Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface Logistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Earthquake detection in a simulated lunar regolith using distributed acoustic sensing

Current models of inner lunar geology have largely been inferred from the seismic experiments and observations performed during the Apollo missions that comprised a relatively small number of seismic instruments. Refining constraints on fundamental lunar relationships such as crust-mantle and mantle-core boundaries in the future will require seismic arrays spanning larger epicentral distances. A promising technology for installing dense seismic arrays with minimal human effort is distributed acoustic sensing (DAS), an approach that allows a single length of fiber optic cable to act as hundreds or thousands of sensors when coupled with a DAS interrogator. While terrestrial uses of DAS technology for seismic monitoring rely on burying the cable to maximize fidelity of seismic signal transmission to the fiber, digging meters of trench to bury optical fiber on lunar or planetary surfaces is logistically infeasible. To evaluate DAS signal attenuation due to surface deployment of cable in lunar regolith, we completed earthquake detection analyses that evaluated the sensitivity of an optic-fiber DAS system to seismic signals at different burial depths. We deployed a single-mode fiber in a 10-m open-bottom wooden box filled with a lunar regolith simulant (LRS) with fiber buried at different depths within the LRS and recorded signals for four regional and local earthquakes. The results were used to identify and evaluate signal attenuation in surface-deployed fiber compared to buried fiber in the LRS. Burial depth responses to active-source signals were also evaluated similar to previous studies characterizing DAS sensitivity of surface-deployed fiber. Atmospheric noise was minimal as the cable was deployed in an indoor environment; however, where observed, atmospheric and anthropogenic noise was filtered out using the same bandpass filtering used to identify earthquake events. We found that signal attenuation of the surface-deployed fiber compared to buried fiber was relatively high in active-source experiments but was not consistently observed in earthquake signals. That burial depth is not highly correlated to attenuation of the observed earthquake signals indicates that in a noise-limited environment, placing DAS-interrogated fiber directly at the regolith surface may be a promising deployment strategy to consider for sensing remote seismic signals during lunar exploration.

58 GEOSCIENCES↗

Three-dimensional fracture continuum characterization aided by surface time-domain electromagnetics and hydrogeophysical joint inversion—proof-of-concept

Efficient and safe production of hydraulically fractured reservoirs benefits from the prediction of their geometrical attributes. Geophysical methods have the potential to provide data that are sensitive to fracture geometries, alleviating the typically sparse nature of in situ reservoir observations. Moreover, surface-based methods can be logistically and economically attractive since they avoid operational interference with the injection well infrastructure. Here, we investigate the potential of the surface-based time-domain electromagnetic (EM) method. EM methods can play an important role owing to their sensitivity to injection-induced fluid property changes. Two other advantageous factors are the EM signal-enhancing effect of vertical steel-cased wells and the fact that injected proppants can be enhanced to produce a stronger electrical conductivity contrast with the reservoir’s connate fluid. Nevertheless, an optimal fracture characterization will no doubt require the integration of EM and reservoir injection and production data. We hence carry out our investigations within a hydrogeophysical parameter estimation framework where EM data and injection flow rates are combined in a fully coupled way. Given the interdisciplinary nature of coupled hydrogeophysical inverse modeling, we dedicate one section to laying out key aspects in a didactic manner.

58 GEOSCIENCES↗

A spatial-statistical investigation of surface expressions associated with cyclic steaming in the Midway-Sunset Oil Field, California

In the Midway Sunset Oil Field in Central California, operators inject steam into the shallow diatomite formation to enhance heavy oil recovery through imbibition, wettability alteration, and viscosity reduction, among other mechanisms. The injected steam, however, does not always remain in the reservoir or return through the wells. In two zones in the study area, the steam comes out at the surface, creating sinkholes, seeps, and steam outlets. These phenomena, called “surface expressions,” pose safety and environmental hazards. Even though these surface expressions are a widespread problem in Central California, they are not well documented and understood. Possible causes of the surface expressions include: high injection pressure, structurally controlled flow patterns, leakage of steam through old improperly abandoned wells, high injection volumes, or flow along naturally occurring faults, among other possible factors. This work examines attributes of the zones with surface expressions in order to determine factors that may contribute to their occurrence. Spatial statistical analysis using logistic regression, random forests, and classification trees is used to explore the relationship between the surface expressions and geological and production-related attributes. The results point to a significant spatial correlation between the surface expressions and two predictors: concentration of plugged wells and geologic seal thickness. The results guide follow-up studies to further investigate the role of well abandonment and seal thickness in the occurrence of surface expressions.

02 PETROLEUM↗

Building an EPA Class VI Permit Application

Summary To accelerate the commercialization of carbon capture and storage (CCS), the US Department of Energy (US DOE) is building on decades of characterization efforts and pilot-scale projects through their CarbonSAFE program. Administered through their National Energy Technology Laboratory, this program seeks to bring fully integrated projects to the sector that can store more than 50 million tonnes of CO2 over a 30-year period. The program, which was enacted before the enhancement of Internal Revenue Code Section 45Q, is in the capture assessment, characterization, and permitting phase. The objectives of this paper are to discuss (a) the injection permitting requirements of the CarbonSAFE projects; (b) information gathering in support of the permit; (c) the timelines of field development and permit-related activities; (d) the major technical components of the field development plan; and (e) early feedback from the regulators toward acceptance of the permit. In Mississippi, more than 30,000 acres have been characterized by six deep characterization wells, a deep groundwater well, and 92 line miles of 2D seismic as part of the CarbonSAFE Project ECO2S. During the acquisition of seismic data, all receiver lines were live, which resulted in the generation of a pseudo-3D seismic design. The incorporation of a 3D seismic survey was not included as part of this project due to logistical difficulties presented by the undulating, wooded surface terrain. A suite of openhole geophysical logs was taken from each well, allowing for a detailed interpretation of prospective storage reservoirs and confining intervals to complement the analysis carried out on the 290 ft of a whole core that was cut through the prospective confining zone and storage reservoir. The detailed geologic and reservoir data were assembled and entered into a 3D model to assess the injection capacity and the area of review (AoR). This information fed into the detailed corrective action, monitoring, testing, and postinjection site care (PISC) modeling. The results have been exceptional. The geologic assessment has revealed three primary storage targets, ranging in depth from 3,500 ft to 6,000 ft. These storage reservoirs net 1,300 ft of sandstone, with mean porosity and permeability of 29% and 3.6 darcies, respectively. Together, these reservoirs have storage capacities that may exceed 20 million tonnes per square mile, making this a gigatonne prospect. Forward modeling of the project resulted in an AoR of 16 sq miles, injecting about 8000 t/d, for 30 years, via two deep injection wells. The excellent confining characteristics of the caprock, relatively simple geologic structure, and lack of historical well drilling activity in this area provide excellent containment of the injected CO2. Based on this work, the project has proposed 20 years of PISC. To date, only two US CO2 injection permits have been granted. These projects relied on a singular capture point feeding a singular sequestration point (source to sink), and considerations have not been made to garner CO2 emissions from other industrial sources. The Kemper County Storage Complex is a first-of-its-kind storage hub concept that looks to develop an area capable of storing significant quantities of CO2 from the region. Also, this work will show how characterization efforts, geological and numerical modeling efforts, and plan development were constructed in support of permit and incentives acceptance.

Energy & Fuels↗

Low-frequency Electromagnetic Detection Limits of Underground Nuclear Explosions

Underground nuclear explosions produce a broadband electromagnetic signal that can propagate to the surface at some distance. We perform a logistic regression on historical electromagnetic detections to calculate a probabilistic detection curve for prediction of the propagation distance for any given underground nuclear explosion. The curve predicts positive detections at scaled ranges of 2414.6, 2025.7, 1908.3, and 1672.4 m/ktonne 1/3 at probabilities of 50, 90, 95 and 99%, respectively. For a theoretical 100 ktonne underground nuclear explosion these scaled ranges translate to absolute ranges of 11.2, 9.4, 8.9, and 7.8 km at probabilities of 50, 90, 95 and 99%, respectively. We also motivate a need for improved electromagnetic sensor design and deployment by extending the detection analysis using the quoted signal-to-noise ratio of two and noise amplitude of 10 pT along with attenuation relationships that go as 1/r to 1/r 3 . We find that reducing the noise floor by a factor often could extend the detection limit to approximately 5 to 25 km/ktonne 1/3 , which translates to 24 to 112 km for a theoretical 100 ktonne underground nuclear explosion.

58 GEOSCIENCES↗

The Effect of Updraft Entrainment on Convective Cell Deepening in Realistic Large-Eddy Simulations

Entrainment of surrounding cooler and drier air into convective updrafts is one of the key processes that influence deep convection initiation and growth. Numerous studies have investigated the effect of entrainment on isolated convective cloud growth in idealized simulations, but the importance of this effect in realistic conditions with many interacting convective clouds remains uncertain. We examine the impact of entrainment on the depth reached by convective clouds in realistic large-eddy simulations (LES) over central Argentina during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign. Cloudy updrafts and their associated properties are assigned to convective cells tracked with radar reflectivity signatures. Several thousand convective cells are tracked over two high convective available potential energy (CAPE) and two low CAPE cases that support cells of varying depths and intensities. Entrainment is calculated explicitly as the fluxes of air into the outer surface of each cloudy updraft. Single-predictor logistic regression models are used to determine the relative importance of updraft, near-updraft, and preconvective initiation atmospheric conditions in predicting whether convective cells become deep. We then build a multiple-predictor regression model pairing important updraft and meteorological metrics with fractional entrainment rate. The probability of cells transitioning to deep convection is most sensitive to ambient 600-hPa relative humidity (42% of total metric contribution to cloud depth predictability), followed by low-level CAPE (28%), cloud-base updraft width (19%), and fractional entrainment (11%). Thus, the initial width of the updraft along with potential buoyancy and its dilution through the midtroposphere collectively determine whether deep convection will result from shallower clouds.

54 ENVIRONMENTAL SCIENCES↗

A community-based evaluation of proximity to unconventional oil and gas wells, drinking water contaminants, and health symptoms in Ohio

Highlights: • We conducted a community-based study on unconventional oil and gas (UO&G) in Ohio. • We explored UO&G proximity in relation to water contamination and health symptoms. • Contaminant detection and concentrations decreased with greater distance to UO&G. • UO&G proximity was associated with increased general health symptoms (e.g. fatigue). • Communities near UO&G may be more likely to experience environmental health impacts. Over 4 million Americans live within 1.6 km of an unconventional oil and gas (UO&G) well, potentially placing them in the path of toxic releases. We evaluated relationships between residential proximity to UO&G wells and (1) water contamination and (2) health symptoms in an exploratory study. We analyzed drinking water samples from 66 Ohio households for 13 UO&G-related volatile organic compounds (VOCs) (e.g., benzene, disinfection byproducts [DBPs]), gasoline-range organics (GRO), and diesel-range organics. We interviewed participants about health symptoms and calculated metrics capturing proximity to UO&G wells. Based on multivariable logistic regression, odds of detection of bromoform and dibromochloromethane in surface water decreased significantly as distance to nearest UO&G well increased (odds ratios [OR]: 0.28–0.29 per km). Similarly, distance to nearest well was significantly negatively correlated with concentrations of GRO and toluene in ground water (r{sub Spearman}: −0.40 to −0.44) and with concentrations of bromoform and dibromochloromethane in surface water (r{sub Spearman}: −0.48 to −0.50). In our study population, those with higher inverse-distance-squared-weighted UO&G well counts within 5 km around the home were more likely to report experiencing general health symptoms (e.g. stress, fatigue) (OR: 1.52, 95%CI: 1.02–2.26). This exploratory study, though limited by small sample size and self-reported health symptoms, suggests that those in closer proximity to multiple UO&G wells may be more likely to experience environmental health impacts. Further, presence of brominated DBPs (linked to UO&G wastewater) raises the question of whether UO&G activities are impacting drinking water sources in the region. The findings from this study support expanded studies to advance knowledge of the potential for water quality and human health impacts; such studies could include a greater number of sampling sites, more detailed chemical analyses to examine source attribution, and objective health assessments.

54 ENVIRONMENTAL SCIENCES↗

Microphysics of summer clouds in central West Antarctica simulated by the Polar Weather Research and Forecasting Model (WRF) and the Antarctic Mesoscale Prediction System (AMPS)

Abstract. The Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) provided a highly detailed set of remote-sensing and surface observations to study Antarctic clouds and surface energy balance, which have received much less attention than for the Arctic due to greater logistical challenges. Limited prior Antarctic cloud observations have slowed the progress of numerical weather prediction in this region. The AWARE observations from the West Antarctic Ice Sheet (WAIS) Divide during December 2015 and January 2016 are used to evaluate the operational forecasts of the Antarctic Mesoscale Prediction System (AMPS) and new simulations with the Polar Weather Research and Forecasting Model (WRF) 3.9.1. The Polar WRF 3.9.1 simulations are conducted with the WRF single-moment 5-class microphysics (WSM5C) used by the AMPS and with newer generation microphysics schemes. The AMPS simulates few liquid clouds during summer at the WAIS Divide, which is inconsistent with observations of frequent low-level liquid clouds. Polar WRF 3.9.1 simulations show that this result is a consequence of WSM5C. More advanced microphysics schemes simulate more cloud liquid water and produce stronger cloud radiative forcing, resulting in downward longwave and shortwave radiation at the surface more in agreement with observations. Similarly, increased cloud fraction is simulated with the more advanced microphysics schemes. All of the simulations, however, produce smaller net cloud fractions than observed. Ice water paths vary less between the simulations than liquid water paths. The colder and drier atmosphere driven by the Global Forecast System (GFS) initial and boundary conditions for AMPS forecasts produces lesser cloud amounts than the Polar WRF 3.9.1 simulations driven by ERA-Interim.

54 ENVIRONMENTAL SCIENCES↗

SHASTA-HELP: Hydrogen Estimator for Logistical Planning Tool

Underground reservoirs offer a promising option for medium- and long-term hydrogen storage that could potentially be safer and more cost-effective than surface alternatives. Currently, there are three underground hydrogen storage (UHS) facilities in the United States, which operate solely in salt caverns and store hydrogen primarily for industrial purposes. Salt formations favorable for geologic storage are geographically limited in the U.S. If a hydrogen economy is to develop, expansion of UHS to other geologic formations such as depleted gas fields and saline aquifers will be necessary to increase the availability of hydrogen storage. While research into the feasibility of storing hydrogen in these formations is ongoing, tools and methodologies are needed for characterizing the hydrogen storage potential in these reservoirs. We introduce the Hydrogen Estimator for Logistical Planning (HELP) tool from the Subsurface Hydrogen Assessment, Storage, and Technology Acceleration (SHASTA) project (https://edx.netl.doe.gov/shasta). SHASTA-HELP is a suite of web-based tools that have numerous capabilities for UHS project planning.

Haeri, Foad↗

Variational encoder geostatistical analysis (VEGAS) with an application to large scale riverine bathymetry

Estimation of riverbed profiles, also known as bathymetry, plays a vital role in many applications, such as safe and efficient inland navigation, prediction of bank erosion, land subsidence, and flood risk management. The high cost and complex logistics of direct bathymetry surveys, i.e, depth imaging, have encouraged the use of indirect measurements such as surface flow velocities. However, estimating high-resolution bathymetry from indirect measurements is an inverse problem that can be computationally challenging. Here, we propose a reduced-order model (ROM) based approach that utilizes a variational autoencoder (VAE), a type of deep neural network with a narrow layer in the middle, to compress bathymetry and flow velocity information and accelerate bathymetry inverse problems from flow velocity measurements. In our application, the shallow-water equations (SWE) with appropriate boundary conditions (BCs), e.g., the discharge and/or the free surface elevation, constitute the forward problem, to predict flow velocity. Then, ROMs of the SWEs are constructed on a nonlinear manifold of low dimensionality through a variational encoder and the bathymetry inversion problem is derived on the low-dimensional latent space in a Hierarchical Bayesian setting. Further, the reformulation allows variational inference with a small number (e.g., $\mathscr{O}$ (100) of ROM runs and efficient uncertainty quantification. We have tested our inversion approach on a one-mile reach of the Savannah River, GA, USA. Once the neural network is trained (offline stage), the proposed technique can perform the inversion operation orders of magnitude faster than traditional inversion methods that are commonly based on linear projections, such as principal component analysis (PCA), or the principal component geostatistical approach (PCGA). Furthermore, tests show that the algorithm can estimate the bathymetry with good accuracy even with sparse flow velocity measurements.

54 ENVIRONMENTAL SCIENCES↗

Logistics simulation of a remediation effort for a hypothetical radiological contamination scenario

To mitigate the effects following a large-scale nuclear or radiological material release in an urban environment and to expedite recovery, the Integrated Wash-Aid Treatment Emergency Reuse System (IWATERS) was developed. IWATERS consists of three operations: washing contaminated surfaces with an ionic wash solution, collecting, and treating the contaminated wash solution on-site to remove contaminants, and reusing the treated solution throughout operations to preserve the clean water resource. This study develops a framework to simulate the logistics of IWATERS deployment, thereby gaining an understanding of the timeline for decontamination operations. For this purpose, the Analysis of Mobility Platform and GoldSim were leveraged for a hypothetical contamination scenario covering 65,200 m 2 of an urban center. The framework reveals that remediation progress is limited by several resources, notably the availability of vermiculite, a reactive clay that is required to treat the contaminated wash solution. Further, this study also presents how the simulation approach can be used to characterize alternatives to reduce the influence of limited resources on operational progress. Overall, this work lays the foundation for evaluating different decontamination methods through detailed logistics simulation, i.e., by refining simulation assumptions and expanding the range of scenarios the simulation can depict.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Evaluation of VEGETATION and PROBA-V Phenology Using PhenoCam and Eddy Covariance Data

High-quality retrieval of land surface phenology (LSP) is increasingly important for understanding the effects of climate change on ecosystem function and biosphere–atmosphere interactions. We analyzed four state-of-the-art phenology methods: threshold, logistic-function, moving-average and first derivative based approaches, and retrieved LSP in the North Hemisphere for the period 1999–2017 from Copernicus Global Land Service (CGLS) SPOT-VEGETATION and PROBA-V leaf area index (LAI) 1 km V2.0 time series. We validated the LSP estimates with near-surface PhenoCam and eddy covariance FLUXNET data over 80 sites of deciduous forests. Results showed a strong correlation (R 2 > 0.7) between the satellite LSP and ground-based observations from both PhenoCam and FLUXNET for the timing of the start (SoS) and R 2 > 0.5 for the end of season (EoS). The threshold-based method performed the best with a root mean square error of ~9 d with PhenoCam and ~7 d with FLUXNET for the timing of SoS (30th percentile of the annual amplitude), and ~12 d and ~10 d, respectively, for the timing of EoS (40th percentile).

47 OTHER INSTRUMENTATION↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Separate-Effects Tests for Studying Temperature-Gradient-Driven Cracking in UO 2 Pellets

We report a variety of normal operation and accident scenarios can generate thermal stresses large enough to cause cracking in light-water reactor (LWR) fuel pellets. Cracking of fuel pellets can lead to reduced heat removal, higher centerline temperatures, and localized stress in cladding, all of which impact fuel performance. It is important to experimentally characterize the thermal and mechanical behavior in the pellet before and after cracking to improve cracking models in fuel performance codes. However, in-reactor observation and measurement of cracking is very challenging due to the harsh environment and logistics. Recently, an experimental pellet cracking test stand was developed for separate effects testing of normal operations and accident temperature conditions, using thermal imaging to capture the pellet surface temperature for evaluation of thermal stresses and optical imaging to capture the evolution of cracking in real time. Experiments were performed using depleted uranium dioxide (UO 2 ) pellets, which are useful for collecting data valuable for development and validation of cracking models. A combination of induction and resistance heating was used to create an average temperature gradient of 236°C/cm and 193°C/cm before and after cracking respectively. Characterization of the pellets were done before as well as after cracking. The cracking patterns are somewhat different than those expected in a typical reactor because of the differences in thermal conditions and pellet microstructure. However, if the actual conditions of these experiments are reproduced in computational models, these out-of-pile tests on UO 2 pellets provide relevant data for modeling purposes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study on Intelligent Compaction-Equipment Logistics Scheduling and Propagation Characteristics of Vibration Wave in Nonlinear Systems with Multistability Based on Field Test

The equipment scheduling and propagation characteristics of vibration wave from vibratory roller ⟶ filling material nonlinear systems with multistability are the core problems of subgrade intelligent construction technology, and the logistics scheduling of the equipment is directly related to the construction efficiency. Aiming at the shortages, one typical subgrade located at the Gu’an station of Beijing-Xiong’an city railway is selected to research and finish the field tests; some findings are shown as follows: first, some valuable suggestions about the logistics scheduling of intelligent equipment are proposed, which can break the barriers between the organizations and improve construction efficiency; second, when the vibration wave propagates from the vibratory roller ⟶ surface of filling material ⟶ different buried depths of filling material, the peak acceleration of vibration wave gradually decreases and is hyperbolic distribution approximately. At the same time, the sensitive of attenuation is shown as follows: Z R 2 >0.9), and the concrete functional relationship among different amplitudes of harmonics can be summarized as y = Ae −BX ; fourth, the vibration energy is mainly concentrated near 10–30 Hz in the vibratory roller, but when the vibration wave propagates from vibratory roller⟶filling material, the vibration energy gradually decreases with the increase in depth, and the marginal spectrum gradually changes from one peak to two peaks, that is, 30–50 Hz and 50–100 Hz; fifth, the vibration energy in the vibrational wheel is distributed averagely in the compaction process, and the effective compaction time is two seconds, which will be helpful for revealing the propagation characteristics of vibration wave, optimizing the compaction quality control models and providing some support for the development of intelligent compaction theory of railway subgrade.

Han, Yixuan↗

NLR CSP Optical Facilities: Illuminating the Path Forward Through Innovation and Impact: Agreement 38490

This initiative is a multi-faceted project at the National Laboratory of the Rockies (NLR) aimed at strengthening its Concentrating Solar Power (CSP) Optical Facilities to advance the development of low-cost, high-performance materials for solar and other applications. The project's strategy is built on three pillars: strategic stakeholder engagement, diligent facility maintenance and utilization, and the development of new research capabilities. The overarching goal is to ensure the facilities remain state-of-the-art resources for industry and academia, thereby accelerating the conversion of concentrated sunlight into energy. A key driver of the project is an international Advisory Board, which provides critical guidance on research priorities and industry needs, leading to new collaborations and secured funding. This external engagement, combined with proactive outreach to industry partners, ensures the lab's work remains aligned with real-world challenges, including materials durability and performance certification. Significant efforts in facility maintenance have addressed challenges with aging infrastructure. Notable achievements include the complete refurbishment of the hail-damaged Ultra-Accelerated Weathering System (UAWS) and the successful replacement of a failing 15-year-old Lambda 1050 spectrophotometer with a new-generation model, substantially upgrading material characterization capabilities. These maintenance activities were complemented by achieving a prestigious ISO 9001:2015 certification for the Advanced Optical Materials Labs, formally recognizing the quality and reliability of NLR's measurement capabilities. Despite these successes, challenges remain, including high demand for the High Flux Solar Furnace (HFSF) and intermittent failures of other key instruments. The project has delivered major advancements in research techniques and capabilities. At the Flatirons campus, a new indoor laboratory, was established to house advanced deflectometry and photogrammetry systems for heliostat characterization. For on-sun testing, a novel, actively cooled turning mirror was developed for the HFSF, enabling more realistic testing of particle receivers and components. A collaboration with Virginia Tech successfully demonstrated the high-temperature durability of a new solar absorber coating through extensive cyclic testing. Concurrently, new modeling took place to better predict material degradation on rough, fractal surfaces. In summary, this project has systematically enhanced NLR's CSP Optical Facilities through strategic upgrades, rigorous maintenance, and stakeholder-guided research. By overcoming equipment failures, budgetary constraints, and logistical hurdles, the project has reinforced NLR's role as a central hub for CSP innovation and materials testing. Future work will focus on securing diverse funding, expanding collaborations, and continuing to provide the critical infrastructure needed to accelerate the development and deployment of next-generation technologies.

14 SOLAR ENERGY↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗