At least 19 records

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Testing of a Miniature Loop Heat Pipe Using a Thermal Electrical Cooler for Temperature Control

This paper describes the design and testing of a miniature LHP having a 7 mm O.D. evaporator with an integral CC. The vapor line and liquid line are made of 1.6mm stainless steel tubing. The evaporator and the CC are connected on the outer surface by a copper strap and a thermoelectric (TEC) is installed on the strap. The TEC is used to control the CC temperature by applying an electrical current for heating or cooling. Tests performed in ambient included start-up, power cycle, sink temperature cycle, and CC temperature control using TEC. The LHP demonstrated very robust operation in all tests where the heat load varied between 0.5W and 1OOW, and the sink temperature varied between 243K and 293K. The heat leak from the evaporator to the CC was extremely small. The TEC was able to control the CC temperature within +/-0.3K under all test conditions, and the required control heater power was less than 1W.

Ku, Jentung↗

A Low Cost Thermal Control Method for Testing in a Mars Environment

Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.

MOMA↗

Two-Arm Flexible Thermal Strap

Airborne and space infrared cameras require highly flexible direct cooling of mechanically-sensitive focal planes. A thermal electric cooler is often used together with a thermal strap as a means to transport the thermal energy removed from the infrared detector. While effective, traditional thermal straps are only truly flexible in one direction. In this scenario, a cooling solution must be highly conductive, lightweight, able to operate within a vacuum, and highly flexible in all axes to accommodate adjustment of the focal plane while transmitting minimal force. A two-armed thermal strap using three end pieces and a twisted section offers enhanced elastic movement, significantly beyond the motion permitted by existing thermal straps. This design innovation allows for large elastic displacements in two planes and moderate elasticity in the third plane. By contrast, a more conventional strap of the same conductance offers less flexibility and asymmetrical elasticity. The two-arm configuration reduces the bending moment of inertia for a given conductance by creating the same cross-sectional area for thermal conduction, but with only half the thickness. This reduction in the thickness has a significant effect on the flexibility since there is a cubic relationship between the thickness and the rigidity or bending moment of inertia. The novelty of the technology lies in the mechanical design and manufacturing of the thermal strap. The enhanced flexibility will facilitate cooling of mechanically sensitive components (example: optical focal planes). This development is a significant contribution to the thermal cooling of optics. It is known to be especially important in the thermal control of optical focal planes due to their highly sensitive alignment requirements and mechanical sensitivity; however, many other applications exist including the cooling of gimbal-mounted components.

Urquiza, Eugenio↗

Miniature Loop Heat Pipe (MLHP) Thermal Management System

The MLHP Thermal Management System consists of a loop heat pipe (LHP) with multiple evaporators and condensers, thermal electrical coolers, and deployable radiators coated with variable emittance coatings (VECs). All components are miniaturized. It retains all the performance characteristics of state-of-the-art LHPs and offers additional advantages to enhance the functionality, versatility, and reliability of the system, including flexible locations of instruments and radiators, a single interface temperature for multiple instruments, cooling the on instruments and warming the off instruments simultaneously, improving. start-up success, maintaining a constant LHP operating temperature over a wide range of instrument powers, effecting automatic thermal switching and thermal diode actions, and reducing supplemental heater powers. It can fully achieve low mass, low power and compactness necessary for future small spacecraft. Potential applications of the MLHP thermal technology for future missions include: 1) Magnetospheric Constellation; 2) Solar Sentinels; 3) Mars Science Laboratory; 4) Mars Scouts; 5) Mars Telecom Orbiter; 6) Space Interferometry Mission; 7) Laser Interferometer Space Antenna; 8) Jupiter Icy Moon Orbiter; 9) Terrestrial Planet Finder; 10) Single Aperture Far-Infrared Observatory, and 11) Exploration Missions. The MLHP Thermal Management System combines the operating features of a variable conductance heat pipe, a thermal switch, a thermal diode, and a state-of-the-art LHP into a single integrated thermal system. It offers many advantages over conventional thermal control techniques, and can be a technology enabler for future space missions. Successful flight validation will bring the benefits of MLHP technology to the small satellite arena and will have cross-cutting applications to both Space Science and Earth Science Enterprises.

Ku, Jentung↗

ENG 572 Interim Report

Sandia National Laboratories is a Federally Funded Research and Development Center (FFRDC) founded in 1949 with the mission of developing and testing the non-nuclear components of nuclear weapons. Sandia has since been involved with numerous projects to support the Department of Defense’s (DOE) National Nuclear Security Administration (NNSA). One such set of projects has been implementing over-the-road transportation security enhancements. Under this program, Sandia National Laboratories (SNL) has worked to develop interface compatibility modifications for existing shipping configurations. This summer I will be working with a line of trailers that have been used to transport high asset cargo. These vehicles have successfully traveled millions of miles without any accidents over the course of 15 years. The primary motivation for the work that I will complete this summer is to provide support for existing electronic communication technologies implemented at SNL. As part of an ongoing project to implement modifications to a trailer system, I will focus primarily on the characterization and testing of thermal electric coolers (TEC). Within the scope of the trailer project, these devices provide temperature control for lasers used on optical communication boards (OCB).

42 ENGINEERING↗

WF/PC internal molecular contamination during system thermal-vacuum test

During the recent system thermal vacuum test of the Wide-Field/Planetary Camera (WF/PC), instrumentation was added to the WF/PC to characterize the internal molecular contamination and verify the instrument throughput down to 1470 angstroms. Analysis of data elements revealed two contaminants affecting the far-ultraviolet (FUV) performance of the WF/PC. The one contaminant (heavy volatile) is correlated with the electronic and housing temperature, and the contamination is significantly reduced when the electronics are operated below plus 8 degrees to plus 10 degrees C. The other contaminant (light volatile) is controlled by the heat pipe temperature, and the contamination is significantly reduced when the Thermal Electric Cooler (TEC) hot-junction temperature is below minus 40 degrees to minus 50 degrees C. The utility of contamination sensors located behind instruments during system tests was demonstrated.

Taylor, Daniel M.↗

High-Reliability Pump Module for Non-Planar Ring Oscillator Laser

We propose and have demonstrated a prototype high-reliability pump module for pumping a Non-Planar Ring Oscillator (NPRO) laser suitable for space missions. The pump module consists of multiple fiber-coupled single-mode laser diodes and a fiber array micro-lens array based fiber combiner. The reported Single-Mode laser diode combiner laser pump module (LPM) provides a higher normalized brightness at the combined beam than multimode laser diode based LPMs. A higher brightness from the pump source is essential for efficient NPRO laser pumping and leads to higher reliability because higher efficiency requires a lower operating power for the laser diodes, which in turn increases the reliability and lifetime of the laser diodes. Single-mode laser diodes with Fiber Bragg Grating (FBG) stabilized wavelength permit the pump module to be operated without a thermal electric cooler (TEC) and this further improves the overall reliability of the pump module. The single-mode laser diode LPM is scalable in terms of the number of pump diodes and is capable of combining hundreds of fiber-coupled laser diodes. In the proof-of-concept demonstration, an e-beam written diffractive micro lens array, a custom fiber array, commercial 808nm single mode laser diodes, and a custom NPRO laser head are used. The reliability of the proposed LPM is discussed.

micro lens array↗

What Reliability Engineers Should Know about Space Radiation Effects

Space radiation in space systems present unique failure modes and considerations for reliability engineers. Radiation effects is not a one size fits all field. Threat conditions that must be addressed for a given mission depend on the mission orbital profile, the technologies of parts used in critical functions and on application considerations, such as supply voltages, temperature, duty cycle, and redundancy. In general, the threats that must be addressed are of two types-the cumulative degradation mechanisms of total ionizing dose (TID) and displacement damage (DD). and the prompt responses of components to ionizing particles (protons and heavy ions) falling under the heading of single-event effects. Generally degradation mechanisms behave like wear-out mechanisms on any active components in a system: Total Ionizing Dose (TID) and Displacement Damage: (1) TID affects all active devices over time. Devices can fail either because of parametric shifts that prevent the device from fulfilling its application or due to device failures where the device stops functioning altogether. Since this failure mode varies from part to part and lot to lot, lot qualification testing with sufficient statistics is vital. Displacement damage failures are caused by the displacement of semiconductor atoms from their lattice positions. As with TID, failures can be either parametric or catastrophic, although parametric degradation is more common for displacement damage. Lot testing is critical not just to assure proper device fi.mctionality throughout the mission. It can also suggest remediation strategies when a device fails. This paper will look at these effects on a variety of devices in a variety of applications. This paper will look at these effects on a variety of devices in a variety of applications. (2) On the NEAR mission a functional failure was traced to a PIN diode failure caused by TID induced high leakage currents. NEAR was able to recover from the failure by reversing the current of a nearby Thermal Electric Cooler (turning the TEC into a heater). The elevated temperature caused the PIN diode to anneal and the device to recover. It was by lot qualification testing that NEAR knew the diode would recover when annealed. This paper will look at these effects on a variety of devices in a variety of applications. Single Event Effects (SEE): (1) In contrast to TID and displacement damage, Single Event Effects (SEE) resemble random failures. SEE modes can range from changes in device logic (single-event upset, or SEU). temporary disturbances (single-event transient) to catastrophic effects such as the destructive SEE modes, single-event latchup (SEL). single-event gate rupture (SEGR) and single-event burnout (SEB) (2) The consequences of nondestructive SEE modes such as SEU and SET depend critically on their application--and may range from trivial nuisance errors to catastrophic loss of mission. It is critical not just to ensure that potentially susceptible devices are well characterized for their susceptibility, but also to work with design engineers to understand the implications of each error mode. -For destructive SEE, the predominant risk mitigation strategy is to avoid susceptible parts, or if that is not possible. to avoid conditions under which the part may be susceptible. Destructive SEE mechanisms are often not well understood, and testing is slow and expensive, making rate prediction very challenging. (3) Because the consequences of radiation failure and degradation modes depend so critically on the application as well as the component technology, it is essential that radiation, component. design and system engineers work togetherpreferably starting early in the program to ensure critical applications are addressed in time to optimize the probability of mission success.

DiBari, Rebecca↗

Runtime localized cooling of high-performance processors

A plurality of thermal electric cooler (TEC) elements are formed in a TEC grid structure. Control logic dynamically varies a supply current supplied to each TEC element (or group of TEC elements) in the TEC grid based on changes in power density respectively associated with areas cooled by each of the TEC elements or group of TEC elements.

Rao, Karthik↗

Development of a Thermo-Electric Cooler Simulation Routine for the Wide Field Camera 3 Thermal Model

A SINDA subroutine has been developed to predict the power generated by a Thermo-Electric Cooler (TEC). A TEC can be described analytically by relations between four parameters: cold side temperature, hot side temperature, parasitic heat load, and electrical power. The subroutine requires the user to input the hot side and cold side temperatures, the corresponding parasitic heat load, and coefficients describing the vendor performance curves. The subroutine then utilizes an iterative solution scheme and vendor TEC performance curves for specific hardware to determine the current (and consequently the TEC power) that satisfies these requirements. This paper provides an in-depth discussion of the algorithm employed in the subroutine, implementation of the subroutine in the HST Wide Field Camera 3 thermal model, and the evaluation of the subroutine performance against actual test/correlation data.

Peabody, Hume↗

High thermal power density heat transfer

Heat from a high temperature heat pipe is transferred through a vacuum or a gap filled with electrically nonconducting gas to a cooler heat pipe. The heat pipe is used to cool the nuclear reactor while the heat pipe is connected thermally and electrically to a thermionic converter. If the receiver requires greater thermal power density, geometries are used with larger heat pipe areas for transmitting and receiving energy than the area for conducting the heat to the thermionic converter. In this way the heat pipe capability for increasing thermal power densities compensates for the comparatively low thermal power densities through the electrically non-conducting gap between the two heat pipes.

Morris, J. F.↗

High thermal power density heat transfer apparatus providing electrical isolation at high temperature using heat pipes

This invention is directed to transferring heat from an extremely high temperature source to an electrically isolated lower temperature receiver. The invention is particularly concerned with supplying thermal power to a thermionic converter from a nuclear reactor with electric isolation. Heat from a high temperature heat pipe is transferred through a vacuum or a gap filled with electrically nonconducting gas to a cooler heat pipe. If the receiver requires gratr thermal power density, geometries are used with larger heat pipe areas for transmitting and receiving energy than the area for conducting the heat to the thermionic converter. In this way the heat pipe capability for increasing thermal power densities compensates for the comparative low thermal power densities through the electrically nonconducting gap between the two heat pipes.

Morris, J. F.↗

Thermal Performance of the Texas Instruments 1-W Linear Drive Cryocooler

The efficiency, of the electronics plays a large part in determining the overall spacecraft power requirements to operate the cooler as well as determining the thermal dissipation characteristics of the various electrical components. The results of all the performance measurements are presented in the paper.

linear drive cryocooler temperature thermal dissip↗

HEPP - A low temperature Heat Pipe Experiment Package developed for flight on-board the Long Duration Exposure Facility /LDEF/

The Heat Pipe Experiment Package (HEPP) is designed to provide a flight evaluation system for low temperature heat pipes. The HEPP will be flown aboard the Long Duration Exposure Facility which will be launched and retrieved as part of the Space Shuttle program. The experiment contains two heat pipes: an axially grooved fixed conductance heat pipe and a liquid blockage thermal diode. A phase change material canister is also integrated with a radiant cooler system. Additional hardware consists of supporting electrical equipment, including electronics for signal conditioning and command functions, a data recorder, and a hermetically sealed battery which powers the experiment. A thermal model was developed to simulate the behavior of the HEPP and a ground test program was conducted to verify the predicted performance of the equipment.

Suelau, H. J.↗

A technique to measure the thermal diffusivity of high Tc superconductors

High T(sub c) superconducting electrical current leads and ground straps will be used in cryogenic coolers in future NASA Goddard Space Flight Center missions. These superconducting samples are long, thin leads with a typical diameter of two millimeters. A longitudinal method is developed to measure the thermal diffusivity of candidate materials for this application. This technique uses a peltier junction to supply an oscillatory heat wave into one end of a sample and will use low mass thermocouples to follow the heat wave along the sample. The thermal diffusivity is calculated using both the exponential decay of the heat wave and the phase shift to the wave. Measurements are performed in a cryostat between 10 K and room temperature.

Powers, Charles E.↗

The Zero Boil-Off Tank Experiment Ground Testing and Verification of Fluid and Thermal Performance

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale International Space Station (ISS) experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the work that has been done to demonstrate that the ZBOT experiment is capable of performing the functions required to produce a meaningful and accurate results, prior to its launch to the International Space Station. Main systems discussed are expected to include the thermal control system, the optical imaging system, and the tank filling system.This work is sponsored by NASAs Human Exploration Mission Directorates Physical Sciences Research program.

Fluid management↗

A technique to measure the thermal diffusivity of high T(sub c) superconductors

High T(sub c) superconducting electrical current leads and ground straps will be used in cryogenic coolers in future NASA Goddard Space Flight Center missions. These superconducting samples will be long, thin leads with a typical diameter of two millimeters. A longitudinal method is being developed to measure the thermal diffusivity of candidate materials for this application. This technique will use a peltier junction to supply an oscillatory heat wave into one end of a sample and will use low mass thermocouples to follow the heat wave along the sample. The thermal diffusivity will be calculated using both the exponential decay of the heat wave and the phase shift of the wave. Measurements will be done in a cryostat between 10 K and room temperature.

Powers, Charles E.↗