Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A High-resolution TOF Detector _ A Possible Way to Compete with a RICH Detector

Using two identical 64-pixel Burle/Photonis MCP-PMTs to provide start and stop signals, they have achieved a timing resolution of {sigma}{sub Single{_}detector} {approx} 7.2 ps for N{sub pe} {approx} 50 photoelectrons (N{sub pe}) with a laser diode providing a 1 mm spot on the MCP window. The limiting resolution achieved was {sigma}{sub Single{_}detector} {approx} 5.0 ps for N{sub pe} {approx} 180, for which they estimate the MCP-PMT contribution of {sigma}{sub MCP-PMT} {approx} 4.5 ps. The electronics contribution is estimated as {sigma}{sub Electrons} = 3.42 ps. These results suggest that an ultra-high resolution TOF detector may become a reality at future experiments one day.

43 PARTICLE ACCELERATORS↗

High resolution TOF - SIMS depth profiling of nano-film multilayers

We present the results of depth profiling studies conducted using an indigenously developed dual-beam high resolution Time-of-Flight Secondary Ion Mass Spectrometer (TOF-SIMS) on thinfilm W-C-W multilayer structure grown on Si substrate. Opto 8 layers could be clearly identified. Mixing of layers is seen which from analysis using roughness model calculations indicate a mixing thickness of about 2nm that correspond to the escape depth of secondary ions from the sample.

36 MATERIALS SCIENCE↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

Sensitivity estimation in time-of-flight list-mode positron emission tomography

Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

60 APPLIED LIFE SCIENCES↗

Developing a camera-based 3D momentum imaging system capable of 1 Mhits/s

A camera-based three-dimensional (3D) imaging system with a superb time-of-flight (TOF) resolution and multi-hit capability was recently developed for electron/ion imaging [Lee et al. J. Chem. Phys. 141, 221101 (2014)]. In this work, we report further improvement of the event rate of the system by adopting an event-driven camera, Tpx3Cam, for detecting the 2D positions of electrons, while a high-speed digitizer provides highly accurate (~30 ps) TOF information for each event at a rate approaching 1 Mhits/sec.

47 OTHER INSTRUMENTATION↗

Energy distribution of ternary {alpha} particles in spontaneous fission of {sup 252}Cf

The energy distribution of the ternary {alpha} particles in spontaneous fission of {sup 252}Cf was measured. For the first time an energy threshold as low as 1 MeV was reached. The experiment used an array of unshielded silicon detectors measuring energy and time-of-flight (TOF) of ternary particles in coincidence with fission fragments. The TOF resolution of the system was sufficient for clear separation of {sup 6}He and tritons from {sup 4}He. The statistics were adequate to extract the {sup 6}He/{sup 4}He yield ratio. For both {sup 4}He and {sup 6}He, an excess in the yield (as compared to a Gaussian shape) was observed at energies below 9 MeV. The measured ternary {alpha} spectrum was corrected for the distortion induced by the detection geometry covering equatorial particle emission only. The emission angle was found to affect mainly the width of the energy distribution by up to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) Concept

Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features.Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutronspectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, toderive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibratingthe instrument to elemental abundance measurements made for known samples in the laboratory. We describe thePhobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time,it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust SolarElectric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos

Clark, Pamela↗

Overview of Phobos/Deimos Regolith Ion Sample Mission (PRISM) Concept

Far more definitive information on composition is required to resolve the question of origin for the Martian moons Phobos and Deimos. Current infrared spectra of the objects are inconclusive due to the lack of strong diagnostic features. Definitive compositional measurements of Phobos could be obtained using in-situ X-ray, gamma-ray, or neutron spectroscopy or collecting and returning samples to Earth for analysis. We have proposed, in lieu of those methods, to derive Phobos and Deimos compositional data from secondary ion mass spectrometry (SIMS) measurements by calibrating the instrument to elemental abundance measurements made for known samples in the laboratory. We describe the Phobos/Deimos Regolith Ion Sample Mission (PRISM) concept here. PRISM utilizes a high-resolution TOF plasma composition analyzer to make SIMS measurements by observing the sputtered species from various locations of the moons' surfaces. In general, the SIMS technique and ion mass spectrometers complement and expand quadrupole mass spectrometer measurements by collecting ions that have been energized to higher energies, 50-100 eV, and making measurements at very low densities and pressures. Furthermore, because the TOF technique accepts all masses all the time, it obtains continuous measurements and does not require stepping through masses. The instrument would draw less than 10 W and weigh less than 5 kg. The spacecraft, nominally a radiation-hardened 12U CubeSat, would use a low-thrust Solar Electric Propulsion system to send it on a two-year journey to Mars, where it would co-orbit with Deimos and then Phobos at distances as low as 27 km.

Dibraccio, Gina↗

A New Limitation of the Depth Resolution in TOF-SIMS Elemental Profiling: the Influence of a Probing Ion Beam

New data concerning the influence of a probing beam of bismuth ions on the depth resolution in elemental depth profiling by secondary ion mass spectrometry (SIMS) have been obtained on a TOF.SIMS-5 system using the principle of two separate ion beams. It is established that the existing criterion of nondestructive character of the probing beam, on which this principle is based, is insufficient. Additional processes must be taken into account so as to formulate a more adequate criterion. A regime of depth profiling is proposed that allows the depth resolution to be improved at low energies of sputtering ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A W-Geometry Ortho-TOF MS with High Resolution and Up to 100% Duty Cycle for MS/MS

Orthogonal injection time-of-flight (orthoTOF) mass spectrometry (MS) is the most prevalent form of TOFMS, owing to its greater control over incoming ion energy, the ability to correct for aberrations in incoming ion velocity and position, and its ability to provide an entire mass spectrum within a single scan. However, the duty cycle of orthoTOFMS is low compared with scanning analyzers, which can have 100% duty cycle when measuring a single type of ion. Typical duty cycles for orthoTOFMS range from 1% to 30%, depending on instrument geometry. Generally, as instrument resolution increases, duty cycle decreases. Additionally, the greatest duty cycle is achieved for the highest m/z ion recorded in the spectrum, and decreases for all other ions as a function of m/z. In a prior publication [Loboda, A.V.; Chernushevich, I.V. J. Am. Soc. Mass Spectrom. 20, 1342–1348 (20)], a novel trapping/release method for restoring the duty cycle of a V-geometry orthoTOFMS to near 100% (referred to as “Zeno pulsing”) was presented. Here, we apply that method to a W-TOF geometry analyzer with analog detection. Across a m/z range of 100–2000, sensitivity gains of ~5–20 are observed, for total ion currents approaching ~10{sup 7} ions·s{sup −1}. Zeno pulsing, or similar strategies for restoring duty cycle, will continue to be important as instrument resolution in orthoTOFMS is increased through the use of ion mirrors. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution of Maldi-Tof Compared to Whole Genome Sequencing for Identification of Bacillus Species Isolated From Cleanrooms at Nasa Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center maintains cleanrooms to archive extraterrestrial materials returned from space exploration missions. Compared to typical built environments, oligotrophic conditions make these facilities inhospitable to microbes. Despite these controls, bacteria and fungi are regularly cultured from these cleanrooms. In particular, Bacillus sp. are frequently isolated during routine microbial monitoring. Endospores associated with this genus can survive extreme environments, such as cleanrooms. This microbial contamination may affect the integrity of astromaterials.

Microbiology↗

Differential cross section for neutron scattering from {sup 209}Bi at 37 MeV and the weak particle-core coupling

Differential scattering cross-section data have been measured at 43 angles from 11 deg. to 160 deg. for 37-MeV neutrons incident on {sup 209}Bi. The primary motivation for the measurements is to address the scarcity of neutron scattering data above 30 MeV and to improve the accuracy of optical-model predictions at medium neutron energies. The high-statistics measurements were conducted at the China Institute of Atomic Energy using the {sup 3}H(d,n){sup 4}He reaction as the neutron source, a pulsed deuteron beam, and time-of-flight (TOF) techniques. Within the resolution of the TOF spectrometer, the measurements included inelastic scattering components. The sum of elastic and inelastic scattering cross sections was computed in joint optical-model and distorted-wave Born approximation calculations under the assumption of the weak particle-core coupling. The results challenge predictions from well-established spherical optical potentials. Good agreement between data and calculations is achieved at 37 MeV provided that the balance between surface and volume absorption in a recent successful model [A. J. Koning and J. P. Delaroche, Nucl. Phys. A 713, 231 (2003)] is modified, thus suggesting the need for global optical-model improvements at medium neutron energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis↗

Progress on Associated-Particle Imaging Algorithms, 2022

The present work describes progress on developing imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating among critical materials or extracting three-dimensional (3D) geometrical information from single-sided or transmission measurements. The present work is divided into three approaches: 1.Iterative reconstruction of inelastic gamma-ray emissions to perform 3D time-of-flight (TOF) imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution. 2.Decomposition of registered neutron and x-ray radiographs into an assumed material list for each pixel in the image. 3.Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles. Progress for each approach is summarized for fiscal year (FY) 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of In Situ Fine Fraction Aerosol Spectra from 300-700 nm Observed Around the Korean Peninsula During KORUS-OC

In situ aerosol extinction and absorption spectra covering the 300-700 nm range at ≤ 1 nm spectral resolution were measured aboard the R/V Onnuri during the Korea U.S. – Ocean Color (KORUS-OC) cruise around the Korean Peninsula from May 21 through June 3, 2016. Total absorption spectra were obtained from aerosols collected on glass fiber filters and subsequently placed in the center of an integrating sphere (Labsphere DRA-CA-30) attached to a dual beam spectrophotometer (Cary 100 Bio UV-Visible Spectrophotometer, 0.2 nm spectral resolution). Absorption spectra from methanol and deionized water extracts of aerosols collected on Teflon filters were measured in a liquid waveguide capillary cell (World Precision Instruments LWCC- 3100, ~0.4 nm spectral resolution). Extinction spectra were measured with a custom built instrument (SpEx, ~0.8 nm spectral resolution). The measurements were obtained at a height of ~10 m above the sea surface with an inlet that limited the measured aerosols to diameters ≤ 1.3 µm. All four sets of spectra exhibit curvature in log-log space with 2nd order polynomials providing a better fit to the measured spectra than power law fits. The deionized water extracts were also analyzed with an ion chromatograph (Dionex ICS-3000 Ion Chromatography System) and with an aerosol mass spectrometer (Aerodyne Research, Inc. HR-ToF High Resolution Aerosol Mass Spectrometer) to examine chemical composition. These data indicate the optical spectra are sensitive to differing chemical properties of the measured ambient aerosols and suggest differing sources and/or atmospheric processes influence the observed optical signatures. The measured suite of spectra are combined to examine the spectral characteristics of single scattering albedo, as well as to examine the contribution of soluble absorbing chromophores to the total absorption spectra. Additional measurements made during the affiliated Korea U.S. - Air Quality (KORUS-AQ) campaign will be used to provide further insight on the observed spectral characteristics.

Jordan, Carolyn E↗