Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Cycle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved target handoff for single cycle instrument placement

Single Cycle Instrument Placement(SCIP)could dramatically increase the speed of various planetary rover operations. JPL is validating SCIP for use on its upcoming Mars Science Laboratory mission. Two major sources of error in the implementation submitted for validation were imprecision in selecting a distant target and error introduced while handing the target off to the rover's hazard cameras (hazcams). We have added the capability to designate a target using high resolution cameras (pancams) and then hand off to medium resolution cameras (navcams) with little error later in the traverse. We implemented several options for handoff from navcams to hazcams. We evaluated their performance on several test cases. Two methods produced average handoff error of 1 pixel when successful, but these only worked in half of the tests. Two other methods reliably produced about 10 pixels of error. None reliably reach the goal of 1 pixel handoff accuracy.

handoff↗

Single-Cycle Versus Multicycle Proof Testing

Report compares single-cycle with multiple-cycle mechanical-stress tests of parts under mechanical stresses. Objective of proof testing: to screen out gross manufacturing or material deficiencies and provide additional assurance of quality. Report concludes that changes in distribution of crack sizes during multicycle proof testing depend on initial distribution, number of cycles, relationship between resistance of material and elastic/plastic fracture-mechanics parameter, relationship between load control and displacement control, and magnitude of applied load or displacement. Whether single-cycle or multicycle testing used depends on shape, material, and technique of fabrication of components tested.

Hudak, S. J., Jr.↗

A comparison of single-cycle versus multiple-cycle proof testing strategies

An evaluation of single-cycle and multiple-cycle proof testing (MCPT) strategies for SSME components is described. Data for initial sizes and shapes of actual SSME hardware defects are analyzed statistically. Closed-form estimates of the J-integral for surface flaws are derived with a modified reference stress method. The results of load- and displacement-controlled stable crack growth tests on thin IN-718 plates with deep surface flaws are summarized. A J-resistance curve for the surface-cracked configuration is developed and compared with data from thick compact tension specimens. The potential for further crack growth during large unload/reload cycles is discussed, highlighting conflicting data in the literature. A simple model for ductile crack growth during MCPT based on the J-resistance curve is used to study the potential effects of key variables. The projected changes in the crack size distribution during MCPT depend on the interactions between several key parameters, including the number of proof cycles, the nature of the resistance curve, the initial crack size distribution, the component boundary conditions (load vs. displacement control), and the magnitude of the applied load or displacement. The relative advantages of single-cycle and multiple-cycle proof testing appear to be specific, therefore, to individual component geometry, material, and loading.

Hudak, S. J., Jr.↗

A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies

Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semi-elliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT vs. SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.

McClung, R. C.↗

A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies

Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semi-elliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT vs. SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.

McClung, R. C.↗

A Comparison of Single-Cycle Versus Multiple-Cycle Proof Testing Strategies

Single-cycle and multiple-cycle proof testing (SCPT and MCPT) strategies for reusable aerospace propulsion system components are critically evaluated and compared from a rigorous elastic-plastic fracture mechanics perspective. Earlier MCPT studies are briefly reviewed. New J-integral estimation methods for semielliptical surface cracks and cracks at notches are derived and validated. Engineering methods are developed to characterize crack growth rates during elastic-plastic fatigue crack growth (FCG) and the tear-fatigue interaction near instability. Surface crack growth experiments are conducted with Inconel 718 to characterize tearing resistance, FCG under small-scale yielding and elastic-plastic conditions, and crack growth during simulated MCPT. Fractography and acoustic emission studies provide additional insight. The relative merits of SCPT and MCPT are directly compared using a probabilistic analysis linked with an elastic-plastic crack growth computer code. The conditional probability of failure in service is computed for a population of components that have survived a previous proof test, based on an assumed distribution of initial crack depths. Parameter studies investigate the influence of proof factor, tearing resistance, crack shape, initial crack depth distribution, and notches on the MCPT versus SCPT comparison. The parameter studies provide a rational basis to formulate conclusions about the relative advantages and disadvantages of SCPT and MCPT. Practical engineering guidelines are proposed to help select the optimum proof test protocol in a given application.

McClung, R. C.↗

Complete Initial Evaluation of Novel Complexants for Tc Holdback for Simplified Single Cycle Separations.

Management of technetium at the back end of nuclear fuel cycle is complicated by its unique physico-chemical character, but must be addressed to due to the environmental, storage and reprocessing challenges of this fission product. In a single-cycle scenario, the recovery and purification of uranium is particularly challenging due to the tendency of a pertechnetate anion to follow uranyl cation. This report summarizes initial studies directed towards finding the solution for technetium management. Two options for controlling technetium’s chemistry in solvent extraction scenarios were studied. Molecular recognition of pertechnetate by aqueous complexants based on guanidinium moieties was compared to redox manipulation of technetium using dihydrazide reagents. Solvent extraction, potentiometric and nuclear magnetic resonance spectroscopy studies were performed. The influence of guanidinium reagents on the liquid-liquid partitioning of technetium is less pronounced, relative to dihydrazides. Strong impact exerted by dihydrazides originates from the technetium-catalyzed decomposition of such compounds which reduces technetium to a tetravalent, non-extractable state. Although this route of technetium management is very effective the destruction of dihydrazides is undesirable. Guanidinium complexants show a more tempered influence on technetium. The effect on the liquid-liquid partitioning of pertechnetate is evident and likely guided by anion recognition due to ion-pair and hydrogen bond formation. Guanidiniums are stable in presence of technetium as evidenced by nuclear magnetic resonance studies. The steady state chemistry of guanidiniums identify this class of aqueous complexants as solid candidates for structure-function pertechnetate recognition studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiolytic transformation of AHA under single-cycle conditions

Historically, the radiation robustness of extractant ligands and the impact of their radiolysis products have been used to evaluate the radiolytic feasibility of solvent system formulations for used nuclear fuel (UNF) reprocessing. However, other key additives (e.g., reducing and hold-back reagents) are employed by these solvent systems. These chemical species have typically been overlooked from a radiolytic perspective, and consequently little is known on how they impact process performance. Therefore, to holistically support the development of advanced, simplified, single-cycle flowsheets for UNF reprocessing, the radiation robustness of two key proposed additives – (i) the complexing reductant acetohydroxamic acid (AHA) and (ii) the hold-back reagent 1,2-cyclohexylenedinitrilotetraacetic acid (CDTA) – have been evaluated under envisioned process conditions using a combination of steady-state gamma and time-resolved pulsed electron irradiation techniques.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A comparison of single-cycle versus multi-cycle proof testing strategies

Proof testing was a useful supplement to conventional nondestructive evaluation (NDE) of space shuttle main engine (SSME) components. Since many of these components involve thin sections and high toughness materials, such as Inconel 718, conventional single-cycle proof test logic is not applicable due to the propensity for stable crack growth during the proof tests. Experience with five-cycle proof testing of SSME components is summarized and a framework is outlined for understanding multi-cycle proof testing using the fracture mechanics concept of a resistance curve. Extreme value statistics are also used to propose an empirical approach to compare the advantages and disadvantages of single- versus multi-cycle proof testing. The importance of the initial flaw size distribution and specimen thickness in such a comparison is also discussed.

Hudak, Stephen J., Jr.↗

Time-refraction optics with single cycle modulation

Abstract We present an experimental study of optical time-refraction caused by time-interfaces as short as a single optical cycle. Specifically, we study the propagation of a probe pulse through a sample undergoing a large refractive index change induced by an intense modulator pulse. In these systems, increasing the refractive index abruptly leads to time-refraction where the spectrum of all the waves propagating in the medium is red-shifted, and subsequently blue-shifted when the refractive index relaxes back to its original value. We observe these phenomena in the single-cycle regime. Moreover, by shortening the temporal width of the modulator to ∼5–6 fs, we observe that the rise time of the red-shift associated with time-refraction is proportionally shorter. The experiments are carried out in transparent conducting oxides acting as epsilon-near-zero materials. These observations raise multiple questions on the fundamental physics occurring within such ultrashort time frames, and open the way for experimenting with photonic time-crystals, generated by periodic ultrafast changes to the refractive index, in the near future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CMOS-Based Single-Cycle in-Memory XOR/XNOR

Big data applications are on the rise, and so is the number of data centers. The ever-increasing massive data pool needs to be periodically backed up in a secure environment. Moreover, a massive amount of securely backed-up data is required for training binary convolutional neural networks for image classification. XOR and XNOR operations are essential for large-scale data copy verification, encryption, and classification algorithms. The disproportionate speed of existing compute and memory units makes the von Neumann architecture inefficient to perform these Boolean operations. Compute-in-memory (CiM) has proved to be an optimum approach for such bulk computations. The existing CiM-based XOR/XNOR techniques either require multiple cycles for computing or add to the complexity of the fabrication process. Here, we propose a CMOS-based hardware topology for single-cycle in-memory XOR/XNOR operations. Our design provides at least 2× improvement in the latency compared with other existing CMOS-compatible solutions. We verify the proposed system through circuit/system-level simulations and evaluate its robustness using a 5000-point Monte Carlo variation analysis. This all-CMOS design paves the way for practical implementation of CiM XOR/XNOR at scaled technology nodes.

97 MATHEMATICS AND COMPUTING↗

Multi-millijoule hollow-core fiber compression of short-wave infrared pulses to a single cycle

Approaches for efficient pulse compression can enable dramatic increases in the available peak power, as well as enable the generation of isolated attosecond X-ray pulses. Achieving high compression ratios for longer wavelength drivers has, however, been challenging. We present the compression of few-cycle 2.1 µm central wavelength short-wave infrared laser pulses to 6.9 fs with 2.35 mJ pulse energy at a 10 kHz repetition rate. Electric field resolved measurements reveal a single cycle light field oscillation. With a carrier-envelope-phase stability of 131 mrad and average power fluctuations below 1 %, the system constitutes an excellent light source for strong-field experiments and attosecond physics.

Blöchl, Johannes [Ludwig Maximilian Univ. of Munic↗

Ultrafast bipolar conductivity driven by intense single-cycle terahertz pulses in a topological insulator Bi 2 Se 3

We present the measurement of ultrafast terahertz (THz) conductivity of a 50 nm thick topological insulator Bi 2 Se 3 at low temperature 5 K by using a THz pump and THz probe spectroscopy scheme. Here, the THz conductivity driven by a single-cycle intense THz pump exhibits a bipolar lineshape and frequency-dependent relaxation dynamics due to the separated surface and bulk charge carriers with distinctly different scattering rates and relaxation times. We also demonstrate THz pump field-dependent excitation of the surface and bulk spectral weights, which suggests one of the optimal THz excitation conditions for generating the most charge carriers from the topology-protected surface state relative to the bulk. This also allows THz control of surface and bulk transport channels in a selective way.

36 MATERIALS SCIENCE↗

Long-wavelength-infrared laser filamentation in solids in the near-single-cycle regime

We experimentally demonstrate long-wavelength-infrared (LWIR) femtosecond filamentation in solids. Systematic investigations of supercontinuum (SC) generation and self-compression of the LWIR pulses assisted by laser filamentation are performed in bulk KrS-5 and ZnSe, pumped by ∼ <#comment/> 145 f s , 9 µm, 10 µJ pulses from an optical parametric chirped-pulse amplifier operating at 10 kHz of repetition rate. Multi-octave SC spectra are demonstrated in both materials. While forming stable single filament, 1.5 cycle LWIR pulses with 4.5 µJ output pulse energy are produced via soliton-like self-compression in a 5 mm thick KrS-5. The experimental results quantitatively agree well with the numerical simulation based on the unidirectional pulse propagation equation. This work shows the experimental feasibility of high-energy, near-single-cycle LWIR light bullet generation in solids.

Qu, Shizhen↗

Terrain Model Registration for Single Cycle Instrument Placement

This paper presents an efficient and robust method for registration of terrain models created using stereo vision on a planetary rover. Our approach projects two surface models into a virtual depth map, rendering the models as they would be seen from a single range sensor. Correspondence is established based on which points project to the same location in the virtual range sensor. A robust norm of the deviations in observed depth is used as the objective function, and the algorithm searches for the rigid transformation which minimizes the norm. An initial coarse search is done using rover pose information from odometry and orientation sensing. A fine search is done using Levenberg-Marquardt. Our method enables a planetary rover to keep track of designated science targets as it moves, and to hand off targets from one set of stereo cameras to another. These capabilities are essential for the rover to autonomously approach a science target and place an instrument in contact in a single command cycle.

Deans, Matthew↗