Thompson's Lamp is Dysfunctional
James Thompson envisaged a lamp which would be turned on for 1 minute, off for 1/2 minute, on for 1/4 minute, etc. ad infinitum. He asked whether the lamp would be on or off at the end of 2 minutes.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
James Thompson envisaged a lamp which would be turned on for 1 minute, off for 1/2 minute, on for 1/4 minute, etc. ad infinitum. He asked whether the lamp would be on or off at the end of 2 minutes.
Photochemical studies of oxygen-ozone and carbon dioxide equilibria with bromine UV lamp
Photolysis of carbon dioxide, using 1633 angstrom line of bromine lamp
Radiation equilibria in UV light on air, oxygen, carbon dioxide, etc, analyzed by bromine lamp in connection with studies of planetary atmospheres
This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.
A titanium-matrix-composite (TMC) hat-stiffened panel of 61 cm sq area and 3.175 cm thick was nondestructively tested to 649 C to examine its buckling characteristics. Compressive loads were applied to the panel in a 978.6 kN uniaxial load frame system. High-temperature testing was performed using quartz lamp heating. A single-strain-age force/stiffness buckling prediction technique was developed to predict panel buckling loads. For the monolithic panel, these test predictions correlated within 10 percent with a finite-element buckling analyses performed elsewhere. Comparisons between force/stiffness predictions and analyses for the TMC panel are in progress.
This report documents the fourth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-4), which was held at the National Institute of Standards and Technology (NIST) on 3-10 May 1995. The agenda for SIRREX-4 was established by a consensus reached at the conclusion of SIRREX-3: there should be an emphasis on training and work to foster and encourage uniform use of accepted protocols for calibrating radiometric instruments in the laboratory. The goal was to host the activity in a setting where proper techniques could be discussed and demonstrated. It seemed appealing to split the day between morning lectures and afternoon laboratory exercises or practicals. The former gave the user community a chance to present what was important to them and discuss it with acknowledged experts in radiometry, while the latter presented a unique opportunity for training and evaluation in the presence of these same experts. The five laboratory sessions were concerned with (1) determining the responsivity of a spectroradiometer and the spectral radiance of an unknown integrating sphere source, (2) demonstrating spectral field calibration procedures for an integrating sphere using three different instruments, (3) measuring spectral radiance using the plaque method, (4) setting up and aligning lamp calibration transfer standards using the NIST specifications for irradiance measurements, and (5) characterizing radiometric instruments. In addition to documenting some supplemental studies performed outside the laboratory sessions, this report includes an evaluation of the hardware that has been used during the SIRREX activities plus a critical evaluation of SIRREX objectives.
Analysis of IUE calibration lamp images shows that variation in the temperature of the scientific instrument causes shifts in the location of the spectral format with respect to the reseau grid on the detector and in the location of the reseaux themselves. In high dispersion, a camera head amplifier temperature difference of 6C corresponds to a shift of 4 pixels in the spectral format for LWR and 2 pixels for SWP along the dispersion direction. Shifts perpendicular to the disperson (for the same temperature difference) are less than one pixel for both cameras. In low dispersion spectra, the shifts are similar but orthogonal to those described above with the larger motion lying in the direction perpendicular to the dispersion. In both dispersion modes, the observed shifts are apparently independent of wavelength. In high dispersion, the constant pixel shift mimics a constant velocity error.