Search NASA⌕ Search

SEARCH · Search NASA

Results for “VACUUM EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanical properties of compacted lunar simulant using new vacuum triaxial equipment

Mechanical stress-strain strength properties of Arizona Lunar Simulant (ALS) are investigated by using a newly developed vacuum triaxial device that allows compaction under different initial vacuums and confinements. Influence of vacuum and confinement on compaction, strength and deformation characteristics of compacted material are delineated and discussed.

Desai, Chandra S.↗

Chemistry laboratory safety manual available

Chemistry laboratory safety manual outlines safe practices for handling hazardous chemicals and chemistry laboratory equipment. Included are discussions of chemical hazards relating to fire, health, explosion, safety equipment and procedures for certain laboratory techniques and manipulations involving glassware, vacuum equipment, acids, bases, and volatile solvents.

Elsbrock, R. G.↗

Vibrational Stability of SRF Accelerator Test Facility at Fermilab

Recently developed, the Superconducting Radio Frequency (SRF) Accelerator Test Facilities at Fermilab support the International Linear Collider (ILC), High Intensity Neutrino Source (HINS), a new high intensity injector (Project X) and other future machines. These facilities; Meson Detector Building (MDB) and New Muon Lab (NML) have very different foundations, structures, relative elevations with respect to grade level and surrounding soil composition. Also, there are differences in the operating equipment and their proximity to the primary machine. All the future machines have stringent operational stability requirements. The present study examines both near-field and ambient vibration in order to develop an understanding of the potential contribution of near-field sources (e.g. compressors, ultra-high and standard vacuum equipment, klystrons, modulators, utility fans and pumps) and distant noise sources to the overall system displacements. Facility vibration measurement results and methods of possible isolation from noise sources are presented and discussed.

43 PARTICLE ACCELERATORS↗

A cleanroom in a glovebox

The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use the equipment for creating and characterizing materials, calls for a dramatic reduction in the cost to create and operate such facilities. To this end, we present our cleanroom-in-a-glovebox, a system that allows for the fabrication and characterization of devices in an inert argon atmosphere. Additionally, we demonstrate the ability to perform a wide range of characterization as well as fabrication steps, without the need for a dedicated room, all in an argon environment. Finally, we discuss the custom-built antechamber attached to the back of the glovebox. This antechamber allows the glovebox to interface with ultra-high vacuum equipment such as molecular-beam epitaxy and scanning tunneling microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automatic sample Dewar for MX beam-line

It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of the loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma immersion ion implantation for the efficient surface modification of medical materials

The paper reports on a new method of plasma immersion ion implantation for the surface modification of medical materials using the example of nickel-titanium (NiTi) alloys much used for manufacturing medical implants. The chemical composition and surface properties of NiTi alloys doped with silicon by conventional ion implantation and by the proposed plasma immersion method are compared. It is shown that the new plasma immersion method is more efficient than conventional ion beam treatment and provides Si implantation into NiTi surface layers through a depth of a hundred nanometers at low bias voltages (400 V) and temperatures (≤150°C) of the substrate. The research results suggest that the chemical composition and surface properties of materials required for medicine, e.g., NiTi alloys, can be successfully attained through modification by the proposed method of plasma immersion ion implantation and by other methods based on the proposed vacuum equipment without using any conventional ion beam treatment.

36 MATERIALS SCIENCE↗

Boron Carbide Synthesis in Low-Voltage DC Electric Arc Initiated in Open Air

We describe a method of obtaining ultrafine boron carbide (B{sub 13}C{sub 2}) powder using the effect of a dc electric arc on a mixture of initial reactants containing carbon and boron. A peculiarity of the proposed method is that it can be implemented using arc discharge operating in open air without any vacuum equipment and protective inert gas atmosphere. X-ray diffraction data showed that the synthesized product in the general case contained three crystalline phases: boron carbide (B{sub 13}C{sub 2}), graphite (C), and boron oxide (B{sub 2}O{sub 3}). Electron-microscopic examination showed that the average size of boron carbide particles ranged from ~50 nm to ~2 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Safe, Low-Cost, High Energy-Density, Solid-State Li-Ion Batteries

We developed intrinsically safe, robust, low-cost, high-energy-density solid-state Li-ion batteries, by integrating high conductivity garnet-type solid Li ion electrolytes and several different cathodes in tailored microstructures, fabricated by low-cost supported thin-film ceramic techniques, to overcome the primary technological barriers to next generation battery technology. In this ARPA-E project we employed Li-garnet solid-state electrolytes pioneered by one of the co-investigators (Thangadurai) which has room temperature (RT) conductivity of ~10 -3 S cm -1 . The highly stable garnet SSE allowed the use of S, NMC, and other cathodes with Li metal anodes without stability or flammability concerns. We studied the garnet’s stability when exposed to CO 2 and humidity (with or without an ALD coating) and showed that the material can be processed in ambient air for most steps prior to battery assembly, significantly reducing production costs. We extensively studied and scaled up the synthesis of the powder and explored external suppliers of garnet to determine the best pathway for commercial success. We used low-cost and scalable tapecasting fabrication methods to create porous-dense-porous “trilayer” solid electrolyte microstructures with a ~20 μm separating dense layer, and >70% porosity porous layers to host the electrodes. These scalable multilayer ceramic fabrication techniques, without need for dry rooms or vacuum equipment, also provide for dramatically reduced manufacturing costs. The tailored microstructured electrode supports (scaffold) increased interfacial area ~50x, overcoming the high impedance typical of planar geometry SSLiBs, resulting in record-setting 10 mA/cm 2 lithium cycling in a symmetric cell. We expanded our tapecasting ability and showed tapes >25m in length by the end of the project. We demonstrated the ability to sinter garnet without the use of a garnet powderbed, which could have been a major obstacle and waste of material at scale. At the same time, we expanded the size of our trilayers from coin cells (0.7 cm 2 ) to the full format design (30 cm 2 ). To develop full cells, we demonstrated 250 Wh/kg at room temperature with commercial NMC electrode films in a bilayer configuration. Similarly, we demonstrated 280 Wh/kg trilayer Li-S cells at room temperature with >90% capacity retention over 300 cycles. At 90°C we demonstrated 350 Wh/kg with a Li-S trilayer. The high thermal stability of the garnet electrolyte also enabled extended cycling (400 cycles) of a Li-TiS 2 cell at 150 °C, showcasing the exceptional safety and nonflammability of the solid-state trilayer batteries. Ion Storage Systems has taken this technology and knowledge to produce trilayer garnet electrolytes and is building out facilities to commercialize high performance solid state batteries. ISS has hired a strong staff, identified and communicated with a large number of potential partners, and successfully secured follow-on funding.

25 ENERGY STORAGE↗

Machine protection system for coherent electron cooling experiment

The coherent electron cooling (CeC) experiment employs a 15 MeV electron beam with up to a few milliamperes current which is capable of destroying the vacuum equipment or intercepting beam diagnostics. The high-current beam can be delivered to two different dumps. RF systems include normal conducting and superconducting cavities which also require protection from abnormal conditions. In this paper, we describe in detail the design and operation of the machine protection system for the CeC accelerator.

43 PARTICLE ACCELERATORS↗

Apparatus and method for carbon fiber surface treatment

An apparatus and method for enhancing the surface energy and/or surface chemistry of carbon fibers involves exposing the fibers to direct or indirect contact with atmospheric pressure plasma generated using a background gas containing at least some oxygen or other reactive species. The fiber may be exposed directly to the plasma, provided that the plasma is nonfilamentary, or the fiber may be exposed indirectly through contact with gases exhausting from a plasma discharge maintained in a separate volume. In either case, the process is carried out at or near atmospheric pressure, thereby eliminating the need for vacuum equipment. The process may be further modified by moistening the fibers with selected oxygen-containing liquids before exposure to the plasma.

36 MATERIALS SCIENCE↗

Apparatus and method for carbon fiber surface treatment

An apparatus and method for enhancing the surface energy and/or surface chemistry of carbon fibers involves exposing the fibers to direct or indirect contact with atmospheric pressure plasma generated using a background gas containing at least some oxygen or other reactive species. The fiber may be exposed directly to the plasma, provided that the plasma is nonfilamentary, or the fiber may be exposed indirectly through contact with gases exhausting from a plasma discharge maintained in a separate volume. In either case, the process is carried out at or near atmospheric pressure, thereby eliminating the need for vacuum equipment. The process may be further modified by moistening the fibers with selected oxygen-containing liquids before exposure to the plasma.

36 MATERIALS SCIENCE↗

Special report, cross calibration of JHU test equipment with GSFC vacuum optical bench

Tests were conducted to confirm the validity of the absolute calibrations which have been performed with the Apollo 17 ultraviolet spectrometer (UVS) in the calibration test equipment (CTE) which were constructed for that purpose. To accomplish this the prototype UV spectrometer SN/01 was retrofitted to be substantially identical to the qualification unit and to the two flight units. It was renamed the cross calibration unit (CCU). The instrument was first calibrated in the JHU calibration test equipment (CTE), then installed in the vacuum optical bench (VOB) at Goddard Space Flight Center and calibrated. The following day a second CTE calibration was conducted which provided substantially the same calibration values as were obtained on the first CTE calibration, and showed remarkably close agreement with the VOB calibration values at two of the wavelengths which were studied. The VOB results at the third wavelength (1216 A) indicate the CTE calibration at 1216 A is 15% too low. This apparent discrepancy is discussed and presents a very important result of the cross calibration effort.

Fastie, W. G.↗

Thermal Management of JWST Cryo-Vacuum Test Support Equipment

In 2017, the James Webb Space Telescope (JWST) underwent functional testing and optical metrology verification of the combined Optical Telescope Element and Integrated Science Instrument Module (OTIS) under cryogenic vacuum conditions in Chamber A at the Johnson Space Center. The ground support and test equipment developed and tested over the previous decade to facilitate this test event were crucial elements of its success. Ground systems required for this test fall into several groups, including thermal simulators, mechanical support hardware, telemetry systems, and metrology systems. This paper will provide a summary of these systems, their development challenges, key features, and highlight thermal performance in the cryovac test.

Havey, Keith A., Jr.↗

Bolt torque tests in vacuum

Test equipment and tests to determine effects of vacuum environment on release torque of threaded fasteners

Demorest, K. E.↗