Single shot spin readout with a cryogenic high-electron-mobility transistor amplifier at sub-Kelvin temperatures

We use a cryogenic high-electron-mobility transistor circuit to amplify the current from a single electron transistor, allowing for demonstration of single shot readout of an electron spin on a single P donor in Si with 100 kHz bandwidth and a signal to noise ratio of ~9. In order to reduce the impact of cable capacitance, the amplifier is located adjacent to the Si sample, at the mixing chamber stage of a dilution refrigerator. For a current gain of ~2.7 x 10 3 the power dissipation of the amplifier is 13 μW, the bandwidth is ~1.3 MHz, and for frequencies above 300 kHz the current noise referred to input is ≤ 70 fA/√Hz. Furthermore, with this amplification scheme, we are able to observe coherent oscillations of a P donor electron spin in isotopically enriched 28 Si with 96% visibility.

1/f noise↗

Sense amplifier with transistor threshold compensation

One embodiment provides, in a sense amplifier for an electronic memory array in which a selected memory cell drives a developing voltage differential according to a logic state of the memory cell, a method to store the logic state. The method includes poising source voltages of first and second transistors at levels offset, respectively, by threshold voltages of the first and second transistors. The method also includes applying the voltage differential between a gate of the first transistor and a gate of the second transistor, the first and second transistors configured to oppose each other in a cross-coupled inverter stage of the sense amplifier.

Sinangil, Mahmut E.↗

Cycling excitation process: An ultra efficient and quiet signal amplification mechanism in semiconductor

Signal amplification, performed by transistor amplifiers with its merit rated by the efficiency and noise characteristics, is ubiquitous in all electronic systems. Because of transistor thermal noise, an intrinsic signal amplification mechanism, impact ionization was sought after to complement the limits of transistor amplifiers. However, due to the high operation voltage (30-200 V typically), low power efficiency, limited scalability, and, above all, rapidly increasing excess noise with amplification factor, impact ionization has been out of favor for most electronic systems except for a few applications such as avalanche photodetectors and single-photon Geiger detectors. Here, we report an internal signal amplification mechanism based on the principle of the phonon-assisted cycling excitation process (CEP). Si devices using this concept show ultrahigh gain, low operation voltage, CMOS compatibility, and, above all, quantum limit noise performance that is 30 times lower than devices using impact ionization. Established on a unique physical effect of attractive properties, CEP-based devices can potentially revolutionize the fields of semiconductor electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithium-ion electrolytic substrates for sub-1V high-performance transition metal dichalcogenide transistors and amplifiers

Electrostatic gating of two-dimensional (2D) materials with ionic liquids (ILs), leading to the accumulation of high surface charge carrier densities, has been often exploited in 2D devices. However, the intrinsic liquid nature of ILs, their sensitivity to humidity, and the stress induced in frozen liquids inhibit ILs from constituting an ideal platform for electrostatic gating. Here we report a lithium-ion solid electrolyte substrate, demonstrating its application in high-performance back-gated n-type MoS 2 and p-type WSe 2 transistors with sub-threshold values approaching the ideal limit of 60 mV/dec and complementary inverter amplifier gain of 34, the highest among comparable amplifiers. Remarkably, these outstanding values were obtained under 1 V power supply. Microscopic studies of the transistor channel using microwave impedance microscopy reveal a homogeneous channel formation, indicative of a smooth interface between the TMD and underlying electrolytic substrate. These results establish lithium-ion substrates as a promising alternative to ILs for advanced thin-film devices.

42 ENGINEERING↗

Current gain above 10 in sub-10 nm base III-Nitride tunneling hot electron transistors with GaN/AlN emitter

We report on a tunneling hot electron transistor amplifier with common-emitter current gain greater than 10 at a collector current density in excess of 40 kA/cm{sup 2}. The use of a wide-bandgap GaN/AlN (111 nm/2.5 nm) emitter was found to greatly improve injection efficiency of the emitter and reduce cold electron leakage. With an ultra-thin (8 nm) base, 93% of the injected hot electrons were collected, enabling a common-emitter current gain up to 14.5. This work improves understanding of the quasi-ballistic hot electron transport and may impact the development of high speed devices based on unipolar hot electron transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A SQUID-based microwave cavity search for dark-matter axions

Axions in the {mu}eV mass range are a plausible cold dark matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. The first result from such an axion search using a superconducting first-stage amplifier (SQUID) is reported. The SQUID amplifier, replacing a conventional GaAs field-effect transistor amplifier, successfully reached axion-photon coupling sensitivity in the band set by present axion models and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current gain in sub-10 nm base GaN tunneling hot electron transistors with AlN emitter barrier

We report on Gallium Nitride-based tunneling hot electron transistor amplifier with common-emitter current gain greater than 1. Small signal current gain up to 5 and dc current gain of 1.3 were attained in common-emitter configuration with collector current density in excess of 50 kA/cm{sup 2}. The use of a combination of 1 nm GaN/3 nm AlN layers as an emitter tunneling barrier was found to improve the energy collimation of the injected electrons. These results represent demonstration of unipolar vertical transistors in the III-nitride system that can potentially lead to higher frequency and power microwave devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SQUID-Based Microwave Cavity Search for Dark-Matter Axions

Axions in the mueV mass range are a plausible cold dark-matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. We report the first result from such an axion search using a superconducting first-stage amplifier (SQUID) replacing a conventional GaAs field-effect transistor amplifier. This experiment excludes KSVZ dark-matter axions with masses between 3.3 mueV and 3.53 mueV and sets the stage for a definitive axion search utilizing near quantum-limited SQUID amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Universal tritium transmitter

At the Savannah River Site and throughout the National Nuclear Security Agency (NNSA) tritium is measured using Ion or Kanne Chambers. Tritium flowing through an Ion Chamber emits beta particles generating current flow proportional to tritium radioactivity. Currents in the 1 x 10{sup -15} A to 1 x 10{sup -6} A are measured. The distance between the Ion Chamber and the electrometer in NNSA facilities can be over 100 feet. Currents greater than a few micro-amperes can be measured with a simple modification. Typical operating voltages of 500 to 1000 Volts and piping designs require that the Ion Chamber be connected to earth ground. This grounding combined with long cable lengths and low currents requires a very specialized preamplifier circuit. In addition, the electrometer must be able to supply 'fail safe' alarm signals which are used to alert personnel of a tritium leak, trigger divert systems preventing tritium releases to the environment and monitor stack emissions as required by the United States federal Government and state governments. Ideally the electrometer would be 'self monitoring'. Self monitoring would reduce the need for constant checks by maintenance personnel. For example at some DOE facilities monthly calibration and alarm checks must be performed to ensure operation. NNSA presently uses commercially available electrometers designed specifically for this critical application. The problems with these commercial units include: ground loops, high background currents, inflexibility and susceptibility to Electromagnetic Interference (EMI) which includes RF and Magnetic fields. Existing commercial electrometers lack the flexibility to accommodate different Ion Chamber designs required by the gas pressure, type of gas and range. Ideally the electrometer could be programmed for any expected gas, range and high voltage output. Commercially available units do not have 'fail safe' self monitoring capability. Electronics used to measure extremely low current must have sufficient time to thermally equilibrate. Amplifiers, transistors, resistors all need time to stabilize before the electrometer circuit will measure accurately in the 10{sup -15} and 10{sup -14} ampere range. Existing electrometers give the user no indication when the unit has stabilized and is acceptable for low level measurements. Savannah River National Laboratory (SRNL) funded through the NNSA Plant Directed Research and Development (PDRD) program, has developed a truly Universal Tritium Transmitter (UTT) capable of solving many known problems with existing commercial electrometers. This UTT pushes the state-of-the-art in electrometer design and incorporates solutions to deficiencies found in commercial electrometers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A strained silicon cold electron bolometer using Schottky contacts

We describe optical characterisation of a strained silicon cold electron bolometer (CEB), operating on a 350 mK stage, designed for absorption of millimetre-wave radiation. The silicon cold electron bolometer utilises Schottky contacts between a superconductor and an n{sup ++} doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to 160 GHz and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of 50% for radiation coupled into the device by the planar antenna and an overall noise equivalent power, referred to absorbed optical power, of 1.1×10{sup −16} W Hz{sup −1/2} when the detector is observing a 300 K source through a 4 K throughput limiting aperture. Even though this optical system is not optimized, we measure a system noise equivalent temperature difference of 6 mK Hz{sup −1/2}. We measure the noise of the device using a cross-correlation of time stream data, measured simultaneously with two junction field-effect transistor amplifiers, with a base correlated noise level of 300 pV Hz{sup −1/2} and find that the total noise is consistent with a combination of photon noise, current shot noise, and electron-phonon thermal noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ~2 m 2 of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

47 OTHER INSTRUMENTATION↗

MilliKelvin HEMT Amplifiers for Low Noise High Bandwidth Measurement of Quantum Devices

We demonstrate ultra-low power cryogenic high electron mobility transistor (HEMT) amplifiers for measurement of quantum devices. The low power consumption (few uWs) allows the amplifier to be located near the device, at the coldest cryostat stage (typically less than 100 mK). Such placement minimizes parasitic capacitance and reduces the impact of environmental noise (e.g. triboelectric noise in cabling), allowing for improvements in measurement gain, bandwidth and noise. We use custom high electron mobility transistors (HEMTs) in GaAs/A1GaAs heterostructures. These HEMTs are known to have excellent performance specifically at mK temperatures, with electron mobilities that can exceed 10 6 cm 2 /Vs, allowing for large gain with low power consumption. Low temperature measurements of custom HEMT amplifiers at T = 4 K show a current sensitivity of 50 pA at 1 MHz bandwidth for 5 mW power dissipation, which is an improvement upon performance of amplifiers using off-the-shelf HEMTs.

47 OTHER INSTRUMENTATION↗

White noise of Nb-based microwave superconducting quantum interference device multiplexers with NbN coplanar resonators for readout of transition edge sensors

White noise of dissipationless microwave radio frequency superconducting quantum interference device (RF-SQUID) multiplexers has been experimentally studied to evaluate their readout performance for transition edge sensor (TES) photon counters ranging from near infrared to gamma ray. The characterization has been carried out at 4 K, first to avoid the low-frequency fluctuations present at around 0.1 K, and second, for a feasibility study of readout operation at 4 K for extended applications. To increase the resonant Q at 4 K and maintain low noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1 × 10{sup 4} ≤ Q ≤ 2 × 10{sup 4} and the square root of spectral density of current noise referred to the SQUID input √S{sub I} = 31 pA/√Hz. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Two-directional readout on the complex plane of the transmission component of scattering matrix S{sub 21} enables us to distinguish the flux noise from noise originating from other sources, such as the cryogenic high electron mobility transistor (HEMT) amplifier. Systematic noise measurements with various microwave readout powers P{sub MR} make it possible to distinguish the contribution of noise sources within the system as follows: (1) The achieved √S{sub I} is dominated by the Nyquist noise from a resistor at 4 K in parallel to the SQUID input coil which is present to prevent microwave leakage to the TES. (2) The next dominant source is either the HEMT-amplifier noise (for small values of P{sub MR}) or the quantization noise due to the resolution of 300-K electronics (for large values of P{sub MR}). By a decrease of these noise levels to a degree that is achievable by current technology, we predict that the microwave RF-SQUID multiplexer can exhibit √S{sub I} ≤ 5 pA/√Hz, i.e., close to √S{sub I} of state-of-the-art DC-SQUID-based multiplexers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A small signal amplifier based on ionic liquid gated black phosphorous field effect transistor

In this article we report an analog small signal amplifier based on semiconducting black phosphorus (BP), the most recent addition to the family of two dimensional crystals. The amplifier, consisting of a BP load resistor and a BP field effect transistor (FET) was integrated on a single flake. The gain of the amplifier was found to be ~9 and it remained undistorted for input signal frequencies up to 15 kHz. In addition, we also report record high ON current of 200 µA/µm at V DD = -0.5V in BP FETs. Our results demonstrates the possibility for the implementation of BP in the future generations of analog devices.

36 MATERIALS SCIENCE↗

‘Soft’ amplifier circuits based on field-effect ionic transistors

Soft materials can be used as the building blocks for electronic devices with extraordinary properties. We introduce a theoretical model for a field-effect transistor in which ions are the gated species instead of electrons. Our model incorporates readily-available soft materials, such as conductive porous membranes and polymer-electrolytes to represent a device that regulates ion currents and can be integrated as a component in larger circuits. By means of Nernst–Planck numerical simulations as well as an analytical description of the steady-state current we find that the responses of the system to various input voltages can be categorized into ohmic, sub-threshold, and active modes. This is fully analogous to what is known for the electronic field-effect transistor (FET). Pivotal FET properties such as the threshold voltage and the transconductance crucially depend on the half-cell redox potentials of the source and drain electrodes as well as on the polyelectrolyte charge density and the gate material work function. We confirm the analogy with the electronic FETs through numerical simulations of elementary amplifier circuits in which we successfully substitute the electronic transistor by an ionic transistor.

42 ENGINEERING↗

Focal Plane Array Low Background Testing (Focal Plane Array Characterization under a Low Background)

Most infra-red (IR) imagers for tactical applications use a direct injection (DI) input amplifier design. Fewer transistors in the unit cell allow the read-out electronic circuit (ROIC) to be minimized. This allows either more room for charge integration capacitors or finer pixel pitches. These ROICs work well at high background irradiance levels. However, at low background irradiance levels photocurrent inject efficiency for a DI unit cell amplifier is reduced. Some models have shown that this efficiency can drastically affect performance under low background conditions. The main benefit for Sandia National Laboratories (SNL) and L-3 Communications Cincinnati Electronics (L-3) was a better understanding of these types of sensors under low background conditions. It also provided the opportunity for an independent analysis of these sensors. The purpose of this project was to measure DI for low light levels under different operating temperatures of the L-3 CE103 a 1280 x 1024 indium antimonide 15 micron pitch detector. Results showed DI efficiency approaches 75% under extremely low light levels. Additionally, measured data didn't conform well to traditional circuit based models indicated that other effects are contributing to DI efficiency. A "spot scanning" PSF measurement was also conducted to measure pixel-to-pixel crosstalk for this array. Spot scanning data showed near ideal performance.

47 OTHER INSTRUMENTATION↗

Towards Quantum-Limited Cryogenic Amplification for Multi-Qubit Platforms

Here we present the development of the building blocks of a Josephson parametric amplifier (JPA), namely the superconducting quantum interference device (SQUID) and the inductive pick-up coil that permits current coupling from a quantum dot into the SQUID. We also discuss our efforts in making depletion mode quantum dots using delta doped GaAs quantum wells. Because quantum dot based spin qubits utilize very low-level (~10 - 100pA), short duration (1ms - 1μs) current signals for state preparation and readout, these systems require close proximity cryogenic amplification to prevent signal corruption. Common amplification methods in these semiconductor quantum dots rely on heterojunction bipolar transistors (HBTs) and high electron mobility transistors (HEMTs) to amplify the readout signal from a single qubit. The state of the art for HBTs and HEMTs produce approximately 10µW of power when operating at high bandwidths. For few-qubit systems this level of heat dissipation is acceptable. However, for scaling up the number of qubits to several hundred or a thousand, the heat load produced in a 1 to 1 amplifier to qubit arrangement would overload the cooling capacity of a common dilution refrigerator, which typically has a cooling power of ~100µW at its base temperature. Josephson parametric amplifiers have been shown to dissipate ~1pW of power with current sensitivies on par with HBTs and HEMTs and with bandwidths 30 times that of HBTs and HEMTs, making them attractive for multi-qubit platforms. In this report we describe in detail the fabrication process flow for developing inductive pick-up coils and the fabrication and measurement of NbTiN and A1/A1Ox/A1 SQUIDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗