Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ta-181”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Cross Section Measurements At The RPI LINAC

Recently, a cold moderator was designed and developed for use at the Rensselaer Polytechnic Institute Linear Accelerator (RPI LINAC). This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by up to a factor of 8 by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Furthermore, following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0005 – 1 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0005 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0005 – 1 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission foil measurements of neutron and proton fluences in the A0015 experiment

Results are given from sets of fission foil detectors (FFD's) (Ta-181, Bi-209, Th-232, U-238) which were included in the A0015 experiment to measure combined proton/neutron fluences. Use has been made of recent FFD high energy proton calibrations for improved accuracy of response. Comparisons of track density measurements have been made with the predictions of environmental modeling based on simple 1-D (slab) geometry. At 1 g/cm(exp 2) (trailing edge) the calculations were approximately 25 percent lower than measurements; at 13 g/cm(exp 2) (Earthside) calculations were more than a factor of 2 lower. A future 3-D modeling of the experiment is needed for a more meaningful comparison. Approximate mission proton doses and neutron dose equivalents were found. At Earthside (13 g/cm(exp 2) the dose was 171 rad and dose equivalent was 82 rem. At the trailing edge (1 g/cm(exp 2) dose was 315 rad and dose equivalent was 33 rem. The proton doses are less than expected from TLD doses by 16 percent and 37 percent, respectively. These differences can be explained by uncertainties in the proton and neutron spectra and in the method used to separate proton and neutron contributions to the measurements.

Frank, A. L.↗

Cautionary Notes on Cosmogenic W-182 and Other Nuclei in Lunar Samples

Leya et al. (2000) showed that neutron capture on Ta-181 results in a production rate of Ta-182 (decays with a half-life of 114 days to W-182) sufficiently high to cause significant shifts in W-182 abundances considering the neutron fluences due to the cosmic ray cascade that were known to occur near the lunar surface. Leya et al. concluded that this cosmogenic production of W-182 may explain the large positive epsilon(sub W-182) values that Lee et al. (1997) had reported in some lunar samples rather than being produced from decay of now extinct Hf-182 (bar tau = 13 x 10(exp 6) yr). If the large range in epsilon(sub W-182) of lunar samples (0 to +11 in whole rock samples) was due to decay of now extinct Hf-182, it would require a very early time of formation and differentiation of the lunar crust-mantle system (with high Hf/W ratios) during the earliest stages of Earth s accretion. This result was both surprising and difficult to understand. The ability to explain these results by a more plausible mechanism is therefore very attractive. In a recent report Lee et al. (2002) showed that there were excesses of W-182 and that epsilon(sub W-182) was correlated with the Ta/W ratios in the mineral phases of individual lunar rock samples. This is in accord with W-182 variations in lunar samples being produced by cosmic-ray induced neutron capture on Ta-182.

Yin, Qingzhu↗

Thermal cross section measurements at the RPI LINAC [Abstract]

Recently, a cold moderator was designed and developed for use at the RPI LINAC. This cold moderator proved to easily and safely couple to an existing neutron producing target, while enhancing neutron flux below 0.02 eV by cooling polyethylene down to 29 K. This cold moderator capability allowed for significantly improved counting statistics below 0.02 eV not previously possible due to a poor signal to background ratio. Additionally, testing was performed to characterize the energy resolution of the new cold moderator system and found the system easily capable of resolving resonances in Ta-181 at 4 and 10 eV, while also clearly resolving the Bragg edges found in Be metal below 0.01 eV. Following the design and development of a cold polyethylene moderator, a series of thermal total cross section measurements were performed for polyethylene, polystyrene, Plexiglas and yttrium hydride in the thermal region. These measurements serve to help validate thermal scattering law (TSL) evaluations in the 0.0006 – 20 eV energy range. For polyethylene and polystyrene, two sets of experiments were performed – one with the Enhanced Thermal Target (ETT) and another with the ETT plus the new cold moderator capability (ETTC). The yttrium hydride and Plexiglas measurements were only performed with the ETTC. The measurements for polyethylene help to validate the data processing methodology when using the ETTC, while extending the measured range of polyethylene down to 0.0007 eV. Two different Plexiglas, Plexiglas G and Plexiglas G-UVT, and two different concentrations of yttrium hydride, H/Y = 1.85 and 1.68, were measured. Overall, all materials had generally good agreement with their ENDF/B-VIII.0 TSL evaluations, though some discrepancies were noticed. In the case of the yttrium hydride, the high energy oscillations in the hydrogen cross section and the low energy Bragg edges in the yttrium cross section were clearly seen. These measurements represent the first total cross section measurements that encompass the entire thermal region from 0.0006 – 3 eV for polystyrene and yttrium hydride.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

181 Ta Evaluation in the Unresolved Resonance Range [Slides]

181 Ta is a refractory metal with several nuclear applications including neutron production targets, reactors, and tools for molten actinides. An updated evaluation of 181 Ta includes new measured data, RRR extended up to 2.5 keV (ENDF/B-8.0 upper range is 330 eV), URR extended to 100 keV (ENDF/B-8.0 upper range is 5 keV), and the consistent merging of URR with fast neutron region (Herman).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗