Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Pilot Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Physics basis for the reference flat-top plasma scenario in the ST–E1 fusion power plant

As part of the U.S. Department of Energy’s Milestone-Based Fusion Energy Development Program, Tokamak Energy has completed the pre-concept design of the ST–E1 fusion power plant. ST–E1 is envisaged to operate in two phases: a pilot plant phase, targeting sustained net power production of 300 - 500 MWe for a duration >1 hr, followed by a commercial power plant phase targeting steady-state operations and a normalised overnight capital cost of ⩽12 000 $\$$/kWe. The design process adopted was highly iterative, integrating all major plant systems and progressing in a phased fidelity approach. At the pre-conceptual stage, the emphasis has been on exploring the design space, identifying the main system-level trade-offs, and making the key decisions that define the overall plant concept, rather than optimising a single operating point. This paper, part of a focused collection detailing the ST–E1 pre-concept design, addresses the development of a series of reference flat-top plasma operating points for the pilot plant phase. A modelling workflow was established to develop and assess candidate plasma design points and explore key dependencies. The workflow includes integrated core plasma modelling, magnetohydrodynamic (MHD) stability assessment, equilibrium generation, scrape-off-layer and exhaust modelling, heating & current drive design and optimisation, and turbulent transport modelling. Using this framework, the impact of several key parameters on the flat-top operating space was investigated, including the density limit, core radiation fraction and divertor power loading, level of external heating and curent drive power and assumed pedestal characteristics. The MHD stability, controllability and micro-stability characteristics of these plasmas were also analysed. These investigations informed the definition of a set of fully non-inductive, flat-top reference operating points that satisfy the high-level ST–E1 mission, including a low and high density case, a case that is stable to resistive wall modes and a case with reduced divertor power loading.

ST–E1↗

Pilot testing of CO2 capture from a coal-fired power plant—Part 2: Results from 1-MWe pilot tests

Abstract Using a 1-MWe slipstream pilot plant, solid-sorbent-based post-combustion CO2 capture was tested at a coal-fired power plant. Results from pilot testing were used to develop a preliminary full-scale commercial design. The sorbent selected for pilot-scale evaluation during this project consisted of an ion-exchange resin that incorporated amines covalently bonded to the substrate. A unique temperature-swing-absorption (TSA) process was developed that incorporated a three-stage fluidized-bed adsorber integrated with a single-stage fluidized-bed regenerator. Overall, following start-up and commissioning challenges that are often associated with first-of-a-kind pilots, the pilot plant operated as designed and expected, with a few key exceptions. The two primary exceptions were associated with: (i) handling characteristics of the sorbent, which were sufficiently different at operating temperature than at ambient temperature when design specifications were established with lab-scale testing; and (ii) CO2 adsorption in the transport line between the regenerator and adsorber that preloaded the sorbent with CO2 prior to entering the adsorber. Results from the pilot programme demonstrate that solid-sorbent-based post-combustion capture can be utilized to achieve 90% CO2 capture from coal-fired power plants.

Sjostrom, Sharon↗

Search for Double Beta Decays of Xe134 with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% ^{136}Xe and 19.098% ^{134}Xe. The detector operated at the Waste Isolation Pilot Plant between 2010 and 2018 and was designed to search for double beta decay of ^{136}Xe. Data were acquired in two phases separated by a period of detector upgrades. We report on the search for 0νββ and 2νββ decay of ^{134}Xe with Phase II EXO-200 data, with median 90% CL exclusion sensitivity to half-life T_{1/2}^{0ν}≥3.7×10^{23} yr and T_{1/2}^{2ν}≥2.6×10^{21} yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of ^{134}Xe of T_{1/2}^{0ν}≥8.7×10^{23} (90% CL) and the second strongest constraint on the two-neutrino decay of T_{1/2}^{2ν}≥2.9×10^{21} (90% CL), a threefold improvement over the EXO-200 Phase I measurement. New constraints are also set for the 2νββ and 0νββ decays of ^{134}Xe to the lowest excited state of ^{134}Ba.

Al Kharusi, S↗

Optimizing the Operational Parameters of an Electrochemical Purification Cell for Corrosion Mitigation in CSP Plants During Operation: Preprint

To make concentrating solar power (CSP) cost-competitive, the next generation of CSP plants will increase efficiency by operating at a higher temperature, which will require a new thermal energy storage material. One option for the thermal energy storage material is a ternary chloride salt that is stable at the temperatures required, but reacts easily with the atmosphere to form MgOHCl, a corrosive impurity. If left unchecked, this impurity will corrode the containment alloys, potentially leading to dangerous spills. We are working to design an electrochemical purification cell to remove MgOHCl from the molten chloride salt during CSP plant operation. In this paper, we use predictive modeling to assess the rate at which purification must occur. Additionally, we analyze possible process flow pathways for the molten chloride salts. Ultimately, we determine that implementation of a single reactor through which all chloride salts flow is the most efficient design to reduce impurity concentration below 0.1 mol % impurity.

concentrating solar power↗

Pilot microbial electrolysis cell closes the hydrogen loop for hydrothermal wet waste conversion to jet fuel

The global shift toward net-zero emissions necessitates resource recovery from wet waste. In this study, we demonstrate the first feasibility of combining pilot-scale microbial electrolytic cells (MECs) with hydrothermal liquefaction (HTL) for simultaneous post-hydrothermal liquefaction wastewater (PHW) treatment and efficient hydrogen (H₂) production to meet biocrude upgrading requirements. Long-term single reactor operation revealed that fixed anode potential enabled rapid startup, and low catholyte pH and high salinity were effective in suppression of cathodic methanogenesis and acetogenesis – resulting in high current density of 16.6 A m –2 and 9.3 A m –2 when feeding synthetic wastewater and PHW respectively. Additionally, the anode biofilm exhibited spatial variations in response to local environmental conditions. In conclusion, onsite parallel or serial operations of multiple MECs showed good performance using actual PHW with a record-high H 2 production rate of 0.5 L L R day –1 for MEC over 10 liters scale, and the optimal chemical oxygen demand (COD)-to-H 2 yield reached 0.127 kg-H 2 per kg-COD, supporting a self-sufficient, closed-loop upgrade to jet fuel.

08 HYDROGEN↗

Understanding the interplay between pilot fuel mixing and auto-ignition chemistry in hydrogen-enriched environment

The diesel-piloted dual-fuel compression ignition combustion strategy is well-suited to accelerate the decarbonization of transportation by adopting hydrogen as a renewable energy carrier into the existing internal combustion engine with minimal engine modifications. Despite the simplicity of engine modification, many questions remain unanswered regarding the optimal pilot injection strategy for reliable ignition with minimum pilot fuel consumption. The present study uses a single-cylinder heavy-duty optical engine to explore the phenomenology and underlying mechanisms governing the pilot fuel ignition and the subsequent combustion of a premixed hydrogen-air charge. The engine is operated in a dual-fuel mode with hydrogen premixed into the engine intake charge with a direct pilot injection of n-heptane as a diesel pilot fuel surrogate. Optical diagnostics used to visualize in-cylinder combustion phenomena include high-speed IR imaging of the pilot fuel spray evolution as well as high-speed HCHO* and OH* chemiluminescence as indicators of low-temperature and high-temperature heat release, respectively. Three pilot injection strategies are compared to explore the effects of pilot fuel mass, injection pressure, and injection duration on the probability and repeatability of successful ignition. The thermodynamic and imaging data analysis supported by zero-dimensional chemical kinetics simulations revealed a complex interplay between the physical and chemical processes governing the pilot fuel ignition process in a hydrogen containing charge. Hydrogen strongly inhibits the ignition of pilot fuel mixtures and therefore requires longer injection duration to create zones with sufficiently high pilot fuel concentration for successful ignition. Results show that ignition typically tends to rely on stochastic pockets with high pilot fuel concentration, which results in poor repeatability of combustion and frequent misfiring. In conclusion, this work has improved the understanding on how the unique chemical properties of hydrogen pose a challenge for maximization of hydrogen’s energy share in hydrogen dual-fuel engines and highlights a potential mitigation pathway.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling the impact of the fuel injection strategy on the combustion and performance characteristics of a heavy-duty GCI engine

Gasoline compression ignition (GCI) is a promising strategy to achieve high thermal efficiency and low emissions with limited modifications to the conventional diesel engine hardware. It is a partially premixed concept, which derives its superiority from higher volatility and longer ignition delay of gasoline-like fuels combined with higher compression ratio typical of diesel engines. Here, the present study investigates the combustion process in a GCI engine operating with different injection strategies using computational fluid dynamics (CFD). Simulations are carried out on a single cylinder of a multi cylinder heavy-duty compression ignition engine, which operates at a compression ratio of 17:1 and an engine speed of 1038 rev/min. Two different injection strategies viz., late injection (LI), and early pilot injection (EP) are investigated to understand their impact on combustion and performance of the engine. Renormalized group (RNG) k-ε model is used to describe in-cylinder turbulence and KH RT model is used to simulate the fuel spray breakup. The developed CFD methodology is validated against relevant experimental data under a wide range of operating conditions for each injection strategy. The developed CFD methodology was found to capture the engine combustion behavior quite well. Based on the validated CFD model, the differences in the progress of combustion event for the two injection strategies is highlighted. It was found that a larger pilot fuel mass fraction results in a steeper rise in the initial heat release rate which in turn influences the transition to mixing controlled combustion. In line with the experimental data, the study showed that the late pilot injection strategy with three injection pulses, results in higher performance compared to the other conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Mass of a weakly measured photon

Bohmian mechanics has garnered significant attention as an interpretation of quantum theory since the paradigmatic experiments which inferred the average trajectories of photons in the nonrelativistic regime. These experiments were largely motivated by Wiseman's formulation of Bohmian mechanics, which grounded these trajectories in weak measurements. Recently, Wiseman's framework was extended to the relativistic regime by expressing the velocity field of single photons in terms of weak values of the photon energy and momentum. Here, we propose an operational, weak value-based definition for the Bohmian “local mass” of relativistic single particles. For relativistic wave functions satisfying the scalar Klein-Gordon equation, this mass coincides with the effective mass defined by de Broglie in his relativistic pilot-wave theory, a quantity closely connected with the quantum potential that is responsible for Bohmian trajectory self-bending and the anomalous photoelectric effect. Here, we demonstrate the relationship between the photon trajectories and the mass in an interferometric setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of operational strategies for rich gas enhanced oil recovery based on a pilot test in the Bakken tight oil reservoir

Horizontal well drilling and multistage hydraulic fracturing have been demonstrated as effective approaches for stimulating oil production in the Bakken tight oil reservoir. However, after multiple years of production, primary oil recovery in the Bakken is generally less than 10% of the estimated original oil in place. Gas huff ‘n’ puff (HnP) has been tested in the Bakken Formation as an enhanced oil recovery (EOR) method; however, most field pilot test results showed no significant incremental oil production. One of the factors affecting HnP EOR performance is premature gas breakthrough, which is one of the most critical issues observed in the field because of the presence of interwell fractures. Consequently, injected gas rapidly reaches adjacent production wells without contacting reservoir rock and increasing oil recovery. Proper conformance control is therefore needed to avoid early gas breakthrough and improve EOR performance. In this study, a rich gas EOR pilot in the Bakken was carefully analyzed to collect the essential reservoir and operational data. A simulation model with 16 wells was then developed to reproduce the production history and predict the EOR performance with and without conformance control. EOR operational strategies, including single- and multiple-well HnP, with different gas injection constraints were investigated. The simulation results of single-well HnP without conformance control showed that a rich gas injection rate of at least 10 MMscfd was needed to yield meaningful incremental oil production. The strategy of conformance control via water injection could significantly improve oil production in the HnP well, but injecting an excessive amount of water also leads to water breakthrough and loss of oil production in the offset wells. By analyzing the production performance of the wells individually, the arrangement of wells was optimized for multiple-well HnP EOR. The multiwell results showed that rich gas EOR could improve oil production up to 7.4% by employing conformance control strategies. Furthermore, replacing rich gas with propane as the injection gas could result in 14% of incremental oil production.

02 PETROLEUM↗

Describing the Mechanism of Instability Suppression Using a Central Pilot Flame With Coupled Experiments and Simulations

Pilot flames are commonly used to extend combustor operability limits and suppress combustion oscillations in low-emissions gas turbines. Combustion oscillations, a coupling between heat release rate oscillations and combustor acoustics, can arise at the operability limits of low-emissions combustors where the flame is more susceptible to perturbations. While the use of pilot flames is common in land-based gas turbine combustors, the mechanism by which they suppress instability is still unclear. In this study, we consider the impact of a central jet pilot on the stability of a swirl-stabilized flame in a variable-length, single-nozzle combustor. Previously, the pilot flame was found to suppress the instability for a range of equivalence ratios and combustor lengths. We hypothesize that combustion oscillation suppression by the pilot occurs because the pilot provides hot gases to the vortex breakdown region of the flow that recirculate and improve the static, and hence dynamic, stability of the main flame. This hypothesis is based on a series of experimental results that show that pilot efficacy is a strong function of pilot equivalence ratio but not pilot flow rate, which would indicate that the temperature of the pilot products as well as the combustion intensity of the pilot flame play more of a role in oscillation stabilization than the length of the pilot flame relative to the main flame. Further, the pilot-flame efficacy increases with pilot-flame equivalence ratio until it matches the main-flame equivalence ratio; at pilot equivalence ratios greater than the main equivalence ratio, the pilot-flame efficacy does not change significantly with pilot equivalence ratio. To understand these results, we use large-eddy simulation (LES) to provide a detailed analysis of the flow in the region of the pilot flame and the transport of radical species in the region between the main flame and pilot flame. Furthermore, the simulation, using a flamelet/progress variable-based chemistry tabulation approach and standard eddy viscosity/diffusivity turbulence closure models, provides detailed information that is inaccessible through experimental measurements.

42 ENGINEERING↗

Final Report for Water Electrodialysis Reversal Pilot

This final report presents all the work and tests performed during ION Clean Energy’s Water Electrodialysis Reversal Pilot referred to as the “WERP” Project (DE-FE-0032066). ION Clean Energy Engineering (ION) and Nebraska Public Power District (NPPD) executed the Electrodialysis Reversal (EDR) Pilot Study and developed a commercial cost estimate needed to evaluate the retrofit of an EDR system to NPPD’s Gerald Gentleman Station (GGS). The proven project team was comprised of NPPD, Sargent & Lundy (S&L) and ElectroSep, who is a leading developer, fabricator and operator of electrodialysis units. ION, working in conjunction with NPPD and ElectoSep, developed a test program for evaluating the performance of the EDR technology proposed to be employed and evaluated for this pilot. The Department of Energy’s National Energy and Technology Laboratory (DOE/NETL) awarded ION Clean Energy, Inc. a single budget period (BP) of $816,759 with $207,942 of in-kind contribution from NPPD to investigate ElectroSep’s Electrodialysis technology to clean grey water from NPPD’s GGS.

01 COAL, LIGNITE, AND PEAT↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Drone Fleet Summary: NNLEMS UxS Rolodex entry for Sandia

Sandia’s UAS Aviation Operations Unit (UAOU) was established in 2019 to be the single entity at Sandia conducting UAS Ops in support the labs Uncrewed Aircraft Systems (UAS) activities. The UAOU currently consists of >330 FAA Registered UAS with a large variety of primarily Class 1&2 UAS: fixed wing (>90), multi-rotor (>230), hybrids, VTOLs, jets, and balloons. Many of these are threat vehicles presented as targets to Counter-UAS (CUAS) systems as part of performance tests, with the remainder in support of other projects across Sandia often with custom payload needs. The UAOU has ~15 primary pilots and reach back to another ~45 FAA Certified Remote Pilots across Sandia. The team conducts flight and CUAS operations at many test locations, including OCONUS. Sandia was awarded the 2024 DOE Federal Aviation Safety Program Award.

42 ENGINEERING↗

Optical Investigation of Catalyst Heating Operation in a Light-Duty Compression-Ignition Engine

It is well known that cold start engine operation contributes a majority of tail-pipe emissions during a vehicle drive cycle. Aftertreatment catalysts have poor conversion efficiency during this period due to low conversion efficiency at temperatures less than their light-off temperature. A late post injection strategy, with a delayed injection to increase exhaust enthalpy, can help decrease the time required to heat-up the catalyst. However, late injections into conditions with decreasing temperature and density can result in high emissions and combustion instability. In this study a three-injection strategy with a late-post injection was investigated in an optically-accessible engine. For the first two injections (pilot and main) timing and duration were held constant as the post injection timing was swept and duration varied to hold load constant, at a relevant light-load catalyst heating operating condition. Simultaneous double-pass schlieren and OH chemiluminescence data were acquired in an optically-accessible 0.4 L single-cylinder engine to understand spray characteristics and combustion behavior for #2 diesel fuel. Optical images analysis revealed higher liquid penetration and lower vaporization of the liquid fuel jet as post injection is retarded. It is also observed that retarding post injection timing to +25 CAD resulted in lower observed soot concentration in the piston bowl.

99 GENERAL AND MISCELLANEOUS↗

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗

Simultaneous Control of Unburned NH 3 and NO x Emissions From High Load Dual-Fuel Ammonia Operation on a High-Speed Diesel Engine Using a Cu-SCR System

Dual-fuel ammonia strategies are being investigated as a promising way to utilize NH 3 as an alternative fuel for internal combustion engines in the maritime sector. One of the remaining barriers to implementing dual-fuel NH 3 combustion strategies is understanding ways to minimize unburned NH 3 and nitrogen oxide (NO x ) emissions from these engines, both of which are elevated relative to a conventional diesel baseline. Selective catalytic reduction (SCR) systems are widely used for lean NO x emission controls for engines across transportation and stationary energy applications. SCR systems use a reducing agent, such as NH 3 , to react with NO x in the exhaust, converting it into nitrogen and water. Typically, NH 3 is injected into the exhaust as a urea solution. In dual-fuel NH 3 engines, where unburned NH 3 is present in the exhaust, an SCR system could be used to mitigate both NH 3 and NO x emissions. The presented work evaluates a commercial copper-zeolite SCR and ammonia slip catalyst system, designed for on-road diesel engine applications, for controlling unburned NH 3 and NO x emissions from a dual-fuel NH 3 combustion engine. The aftertreatment system was installed downstream of a single-cylinder four-stroke diesel engine that has been modified for dual-fuel ammonia use. Furthermore, the emissions were characterized by using a Fourier transform infrared spectrometer for both late- and early-injection diesel pilot strategies over three air–fuel equivalence ratios spanning from 1.6 to 1.0 at 1200 rpm and 12.6 bar IMEP g condition (with greater than 95% ammonia energy fraction). Initial findings indicate that the SCR achieves more than 99% NO x conversion with less than 50 ppm NH 3 slip at air–fuel equivalence ratios greater than 1.4 at the operating conditions investigated. However, these benefits are accompanied by additional N 2 O emissions that are formed over the Cu-SCR.

Catalysts↗

Modeling and Proof-of-Concept of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing collaboration searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a pilot experiment realization of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD coaxial reflector setup allows for the focusing of converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within $\SI{50}{\micro\metre}$ in the axial dimension. Additionally, it is demonstrated that the blackbody photon source used in this calibration must be at a temperature of at least $\SI{15}{\kelvin}$ to $\SI{40}{\kelvin}$, depending on the sensitivity of the SNSPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Flex-Fuel Prechamber Enabled Mixing-Controlled Combustion With Gasoline/Ethanol Blends at High Load

This numerical study focuses on the characterization of prechamber-enabled mixing-controlled combustion (PC-MCC) at ~18 bar brake mean effective pressure (BMEP) and 2200 rpm with 10% by volume ethanol-gasoline blend (E10) and pure ethanol (E100). Computational fluid dynamic (CFD) simulations of a stock and prechamber retrofitted single-cylinder Caterpillar C9.3B are carried out using CONVERGE. Prechamber equivalence ratio at spark timing, prechamber spark timing advance, and main chamber injection strategy are assessed with respect to their impact on ignition assistance performance and emissions characteristics relative to a diesel baseline at the same boundary conditions. Simulation results indicate that PC-MCC is flex-fuel capable and operates well for both E10 and E100 at the operating conditions considered. The results demonstrate that the use of a pilot-main injection strategy enables spark timing in the prechamber to be advanced and thus reduces spark plug firing pressure while maintaining robust ignition assistance. Results also indicate that the rich prechamber operation is favored for improved ignition assistance capabilities. Furthermore, the findings of this work suggest that a heavy-duty vehicle using a PC-MCC engine can utilize any blend of gasoline and ethanol, up to including pure ethanol, with no major sacrifices in performance relative to the diesel engine.

33 ADVANCED PROPULSION SYSTEMS↗