ENG 572 Interim Report

Sandia National Laboratories is a Federally Funded Research and Development Center (FFRDC) founded in 1949 with the mission of developing and testing the non-nuclear components of nuclear weapons. Sandia has since been involved with numerous projects to support the Department of Defense’s (DOE) National Nuclear Security Administration (NNSA). One such set of projects has been implementing over-the-road transportation security enhancements. Under this program, Sandia National Laboratories (SNL) has worked to develop interface compatibility modifications for existing shipping configurations. This summer I will be working with a line of trailers that have been used to transport high asset cargo. These vehicles have successfully traveled millions of miles without any accidents over the course of 15 years. The primary motivation for the work that I will complete this summer is to provide support for existing electronic communication technologies implemented at SNL. As part of an ongoing project to implement modifications to a trailer system, I will focus primarily on the characterization and testing of thermal electric coolers (TEC). Within the scope of the trailer project, these devices provide temperature control for lasers used on optical communication boards (OCB).

42 ENGINEERING↗

Runtime localized cooling of high-performance processors

A plurality of thermal electric cooler (TEC) elements are formed in a TEC grid structure. Control logic dynamically varies a supply current supplied to each TEC element (or group of TEC elements) in the TEC grid based on changes in power density respectively associated with areas cooled by each of the TEC elements or group of TEC elements.

Rao, Karthik↗

Increasing Main Cooler Thermal Performance for sCO2 Power Cycles

Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For mixed mean temperatures away from the pseudocritical temperature, the heat transfer coefficient matched the Dittus-Boelter correlation. As the mixed mean temperature approached the pseudocritical temperature, the heat transfer coefficient deviated from the Dittus-Boelter correlation due to transverse property variation and buoyancy. The local and average heat transfer coefficients for angled rib tubes were nominally 150% to 300% greater than the heat transfer coefficients for the smooth tube. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.

Searle, Matthew↗

Increasing Main Cooler Thermal Performance for sCO2 Power Cycles

Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For the present study, the measured Nusselt number was 30% less than the Dittus-Boelter correlation. The decrease was attributed to heat transfer degradation. The cooler performance was also reported as heat exchanger effectiveness. A factor of two improvement in Nusselt number (94%) relative to smooth conventional tubes was observed, indicating that heat transfer enhancement features (such as the ribs) are a suitable technology to overcome heat transfer degradation in sCO2 coolers. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.

Searle, Matthew↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

3D printed carbon fiber reinforced carbon as an energy efficient alternative to graphite for EFAS tooling

As Electric Field Assisted Sintering (EFAS) gains more industrial acceptance and use, it becomes more important to develop more efficient means to implement this technology. To this aim, 3D printed continuous carbon fiber reinforced carbon (CCC) was manufactured and fabricated into tooling for EFAS systems as an alternative to traditional graphite tooling. The impact of fiber orientation on the thermal and electrical properties of the CCC was characterized. Sample material was sintered in Tokai G535 graphite tooling, under common processing conditions and compared with CCC tooling. There was nearly 50 % energy savings compared to graphite while maintaining equivalent sample density and microstructure plus keeping ram temperatures 39 % cooler. This is due to spatial control of generated heat and thermal diffusivity within the molds, by means of fiber orientation anisotropy. Finite element modeling of the tooling design supported the experimental results as well as displays the effect of optimization of this 3D printed CCC material.

36 MATERIALS SCIENCE↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Enhancing the cooling performance of thermocouples: a power-constrained topology optimization procedure

Abstract Heat pumping through thermoelectric devices has many advantages over traditional cooling. However, their current efficiency is a limiting factor in their implementation. In this paper, we approach the non-convex topology optimization of thermoelectrical elements for cooling applications through the method of moving asymptotes (MMA) to improve their cooling capabilities per watt usage. The optimization problem is defined for a given power budget, aiming for the minimum temperature with a known heat pumping need. The introduction of power as a constraint justifies the introduction of the voltage gradient across the thermocouple as a design variable to maintain the thermoelectrical device in its optimum power-to-heat extraction ratio. To better understand the convergence of this non-convex problem, we present a two-variable analytical thermoelectric optimization model. This example provides information on how to select the penalty parameters used to scale the three material coefficients involved in the problem to obtain lower objective values and better convergence using MMA. The analytical model shows the non-convexity of the problem and provides the recommendation to use penalization coefficients of the form $$p_k=p_{\sigma }>p_{\alpha }=1$$ p k = p σ > p α = 1 for the thermal conductivity, electrical conductivity, and Seebeck coefficients. We tested these penalization coefficients through optimizations of a model based on the 1MC10-031 commercial thermoelectric-cooler (TEC) using the finite element method (FEM). These penalization coefficients provided local minima without the need for volume constraints. With this procedure, we found designs that provided temperatures close to 10 degrees lower using 60% less semiconductor material volume compared to the initial design.

Gutiérrez, G. Reales↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Transparent window film with embedded nano-shades for thermoregulation

Every year, more than 20% of the energy consumption in the United States and more than 10% of the global consumption is used towards HVAC (Heating, Ventilating, Air-Conditioning) systems in buildings. Although continued efforts in advancing renewable energy, efficient appliances, and smart building systems are desired, the most critical factors that cause extensive indoor energy consumption are thermal leakage and thermal waste generation. We demonstrate a smart window film that allows natural lighting with a clear view while blocking oblique incident sunlight to make the building interior cooler without using electricity or generating heat. Building upon the concept of, often overlooked, traditional window shades and privacy window films, we emphasize and elevate the application and impact of using magnetically arranged nanoscale material for energy conservation purpose in buildings. By embedding vertically aligned Ni flakes (VANF) in a polymer matrix film, nanoscale mirror array serve as shades to block the high-angled incident sunlight, blocking approximately 73% of total solar irradiance and bringing down the indoor temperature by 1.92 °C during the daytime in a model house while providing nearly 90% transparency. Global application was simulated by applying the respective solar angle and intensity at selected latitudes, indicating their potential. This passively energy-conserving smart film is a low cost, maintenance free, and simple product for users and easy-to-manufacture product for the industry.

36 MATERIALS SCIENCE↗

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Performance Trade-off in thermoelectric air conditioning system with graded and constant material properties

Thermoelectric (TE) air cooling is a solid-state technology that has the potential to replace conventional vapor compression-based air conditioning. In this paper, we present a detailed system-level modeling for thermoelectric air conditioning system with position-dependent (graded) and constant material properties. Strategies for design optimization of the system are provided in terms of cost-performance trade-off. Realistic convection heat transfer at both sides of the system are taken into account in our modeling. Here, the effects of convection heat transfer coefficients, air flowrate, and thermoelectric material properties are investigated with varying key parameters such as TE leg thickness, module fill factor, and input current. Both constant material properties and graded properties are considered for the TE materials, and they are compared in terms of the degree of cooling, coefficient of performance (COP), and power consumption. For graded materials, we employ one-dimensional finite element methods to solve the coupled electrical and thermal current equations with arbitrary profile of material properties varying with position along the TE legs. We find that graded materials can enhance the degree of cooling, but only at the expense of COP, compared to the case of constant property materials. With constant material properties of ZT = 1 and relatively low electric current, the power consumption of TE coolers can be lower than those of conventional air conditioners at an equivalent cooling capacity. Considering additional advantages such as demand-flexible operation, low noise, and high scalability, thermoelectric cooling could be a competitive technology for future air conditioning applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximal nighttime electrical power generation via optimal radiative cooling

We present a systematic optimization of nighttime thermoelectric power generation system utilizing radiative cooling. We show that an electrical power density >2 W/m 2 , two orders of magnitude higher than the previously reported experimental result, is achievable using existing technologies. This system combines radiative cooling and thermoelectric power generation and operates at night when solar energy harvesting is unavailable. The thermoelectric power generator (TEG) itself covers less than 1 percent of the system footprint area when achieving this optimal power generation, showing economic feasibility. We study the influence of emissivity spectra, thermal convection, thermoelectric figure of merit and the area ratio between the TEG and the radiative cooler on the power generation performance. We optimize the thermal radiation emitter attached to the cold side and propose practical material implementation. The importance of the optimal emitter is elucidated by the gain of 153% in power density compared to regular blackbody emitters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ENG 572 Final Report

Thermo-electric coolers (TECs) provide an essential function in many high-powered applications by diverting heat away from a temperature-sensitive load. This summer I have worked with Sandia National Laboratories in exploring the failure mechanisms behind said devices. I have been tasked with determining a plan of action for two TECs manufactured by two different companies labeled A and B respectively. Prior to my involvement in the project, the former has displayed failures during normal operation within its packaging. The latter was subsequently chosen to resolve these issues. Thermal cycling between the extreme expected operating temperatures (-40°C to 80°C) was applied to 5 unmounted TECAs over a period of 5 hours with 1-hour soaks at each extreme. The unmounted TECBs are currently undergoing the same process, and the task is expected to be completed over the next few weeks. The results of the TECA characterization have indicated no failure has occurred, which indicates that failure will need to be induced through either higher temperature extremes or additional mechanical stress.

47 OTHER INSTRUMENTATION↗