Search NASA⌕ Search

SEARCH · Search NASA

Results for “Synchrotron x-ray technique”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synchrotron X-ray diffraction measurements of single-crystal hydrogen to 26.5 gigapascals

The crystal structure and equation of state of solid hydrogen have been determined directly to 26.5 gigapascals at room temperature by new synchrotron X-ray diffraction techniques. Solid hydrogen remains in the hexagonal close packed structure under these pressure-temperature conditions and exhibits increasing structural anisotropy with pressure. The pressure-volume curve determined from the X-ray data represents the most accurate experimental measurement of the equation of state to date in this pressure range. The results remove the discrepancy between earlier indirect determinations and provide a new experimental constraint on the molecular-to-atomic transition predicted at higher pressures.

Mao, H. K.↗

Residual strain gradient determination in metal matrix composites by synchrotron X-ray energy dispersive diffraction

An X-ray technique for the measurement of internal residual strain gradients near the continuous reinforcements of metal matrix composites has been investigated. The technique utilizes high intensity white X-ray radiation from a synchrotron radiation source to obtain energy spectra from small (0.001 cu mm) volumes deep within composite samples. The viability of the technique was tested using a model system with 800 micron Al203 fibers and a commercial purity titanium matrix. Good agreement was observed between the measured residual radial and hoop strain gradients and those estimated from a simple elastic concentric cylinders model. The technique was then used to assess the strains near (SCS-6) silicon carbide fibers in a Ti-14Al-21Nb matrix after consolidation processing. Reasonable agreement between measured and calculated strains was seen provided the probe volume was located 50 microns or more from the fiber/matrix interface.

Kuntz, Todd A.↗

Polarized Resonant Soft X-ray Scattering (P-RSoXS) as a New Technique for Characterizing Amorphous Astromaterials

In the coming years, samples will be returned from several asteroids, the lunar surface, and the first material returned directly from the Martian surface. Previous in-situ and remote studies indicate these samples will contain abundant amorphous or weakly crystalline materials. However, detailed characterization and quantification of these amorphous materials remains challenging. Conventional techniques, including electron microscopy and X-ray diffraction, provide important information on material structure, but are generally limited to crystalline materials. Polarized resonant soft X-ray scattering (P-RSoXS) is a synchrotron-based X-ray scattering technique that has been used to characterize and quantify weakly crystalline systems, including soft materials. This research aims to translate this technique to geologic and extraterrestrial materials, building off the knowledge of using P-RSoXS to interrogate soft materials. P-RSoXS is well-suited to interrogate geologic materials, which are often multiphase, heterogeneous systems with crystalline and amorphous components, and domain sizes on the order of tens of nanometers. It is anticipated that future work will help reveal new chemical and structural information in geologic materials. Maturation of this preliminary work to develop P-RSoXS to characterize astromaterial-relevant samples will provide new understanding of the secondary processes responsible for the development of amorphous astromaterials and further elucidate our knowledge of the geologic history and past alteration processes.

Joshua H Litofsky↗

X-ray diffraction from high pressure Ge using synchrotron radiation

The high pressure structural phase transition in Ge has been studied using the energy dispersive X-ray diffraction technique and a synchrotron radiation source. Ge was observed to transform to the beta-Sn tetragonal structure in agreement with the earlier results of Jamieson, but the phase transition began at 80 + or - 5 kilobars, a somewhat lower value than generally reported. These experimental diffraction results are compared with the recent self-consistent pseudopotential calculations of Yin and Cohen (1981) and with the observed transition pressure for shock wave loaded Ge.

Baublitz, M., Jr.↗

Experiments with phase transitions at very high pressure

Diamond cells were constructed for use to 1 Mbar. A refrigerator for cooling diamond cells was adapted for studies between 15 and 300 K. A cryostat for superconductivity studies between 1.5 to 300 K was constructed. Optical equipment was constructed for fluorescence, transmission, and reflectance studies. X-ray equipment was adapted for use with diamond cells. Experimental techniques were developed for X-ray diffraction studies using synchrotron radiation. AC susceptibility techniques were developed for detecting superconducting transitions. The following materials were studied: compressed solidified gases (Xe, Ar), semiconductors (Ge, Si, GaAs), superconductors (Nb3Ge, Nb3Si, Nb3As, CuCl), molecular crystals (I).

Spain, I. L.↗

The metrology of spherical shells using synchrotron x ray microtomography

With recent advances in solid state imaging technology and the increasing availability of synchrotron x-ray radiation sources, synchrotron x-ray microtomography is emerging as a nondestructive technique for the evaluation of the structure and composition of small specimens with spatial resolution in the micron range. Synchrotron radiation offers the following advantages over conventional x-ray sources: high brightness, continuous emission which is tunable over a large energy range, faster data collection rates, and a highly collimated beam of large cross section permitting the illumination of large specimens. Synchrotron x-ray microtomography enables the structure of individual spheres to be evaluated in order to reveal the concentricity and sphericity of the internal void and the uniformity of the shell wall in the case of high quality spherical shells for Sandia National Laboratories' Inertial Confinement Fusion project.

Hmelo, Anthony B.↗

Limits on the Doppler factor in relativistic jets by means of gamma-ray observations

A new, simple and potentially useful method for constraining the kinematical parameters of relativistic jets based on gamma ray spectral measurements of Active Galaxies is presented. The application of this method to the Quasar 3C273 leads to a value of the Doppler factor of 3 to 4. This corresponds to jet parameters of mu 2 and theta 15 deg in good agreement with the values estimated independently from radio observations of superluminal motion. For the particular case of 3C273, the results are also compared to those given by a similar technique based on the comparison of the X-ray observational data with the synchrotron self Compton prediction from radio measurements. The application of the proposed technique to a significant sample of active galaxies as a result of future gamma ray surveys of the sky is briefly discussed, particularly with respect to possible ways to constrain the cosmological constants H sub o and q sub o.

Dean, A. J.↗

Multielement analysis of interplanetary dust particles using TOF-SIMS

Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

Stephan, T.↗

Crystal structure and density of helium to 232 kbar

The properties of helium and hydrogen at high pressure are topics of great interest to the understanding of planetary interiors. These materials constitute 95 percent of the entire solar system. A technique was presented for the measurement of X-ray diffraction from single-crystals of low-Z condenses gases in a diamond-anvil cell at high pressure. The first such single-crystal X-ray diffraction measurements on solid hydrogen to 26.5 GPa were presented. The application of this technique to the problem of the crystal structure, equation of state, and phase diagram of solid helium is reported. Crucial for X-ray diffraction studies of these materials is the use of a synchrotron radiation source which provides high brillance, narrow collimation of the incident and diffracted X-ray beams to reduce the background noise, and energy-dispersive diffraction techniques with polychromatic (white) radiation, which provides high detection efficiency.

Mao, H. K.↗

Center for the development of commercial crystal growth in space

The second year of operation of the Center for Commercial Crystal Growth in Space is described. This center is a consortium of businesses, universities and national laboratories. The primary goal of the Center's research is the development of commercial crystal growth in space. A secondary goal is to develop scientific understanding and technology which will improve commercial crystal growth on earth. In order to achieve these goals the Center's research is organized into teams by growth technique; melt growth, solution growth, and vapor growth. The melt growth team is working on solidification and characterization of bulk crystals of gallium arsenide and cadmium telluride. They used high resolution X-ray topography performed at the National Synchrotron Light Source at Brookhaven National Laboratory. Streak-like features were found in the diffraction images of semi-insulating undoped LEC GaAs. These were shown to be (110) antiphase boundaries, which have not been reported before but appear to be pervasive and responsible for features seen via less-sensitive characterization methods. The results on CdTe were not as definitive, but indicate that antiphase boundaries may also be responsible for the double peaks often seen in X-ray rocking curves of this material. A liquid encapsulated melt zone system for GaAs has been assembled and techniques for casting feed rods developed. It was found that scratching the inside of the quartz ampoules with silicon carbide abrasive minimized sticking of the GaAs to the quartz. Twelve floating zone experiments were done.

Wilcox, William R.↗

Optical constants from mirror reflectivities measured at synchrotrons

Improved mirror reflectivity measurement techniques have been introduced to permit more accurate determinations of optical constants delta and beta in the complex index of refraction n = 1 - delta - i(beta) over the energy range 50 to 5000 eV. When the density has been determined by X-ray or other means, one can calculate the real and imaginary parts, f-prime and f-double prime, of the complex atomic scattering factor f = f(o) + f-prime + if-double prime from delta and beta. Preliminary results are given for the Ni LIII edge around 852 eV, and the Au M edge region from 2150 to 3500 eV. Since these are the first experimental evaluations of delta for these element edges, they are compared with appropriate reservations to semiempirical tabulations. There is much potential for this technique applied to synchrotron sources.

Blake, R. L.↗

Ultrapressure materials science

Three active areas of research at ultra pressure are pursued, i.e., diffraction studies with the Cornell High Energy Synchrotron Source (CHESS), band gap and absorption edge effects, indentor-anvil experiments and theory and research to attain higher pressures. The range over which X-ray diffraction data and absorption edge data are obtained is extended to 700 kbars. Using the indentor technique pressures of 2.1 Mbars are obtained. Research results and methods are discussed.

Ruoff, A. L.↗

Nuclear techniques in studies of condensed matter

Nuclear techniques have played an important role in the studies of materials over the past several decades. For example, X-ray diffraction, neutron diffraction, neutron activation, and particle- or photon-induced X-ray emission techniques have been used extensively for the elucidation of structural and compositional details of materials. Several new techniques have been developed recently. Four such techniques are briefly reviewed which have great potential in the study and development of new materials. Of these four, Mossbauer spectroscopy, muon spin rotation, and positron annihilation spectroscopy techniques exploit their great sensitivity to the local atomic environments in the test materials. Interest in synchrotron radiation, on the other hand, stems from its special properties, such as high intensity, high degree of polarization, and high monochromaticity. It is hoped that this brief review will stimulate interest in the exploitation of these newer techniques for the development of improved materials.

Singh, Jag J.↗

Radiometry using synchrotron radiation

It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.

Saloman, E. B.↗

Synchrotron/crystal sample preparation

The Center for Applied Optics (CAO) of the University of Alabama in Huntsville (UAH) prepared this final report entitled 'Synchrotron/Crystal Sample Preparation' in completion of contract NAS8-38609, Delivery Order No. 53. Hughes Danbury Optical Systems (HDOS) is manufacturing the Advanced X-ray Astrophysics Facility (AXAF) mirrors. These thin-walled, grazing incidence, Wolter Type-1 mirrors, varying in diameter from 1.2 to 0.68 meters, must be ground and polished using state-of-the-art techniques in order to prevent undue stress due to damage or the presence of crystals and inclusions. The effect of crystals on the polishing and grinding process must also be understood. This involves coating special samples of Zerodur and measuring the reflectivity of the coatings in a synchrotron system. In order to gain the understanding needed on the effect of the Zerodur crystals by the grinding and polishing process, UAH prepared glass samples by cutting, grinding, etching, and polishing as required to meet specifications for witness bars for synchrotron measurements and for investigations of crystals embedded in Zerodur. UAH then characterized these samples for subsurface damage and surface roughness and figure.

Johnson, R. Barry↗

In situ trace element microanalysis

The use of particle-track-radiography and X-ray- fluorescence techniques in the in situ measurement of trace (less than 1000 ppm) elements in single mineral phases of polished sections is surveyed, and examples of their application to ordinary, carbonaceous and enstatite chondrites are provided. Radiographic methods surveyed include fission-track radiography (for U, Th, and Pu-244), alpha radiography using nuclear reactions (for Li and B), alpha autoradiography (for Bi and Pb), and beta autoradiography (for several elements in synthetic or biological samples). Two X-ray-fluorescence methods are compared: (1) photon-induced X-ray emission (PIXE), and (2) the potential use of synchrotron radiation. The latter is shown to allow much greater sensitivity than current PIXE technology and a much broader range of elements than particle-track radiography: the ppm analysis of 10-micron grains for all elements heavier than Na. These advantages are seen as balancing the high cost of accelerator use.

Burnett, D. S.↗

The x ray reflectivity of the AXAF VETA-I optics

The x-ray reflectivity of the VETA-I optic, the outermost shell of the AXAF x-ray telescope, with a bare Zerodur surface, is measured and compared with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. The data were obtained at the x-ray calibrations facility at Marshall Space Flight Center with an electron impact x-ray source located 528 m from the grazing incidence mirror. The source used photoelectric absorption filters to eliminate bremsstrahlung continuum. The mirror has a diameter of 1.2 m and a focal length of 10 m. The incident and reflected x-ray flux are detected using two proportional counters, one located in the incident beam of x-rays at the entrance aperture of the VETA-I, and the other in the focal plane behind an aperture of variable size. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. We also present a synchrotron reflectivity measurement with high energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample, done at NSLS. We present evidence for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 percent and 10 percent, depending on which model for the surface composition is adopted. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff. We also discuss the approach to the final preflight calibration of the full AXAF flight mirror.

Kellogg, Edwin M.↗

Very high-energy gamma ray astronomy

Recent results in ground-based very high-energy (less than 10 to the eleventh power eV) gamma-ray astronomy are reviewed. The various modes of the atmospheric Cerenkov technique are described, and the importance of cosmic ray rejection methods is stressed. The positive detections (at approximately less than 10 to the 12th power eV) of the Crab pulsar that suggest a very flat spectrum and time-variable pulse phase are discussed. Observations of other pulsars (particularly Vela) suggest that these features may be general. The steady flux upper limits for the Crab Nebula are thus reconsidered, and a new value of the implied (Compton-synchrotron) magnetic field in the Nebula is reported. Evidence that a 4.8-hour modulated effect was detected at E sub gamma is less than 10 to the 12th power eV from Cyg X-3 is strengthened in that the exact period originally proposed agrees well with a recent determination of the X-ray period. The southern sky observations are reviewed, and the significance of the detection of an active galaxy (NGC 5128) is considered for source models and future observations.

Grindlay, J. E.↗