Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Ion Conducting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Norbornene-Based Polymer Electrolytes for Lithium Cells

Norbornene-based polymers have shown promise as solid electrolytes for lithium-based rechargeable electrochemical cells. These polymers are characterized as single-ion conductors. Single-ion-conducting polymers that can be used in lithium cells have long been sought. Single-ion conductors are preferred to multiple-ion conductors as solid electrolytes because concentration gradients associated with multiple-ion conduction lead to concentration polarization. By minimizing concentration polarization, one can enhance charge and discharge rates. Norbornene sulfonic acid esters have been synthesized by a ring-opening metathesis polymerization technique, using ruthenium-based catalysts. The resulting polymer structures (see figure) include sulfonate ionomers attached to the backbones of the polymer molecules. These molecules are single-ion conductors in that they conduct mobile Li+ ions only; the SO3 anions in these polymers, being tethered to the backbones, do not contribute to ionic conduction. This molecular system is especially attractive in that it is highly amenable to modification through functionalization of the backbone or copolymerization with various monomers. Polymers of this type have been blended with poly(ethylene oxide) to lend mechanical integrity to free-standing films, and the films have been fabricated into solid polymer electrolytes. These electrolytes have been demonstrated to exhibit conductivity of 2 10(exp -5)S/cm (which is high, relative to the conductivities of other solid electrolytes) at ambient temperature, plus acceptably high stability. This type of norbornene-based polymeric solid electrolyte is in the early stages of development. Inasmuch as the method of synthesis of these polymers is inherently flexible and techniques for the fabrication of the polymers into solid electrolytes are amenable to optimization, there is reason to anticipate further improvements.

Cheung, Iris↗

A Synopsis of Interfacial Phenomena in Lithium-Based Polymer Electrolyte Electrochemical Cells

The interfacial regions between electrode materials, electrolytes and other cell components play key roles in the overall performance of lithium-based batteries. For cell chemistries employing lithium metal, lithium alloy or carbonaceous materials (i.e., lithium-ion cells) as anode materials, a "solid electrolyte interphase" (SEI) layer forms at the anode/electrolyte interface, and the properties of this "passivating" layer significantly affect the practical cell/battery quality and performance. A thin, ionically-conducting SEI on the electrode surface can beneficially reduce or eliminate undesirable side reactions between the electrode and the electrolyte, which can result in a degradation in cell performance. The properties and phenomena attributable to the interfacial regions existing at both anode and cathode surfaces can be characterized to a large extent by electrochemical impedance spectroscopy (EIS) and related techniques. The intention of the review herewith is to support the future development of lithium-based polymer electrolytes by providing a synopsis of interfacial phenomena that is associated with cell chemistries employing either lithium metal or carbonaceous "composite" electrode structures which are interfaced with polymer electrolytes (i.e., "solvent-free" as well as "plasticized" polymer-binary salt complexes and single ion-conducting polyelectrolytes). Potential approaches to overcoming poor cell performance attributable to interfacial effects are discussed.

Baldwin, Richard S.↗

Fundamental processes in the expansion, energization, and coupling of single- and multi-Ion plasmas in space: Laboratory simulation experiments

We have conducted a laboratory investigation into the physics of plasma expansions and their associated energization processes. We studied single- and multi-ion plasma processes in self-expansions, and included light and heavy ions and heavy/light mixtures to encompass the phenomenological regimes of the solar and polar winds and the AMPTE and CRRES chemical release programs. The laboratory experiments provided spatially-distributed time-dependent measurements of total plasma density, temperature, and density fluctuation power spectra with the data confirming the long-theorized electron energization process in an expanding cloud - a result that was impossible to determine in spaceborne experiments (as e.g., in the CRRES program). These results provided the missing link in previous laboratory and spaceborne programs. confirming important elements in our understanding of such solar-terrestrial processes as manifested in expanding plasmas in the solar wind (e.g., CMES) and in ionospheric outflow in plasmaspheric fluctuate refilling after a storm. The energization signatures were seen in an entire series of runs that varied the ion species (Ar', Xe', Kr' and Ne'), and correlative studies included spectral analyses of electrostatic waves collocated with the energized electron distributions. In all cases wave energies were most intense during the times in which the suprathermal populations were present, with wave intensity increasing with the intensity of the suprathermal electron population. This is consistent with theoretical expectations wherein the energization process is directly attributable to wave particle interactions. No resonance conditions were observed, in an overall framework in which the general wave characteristics were broadband with power decreasing with increasing frequency.

Szuszczewicz, E. P.↗

Single-Event Effect Testing of the Vishay Si7414DN n-Type TrenchFET(Registered Trademark) Power MOSFET

This study was being undertaken to determine the single event effect susceptibility of the commercial Vishay 60-V TrenchFET power MOSFET. Heavy-ion testing was conducted at the Texas AM University Cyclotron Single Event Effects Test Facility (TAMU) and the Lawrence Berkeley National Laboratory BASE Cyclotron Facility (LBNL). In addition, initial 200-MeV proton testing was conducted at Massachusetts General Hospital (MGH) Francis H. Burr Proton Beam Therapy Center. Testing was performed to evaluate this device for single-event effects from lower-LET, lighter ions relevant to higher risk tolerant space missions.

proton testing↗

Free-Energy Calculations. A Mathematical Perspective

Ion channels are pore-forming assemblies of transmembrane proteins that mediate and regulate ion transport through cell walls. They are ubiquitous to all life forms. In humans and other higher organisms they play the central role in conducting nerve impulses. They are also essential to cardiac processes, muscle contraction and epithelial transport. Ion channels from lower organisms can act as toxins or antimicrobial agents, and in a number of cases are involved in infectious diseases. Because of their important and diverse biological functions they are frequent targets of drug action. Also, simple natural or synthetic channels find numerous applications in biotechnology. For these reasons, studies of ion channels are at the forefront of biophysics, structural biology and cellular biology. In the last decade, the increased availability of X-ray structures has greatly advanced our understanding of ion channels. However, their mechanism of action remains elusive. This is because, in order to assist controlled ion transport, ion channels are dynamic by nature, but X-ray crystallography captures the channel in a single, sometimes non-native state. To explain how ion channels work, X-ray structures have to be supplemented with dynamic information. In principle, molecular dynamics (MD) simulations can aid in providing this information, as this is precisely what MD has been designed to do. However, MD simulations suffer from their own problems, such as inability to access sufficiently long time scales or limited accuracy of force fields. To assess the reliability of MD simulations it is only natural to turn to the main function of channels - conducting ions - and compare calculated ionic conductance with electrophysiological data, mainly single channel recordings, obtained under similar conditions. If this comparison is satisfactory it would greatly increase our confidence that both the structures and our computational methodologies are sufficiently accurate. Channel conductance, defined as the ratio of ionic current through the channel to applied voltage, can be calculated in MD simulations by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. If the current is small, a voltage significantly higher than the experimental one needs to be applied to collect sufficient statistics of ion crossing events. Then, the calculated conductance has to be extrapolated to the experimental voltage using procedures of unknown accuracy. Instead, we propose an alternative approach that applies if ion transport through channels can be described with sufficient accuracy by the one-dimensional diffusion equation in the potential given by the free energy profile and applied voltage. Then, it is possible to test the assumptions of the equation, recover the full voltage/current dependence, determine the reliability of the calculated conductance and reconstruct the underlying (equilibrium) free energy profile, all from MD simulations at a single voltage. We will present the underlying theory, model calculations that test this theory and simulations on ion conductance through a channel that has been extensively studied experimentally. To our knowledge this is the first case in which the complete, experimentally measured dependence of the current on applied voltage has been reconstructed from MD simulations.

free energy↗

Cardiovascular Responses to Simulated Spaceflight: Molecular Signatures and Surrogate Outputs to Measure CVD Risk

During extended space missions beyond low Earth orbit, astronauts will encounter prolonged periods of weightlessness and low dose space radiation. Previous studies have shown that exposure to small doses of high LET radiation (< 50 cGy) can lead to both short-term and long-term alterations in heart function, structure and underlying molecular mechanisms. In this study, we aim to identify the molecular signature associated with the cardiovascular response to simulated galactic cosmic radiation (5-ion GCR) alone or in combination with simulated weightlessness at time intervals relevant to mission length and recovery. Additionally, we aim to determine whether sex impacts cardiovascular responses to these spaceflight factors. Our overarching goal is to enhance our understanding of the cardiovascular risks associated with extended space missions and the clinical endpoints they suggest. We hypothesize that exposure to simulated space radiation leads to enduring alterations in the transcriptome, redox signaling and cytokine environment of cardiovascular tissue, some which have known links with reduced cardiovascular performance, aging, and increased risk of cardiovascular disease (CVD). Furthermore, we posit that simulated space radiation exposure in combination with simulated microgravity exacerbates cardiovascular deficits compared to single factor exposure. Female and male C57BL/6J mice, aged 23-24 weeks, were exposed to a single dose of 5, 15, or 50 cGy of 5-ion GCR, or sham-treated (0 cGy). Euthanasia was performed at 14 days and ~4 months post-irradiation. Hearts, aorta and blood plasma were collected shortly thereafter. RNA-sequencing of left ventricles at ~4 months post-GCR exposure revealed sex differences in the heart transcriptome with a few genes showing radiation-dependent changes in expression levels. Notably, some of the differentially expressed genes in 15 and 50 cGy GCR groups are known to play roles in the development of CVD. Analysis of protein levels of a subset of inflammatory cytokines in the heart indicated sex differences but no differences between sham and 50 cGy groups. Results also showed correlations among differentially expressed genes and a subset of inflammatory cytokines, with some correlations altered by GCR exposure. These findings suggest that GCR exposure can modify protein and gene networks linked to inflammation and CVD progression. In the aorta, telomere lengths were comparable across treatment groups sexes. Mitochondrial copy number is a biomarker for mitochondrial function with decreased copy numbers associated with cardiometabolic disease traits. Mitochondrial copy numbers of aorta also showed no sex nor dose differences. In a second study, mice underwent one week of simulated microgravity by hindlimb unloading (HU) and then exposed to a single dose of 15 cGy of 5-ion GCR. HU was conducted for an additional two weeks following GCR exposure. Single factor exposure groups (HU or GCR only) also were included in the study. Euthanasia was then performed and the same tissues were collected. Protein levels of select inflammatory cytokines in the heart showed sex-dependent differences in expression. In the aorta, telomere lengths and mitochondrial copy number also showed sex differences. In summary, our results indicate differences between sexes in biomarkers related to cardiovascular health. Exposure to 5-ion GCR or HU, alone or in combination, did not result in changes in most of the cardiovascular biomarkers that were examined. However, in the heart, simulated space radiation at doses of 15 and 50 cGy led to long-term alterations in the expression levels of a small group of genes known to be associated with the progression of CVD. The long-term transcriptomic changes resulting from exposure to simulated space radiation should be carefully investigated to mitigate adverse cardiovascular events during and after deep space missions. Our results also highlight the importance of sex-specific strategies in monitoring and maintaining cardiovascular health during and after deep space missions.

cardiovascular↗

Single-Event Effect Performance of a Conductive-Bridge Memory EEPROM

We investigated the heavy ion SEE characteristics of an EEPROM based on CBRAM technology. SEFI is the dominant type of SEE for each operating mode (standby, read-only, write/read). We also observed single bit upsets in the CBRAM cell, during write/read tests. the SEULET threshold is between 10 and 20 MeV * sq cm/mg, with an upper fluence limit of 3 × 10(exp 6) cm(exp -2) at 10 MeV * sq cm/mg. In the stand by mode, the CBRAM array appears immune to bit upsets.

single event effects↗

Single-Event Effect Testing of the Cree C4D40120D Commercial 1200V Silicon Carbide Schottky Diode

This study was undertaken to determine the single event effect (SEE) susceptibility of the commercial silicon carbide 1200V Schottky diode manufactured by Cree, Inc. Heavy-ion testing was conducted at the Texas A&M University Cyclotron Single Event Effects Test Facility (TAMU). Its purpose was to evaluate this device as a candidate for use in the Solar-Electric Propulsion flight project.

silicon carbide (SiC)↗

Two-temperature models of old supernova remnants with ion and electron thermal conduction

To investigate the potential effects thermal conduction may have on the evolution of old supernova remnants, we present the results of 1D (spherically symmetric) numerical simulations of a remnant in a homogeneous interstellar medium for four different cases: (1) without thermal conduction; (2) with both electron and ion thermal conduction assuming equal temperatures; (3) with electron thermal conduction only, following electron and ion temperatures separately; and (4) with both electron and ion thermal conduction following separate temperatures. We followed the entire evolution until the completion of the remnant bubble collapse. Our most significant result is that in remnant evolution studies concerned principally with either the shell or bubble evolution at late times, reasonable results are obtained with single-temperature models. When the electron and ion temperatures are followed separately, however, ion thermal conduction cannot safely be ignored.

Cui, Wei↗

Single event upset susceptibility testing of the Xilinx Virtex II FPGA

Heavy ion testing of the Xilinx Virtex IZ was conducted on the configuration, block RAM and user flip flop cells to determine their single event upset susceptibility using LETs of 1.2 to 60 MeVcm^2/mg. A software program specifically designed to count errors in the FPGA is used to reveal L1/e values and single-event-functional interrupt failures.

FPGA Xilinx Virtex static test single event upset↗

Single event upset suspectibility testing of the Xilinx Virtex II FPGA

Heavy ion testing of the Xilinx Virtex II was conducted on the configuration, block RAM and user flip flop cells to determine their static single-event upset susceptibility using LETs of 1.2 to 60 MeVcm^2/mg. A software program specifically designed to count errors in the FPGA was used to reveal L1/e, values (the LET at which the cross section is l/e times the saturation cross-section) and single-event functional-interrupt failures.

FPGA Virtex II SEU↗

Nanopipette Apparatus for Manipulating Cells

Disclosed herein are methods and systems for controlled ejection of desired material onto surfaces including in single cells using nanopipettes, as well as ejection onto and into cells. Some embodiments are directed to a method and system comprising nanopipettes combined with an xyz controller for depositing a user defined pattern on an arbitrary substrate for the purpose of controlled cell adhesion and growth. Alternate embodiments are directed to a method and system comprising nanopipettes combined with an xyz controller and electronic control of a voltage differential in a bore of the nanopipette electroosmotically injecting material into a cell in a high-throughput manner and with minimal damage to the cell. Yet other embodiments are directed to method and system comprising functionalized nanopipettes combined with scanning ion conductance microscopy for studying molecular interactions and detection of biomolecules inside a single living cell.

Seger, R. Adam↗

Destiny of earthward streaming plasma in the plasmasheet boundary layer

The dynamics of the earth's magnetotail have been investigated, and it has become clear that the plasmasheet boundary layer field lines map into the Region I Field-Aligned Currents (FAC) of the auroral zone. It is pointed out that the role of earthward streaming ions in the plasmasheet boundary layer may be of fundamental importance in the understanding of magnetotail dynamics, auroral zone physics, and especially for ionospheric-magnetospheric interactions. The present paper has the objective to evaluate propagation characteristics for the earthward streaming ions observed in the plasmasheet boundary layer. An investigation is conducted of the propagation characteristics of protons in the plasmasheet boundary layer using independent single particle dynamics, and conclusions are discussed. The density of earthward streaming ions found in the plasmasheet boundary layer should include the ring current as well as the auroral zone precipitaiton and inner plasmasheet regions of the magnetosphere.

Green, J. L.↗

Single-Event Effect Testing of the ON Semiconductor BSS123 N-Channel Logic Level Enhancement Mode FET and the Vishay Si1013R P-Channel MOSFET

This study was undertaken to determine the single event effect (SEE) susceptibility of two different MOSFET components. Heavy-ion testing was conducted at the Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Space Effects (BASE) Facility 88” Cyclotron. Its purpose was to evaluate these devices as candidates for use on Goddard Modular SmallSat Architecture (GMSA) adapter board for the GTOSat project.

Michael J Campola↗

Molecular Dynamics Simulation of the Antiamoebin Ion Channel: Linking Structure and Conductance

Molecular dynamics simulations were carried out in order to ascertain which of the potential multimeric forms of the transmembrane peptaibol channel, antiamoebin, is consistant with its measured conductance. Estimates of the conductance obtained through counting ions that cross the channel and by solving the Nernst-Planck equation yield consistent results, indicating that the motion of ions inside the channel can be satisfactorily described as diffusive.The calculated conductance of octameric channels is markedly higher than the conductance measured in single channel recordings, whereas the tetramer appears to be non-conducting. The conductance of the hexamer was estimated to be 115+/-34 pS and 74+/-20 pS, at 150 mV and 75 mV, respectively, in satisfactory agreement with the value of 90 pS measured at 75 mV. On this basis we propose that the antiamoebin channel consists of six monomers. Its pore is large enough to accommodate K(+) and Cl(-) with their first solvation shells intact. The free energy barrier encountered by K(+) is only 2.2 kcal/mol whereas Cl(-) encounters a substantially higher barrier of nearly 5 kcal/mol. This difference makes the channel selective for cations. Ion crossing events are shown to be uncorrelated and follow Poisson statistics. keywords: ion channels, peptaibols, channel conductance, molecular dynamics

Wilson, Michael A.↗

Destructive Single-Event Effects in Diodes

In this work, we discuss the observed single-event effects in a variety of types of diodes. In addition, we conduct failure analysis on several Schottky diodes that were heavy-ion irradiated. High- and low-magnitude optical microscope images, infrared camera images, and scanning electron microscope images are used to identify and describe the failure locations.

single event effects (SEE); Schottky diode; heavy ↗