lithium Cells

Norbornene-based polymers have shown promise as solid electrolytes for lithium-based rechargeable electrochemical cells. These polymers are characterized as single-ion conductors. Single-ion-conducting polymers that can be used in lithium cells have long been sought. Single-ion conductors are preferred to multiple-ion conductors as solid electrolytes because concentration gradients associated with multiple-ion conduction lead to concentration polarization. By minimizing concentration polarization, one can enhance charge and discharge rates. Norbornene sulfonic acid esters have been synthesized by a ring-opening metathesis polymerization technique, using ruthenium-based catalysts. The resulting polymer structures (see figure) include sulfonate ionomers attached to the backbones of the polymer molecules. These molecules are single-ion conductors in that they conduct mobile Li+ ions only; the SO3 anions in these polymers, being tethered to the backbones, do not contribute to ionic conduction. This molecular system is especially attractive in that it is highly amenable to modification through functionalization of the backbone or copolymerization with various monomers. Polymers of this type have been blended with poly(ethylene oxide) to lend mechanical integrity to free-standing films, and the films have been fabricated into solid polymer electrolytes. These electrolytes have been demonstrated to exhibit conductivity of 2 10(exp -5)S/cm (which is high, relative to the conductivities of other solid electrolytes) at ambient temperature, plus acceptably high stability. This type of norbornene-based polymeric solid electrolyte is in the early stages of development. Inasmuch as the method of synthesis of these polymers is inherently flexible and techniques for the fabrication of the polymers into solid electrolytes are amenable to optimization, there is reason to anticipate further improvements.

Cheung, Iris↗

Shock normal determination for multiple-ion shocks

We have adapted the single-ion Vinas and Scudder (1986) solution to the Rankine-Hugoniot (R-H) problem to a multiple-on solution. Using this technique, we can calculate a shock normal direction, shock speed, best estimate of the upstream and downstream magnetic field and plasma asymptotic states, and theta(sub Bn), the angle between the shock normal and the upstream magnetic field. We test the multi-ion solution with a theoretical case but are restricted to a perpendicular shock in order to close the multi-ion Rankine-Hugoniot equations. For this test case both single-ion and multi-ion solutions are equally valid. We examine parameter regimes to look for differences between single-ion and multi-ion solutions of the R-H equations, and we find that the largest differences occur for quasi-parallel shocks, small values of solar wind speed, large values of heavy ion density, and very strong and very weak shocks. For both the inbound and outbound crossing of comet Halley we have a slow solar wind speed, small values of water group ions and fairly weak shocks. We examine both the quasi-perpendicular inbound crossing and the quasi-parallel outbound crossing at comet Halley.

Kessel, R. L.↗

Bond Dissociation Energies of the Tungsten Fluorides and Their Singly-Charged Ions: A Density Functional Survey

The dissociation of WF6 and the related singly-charged cations and anions into the lower fluorides and fluorine atoms has been investigated theoretically using density functional theory (B3LYP) and relativistic effective core potentials, with estimates of spin-orbit effects included using a simple model. The inclusion of spin-orbit is essential for a correct description of the thermochemistry. The total atomization energy of the neutral and anionic WF6 is reproduced to within 25 kcal/mol, but comparison of individual bond dissociation energies with available experimental data shows discrepancies of up to 10 kcal/mol. The results are nevertheless useful to help resolve discrepancies in experimental data and provide estimates of missing data.

Dyall, Kenneth G.↗

Electronic drive and acquisition system for mass spectrometry

The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.

Schaefer, Rembrandt Thomas↗

Mixed-field GCR Simulations for Radiobiological Research Using Ground Based Accelerators

Space radiation is comprised of a large number of particle types and energies, which have differential ionization power from high energy protons to high charge and energy (HZE) particles and secondary neutrons produced by galactic cosmic rays (GCR). Ground based accelerators such as the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) are used to simulate space radiation for radiobiology research and dosimetry, electronics parts, and shielding testing using mono-energetic beams for single ion species. As a tool to support research on new risk assessment models, we have developed a stochastic model of heavy ion beams and space radiation effects, the GCR Event-based Risk Model computer code (GERMcode). For radiobiological research on mixed-field space radiation, a new GCR simulator at NSRL is proposed. The NSRL-GCR simulator, which implements the rapid switching mode and the higher energy beam extraction to 1.5 GeV/u, can integrate multiple ions into a single simulation to create GCR Z-spectrum in major energy bins. After considering the GCR environment and energy limitations of NSRL, a GCR reference field is proposed after extensive simulation studies using the GERMcode. The GCR reference field is shown to reproduce the Z and LET spectra of GCR behind shielding within 20% accuracy compared to simulated full GCR environments behind shielding. A major challenge for space radiobiology research is to consider chronic GCR exposure of up to 3-years in relation to simulations with cell and animal models of human risks. We discuss possible approaches to map important biological time scales in experimental models using ground-based simulation with extended exposure of up to a few weeks and fractionation approaches at a GCR simulator.

Kim, Myung-Hee Y.↗

Mechanisms of Heavy Ion-Induced Single Event Burnout in 4H-SiC Power MOSFETs

This describes the mechanisms behind the failure of 4H-SiC Power MOSFETs when struck by a heavy ion. The modeled device is designed to simulate a commercially available 1200 V power MOSFET and the ion simulated is a silver ion with a Linear Energy Transfer of 46 MeV-cm2/mg commonly used in single event effect (SEE) testing. The device is shown in simulation to fail near 500 V, which is in close agreement to experiments. These simulations go to show that the failure of SiC MOSFET occurs near the interface between the epi and substrate layers due to the rapid increase of the electric field in that region and destruction of the device from impact ionization. From this, two designs were proposed and investigated that would help to mitigate the electric field in these regions and improve the device's tolerance to single-event burnout (SEB). The new designs increased the voltage at which SEB occurs from 500 V to over 900 V and increased the Ron,sp by only 5%.

Mcpherson, Joseph A.↗

CMOS RAM cosmic-ray-induced-error-rate analysis

A significant number of spacecraft operational anomalies are believed to be associated with cosmic-ray-induced soft errors in the LSI memories. Test programs using a cyclotron to simulate cosmic rays have established conclusively that many common commercial memory types are vulnerable to heavy-ion upset. A description is given of the methodology and the results of a detailed analysis for predicting the bit-error rate in an assumed space environment for CMOS memory devices. Results are presented for three types of commercially available CMOS 1,024-bit RAMs. It was found that the HM6508 is susceptible to single-ion induced latchup from argon and krypton ions. The HS6508 and HS6508RH and the CDP1821 apparently are not susceptible to single-ion induced latchup.

Pickel, J. C.↗

Texas Instrument DRV8881 2.5A Dual H-Bridge Motor Driver Heavy-Ion Single-Event Effects Test Report

The purpose of this test was to characterize the single-event effects (SEE) susceptibility of the Texas Instrument (TI) DRV8881 2.5A Dual H-Bridge Motor Driver. The device’s output was monitored for changes during exposure to heavy-ions at Lawrence Berkeley National Laboratory (LBNL) 88-inch Cyclotron. The main goal of testing was to test for destructive SEEs. Nondestructive SEEs were recorded during testing but not fully characterized. Testing was performed on November 9th and 11th, 2022.

Thomas A. Carstens↗

Development of Highly-Conductive Polyelectrolytes for Lithium Batteries

Future NASA and Air Force missions require reliable and safe sources of energy with high specific energy and energy density that can provide thousands of charge-discharge cycles at more than 40% depth- of-discharge and that can operate at low temperatures. All solid-state batteries have substantial advantages with respect to stability, energy density, storage fife and cyclability. Among all solid-state batteries, those with flexible polymer electrolytes offer substantial advantages in cell dimensionality and commensurability, low temperature operation and thin film design. The above considerations suggest that lithium-polymer electrolyte systems are promising for high energy density batteries and should be the systems of choice for NASA and US Air Force applications. Polyelectrolytes (single ion conductors) are among most promising avenues for achieving a major breakthrough 'in the applicability of polymer- based electrolyte systems. Their major advantages include unit transference number for the cation, reduced cell polarization, minimal salt precipitation, and favorable electrolyte stability at interfaces. Our research is focused on synthesis, modeling and cell testing of single ion carriers, polyelectrolytes. During the first year of this project we attempted the synthesis of two polyelectrolytes. The synthesis of the first one, the poly(ethyleneoxide methoxy acrylateco-lithium 1,1,2-trifluorobutanesulfonate acrylate, was attempted few times and it was unsuccessful. We followed the synthetic route described by Cowie and Spence. The yield was extremely low and the final product could not be separated from the impurities. The synthesis of this polyelectrolyte is not described in this report. The second polyelectrolyte, comb polysiloxane polyelectrolyte containing oligoether and perfluoroether sidechains, was synthesized in sufficient quantity to study the range of properties such as thermal stability, Li- ion- conductivity and stability toward lithium metal. Also, the batteries containing this polyelectrolyte were assembled and tested. The results are detailed below. The synthesis of another polyelectrolyte similar to polysiloxane polyelectrolyte has been started, however, the synthesis was not completed due to termination of the project.

Shriver, D. F.↗