Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

INR-TEM: Robust cavity detection in multifocus TEM images via implicit neural representations

When characterizing materials using transmission electron microscopy (TEM) images, detecting and quantifying small features in microstructures, such as cavities, pose significant challenges. Off-the-shelf object detection models, including YOLOv8, show considerable performance degradation, particularly when images vary in resolution and the objects of interest possess a low percentage of the total image region of interest. In this study, we introduce a novel detection pipeline that incorporates an implicit neural representation (INR)-based detection method, INR-TEM, and two-modality imaging (e.g., under-focused and over-focused images typically acquired during materials characterization) to improve object detection performance. The INR-TEM method incorporates a pixel-wise prediction principle inspired by pixel-wise centerness weighting. INR-TEM demonstrates superior robustness to resolution variability, maintaining high detection accuracy even at low image resolutions compared to YOLOv8. To leverage INR-TEM effectively in real-world two-modality characterization applications, we further integrate a two-stage motion correction pipeline designed explicitly for aligning multifocus TEM images. The alignment process, comprising keypoint (based on scale-invariant feature transform, SIFT) and intensity matching, significantly mitigates the adverse effects of perceived motion-induced image degradation during through-focal TEM imaging, directly enhancing INR-TEM’s detection capability over conventional single-focus images. Our integrated INR-TEM cavity detection framework notably improves performance across various cavity sizes, outperforming off-the-shelf YOLOv8 detections that rely on a single image modality.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ TEM observation of calcium silicate hydrate nanostructure at high temperatures

Fire poses a substantial threat to concrete structures because calcium silicate hydrate (C-S-H) is not thermally stable at high temperatures. Herein, in situ TEM at temperatures from 20 to 800 °C was conducted to study the thermal-induced structural changes in C-S-H. We captured C-S-H shrinks at an average rate of 0.02 μm{sup 2}/{sup o}C upon heating with three stages observed, including induction, constant, and rapid periods. Our observation revealed that an 800 nm pore could be healed during pore structure evolution owing to the reconstruction and deformation among C-S-H blocks. The Ca/Si ratio was dropped at higher temperatures because of the leakage of calcium ions from the C-S-H structure to form CaO precipitates. The temperature-driven phase transformation and degradation were also detected using electron diffraction that C-S-H was transformed into metastable calcium silicate minerals above 800 °C. This work provides insights into the nanoscale transformation of C-S-H at high temperatures.

36 MATERIALS SCIENCE↗

Direct Observation of Tungsten Oxidation Studied by In Situ Environmental TEM

In this study, in situ environmental transmission electron microscopy (ETEM) was applied, for the first time, to investigate the thermal oxidation of a pristine and a self-ion irradiated polycrystalline tungsten, using a MEMS-based gas cell at 500 oC to 900 oC in a 1 bar 2%O2/N2 gas mixture. By tracking the dynamic evolution of the tungsten oxide scale as it initiates, grows, and sublimates during a consecutive thermal oxidation experiment, we observed two distinctive tungsten oxide microstructure – one nanocrystalline o-WO3 scale grown on W{27-1 } and W{1-1 8} and another o-WO3 scale exhibits a novel highly textured nanostructure. While the two oxide microstructures shared a similar thickness of ~200 nm after 40-minute early-stage oxidation, the nanocrystalline scale on the W{27-1 } grew much more rapidly at 800 oC than the highly textured oxide at a higher temperature of 900 oC. This suggests both the microstructure of these tungsten oxide scales as well as their oxidation kinetics are highly sensitive to the tungsten surface orientation, and such correlations also change dynamically in the course of oxidation. We also discuss the tungsten oxidation mechanism, the effects of the TEM foil thickness, and the focused ion beam (FIB) Ga+ damage on in situ ETEM oxidation.

In situ ETEM, Tungsten, Thermal oxidation, Orienta↗

Shape-preserving amorphous-to-crystalline transformation of CaCO3 revealed by in situ TEM

Organisms use inorganic ions and macromolecules to regulate crystallization from amorphous- precursors, endowing natural biominerals with complex morphologies and enhanced properties. The mechanisms by which modifiers enable these shape preserving transformations are poorly understood. We used in situ liquid-phase transmission electron microscopy to follow the evolution from amorphous calcium carbonate to calcite in the presence of additives. A combination of contrast analysis and infrared spectroscopy shows that Mg ions, which are widely present in seawater and biological fluids, alter the transformation pathway in a concentration-dependent manner. The ions bring excess (structural) water into the amorphous bulk so that a direct transformation is triggered by dehydration in the absence of morphological changes. Molecular dynamics simulations suggest Mg-incorporated water induces structural fluctuations, allowing transformation without the need to nucleate a separate crystal. Thus, the obtained calcite retains the original morphology of the amorphous state, biomimetically achieving the morphological control of crystals seen in biominerals

crystallization, biomineralization, calcium carbon↗

A Personal Journey in Nanoscience via Developing and Applying Liquid Phase TEM

Liquid phase TEM has attracted widespread attention in recent years as a groundbreaking tool to address various fundamental problems in nanoscience. It has provided the opportunity to reveal many unseen dynamic phenomena of nanoscale materials in solution processes by direct imaging through liquids with high spatial and temporal resolution. After my earlier work on real-time imaging of the nucleation, growth, and dynamic motion of nanoparticles in liquids by developing high-resolution liquid phase transmission electron microscopy (TEM) down to the sub-nanometer level, I established my own research group at Lawrence Berkeley National Lab in 2010. My group focuses on developing and applying liquid phase TEM to investigate complex systems and reactions. We have studied a set of scientific problems centered on understanding how atomic level heterogeneity and fluctuations at solid-liquid interfaces impact nanoscale materials transformations using advanced liquid phase TEM. This article describes my personal journey in nanoscience, highlighting the main discoveries of my research group using liquid phase TEM as a unique tool. Some perspectives on the impacts of liquid phase TEM and the future opportunities in nanoscience and nanotechnology enabled by liquid phase TEM are also included.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wet-chemical etching of FIB lift-out TEM lamellae for damage-free analysis of 3-D nanostructures

Reducing ion beam damage from the focused ion beam (FIB) during fabrication of cross sections is a well-known challenge for materials characterization, especially cross sectional characterization of nanostructures. To address this, a new method has been developed for cross section fabrication enabling high resolution transmission electron microscopy (TEM) analysis of 3-D nanostructures free of surrounding material and free of damage detectable by TEM analysis. Before FIB processing, nanopillars are encapsulated in a sacrificial oxide which acts as a protective layer during FIB milling. Furthermore, the cross sectional TEM lamella containing the nanopillars is then mounted and thinned with some modifications to conventional FIB sample preparation that provide stability for the lamella during the following wet-chemical dip etch. The wet-chemical etch of the TEM lamella removes the sacrificial oxide layer, freeing the nanopillars from any material that would obscure TEM imaging. Both high resolution TEM and aberration corrected scanning TEM images of Si/SiGe pillars with diameters down to 30 nm demonstrate the successful application of this approach.

3-d nanostructure analysis↗

TEM Approaches for Microstructure-Informed Prediction of Mechanical Properties in Structural Alloys

Predicting the mechanical performance of structural alloys from their evolving microstructure remains a major challenge in materials science, particularly for nuclear structural materials, where irradiation-induced defects span multiple types and length scales and interact through complex mechanisms. The dispersed barrier hardening (DBH) [1] and Friedel–Kroupa–Hirsch (FKH) [2,3] models have been widely used to evaluate the hardening contributions of individual obstacles and to estimate tensile strength from quantified microstructures; however, when multiple size-dependent obstacles coexist and evolve, predicting temperature-dependent tensile strength becomes significantly more complex, and a fully consistent hardening model is still lacking. Transmission electron microscopy (TEM) plays a central role in refining hardening models and enabling predictive assessments of tensile strength evolution by providing quantitative characterization of dislocations, irradiation-induced defects (e.g., dislocation loops and cavities), precipitates, and grain structure (Fig. 1.). These experimentally measured defect densities are incorporated into physically based hardening models with size- and shape- dependent obstacle strengths [4], using root-sum-square superposition for obstacles of comparable strength and linear superposition for dissimilar ones [5]. In addition, recent advances in TEM [6-8], including high-resolution imaging, 4D-STEM strain mapping, EDS/EELS elemental analysis, and flash-polishing-based TEM specimen preparation and extraction-replica methods (Fig. 2), further improve the accuracy of microstructural quantification. By comparison with prior studies as well as our own results, we show that when TEM-derived microstructural information is carefully integrated with physically grounded hardening models, yield strength (or irradiation-induced hardening) measured at room temperature can be predicted with good quantitative agreement across multiple alloy classes. In-situ TEM combined with high-temperature mechanical testing represents an important next step for refining hardening models by directly probing dislocation–obstacle interactions across varying irradiation doses and temperatures [9]. Because the barrier strength factor (α) depends on both temperature and obstacle size, it should not be treated as a constant fitting parameter; rather, it must be explicitly evaluated to achieve physically meaningful predictions of mechanical behaviour at operating temperatures. This presentation therefore discusses why all strengthening contributions (e.g., Peierls stress, solid-solution strengthening, voids, bubbles, dislocation loops, dislocation lines, and grain boundaries) must be considered collectively, why appropriate superposition methods are essential when obstacles possess different barrier strength factors, how hardness measurements can be meaningfully related to tensile properties, and how TEM-derived microstructural information can be systematically incorporated into hardening models. More broadly, it outlines a pathway toward microstructure-informed prediction of mechanical properties and supports the goal of establishing science-based tools for evaluating structural materials in extreme environments [10].

Lin, Yan-Ru [ORNL] (ORCID:0000000339991473)↗

Novel method to control explosive shock sensitivity: A mesoscale study to understand the effect of thermally expandable microsphere (TEM) inclusions in high explosives (HE) microstructure

When the void content and/or void structure of a high explosive (HE) is altered by some means (i.e., bulk heating or mechanical damage), the shock initiation behavior of the material changes. The ability to precisely predict the change in shock sensitivity after an HE has undergone microstructural changes is a crucial capability in multi-scale reactive flow models. Here, we utilize thermally expandable microspheres (TEMs) as a dopant in a polymer bonded explosive (PBX) matrix to alter the shock initiation properties in a controlled fashion. Here, using a mesoscale modeling approach, we evaluated how a single TEM (before and after thermal expansion) behaves under shock compression, as well as how the matrix PBX in the direct vicinity of the TEM is affected. We first examined the effect of an unexpanded TEM in the explosive matrix and found that its presence does not significantly perturb the bulk flow and by extension will not affect bulk sensitivity. Next, we examined the effect of an expanded TEM and found that its presence significantly perturbs the flow via hydrodynamic jetting, which causes a secondary shock wave with a strength that exceeds that of the incident wave. Finally, we showed that this secondary shock interacts with the downstream porosity to ignite a larger fraction of the overall pore volume, commensurate with the secondary shock strength and the affected volume, increasing the global (bulk) shock sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding plasticity in irradiated alloys through TEM in situ compression pillar tests

Depth-sensing transmission electron microscopic (TEM) in situ mechanical testing has become widely utilized for understanding deformation in irradiated materials. Until now, compression pillars have primarily been used to study the elastic properties and yield of irradiated materials. In this study, we utilize TEM in situ compression pillars to investigate plastic deformation in two ion-irradiated alloys: Fe–9% Cr oxide dispersion strengthened (ODS) alloy and nanocrystalline Cu–24% Ta. We develop an algorithm to automate the extraction of instantaneous pillar dimensions from TEM videos, which we use to calculate true stress–strain curves and strain hardening exponents. True stress–strain curves reveal intermitted plastic flow in all specimen conditions. In the Fe–9% Cr ODS, intermitted plastic flow is linked to strain bursts observed in TEM videos. Low strain hardening or strain softening is observed in all specimen conditions. TEM videos link the strain softening in irradiated Fe–9% Cr ODS to dislocation cross-slip, and in Cu–24% Ta to grain boundary sliding.

36 MATERIALS SCIENCE↗

Understanding the Influence of Receptive Field and Network Complexity in Neural Network-Guided TEM Image Analysis

Abstract Trained neural networks are promising tools to analyze the ever-increasing amount of scientific image data, but it is unclear how to best customize these networks for the unique features in transmission electron micrographs. Here, we systematically examine how neural network architecture choices affect how neural networks segment, or pixel-wise separate, crystalline nanoparticles from amorphous background in transmission electron microscopy (TEM) images. We focus on decoupling the influence of receptive field, or the area of the input image that contributes to the output decision, from network complexity, which dictates the number of trainable parameters. For low-resolution TEM images which rely on amplitude contrast to distinguish nanoparticles from background, we find that the receptive field does not significantly influence segmentation performance. On the other hand, for high-resolution TEM images which rely on both amplitude and phase-contrast changes to identify nanoparticles, receptive field is an important parameter for increased performance, especially in images with minimal amplitude contrast. Rather than depending on atom or nanoparticle size, the ideal receptive field seems to be inversely correlated to the degree of nanoparticle contrast in the image. Our results provide insight and guidance as to how to adapt neural networks for applications with TEM datasets.

42 ENGINEERING↗

DefectTrack: a deep learning-based multi-object tracking algorithm for quantitative defect analysis of in-situ TEM videos in real-time

Abstract In-situ irradiation transmission electron microscopy (TEM) offers unique insights into the millisecond-timescale post-cascade process, such as the lifetime and thermal stability of defect clusters, vital to the mechanistic understanding of irradiation damage in nuclear materials. Converting in-situ irradiation TEM video data into meaningful information on defect cluster dynamic properties (e.g., lifetime) has become the major technical bottleneck. Here, we present a solution called the DefectTrack , the first dedicated deep learning-based one-shot multi-object tracking (MOT) model capable of tracking cascade-induced defect clusters in in-situ TEM videos in real-time. DefectTrack has achieved a Multi-Object Tracking Accuracy (MOTA) of 66.43% and a Mostly Tracked (MT) of 67.81% on the test set, which are comparable to state-of-the-art MOT algorithms. We discuss the MOT framework, model selection, training, and evaluation strategies for in-situ TEM applications. Further, we compare the DefectTrack with four human experts in quantifying defect cluster lifetime distributions using statistical tests and discuss the relationship between the material science domain metrics and MOT metrics. Our statistical evaluations on the defect lifetime distribution suggest that the DefectTrack outperforms human experts in accuracy and speed.

42 ENGINEERING↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments

Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.

36 MATERIALS SCIENCE↗

Characterizing Dynamic Structure in Battery Electrodes by Time-Resolved Cryo-TEM

In recent years, cryogenic transmission electron microscopy (cryo-TEM) has enabled high-resolution characterization of sensitive battery materials by minimizing electron beam-induced artifacts and damage. Success of this technique relies on the preparation of thin, rapidly frozen samples, generally by disassembling batteries under inert atmosphere, transferring materials of interest to a TEM grid, and finally plunge freezing into a cryogen. In material degradation studies, this extensive time between electrochemical cycling and cryo-TEM characterization leaves room for structural relaxation, diffusion, and other dynamic processes that make it difficult to precisely correlate the imaged structure with the native structure that evolves during battery cycling or aging. Here, we present a method to integrate battery cycling with fast preparation of electrode samples for cryo-TEM. This enables higher fidelity between the structures characterized and the electrochemical state of interest, which we use to study deformation in silicon nanoparticle anodes for lithium-ion batteries.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Method for Evaluating Irradiation Effects on Flow Stress in Fe-9%Cr ODS Using TEM In Situ Cantilevers

Transmission electron microscopic (TEM) in situ mechanical testing has become a widely utilized tool for simultaneously measuring mechanical properties and understanding fundamental deformation mechanisms in irradiated and nuclear materials. Although tensile and compression specimen geometries are amongst the most common, opportunities remain for investigating alternative geometries that could provide unique insights into the plasticity of irradiated materials. This research demonstrates a new TEM in situ cantilever beam configuration. Cantilevers are produced from as-received and proton irradiated (1 dpa, 500°C) Fe-9%Cr oxide dispersion strengthened (ODS) steel. Flow stress is measured using a TEM in situ depth-sensing mechanical testing holder. A 200 MPa increase in flow stress is measured due to irradiation. Size effects arise when the intrinsic (i.e. microstructural) size approaches the extrinsic (i.e. external dimensions) size and can be described using a power law relationship as a function of the material microstructure and cantilever dimensions.

36 MATERIALS SCIENCE↗