Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating Core Gaps and the Development of Subcomponent Validation Methods for Wind Turbine Blades: Preprint

Core gaps are a common manufacturing defect observed in wind blade composite sandwich constructions, which occur when sheets of core material are not properly butted up against each other in the mold. The aim of this study was to characterize core gaps in composite sandwich constructions at the coupon scale. This was to gain an initial understanding of the defect before developing appropriate methodologies for more complex subcomponents as part of a much broader wind blade structural validation and damage tolerance program. Long beam flexure in 4-point-bending was chosen as the most appropriate loading scenario. Beam specimens were characterized with and without 10 mm core gaps in fiberglass/balsa sandwich beams. The core gaps were characterized with two separate resin systems; a Hexion epoxy and Arkema's Elium resins system (a novel, infusible thermoplastic). Results showed that the Elium beams without the core gaps were had a 15% lower static strength than their epoxy counterparts. The introduction of the core gap to the epoxy beams reduced their static strength by 35%. The Elium beams, however, exhibited negligible strength reductions with the inclusion of the core gap. Overall, this characterization study provided pertinent information with regards to core gaps as a manufacturing defect to allow for continued development of damage tolerance and subcomponent validation methodologies with the inclusion of manufacturing defects.

17 WIND ENERGY↗

Cyber-Informed Engineering Validation Methods and Guidance

Validation is an important step in any systems engineering process to ensure the correct system was made to fulfill stakeholders’ needs, goals, and expectations. In the context of Cyber-Informed Engineering (CIE), validation ensures cyber impact is reduced through implemented design choices and CIE requirements. This document details a process in validating CIE-based design choices relative to their effectiveness at mitigating high consequence events. The document includes a case study to illustrate the CIE validation process. The case study explores the implementation of CIE validation within the engineering lifecycle of a chemical mixing plant.

42 ENGINEERING↗

Method Validation Summary for L16.2 AD-ISO-0015 for ISO-17025 / NFAC Applications

Methods for the analysis of semi-volatile organic compounds are employed at Savannah River National Laboratory (SRNL) for routine and non-routine samples from tank waste, process control, waste acceptance, and a wide array of other process and research samples. A method has been developed by SRNL, based on existing methods for semi-volatile analysis, for the analysis of nitroaromatic high explosives by gas chromatography / mass spectrometry in soils and sediments. Relative to past work performed at SRNL on nitroaromatic explosives, this developed, optimized, and validated method can achieve lower limits of detection and quantitation, greater precision, lower bias, higher linearity, and accuracy across a greater linear range.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Scoping Tests on Alloy 617 Using Notched Specimen Geometry to Validate Methods for Multiaxial Stress Relaxation

In FY 2022, a development effort was initiated at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) to examine the multiaxial stress-relaxation behavior and multiaxial stress-state effect on the creep-fatigue (CF) performance for Alloy 617 at elevated temperatures. This effort supported the development of the design rules in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC), Section III, Division 5. In this work, two types of the notch specimen geometries were designed. An inelastic constitutive model was used to investigate the stress triaxiality and elastic follow-up effects on the notch specimens under CF deformation in the finite element (FE) simulations. The numerical study demonstrated that the stress triaxiality and elastic follow-up caused by the notches both play significant roles in the stress-relaxation behavior. In addition, Alloy 617 CF experiments were designed, and the testing on the notch specimens is ongoing. CF test failure data will be generated on the specimens with notches under various conditions in FY 2023, and the results will be used to validate methods for accounting for the multiaxial stress relaxation effect in the design code.

36 MATERIALS SCIENCE↗

ARCADE Analysis Methods & Validation Pathway

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) provides an automated analysis system which supports risk-informed performance based (RIPB) evaluations of nuclear control systems. Every possible cyber threat which could lead to consequence is identified by simulating the unsafe control action sequences which transform digital harm into physical harm. Eliminating the simulation of complex digital cyber attack chains cuts out unnecessary computational overhead and focuses directly on the physics of cyber-physical attacks. This focus enables designers to make informed decisions which can entirely eliminate categories of cyber threats against advanced reactors through the physical nature of the plant design. This narrowing of cyber threat against nuclear power plants through the physics of the system is intended to make any remaining threat management and cost efficient. This is the goal of the Tiered Cyber Analysis (TCA) outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors. ARCADE has been custom developed to meet the demands of the rigorous analysis required in Tier 1 of the TCA, which forms the foundation of the TCA process. Currently, ARCADE is still under development, but has made significant leaps in capability. A pilot analysis on the opensource Asherah simulator was performed which demonstrated key functionality goals. The next stage of ARCADE development involves improvements to the applications which support the analysis system, and enabling the analysis system to utilize the full suite of unsafe control action simulations. Since the analysis method’s core functions are complete, validation of the analysis method will be started concurrent to the next development stages. The automated analysis ARCADE will provide can radically change the cybersecurity design process for advanced reactors, reducing the cost of security implementation while enhancing cyber resilience. The pathway for ARCADE’s development to this goal has become much clearer. The majority of technical hurdles have been cleared, and the remaining development needs have been solidified. ARCADE is now capable of assisting the advanced reactor design process and directly support advanced reactor industry RIPB practices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

X-ray spectroscopic methods↗

Validating methods for modeling composition gradients in planar shock experiments

An interface is Rayleigh–Taylor (RT) unstable when acceleration pushes a less dense material into a more dense one, and the growth of the instability is governed partly by the Atwood number gradient. Double-shell inertial confinement fusion capsules have a foam spacer layer pushing on an inner capsule composed of a beryllium tamper and high-Z inner shell, and so have RT unstable interfaces that require benchmarking. To this end, the results of a planar shock experiment with beryllium/tungsten targets are presented. One target had the normal bilayer construction of beryllium and tungsten in two distinct layers; the second target had the beryllium grading into tungsten with a quasi-exponential profile, motivated by the potential for reduced RT growth with the gradient profile. Simulations mimic the shock profiles for both targets and match the shock velocity to within 5%. These results validate the ability of our simulations to model double-shell capsules with bilayer or graded layer Be/W inner shells, which are needed to design future experiments at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validating modern methods for impurity analysis in fluoride salts

Salt impurities directly affect degradation of structural materials in molten salt environments, so impurity quantification and analysis of salts is important for the deployment of next generation molten salt nuclear reactors. Despite the importance of moisture and other oxygen containing impurities, reliable methods of measuring these impurities are not well qualified or commonly used. Herein, we present two methods for analysis of oxygen content and one method for analysis of hydrogen content in fluoride salts demonstrated on two batches of LiF-NaF-KF (FLiNaK) salt with differing purity levels. The intentional addition of varying amounts of oxygen and hydrogen to the FLiNaK salt as internal standards produced a linear response using a commercial combustion analysis instrument, and measured amounts were consistent with the standards. Overall, these results indicate the technique is a valid method for measuring oxygen and hydrogen content in fluoride salts. Corrosion studies of 316H in FLiNaK revealed 5 times more mass loss in the salt containing more impurities including hydrogen and transition metals.

36 MATERIALS SCIENCE↗

Lilith: An Enduring Plutonium Critical Assembly [Slides]

A design of an enduring Pu critical assembly has been produced. This is very important to DOE/NNSA missions. This assembly would result in advances/improvements in nuclear data validation, analytical methods validation, dosimetry, reactor kinetics, materials, and more.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Why the US Needs an Enduring Plutonium Critical Assembly

Jezebel (operated from 1954-1977) has been the primary experiment for fast 239 Pu nuclear data validation for the last 70 years. Validation has included not only k eff , but also spectral indicies, Rossi-α, reactivity coefficients, and neutron leakage spectra. While this has been incredibly valuable to the community, there are three major issues. The first issue is that documentation on many of these experiments were lacking, leading to large uncertainties or (even worse) incorrect assumptions. The second issue is that while there have been many advances in research, there is no way to test those new advances today. The last issue is that since the assembly only operated for 23 years (and at time when 30 other critical assemblies were operating at the same facility and nuclear weapons testing was occurring), there were limited opportunities to observe how any system parameters changed as a function of time. Note that this work is not suggesting that a "Jezebel re placement" used for a limited experiment campaign would have great value. A new enduring (100 year target) plutonium (Pu) assembly with simple geometry and low uncertainties, however, would be extremely valuable. Such a capability would have a transformative impact on many research areas including nuclear data validation, analytical methods validation, dosimetry, reactor kinetics, and materials. The need for a new plutonium assembly is not new: it has been in the DOE Nuclear Criticality Safety Program (NCSP) Mission and Vision for over 10 years and was also the top priority established at the 2022 National Criticality Experiments Research Center (NCERC) Futures meeting. This work will discuss how such a new capability would help ensure that the US retains international leadership in plutonium research. Last, a brief overview of Lilith, a project aimed to design a new enduring plutonium assembly for operation at the NCERC will be given.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS) Final Report

The NIH Research Resource for Biomedical AMS was originally funded at Lawrence Livermore National Laboratory in 1999 to develop and apply the technology of accelerator mass spectrometry (AMS) in broad- based biomedical research. The Resource’s niche is to fill needs for ultra high sensitivity quantitation when isotope-labeled agents are used. The Research Resource’s Technology Research and Development (TR&D) efforts will focus on the needs of the biomedical research community in the context of seven Driving Biomedical Projects (DBPs) that will drive the Center’s technical capabilities through three core TR&Ds. We will expand our present capabilities by developing a fully integrated HPLC AMS to increase our capabilities for metabolic measurements, we will develop methods to understand cellular processes and we will develop and validate methods for the application of AMS in human studies, which is a growing area of demand by collaborators and service users. In addition, we will continue to support new and ongoing collaborative and service projects that require the capabilities of the Resource. The Center will continue to train researchers in the use of the AMS capabilities being developed, and the results of all efforts will be widely disseminated to advance progress in biomedical research. Towards these goals, our specific aims are to:1.) Increase the value and information content of AMS measurements by combining molecular speciation with quantitation of defined macromolecular isolates. Specifically, develop and validate methods for macromolecule labeling, characterization and quantitation.2.) Develop and validate methods and strategies to enable AMS to become more broadly used in human studies. Specifically, demonstrate robust methods for conducting pharmacokinetic/pharmacodynamics studies in humans and model systems.3.) Increase the accessibility of AMS to the Biomedical research community and the throughput of AMS through direct coupling to separatory instruments.4.) Provide high throughput 14C BioAMS analysis for collaborative and service clients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗