Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Street-level temperature estimation using graph neural networks: Performance, feature embedding and interpretability

Estimating street-level air temperature is a challenging task due to the highly heterogeneous urban surfaces, canyon-like street morphology, and the diverse physical processes in the built environment. Though pioneering studies have embarked on investigations via data-driven approaches, many questions remain to be answered. Here, in this study, we leveraged an innovative framework and redefined the street-level temperature estimation problem using Graph Neural Networks (GNN) with spatial embedding techniques. The results showed that GNN models are more capable and consistent of estimating street-level temperature among tested locations, benefiting from its unique strength in handling extensive data over unstructured graph topology. In addition, we conducted in-depth analysis of feature importance to enhance the model interpretability. Among the urban features analyzed in this study, the time-variant canopy density and meter-level land use data emerge as crucial factors. Our findings highlight GNN 's high potential in capturing the complex dynamics between urban elements and their impacts on microclimate, thus offering valuable insights for comprehensive urban data collection and urban climate modeling in general. Collectively, this study also contributes to urban planning and policy by providing avenues to enhance city resilience against climate change, thereby advancing the agenda for environmental stewardship and urban sustainability.

54 ENVIRONMENTAL SCIENCES↗

Wildfires Temperature Estimation by Complementary Use of Hyperspectral PRISMA and Thermal (ECOSTRESS & L8)

This paper deals with detection and temperature analysis and of wildfires using PRISMA imagery. Precursore IperSpettrale della Missione Applicativa (Hyperspectral Precursor of the Application Mission, PRISMA) is a new hyperspectral mission by ASI (Agenzia Spaziale Italiana, Italian Space Agency) launched in 2019. This mission provides hyperspectral images with a spectral range of 400–2,500 nm and an average spectral resolution less than 12 nm and a spatial resolution of 30 m/pixel. This study focuses on the wildfire temperature estimation over the Bootleg Fire, US 2021. The analysis starts by considering the Hyperspectral Fire Detection Index (HFDI) which is used to analyze the informative content of the images, along with the analysis of some specific visible, near-infrared and shortwave-infrared bands. This first analysis is used as input to perform a temperature estimation of the areas with active wildfire. Surface temperature is retrieved using PRISMA radiance and a linear mixing model based on two background components (vegetation and burn scar) and two active fire components. PRISMA temperatures are compared with LST (Land Surface Temperature) products from NASA's ECOSTRESS and Landsat 8 which imaged the Bootleg Fire before and after PRISMA. A critical discussion of the results obtained with PRISMA is presented, followed by the advantages and limitation of the proposed approach.

54 ENVIRONMENTAL SCIENCES↗

The Reservoir Temperature Estimator (RTEst): A multicomponent geothermometry tool

The Reservoir Temperature Estimator (RTEst) is a multicomponent geothermometry tool for estimating reservoir geochemical parameters including reservoir temperature, CO 2 fugacity, mass of water lost or gained, and a reaction factor. It estimates these parameters and their associated uncertainties by minimizing an objective function that is the weighted sum of squares of the saturation indices of a user-selected set of minerals believed to be equilibrated with the reservoir fluid. RTEst accomplishes these estimates by combining the geochemical modeling capabilities of The Geochemist’s Workbench® with the optimization/parameter estimation resources of PEST®. An included interface aids the user in selecting plausible mineral phases to comprise the objective function and calculates their weighting factors. The working principles of RTEst are described and its efficacy is illustrated by presenting results of its application to various geothermal fields with known conditions. These examples show RTEst can account for the alteration of ascending reservoir fluid by mineral (calcite) re-equilibration with changes in temperature, reconstruct waters with CO 2 loss, correct for the deficit of water and other volatiles (CO 2,gas , H 2 S gas ) from boiling, and determine the amount of mixing of thermal and non-thermal waters. RTEst can use data with basis species below detection limit, missing, or unreliable either by assuming equilibrium with a controlling mineral (fixed-analyte method) or by treating the analyte concentration as an optimization parameter. The inverse of variance weighting method included in RTEst provides more representative results than either the normalization or unit weighting methods. Finally, the ability of RTEst to calculate reservoir temperatures, gas fugacity, and mixing fractions demonstrates its usefulness as a tool for evaluating geothermal systems.

15 GEOTHERMAL ENERGY↗

Model-based real-time surface heat flux and temperature estimation for the DIII-D tokamak

A control-oriented model for monitoring of wall power flux densities on the DIII-D tokamak has been successfully implemented and validated experimentally. Future reactors will have to withstand severe steady state high heat flux loads on plasma-facing components (PFCs). Due to the difficulty of directly-measuring local heat fluxes on these components, monitoring and protection of PFCs during the plasma discharge can benefit from simplified physics-based real-time (RT) functional models to estimate and guide heat load control. As a first step into the development, a control-oriented model for monitoring of wall power flux densities and temperatures on DIII-D tokamak has been successfully implemented. The paper discusses the experimental demonstration and comparison of the 2-D model-based wall heat flux algorithm on the DIII-Dinner wall limiter (IWL) against infra-red camera heat flux measurements for limited plasma configurations. The paper also reports on the benchmarking of the field line tracing environment, SMITER, developed at ITER organization on DIII-D tokamak against experimental IR diagnostic data and the derivation of the component shaping weighting factors for the 2-D model-based approach. Here, the extension of the model-based approach for surface temperature estimation on the DIII-D IWL is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature estimation in a spatially inhomogeneous flame by diode laser absorption spectroscopy

A two-temperature (2T) model is proposed for estimating the temperature of a spatially inhomogeneous hot zone using single-beam diode laser absorption spectrometry. The proposed algorithm is based on fitting experimental absorption spectra by a linear combination of two database-simulated single-temperature spectra with different temperatures. The model efficiency is experimentally demonstrated when determining the temperature in different flame zones of a Wolfgard – Parker slot burner. The proposed 2T algorithm is used to find the maximum and minimum temperatures in different flame sections, which are compared with local temperatures in the same flame zones measured by the method of coherent anti-Stokes Raman scattering (CARS). It is shown that the maximum temperatures determined by the proposed 2T algorithm are in good agreement with CARS data in flame zones where high-temperature regions prevail. A good agreement between the minimum temperatures obtained by these two methods is also observed for predominantly cold zones. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Close Roof Mounted System Temperature Estimation for Compliance to IEC TS 63126

When photovoltaic modules are installed on rooftops the temperature is dependent on both the geographic location and the mounting configuration. If the mounting structure does not provide sufficient air flow in a hot environment, the 98th percential temperature will exceed 70 degrees C which according to IEC TS 63126 requires higher levels of thermal stability testing. However, a simple there is not a clear way to determe which temperature level is needed for a particular location and system design. In this work we identify a relationship between the gap between the rooftop and a module and propose methods to describe minimum gaps for a given location. Because system designs vary in more ways than just the gap, we show how to determine an effective gap which can be simply applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

IEC 63126↗

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY↗

Failure Analysis of Gas Spray Atomization Crucible Materials

An attempted induction melt for gas spray atomization of a Pd alloy at Savannah River National Laboratory experienced a series of faulty thermocouple readings leading to failure of multiple alumina ceramic components and the loss of the metal charge. The spherical powders are used in research and development efforts for hydrogen storage applications. The failure of the thermocouples led to high operating temperatures exceeding the expected operating temperatures. Estimated temperatures of the liquid metal were established by the comparison of the radio frequency power output and multiple temperature readings and determined to have exceeded the functional temperature range of the alumina components. Failure analyses of the event included characterization of the components using visual observation and X-Ray computed tomography of the frozen ingot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Direct-Use Feasibility Study Temperature-Depth Estimates for West Virginia University, Morgantown, WV

This dataset contains data spreadsheets and figures that summarize the results of a stochastic analysis of temperatures at depth below the West Virginia University campus in Morgantown, WV. These results are extracted from a study by Smith (2019), whose results are included in a GDR submission that provides rasters and shapefiles for the Appalachian Basin states of New York, Pennsylvania, and West Virginia (GDR submission #1182). Uncertainties considered included geologic properties, thermal properties, and uncertainty from geostatistical interpolation of the surface heat flow. A Monte Carlo analysis of these uncertain properties was used to predict temperatures at depth using a 1-D heat conduction model. For the pixel corresponding to West Virginia University, a .csv file containing the 10,000 temperature-depth profiles estimated from a Monte Carlo analysis is provided. Temperatures are provided for depths from 1-5 km in 0.5 km increments. These data are summarized in a figure containing violin plots that illustrates the probability of obtaining certain temperatures at depth for Morgantown.

15 GEOTHERMAL ENERGY↗

Wireless Patch Antenna Characterization for Live Health Monitoring Using Machine Learning

Temperature monitoring in extreme environments, such as coal-fired power plants, was addressed by designing and testing wireless patch antennas for use in machine learning-aided temperature estimation. The sensors were designed to monitor the temperature and health of boiler systems. Wireless interrogation of the sensor was performed using a Vector Network Analyzer (VNA) and a pair of interrogation antennas to capture resonance behavior under varying thermal and spatial conditions with sensitivities ranging from 0.052 to 0.20 $\frac{𝑀𝐻𝑧}{°C}$. Sensor calibration was conducted using a Long Short-Term Memory (LSTM) model, which leveraged temporal patterns to account for hysteresis effects. The calibration method demonstrated improved performance when combined with an LSTM model, achieving up to a 76% improvement in temperature estimation error when compared with Linear Regression (LR). The experiments highlighted an innovative solution for patch antenna-based non-contact temperature measurement, which addresses limitations with conventional methods such as RFID-based systems, infrared, and thermocouples.

20 FOSSIL-FUELED POWER PLANTS↗

Estimating Electron Temperature and Density Using Van Allen Probe Data: Typical Behavior of Energetic Electrons in the Inner Magnetosphere

Abstract The Earth's inner magnetosphere contains multiple electron populations influenced by different factors. The cold electrons of the plasmasphere, warm plasma that contributes to the ring current, and the relativistic plasma of the radiation belts often seem to behave independently. Using omni‐directional flux and energy measurements from the HOPE and Magnetic Electron Ion Spectrometer instruments aboard the Van Allen Probes, we provide a detailed density and temperature description of the inner magnetosphere, offering a comprehensive statistical analysis of the entire Van Allen Probe era. While number density and temperature data at geosynchronous orbit are available, this study focuses on the warm plasma in the inner magnetosphere . Values of density and temperature are extracted by fitting energy and phase space density to obtain the distribution function. The fitted distributions are related to the zeroth and second moments to estimate the number density and temperature. Analysis has indicated that a two Maxwellian fit is sufficient over a wide range of and that there are two independent plasma populations. The more energetic population has a median number density of approximately and a temperature of around 130 keV, with a temperature peak observed between L * = 4 and L * = 4.5. This population is relatively uniform in magnetic local time (MLT). In contrast, the less energetic warm electron population has a median number density of about and a temperature of 7.4 keV. Strong statistical trends in density and temperature across both L * and MLT are presented, along with potential sources driving these variations.

58 GEOSCIENCES↗

Using pyrometry to identify porosity in additively manufactured structures

A method and apparatus for identifying porosity in a structure made by an additive manufacturing process in which a laser is scanned across layers of material to form the structure. Pyrometry data comprising images of the layers acquired during additive manufacturing of the structure is received. The pyrometry data is used to generate temperature data comprising estimated temperatures of points in the layers in the images of the layers. The temperature data is used to identify shapes fit to high temperature areas in the images of the layers. Conditions of the shapes fit to the high temperature areas in the images of the layers are identified. Outlier shapes are identified in the shapes fit to the high temperature areas in the images of the layers using the conditions of the shapes.

Mitchell, John A.↗

Optimal sensor network design for multi-scale, time-varying differential algebraic equation systems: Application to an entrained-flow gasifier refractory brick

An algorithm for optimal sensor network design for multi-scale, time-varying differential algebraic equation systems with non-separable dynamics is presented. As the process is time-varying, an integral normalized posterior error covariance of a multi-scale filter is minimized to obtain the optimal sensor locations. For reducing the computational cost, an adaptive sampling rate approach is considered for the slowly-varying variables. The algorithm is applied to a smart refractory brick with embedded sensors as part of an entrained-flow gasifier. Thermistors and interdigital capacitors are considered as candidate measurement technologies for estimating temperature and slag penetration profile along the gasifier wall. Finally, when the optimal set of sensors obtained from the algorithm is used for estimating temperature and slag penetration profiles in a multi-scale Kalman filter framework, satisfactory estimates are obtained despite high measurement noise and model mismatch.

42 ENGINEERING↗

High-Pressure Apparatus for Monitoring Solid–Liquid Phase Transitions

This work presents a new technique for observing the solid–liquid phase transformations in complex diesel fuel blends and diesel surrogates under high-pressure conditions intended to simulate those occurring in vehicle fuel injectors. A high-pressure apparatus based on a visual identification of freezing and thawing has been designed and built to monitor phase behavior and determine the crystallization temperature of complex fuels to predict wax precipitation. The proposed methodology was validated using pure substances—n-hexadecane (C16H34), cyclohexane (C6H12), and a binary cyclohexane/n-hexadecane mixture—all of which have been well-characterized previously. The crystallization temperatures of these compounds were measured from atmospheric pressure to 400 MPa for temperatures varying from 290 to 363 K and compared to those reported in the literature. The standard error of the estimated temperatures, based on a given pressure, between the experimental data obtained in this work was compared to data in the literature from Domanska et al. This methodology is being extended to investigate the properties of more complex fuel mixtures.

High-Pressure, phase change, diesel, solidificatio↗

Desalinating a Real Hyper-Saline Pre-Treated Produced Water via Direct-Heat Vacuum Membrane Distillation

Membrane distillation (MD) is an emerging thermal desalination technology capable of desalinating waters of any salinity. During typical MD processes, the saline feedwater is heated and acts as the thermal energy carrier; however, temperature polarization (as well as thermal energy loss) contributes to low distillate fluxes, low single-pass water recovery and poor thermal efficiency. An alternative approach is to integrate an extra thermal energy carrier as part of the membrane and/or module assembly, which can channel externally provided heat directly to the membrane-feedwater interface and/or along the feed channel length. This direct-heat delivery has been demonstrated to increase single-pass water recovery and enhance the overall thermal efficiency. We developed a bench-scale direct-heated vacuum MD (DHVMD) process to desalinate pre-treated oil and gas "produced water" with an initial total dissolved solids of 115,500 ppm at a feed temperature ranging between 24 and 32 degrees C. We evaluated both water flux and specific energy consumption (SEC) as a function of water recovery. The system achieved a 50% water recovery without significant scaling, with an average flux >6 kg m-2 hr-1 and a SEC as low as 2,530 kJ kg-1. The major species of mineral scales (i.e., NaCl, CaSO4, and SrSO4) that limited the water recovery to 68% were modeled in terms of thermodynamics and identified by scanning electron microscopy and energy-dispersive X-ray spectroscopy. In addition, we further developed and employed a physics-based process model to estimate temperature, salinity, water transport and energy flows for full-scale vacuum MD and DHVMD modules. Model results show that a direct-heat input rate of 3,600 W can increase single-pass water recovery from 2.1% to 3.1% while lowering the thermal SEC from 7,800 kJ kg-1 to 6,517 kJ kg-1 in an unoptimized module. Finally, the scaling up potential of DHVMD process is briefly discussed.

brine↗