Search NASASearch

SEARCH · Search NASA

Results for “Strain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of the tensile stress-strain behavior of elastomers at constant strain rates. I - Criteria for separability of the time and strain effects

A theoretical analysis of the tensile stress-strain relation of elastomers at constant strain rate is presented which shows that the time and the stress effect are separable if the experimental time scale coincides with a segment of the relaxation modulus that can be described by a single power law. It is also shown that time-strain separability is valid if the strain function is linearly proportional to the Cauchy strain, and that when time-strain separability holds, two strain-dependent quantities can be obtained experimentally. In the case where time and strain effect are not separable, superposition can be achieved only by using temperature and strain-dependent shift factors.

Hong, S. D.

The Development of a PdCr Integral Weldable Strain Measurement System Based on NASA Lewis PdCr/Pt Strain Sensor for User-Friendly Elevated Temperature Strain Measurements

This report describes the development of a user friendly weldable strain gage employing the NASA Lewis PdCr/Pt wire strain sensor. The NASA sensors are pre-attached to Hastelloy X or Titanium alloy shims using name spray techniques developed under previous NASA programs. The weldable sensors are then pre-stabilized for 50 hours at 780 C in air. A weldable terminal and high temperature cable is then connected to the sensor and the assembly is pre-calibrated over the full test temperature range. Calibrated resistors are inserted into a bridge completion module at the cool end of the cable to condition the sensor in half or full bridge configuration. The sensor is attached to the structure using a common capacitive discharge spot welder. No additional high temperature stabilization or calibration is required. The resultant device is a pre-calibrated strain transducer which can be plugged into any common variety strain instrumentation.

Wnuk, S. P., Jr.

An investigation of strain cycling behavior of 7075-T6 aluminum under combined state of strain: The effects of out-of-phase, biaxial strain cycling on low cycle fatigue

The effect of out-of-phase strain cycling on the low cycle fatigue of biaxially loaded specimens is discussed. A method to apply phase angles between two strains imposed in two different directions was developed. The data and the proposed theoretical analysis are part of a research program on biaxial strain cycling effect on fatigue life of structural materials.

Zamrik, S. Y.

Strain activation of bovine aortic smooth muscle cell proliferation and alignment: study of strain dependency and the role of protein kinase A and C signaling pathways

Smooth muscle cell (SMC) phenotype can be altered by physical forces as demonstrated by cyclic strain-induced changes in proliferation, orientation, and secretion of macromolecules. However, the magnitude of strain required and the intracellular coupling pathways remain ill defined. To examine the strain requirements for SMC proliferation, we selectively seeded bovine aortic SMC either on the center or periphery of silastic membranes which were deformed with 150 mm Hg vacuum (0-7% center; 7-24% periphery). SMC located in either the center or peripheral regions showed enhanced proliferation compared to cells grown under the absence of cyclic strain. Moreover, SMC located in the center region demonstrated significantly (P < 0.005) greater proliferation as compared to those in the periphery. In contrast, SMC exposed to high strain (7-24%) demonstrated alignment perpendicular to the strain gradient, whereas SMC in the center (0-7%) remained aligned randomly. To determine the mechanisms of these phenomena, we examined the effect of cyclic strain on bovine aortic SMC signaling pathways. We observed strain-induced stimulation of the cyclic AMP pathway including adenylate cyclase activity and cyclic AMP accumulation. In addition, exposure of SMC to cyclic strain caused a significant increase in protein kinase C (PKC) activity and enzyme translocation from the cytosol to a particulate fraction. Further study was conducted to examine the effect of strain magnitude on signaling, particularly protein kinase A (PKA) activity as well as cAMP response element (CRE) binding protein levels. We observed significantly (P < 0.05) greater PKA activity and CRE binding protein levels in SMC located in the center as compared to the peripheral region. However, inhibition of PKA (with 10 microM Rp-cAMP) or PKC (with 5-20 ng/ml staurosporine) failed to alter either the strain-induced increase in SMC proliferation or alignment. These data characterize the strain determinants for activation of SMC proliferation and alignment. Although strain activated both the AC/cAMP/PKA and the PKC pathways in SMC, singular inhibition of PKA and PKC failed to prevent strain-induced alignment and proliferation, suggesting either their lack of involvement or the multifactorial nature of these responses.

Non-NASA Center

Demonstration test of burner liner strain measurements using resistance strain gages

A demonstration test of burner liner strain measurements using resistance strain gages as well as a feasibility test of an optical speckle technique for strain measurement are presented. The strain gage results are reported. Ten Kanthal A-1 wire strain gages were used for low cycle fatigue strain measurements to 950 K and .002 apparent strain on a JT12D burner can in a high pressure (10 atmospheres) burner test. The procedure for use of the strain gages involved extensive precalibration and postcalibration to correct for cooling rate dependence, drift, and temperature effects. Results were repeatable within + or - .0002 to .0006 strain, with best results during fast decels from 950 K. The results agreed with analytical prediction based on an axisymmetric burner model, and results indicated a non-uniform circumferential distribution of axial strain, suggesting temperature streaking.

Grant, H. P.

Strain sensor comprising a strain sensitive, two-mode optical

A strain sensor uses an optical fiber including a strain sensitive portion and at least one strain insensitive portion. The strain sensitive portion is mounted on the surface of a structure at a location where a strain is desired to be measured. The strain insensitive portion(s) may be fused to the strain sensitive portion to transmit light therethrough, so that the resulting pattern may be detected to determine the amount of strain by comparison with a similar fiber not subjected to strain, or with the light pattern produced when the fiber is not under strain.

Egalon, Claudio Oliveira

A study of the effect of apparent strain on thermal stress measurement for two types of elevated temperature strain gages

A weldable type strain gage was used to measure low level thermal stress in an elevated temperature environment. Foil strain gages used in a comparative manner reveal that the apparent strain of weldable strain gages is not sufficiently known to acquire accurate low level thermal stress data. Apparent strain data acquired from coupon tests reveals a large scatter in apparent strain characteristics among the weldable strain gages. It is concluded that apparent strain data for individual weldable strain gages must be required prior to installation if valid thermal stress data is to be obtained through the temperature range of room temperature to 755 K (900 F).

Jenkins, J. M.

High temperature strain gage apparent strain compensation

Once an installed strain gage is connected to a strain indicating device and the instrument is balanced, a subsequent change in temperature of the gage installation will generally produce a resistance change in the gage. This purely temperature-induced resistance will be registered by the indicating device as a strain and is referred to as 'apparent strain' to distinguish it from strain due to applied stress. One desirable technique for apparent strain compensation is to employ two identical gages with identical mounting procedures which are connected with a 'half bridge' configuration where gages see the same thermal environment but only one experiences a mechanical strain input. Their connection in adjacent arms of the bridge will then balance the thermally induced apparent strains and, in principle, only the mechanical strain remains. Two approaches that implement this technique are discussed.

Holmes, Harlan K.

Effect of strain isolator pad modulus on inplane strain in Shuttle Orbiter thermal protection system tiles

The thermal protection system used on the Space Shuttle orbiter to determine strains in the reusable surface insulation tiles under simulated flight loads was investigated. The effects of changes in the strain isolator pad (SIP) moduli on the strains in the tile were evaluated. To analyze the SIP/tile system, it was necessary to conduct tests to determine inplane tension and compression modulus and inplane failure strain for the densified layer of the tiles. It is shown that densification of the LI-900 tile material increases the modulus by a factor of 6 to 10 and reduces the failure strain by about 50%. It is indicated that the inplane strain levels in the Shuttle tiles in the highly loaded regions are approximately 2 orders of magnitude lower than the failure strain of the material. It is concluded that most of the LI-900 tiles on the Shuttle could be mounted on a SIP with tensile and shear stiffnesses 10 times those of the present SIP without inplane strain failure in the tile.

Sawyer, J. W.

Measurement of high temperature strain by the laser-speckle strain gauge

By using the laser-speckle strain gauge, the strain of metal at the temperature lower than 250 C is measured. The principle of the gauge is to measure the expansion or contraction of the fine structures of surface by detecting the resultant speckle displacement in an optoelectronic way, whereby the effect of rigid-body motion is automatically cancelled out with the aid of a differential detection system. A transportable apparatus was built and a comparison experiment performed with a resistance strain gauge at room temperature. It has a strain sensitivity of .00002, a gauge length smaller than 1 mm, and no upper limit in a range of strain measurement. In the measurement of high-temperature strain it is free from the need for a dummy gauge and insensitive to an electric drift effect. As examples of strain measurement at high-temperature, thermal expansion and contraction of a top of a soldering iron are measured. The interval of the measurement can be made at shortest 1.6 sec. and the change in the strain is clearly followed until the ultimate stationary temperature is reached.

Yamaguchi, I.

A comparison of eastern North American seismic strain-rates to glacial rebound strain-rates

Glacial rebound strain-rates computed using a simple Laurentide glacial loading model are of the order of 10(exp -9) per year within the region of glaciation and extending several hundred kilometers beyond. The horizontal strain-rates receive approximately equal contributions from horizontal and vertical velocities, a consequence of the spherical geometry adopted for the Earth model. In the eastern United States and southeastern Canada the computed strain-rates are 1-3 orders of magnitude greater than an estimate of the average seismic strain-rate (Anderson, 1986) and approximately 1 order of magnitude greater than predicted erosional strain-rates. The predicted glacial rebound strain-rates are not, in general, oriented in such a way as to augment the observed state of deviatoric stress, possibly explaining why the seismic strain-rates are much smaller than the glacial rebound strain-rates. An exception to this may be seismically active regions in the St. Lawrence valley.

James, Thomas S.

Experimental Evaluation of White Light Fabry-Perot Interferometry Fiber-Optic Strain Gages when Measuring Small Strains

An experimental study was conducted to evaluate whether fiber optic strain gages (FOSG) are "better" sensors than typical foil gages. A particularly attractive feature of FOSG was their specified resolution of 0.01% of full-scale (0.1 micro strain for 1000 micro strain full-scale). This feature would make FOSG practical tank level sensors, by measuring very small strains on the support structure of a tank. A specific application in mind was to measure liquid oxygen tank level, with support beams that were predicted to contract approximately 11 micro strain as the tank goes from empty to full. Among various fiber optic technologies currently available, Fabry-Perot Interferometry using white light was selected. This technology exhibits highly desirable feature such as absolute strain measurement, linearity over its full-scale, and temperature compensation. However, experiment results suggest that the resolution is 0.8 micro strain, at best, calibration from one sensor to another can be off by 2.4 - 11.2%, and that temperature compensation is not fully predictable, with errors of up to 3.5 micro strain over an 11C range. Hence, when compared with classic foil gages, FOSG possess less accuracy, similar resolution and repeatability (precision), and superior linearity over their entire operating range. They are immune to EMI and their signals suffer minimal degradation over long distances. It is also expected that drift with time will be minimal in FOSG whereas the gage factor of foil sensors changes over time when exposed to varying environmental conditions. In conclusion, FOSG are "better" than foil gages as long as the application allows calibration of individual units as installed for operation.

St.Cyr, William

The apparent strain stability and repeatability of a BCL3 resistance strain gage

Experiments were conducted at NASA-Lewis to study the effect of microstructural instability on the apparent strain stability and reproducibility of a BCL3 resistance strain gage. The resistance drift of the gage at various temperatures in the phase transition temperature range (PTTR) was measured. The effects of the heating and cooling rates with which the gage passed through the PTTR on the apparent strain characteristics of the gage were also studied. BCL3 gage, like other Fe-Cr-Al based gages, exhibited apparent strain instability in the temperature range of 700 to 1100 F due to the reversible microstructural transition the gage materials experienced in this temperature range. The BCL3 gage had a maximum apparent strain drift in the neighborhood of 770 F with an average drift rate of approx. -440 microstrain/hr in 2 hrs. The use of the BCL3 gage as well as other Fe-Cl-Al based gages for static strain measurements within the PTTR should be avoided unless the time durations in the PTTR are small enough to introduce a neglible drift. The microstructure transition that the BCL3 gage underwent occurred in the temperature range of 750 to 1050 F during heating and around 1000 to 800 F during cooling. The heating rate, and, in particular, the cooling rate with which the gage passed through the PTTR affected the shape and the repeatability of the apparent strain curve of the gage.

Lei, Jih-Fen

The Effect of Strain Rate on the Evolution of Plane Wakes Subjected to Irrotational Strains

Direct numerical simulations of time-evolving turbulent plane wakes developing in the presence of irrotational plane strain applied at three different strain rates have been generated. The strain geometry is such that the flow is compressed in the streamwise direction and expanded in the cross-stream direction with the spanwise direction being unstrained. This geometry is the temporally evolving analogue of a spatially evolving wake in an adverse pressure gradient. A pseudospectral numerical method with up to 16 million modes is used to solve the equations in a reference frame moving with the irrotational strain. The initial condition for each simulation is taken from a previous turbulent self-similar plane wake direct numerical simulation at a velocity deficit Reynolds number, Re, of about 2,000. Although the evolutions of many statistics are nearly collapsed when plotted against total strain, there are some differences owing to the different strain rate histories. The impact of strain-rate on the wake spreading rate, the peak velocity deficit, the Reynolds stress profiles, and the flow structure is examined.

Rogers, Michael M.

Adaptor for Measuring Principal Strains with Tuckerman Strain Gage

An adapter is described which uses three Tuckerman optical strain gages to measure the displacement of the three vortices of an equilateral triangle along lines 120 degrees apart. These displacements are substituted in well-known equations in order to compute the magnitude and direction of the principal strains. Tests of the adaptor indicate that principal strains over a gage length of 1.42 inch may be measured with a systematic error not exceeding 4 percent and a mean observational error of the order of + or minus 0.000006. The maximum observed error in strain was of the order of 0.00006. The directions of principal strains for unidirectional stress were measured with the adaptor with an average error of the order of 1 degree.

INSTRUMENTS-STRAIN GAUGES-RUGE & DE FOREST

An experimental evaluation of apparent strain from foil strain gauges attached to carbon composite substrates

An experimental evaluation of apparent thermal strains is conducted using various combinations of substrate/gauge/attachment structure and redundant high temperature extensometry. It is found that the extensometry could either confirm independent measurements of the substrate's thermal expansion, or quantify nonzero mechanical strains resulting from uncertain material behavior and boundary conditions. Apparent strain and thermal expansion behavior data can then be used to modify the raw strain measurements in order to determine either stress producing or total strains. Limitation of the correction procedure for the three selected strain gauges is noted which is due to relatively large gauge/attachment variability.

Scott, B. R.

A resistance strain gage with repeatable and cancellable apparent strain for use to 800 C

A temperature compensated static strain gage, which is fabricated from palladium-13w/o chromium (Pd13Cr) alloy and a platinum (Pt) compensator, is being developed and was tested over a temperature range to 800 C at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 800 C than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4w/o zirconia overcoating. Test results to 800 C indicate apparent strain variations of less than 300 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. Apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen