Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Sensor system and method

A sensor system includes a sensing element having a section of a layer assembly deposited onto a substrate. The layer assembly includes plural layers of different materials. The section of the layer assembly is configured to be etched to form plural individual pillars of the plural layers of the different materials. The individual pillars are configured to be in contact with a fluid to sense one or more analyte fluid components within the fluid. The sensing element is configured to generate a sensor signal responsive to the individual pillars being in contact with the fluid. The sensor system includes one or more processors configured to receive the sensor signal from the sensing element. The one or more processors may identify the one or more analyte fluid components within the fluid and an amount of each of the analyte fluid components within the fluid based on the sensor signal.

Potyrailo, Radislav Alexandrovich↗

Gas sensor system

A gas sensor system includes a sensing tube having an outer surface, and an inner surface defining a passage. A plurality of openings is formed through the outer surface and the inner surface. Each of the plurality of openings being no greater than 0.5 millimeters (mm) in diameter. A hydrophobic sealant layer covers the sensing tube. A protective layer covers the hydrophobic sealant layer. A sensor node is arranged along the sensing tube. The sensor node includes an inlet, an outlet, and an interior chamber arranged between the inlet and the outlet. A sensor element is arranged in the sensor node. The sensor element includes a first end and a second end. A sensor cable extends along the sensing tube. The sensor cable includes a first section connected to the first end of the sensor element and a second section connected to the second end of the sensor element.

47 OTHER INSTRUMENTATION↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗

Deployable sensor system using mesh networking and satellite communication

A sensor system may be configured for continuous operation in a low resource environment and/or in extreme environmental conditions. The sensor system may have sufficient processing capabilities to provide scientific computing for pre-processing, quality control, statistical analysis, event classification, data compression and corrections (e.g., spikes in the data), autonomous decisions and actions, triggering other nodes, and information assurance functions that provide data confidentiality, data integrity, authentication, and non-repudiation. The hardware may have both mesh networking and satellite and cellular communication capability, and may be available for relatively low cost. Such a network provides the flexibility to have potentially any number of nodes be completely independent from one another. Thus, the network may scale across a diverse terrain.

Frigo, Janette↗

Stripline Block Sensor System

The Long Baseline Neutrino Facility requires a secondary sensor system to aid in the installation and replacement of the stripline blocks. These blocks are responsible for delivering large amounts of current to the horn and must be installed with high precision to avoid possible physical damage. There are many constraints due to the modules' surroundings, such as small clearances and a highly radioactive environment. Existing systems have already been implemented within the process; however, these systems offer limited information, leaving much risk during operations. This calls for a sufficiently accurate sensor system, which has a small space requirement and provides valuable information throughout the replacement period. A variety of methods and technologies were explored to provide an applicable approach to the issue. The proposed solution consisted of the use of retroreflective and target, however, it cannot provide positional feedback throughout the entire process. A proposed alternative utilizes a three-dimensional indoor positioning system to provide the operator with real-time positioning and rotational information. Sensors placed on the module and stripline would communicate with fixed receivers surrounding the target hall to provide precise positional feedback. However, this solution may still contain line-of-sight issues as well as installation complications due to the radioactive environment. Future work would consist of finding vendors capable of providing technology that fits our constraints, proof of concept tests for both solutions, implementation planning, and trials within the target hall itself. Due to its ability to provide continuous positional and rotational feedback, the indoor positioning system is the most suitable solution for accurately installing the stripline block.

Espinoza, David [Unlisted, US]↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microbial sensor system for monitoring the environment and surfaces

A microbial sensor, system and method that can be used to determine the biochemical conditions of waters, saturated sediments, unsaturated soils, rhizosphere and other environments is disclosed. The flexibility of the microbial sensor design allows for the monitoring of surfaces (skin, ventilation conduits, etc.). An electrochemical microbial sensor system is composed of an indicator electrode(s) and a reference electrode. The reference electrode employs a hydrogen permeable membrane. The electrochemical system is interfaced into a signal/communication module allowing the manual or automated collection of data from field deployments and laboratory investigations. The data is transmitted using various communication technologies including Bluetooth™, cellular, satellite and radio telemetry to cloud-based data management systems. The stored data may be downloaded by users using open-source dashboard and visualization software to image the various environments and/or surfaces investigated.

Burge, Scott R.↗

Microbial sensor system for the assessment of subsurface environments

A microbial sensor, system, and method that can be used to determine a chemical environment and/or substrate concentrations in anaerobic or aerobic environments, such as soils, sediments and ground waters, are disclosed. An exemplary system uses one or more (e.g., inert) measurement electrodes and a reference electrode. The reference electrode can include an electrode exposed to atmospheric oxygen (e.g., a cathode) or an electrode exposed to stable anaerobic or aerobic conditions. The exemplary microbial sensor system measures open-circuit voltage to characterize the chemical (oxidizing or reducing) environment and/or recovery voltage to measure substrate concentrations in the subsurface.

Burge, Scott R.↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Inductive circuit sensor system and method

An inductive circuit sensor system and method for monitoring an electromagnetic signal path through a circuit is shown. A protected element or door is movably positionable adjacent to the stationary element or frame in a monitored position. A conductive sensor pattern element is connected to a pair of inductive coils. The pattern element is a conductive wire traversing a predetermined cross-section of the door. The frame has a transmitting coil in communication with a microcontroller. The transmitting coil is coupled with the first coil and a receiving coil is coupled with the second coil. The transmitting coil receives a signal from the microcontroller and couples the signal to the pattern element. The signal is in communication with a receiving port on the microcontroller. The microcontroller is programmed to compare the signal from the transmit port with the signal at the receiving port.

Neidigk, Stephen↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

Sensor system and implementation of the same

Various embodiments described in the disclosure relate to wireless sensor systems. Some embodiments specifically relate to unitary modules for sensing, power, processing, communication, and data storage; and that may be connected by a common interface to form a wireless sensor system.

Agarwal, Vivek↗

Workshop on Integrated Sensor Systems for Manufacturing Applications (Workshop Report)

On January 25th and 26th, the Department of Energy’s Advanced Manufacturing Office (AMO) held the first in a series of workshops on different topics related to semiconductor research and development (R&D). This workshop focused on integrated sensor system R&D for manufacturing applications. As AMO is housed within the office of Energy Efficiency and Renewable Energy (EERE), the workshop addressed not only industry needs and R&D opportunities, but also the impacts that improvements in sensor systems can have on energy efficiency and greenhouse gas production. The output of this workshop will inform AMO’s future portfolio of R&D investments, provide perspectives on trends, drivers, and challenges for next generation semiconductor sensor systems, and help the stakeholder community understand the opportunities on the horizon.

36 MATERIALS SCIENCE↗

AOI [1]: Passive Wireless Sensor Systems Fabricated by Direct-Writing for Temperature and Health Monitoring of Energy Systems in Harsh-Environments (Final Report)

Researchers at West Virginia University (WVU) propose to demonstrate a wireless, high-temperature sensor system for monitoring the temperature and health of energy-system components. The active sensor and electronics for wireless communication will be composed entirely of an electroceramic materials (conductive ceramics) which are capable of withstanding the harsh-environments required for fossil energy-based technologies. This work will focus primarily on the fabrication and testing of temperature (thermocouples and thermistors) and health (strain/stress and crack propagation sensors) that function at extreme temperatures (up to 700-1700ºC). The electronics will accompany the high-temperature sensor, which will include a passive wireless communication circuit that allows the transmission of the data based on the LCR resonance principle to a near-by reader antenna. This passive transmission of data will reduce the need for interconnect wires near the active, and possibly rotating, energy-system component. The research will include process development to permit the 2D/3D direct-writing of the entire sensor and communication circuit onto the energy-system component. The direct-writing will be facilitated by using silicon-based polymer-derived precursors to form the high-temperature, stable electroceramic compositions. In addition, methods for direct-writing the circuit onto a fugitive carrier substrate will be completed, which will permit a “peel-and-stick”-like transfer of the sensor circuit to the energy-system component. This feature will allow the economical and precise placement of the sensor circuit onto components of various shapes and locations, without altering the geometry and active features of the manufactured component, or the removal (or decommissioning) of the component for installation. The proposed work will be directed at the following areas: 1) Investigation of phase formation, sintering/grain growth, and electrical properties of polymer-derived electroceramic composites; 2) Definition of processes to direct-write through ink-jet and robo-casting the polymer-derived electroceramic composites onto oxide and polymer surfaces; 3) Development of methods to form monolithic "peel-and-stick" preforms that will efficiently transfer the sensor circuit to ceramic surfaces after thermal treatment; 4) Design of passive wireless LCR circuits and receiver (reader) antennas for communication and testing at high temperatures; 5) Investigation of the passive wireless sensor system developed (and method of transferring sensor system) for temperature and stress/strain measurements on a SOFC repeat unit and a singular gas turbine blade prototype as example applications.

01 COAL, LIGNITE, AND PEAT↗

Amperometric electrochemical sensors, sensor systems and detection methods

An amperometric electrochemical sensor for measuring the concentrations of one or more target gas species in a gas sample or gas stream, the sensor having at least one electrochemical cell with first and second surface electrodes, an electrolyte layer and a passive signal amplifying layer (“SAL”) comprising electrically conductive material like platinum, wherein at least a portion of the electrolyte layer is located between the surface electrodes and the SAL such that the SAL is in direct, conductive contact with the electrolyte layer but is not in direct contact with the surface electrodes. Sensor systems and detection methods are also provided.

Arkenberg, Gene B.↗