Search NASA⌕ Search

SEARCH · Search NASA

Results for “Server power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wide Bandgap Semiconductor Opportunities in Power Electronics

The report objective is to explore the Wide Bandgap (WBG) Power Electronics (PE) market, applications, and potential energy savings in order to identify key areas where further resources and investments of the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE EERE) would have the most impact on U.S. competiveness. After considering the current market, several potential near-term application areas were identified as having significant market and energy savings potential with respect to clean energy applications: (1) data centers (uninterruptible power supplies and server power supplies); (2) renewable energy generation (photovoltaic-solar and wind); (3) motor drives (industrial, commercial and residential); (4) rail traction; and, (5) hybrid and electric vehicles (traction and charging). After the initial explorative analyses, it became clear that, SiC, not GaN, would be the principal WBG power device material for the chosen markets in the near future. Therefore, while GaN is discussed when appropriate, this report focuses on SiC devices, other WBG applications (e.g., solid-state transformers, combined heat and power, medical, and wireless power), the GaN market, and GaN specific applications (e.g., LiDAR, 5G) will be explored at a later date. In addition to the market, supply and value chain analyses addressed in Section 1 of this report, a SWOT (Strength, Weakness, Opportunity, Threat) analysis and potential energy savings analysis was conducted for each application area to identify the major potential WBG application area(s) with a U.S. competitiveness opportunity in the future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparing datasets of volume servers to illuminate their energy use in data centers

As data centers proliferate, their energy intensity deserves close attention. Always-on operations and growing usage for cloud and other backend processes make servers the fundamental driver of data center energy use. Yet servers’ power draw under real-world conditions is poorly understood. This paper explores characteristics of volume servers that affect energy use, quantifying differences in power draw between higher-performing Standard Performance Evaluation Corporation (SPEC) and ENERGY STAR servers and that of a typical server. First, we establish general characteristics of the US installed base, before reporting hardware configurations from a major online retail website. We then compare idle power across three datasets (one unique to this paper) and explain their differences via the hardware characteristics to which power draw is most sensitive. We find idle server power demand to be significantly higher than benchmarks from ENERGY STAR and the industry-released SPEC database, and SPEC server configurations—and likely their power scaling—to be atypical of volume servers. Next, we examine power draw trends among high-performing servers across their load range to consider whether these trends are representative of volume servers, before inputting average idle power load values into a recent national server energy use model. Lastly, results from two surveys of IT professionals illustrate the incidence of more efficient equipment and operational practices in server rooms/closets. Future work should include server power field measurements in data centers of different sizes, accounting for variations in configurations and setting changes post-purchase, as well as investigating the linkage between time and server energy efficiency.

Fuchs, Heidi (ORCID:0000000300105411)↗

A Study of Geodesic Distance Kernel on an Integrated GPU

Graphics processing units (GPUs) are commonly used for graphics and general-purpose (GPGPU) computation. Currently, NVIDIA’s GPUs, through its CUDA framework for GPGPU programming, are ubiquitous for highperformance computing. Another class of GPUs, with a central processing unit (CPU) and a GPU integrated on the same chip, is commonly used in laptops, desktop computers, and low-power servers. While they are not designed to outperform discrete GPUs due to the power, area, and thermal constrains [1], there is a need to better understand the performance of a processor with an integrated GPU for floating-point intensive applications. The study helps us better understand the characteristics of hardware and software development tools, and the benefit of offloading such applications to an integrated GPU.

97 MATHEMATICS AND COMPUTING↗

Liquid-Cooled Server Technology that Dramatically Reduces Electricity in Building-Connected Data Centers and Enables 95% Waste Heat Reuse

Today data centers in the U.S consume about 70 TWh of electricity annually. What if there was an easy way to reduce this electricity use by up to 35%? Even better, what if data centers were located in ordinary buildings without the need for expensive air conditioning and air handing systems? Better still, what if the heat energy produced by the data center's servers could be easily recovered and reused for building heating? This presentation will provide an overview of a unique and innovative form of liquid immersion cooling for data center servers developed by LiquidCool Solutions that can be easily deployed to achieve the benefits described above. As validation of the benefits, the presentation will describe testing of a small-scale version of this immersion cooling system conducted at the National Renewable Energy Laboratory. Testing demonstrated that the system was able to recover 90% to 95% of server heat energy at a temperature high enough for use by conventional building heating systems while eliminating internal server fans and using just 1% of the server power to circulate cooling fluid through the system. The concluding section of the presentation will focus on development of a roadmap for scaling-up and commercializing this innovative cooling technology. This will include proposals for how specific commercial building types could make effective use of this technology to recover and reuse server waste heat and a strategy for overcoming barriers to adoption of such a new and innovative technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Heterogeneous high throughput scientific computing with APM X-Gene and Intel Xeon Phi

Electrical power requirements will be a constraint on the future growth of Distributed High Throughput Computing (DHTC) as used by High Energy Physics. Performance-per-watt is a critical metric for the evaluation of computer architectures for cost- efficient computing. Additionally, future performance growth will come from heterogeneous, many-core, and high computing density platforms with specialized processors. In this paper, we examine the Intel Xeon Phi Many Integrated Cores (MIC) co-processor and Applied Micro X-Gene ARMv8 64-bit low-power server system-on-a-chip (SoC) solutions for scientific computing applications. As a result, we report our experience on software porting, performance and energy efficiency and evaluate the potential for use of such technologies in the context of distributed computing systems such as the Worldwide LHC Computing Grid (WLCG).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparing Server Energy Use and Efficiency Using Small Sample Sizes

This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a group is similar to all other components as a group. However, some differences were observed. The Supermicro server used 27 percent more power at idle compared to the other brands. The Intel server had a power supply control feature called cold redundancy, and the data suggest that cold redundancy can provide energy savings at low power levels. Test and evaluation methods that might be used by others having limited resources for IT equipment evaluation are explained in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-time simulator and controller of power system using distributed data streaming server

Systems and methods for simulating and controlling a power system in real time, using a controller, are provided. The controller includes a simulation layer to simulate an operation of the power system, a disturbance generation layer to provide data to the simulation layer to disturb the simulated operation of the power system, an application layer to display the simulated operation of the power system and generate a control signal to control, based on the simulated operation of the power system, at least one element of the power system, and a distributed data streaming server (D2S2) to allow interoperability among the simulation layer, the disturbance layer, and the application layer.

Li, Fangxing↗

Sustainability, Feasibility, and Economics of a Fuel Cell-Powered Data Center

Data centers, used for cloud computing or data storage, consume huge amounts of power and are increasing rapidly in number, and consequently, this increase in power consumption has raised concerns with green and sustainable energy supplies to minimize carbon emissions. Significant renewable power can be a carbon-free energy source to reduce the carbon footprint of a data center; however, direct integration of wind and solar power with data center causes concern of the power quality for uninterrupted power supply to computer servers. The reliable power supply can be accomplished by using power produced from fuel cells fueled by hydrogen. If fed with hydrogen derived from renewable sources, fuel cells will realize carbon-free data centers. This presentation shows various renewable-integration scenarios to meet reliable and sustainable power requirements for a data center.

25 ENERGY STORAGE↗

Characteristics and Energy Use of Volume Servers in the United States

Servers’ field energy use remains poorly understood, given heterogeneous computing loads, configurable hardware and software, and operation over a wide range of management practices. This paper explores various characteristics of 1- and 2-socket volume servers that affect energy consumption, and quantifies the difference in power demand between higher-performing SPEC and ENERGY STAR servers and our best understanding of a typical server operating today. We first establish general characteristics of the U.S. installed base of volume servers from existing IDC data and the literature, before presenting information on server hardware configurations from data collection events at a major online retail website. We then compare cumulative distribution functions of server idle power across three separate datasets and explain the differences between them via examination of the hardware characteristics to which power draw is most sensitive. We find that idle server power demand is significantly higher than ENERGY STAR benchmarks and the industry-released energy use documented in SPEC, and that SPEC server configurations—and likely the associated power-scaling trends—are atypical of volume servers. Next, we examine recent trends in server power draw among high-performing servers across their full load range to consider how representative these trends are of all volume servers before inputting weighted average idle power load values into a recently published model of national server energy use. Finally, we present results from two surveys of IT managers (n=216) and IT vendors (n=178) that illustrate the prevalence of more-efficient equipment and operational practices in server rooms and closets; these findings highlight opportunities to improve the energy efficiency of the U.S. server stock.

97 MATHEMATICS AND COMPUTING↗

NOODLES Grid [SWR-25-93]

NOODLES Grid is a real-time visualization server for power system simulation data. It loads precomputed datasets, builds optimized instance renderings, and streams live interactive scenes to connected clients. It is built for high scalability, flexible visualization, and fast interaction. NOODLES is a cross-platform/device/tool protocol for collaborative visualization. NOODLES was Developed at the National Renewable Energy Laboratory (NREL) as a capability of the Insight Center https://www.nrel.gov/computational-science/insight-center.html

Brunhart-Lupo, Nicholas [National Renewable Energy↗

Emerging New Strategies for Successful Metabolite Identification in Metabolomics

NMR is a very powerful tool for the identification of known and unknown (or unnamed) metabolites in complex mixtures as encountered in metabolomics. Known compounds can be reliably identified using 2D NMR methods, such as 13C-1H HSQC, for which powerful web servers with databases are available for semi-automated analysis. For the identification of unknown compounds, new combinations of NMR with MS have been developed recently that make synergistic use of the mutual strengths of the two techniques. The use of chemical additives to the NMR tube, such as reactive agents, paramagnetic ions, or charged silica nanoparticles, permit the identification of metabolites with specific physical chemical properties. In the following sections, we give an overview of some of the recent advances in metabolite identification and discuss remaining challenges.

Bingol, Ahmet K.↗

Performance analysis of Wald-statistic based network detection methods for radiation sources

There have been increasingly large deployments of radiation detection networks that require computationally fast algorithms to produce prompt results over ad-hoc sub-networks of mobile devices, such as smart-phones. These algorithms are in sharp contrast to complex network algorithms that necessitate all measurements to be sent to powerful central servers. In this work, at individual sensors, we employ Wald-statistic based detection algorithms which are computationally very fast, and are implemented as one of three Z-tests and four chi-square tests. At fusion center, we apply the K-out-of-N fusion to combine the sensors hard decisions. We characterize the performance of detection methods by deriving analytical expressions for the distributions of underlying test statistics, and by analyzing the fusion performances in terms of K, N, and the false-alarm rates of individual detectors. We experimentally validate our methods using measurements from indoor and outdoor characterization tests of the Intelligence Radiation Sensors Systems (IRSS) program. In particular, utilizing the outdoor measurements, we construct two important real-life scenarios, boundary surveillance and portal monitoring, and present the results of our algorithms.

Sen, Satyabrata↗

Differential Power Processing for Ultra-Efficient Data Storage

Here this paper presents the hardware, software, and power codesign of an ultra-efficient data storage server with differential power processing (DPP). DPP can reduce the power conversion stress, improve the efficiency, and enhance the functionality of modular power electronics systems. The power inputs of a large number of hard disk drives (HDDs) were connected in series and supported by a multiport ac-coupled differential power processing (MAC-DPP) converter through a multiwinding transformer. Methods for controlling the multi-input multi-output power flow in the multiwinding transformer while avoiding core saturation were investigated. A ten-port MAC-DPP prototype with 700-W/in 3 power density was built to support a 450-W HDD storage system with ten series-stacked voltage domains. The prototype was tested on a 50-HDD server testbench, and the overall system loss is below 1 W (99.77% system efficiency). The server was able to maintain high-speed reading and writing operation of all 50 HDDs against the worst hot-swapping scenarios. A variety of hardware/software configurations and many cloud storage techniques were tested on the fully functioning server. Experimental results show that the energy efficiency of large-scale information systems (CPU/GPU clusters, memory banks, HDD arrays, etc.) can be greatly improved by software, hardware, and power codesign.

42 ENGINEERING↗

Prototype Integrated Hydrogen Fuel Cell Powered Data Center (Cooperative Research and Development Final Report)

Data centers are the backbone of the modern economy-from the server rooms that power small- to medium-sized organizations, to the enterprise-class data centers that support American corporations, and the server farms that run cloud computing services. Rather than a traditional grid-centric data center approach, work under the CRADA will be directed towards implementing a proof-of-concept "hydrogen-based" data center utilizing hydrogen fuel cells, electrolyzers, and solar photovoltaics as key building blocks. This integrated proof-of-concept builds on preliminary work done by HPE and its partners Mercedes-Benz Research & Development North America, Inc. (MBRDNA) and Power Innovations, to dramatically simplify the electrical infrastructure in the data center, leverage the latest automotive-scale hydrogen fuel cell technologies, and tightly couple renewably generated DC power directly to the Information Technology (IT). While some limited aspects of this concept have been demonstrated previously the entire integrated proof of concept proposed here has not yet been realized.

08 HYDROGEN↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗

Guest Editorial: Special Issue on InterPACK 2019 - Part 1

This is a collection of papers drawn from the 2019 ASME InterPACK Conference. The content spans the areas of heterogeneous integration, servers, flexible and wearable electronics, photonics, power electronics, energy storage, and autonomous and electric vehicles.

47 OTHER INSTRUMENTATION↗

In-Network DAQ Functions

A revolution in networking is changing how we compute, but we lack the tools that can channel this new capability to benefit science. It is now possible to write programs that operate "in" the network—on network cards (NICs) and network switches themselves, rather than on servers. These programs can analyze and reduce huge volumes of data as they flow through the network—at higher throughput, lower latency, and lower power consumption than if servers (containing CPUs or GPUs) were used. That equipment offers appealing features for scientific experiments that involve huge quantities of data. This poster describes a prototype LArTPC raw-waveform hit finder based on DUNE’s Trigger Primitives generator. We built this as part of ongoing research to better understand how to put programmable network hardware to use in large scientific experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗