Search NASA⌕ Search

SEARCH · Search NASA

Results for “STATIC INVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Wind Power as a Virtual Synchronous Generator (WindVSG)

This project investigated the theory, implemented it in hardware, and validated the Wind as a Virtual Isochronous Generator (WindVSG) concept by combining the advantages of modern dynamic inverter technologies with static, dynamic, and transient electromechanical properties of synchronous machines. During this project we demonstrated how to control the inverters of wind turbine generators (wind alone or in parallel with other GFM sources, such battery energy storage) so that wind power behaves like a synchronous machine-based power plant with a conventional prime mover. For this purpose, testing was conducted at NLR ARIES facility with real 2.5 MW wind-turbine generator operating in GFM mode under dynamic and transient conditions. The team also developed models and conducted simulations for GFM wind power to evaluate stability impacts of GFM operation on power grid. This report describes efforts by the NLR team working in collaboration GE Vernova during 3-year project.

17 WIND ENERGY↗

Unveiling the structural transformations in glassy solid electrolyte adapted to high-stress cycles

Brittleness of glass–ceramic and ceramic ion conductors is considered as a main roadblock for their implementation as electrolytes in solid-state batteries where the fractures often occur due to the pressure exerted by metallic lithium. In this regard, nano- and micro-scale ductility of the solid electrolyte allows reducing such pressure without formation of cracks. Among different types of solid state ion conductors, phosphate invert glasses seem to be promising in achieving such ductility. We report the mechanical behavior of lithium phosphorous oxynitride (LiPON) invert glass probed by static and cyclic nanoindentation. Repeated application of high intensity stress results in densification and shear deformation of material allowing LiPON to accommodate the ~ 22% nominal strain imposed by the nanoindenter without cracking. Ability to do this under repeated loading indicates robustness of LiPON when used in lithium metal batteries under cyclic charge and discharge. Using Raman spectroscopy with unsupervised K-means clustering we reveal pressure-induced formation of P 2 O 7 units which migrate to the periphery of the residual hardness impressions with cycling resulting in surface morphology of LiPON superficially similar to that of deformed bulk metallic glass.

36 MATERIALS SCIENCE↗

Superionic fluoride gate dielectrics with low diffusion barrier for two-dimensional electronics

Exploration of new dielectrics with a large capacitive coupling is an essential topic in modern electronics when conventional dielectrics suffer from the leakage issue near the breakdown limit. Here, to address this looming challenge, we demonstrate that rare-earth metal fluorides with extremely low ion migration barriers can generally exhibit an excellent capacitive coupling over 20 μF cm -2 (with an equivalent oxide thickness of ~0.15 nm and a large effective dielectric constant near 30) and great compatibility with scalable device manufacturing processes. Such a static dielectric capability of superionic fluorides is exemplified by MoS 2 transistors exhibiting high on/off current ratios over 10 8 , ultralow subthreshold swing of 65 mV dec -1 and ultralow leakage current density of ~10 -6 A cm -2 . Therefore, the fluoride-gated logic inverters can achieve notably higher static voltage gain values (surpassing ~167) compared with a conventional dielectric. Furthermore, the application of fluoride gating enables the demonstration of NAND, NOR, AND and OR logic circuits with low static energy consumption. In particular, the superconductor–insulator transition at the clean-limit Bi 2 Sr 2 CaCu 2 O 8+δ can also be realized through fluoride gating. In conclusion, our findings highlight fluoride dielectrics as a pioneering platform for advanced electronic applications and for tailoring emergent electronic states in condensed matter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uninterruptible Power Supply Systems, UTrain Course 58423 [Slides]

Identify the principles of operation of uninterruptible power supply (UPS) systems, focusing on double conversion and offline/standby/backup types. The traditional UPS is now referred to as a “double conversion” UPS. The AC input power is rectified into DC. The DC feeds an inverter which provides the AC output. The DC bus is also connected to batteries. It is called double conversion because the first conversion is from AC to DC and the second conversion is from DC to AC. The inverter creates the output waveform to match the bypass input. Because of this, the static bypass switch may be switched between inverter and bypass seamlessly.

42 ENGINEERING↗

Measurement of the Static Nonlinear Third-Order Elastic Moduli of Rocks: Problems and Applicability

The third-order elastic (TOE) model has been used to describe the widely observed nonlinear mechanical behaviors of earth materials. In addition to linear elastic constants ( λ , μ ), three nonlinear elastic moduli ( A , B , C ) are required for isotropic rocks. Contrary to previous research on dynamic TOE moduli, this study followed the protocol to measure strain and stress under uniaxial and hydrostatic compressive tests statically, which were later used to invert for the full set of TOE moduli for four standard rock types with differing pore structures of a porous oolitic limestone, quartz-rich sandstones, and a dense crystalline basalt. The applicability of the TOE model to characterize nonlinearity depends on the fulfillment of path-independence and small-strain assumptions. Using the measured static TOE moduli, the finite element model demonstrates that the stress in the vicinity of the wellbore is more amplified than the stress in the linear elastic case, which leads to a wider zone of rock failure around the wellbore. Due to the long-standing discrepancy between static and dynamic moduli, the rarely reported full set of static TOE moduli is necessary and will benefit future research in understanding the effect of rock nonlinearity on geophysical and geomechanical applications, such as long-term safe storage of CO 2 and generating process of geohazards.

58 GEOSCIENCES↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗