At least 19 records

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Characterization of MgB2 Superconducting Hot Electron Bolometers

Hot-Electron Bolometer (HEB) mixers have proven to be the best tool for high-resolution spectroscopy at the Terahertz frequencies. However, the current state of the art NbN mixers suffer from a small intermediate frequency (IF) bandwidth as well as a low operating temperature. MgB2 is a promising material for HEB mixer technology in view of its high critical temperature and fast thermal relaxation allowing for a large IF bandwidth. In this work, we have fabricated and characterized thin-film (approximately 15 nanometers) MgB2-based spiral antenna-coupled HEB mixers on SiC substrate. We achieved the IF bandwidth greater than 8 gigahertz at 25 degrees Kelvin and the device noise temperature less than 4000 degrees Kelvin at 9 degrees Kelvin using a 600 gigahertz source. Using temperature dependencies of the radiation power dissipated in the device we have identified the optical loss in the integrated microantenna responsible as a cause of the limited sensitivity of the current mixer devices. From the analysis of the current-voltage (IV) characteristics, we have derived the effective thermal conductance of the mixer device and estimated the required local oscillator power in an optimized device to be approximately 1 microwatts.

Superconducting Devices↗

Imaging analysis of LDEF craters

Two small craters in Al from the Long Duration Exposure Facility (LDEF) experiment tray A11E00F (no. 74, 119 micron diameter and no. 31, 158 micron diameter) were analyzed using Auger electron spectroscopy (AES), time-of-flight secondary ion mass spectroscopy (TOF-SIMS), low voltage scanning electron microscopy (LVSEM), and SEM energy dispersive spectroscopy (EDS). High resolution images and sensitive elemental and molecular analysis were obtained with this combined approach. The result of these analyses are presented.

Radicatidibrozolo, F.↗

Asymmetrical SRAM Cells For Radiation Tests

Features of circuits altered to increase or decrease sensitivity to radiation. State-space analysis used to analyze single-event-upset behavior of memory cell. When voltage on node a is set at one of indicated initial values Vao and then released, voltages on nodes a and b then follow indicated trajectory to final logic "one" or logic "zero" state. Ability to do this important for design of radiation-detecting integrated circuits (deliberately made more sensitive to ionizing radiation) and "radiation-hardened" integrated circuits - those intended to be relatively invulnerable to intense radiation.

Buehler, Martin G.↗

Reconnection voltage as a function of IMF clock angle

Magnetic reconnection between the IMF and the geomagnetic field is thought to play a major role in the transfer of solar wind momentum and energy to the magnetosphere. Both analytic modeling and analysis of geophysical data have shown that this coupling process should be a sensitive function of the clock angle of the IMF. Results are presented from a three-dimensional, MHD, global numerical simulation code for the reconnection voltage between the closed geomagnetic field and the IMF as a function of the IMF clock angle. These results are consistent with a sin(theta/2) functional behavior.

Fedder, J. A.↗

Taguchi methods in electronics: A case study

Total Quality Management (TQM) is becoming more important as a way to improve productivity. One of the technical aspects of TQM is a system called the Taguchi method. This is an optimization method that, with a few precautions, can reduce test effort by an order of magnitude over conventional techniques. The Taguchi method is specifically designed to minimize a product's sensitivity to uncontrollable system disturbances such as aging, temperature, voltage variations, etc., by simultaneously varying both design and disturbance parameters. The analysis produces an optimum set of design parameters. A 3-day class on the Taguchi method was held at the Marshall Space Flight Center (MSFC) in May 1991. A project was needed as a follow-up after the class was over, and the motor controller was selected at that time. Exactly how to proceed was the subject of discussion for some months. It was not clear exactly what to measure, and design kept getting mixed with optimization. There was even some discussion about why the Taguchi method should be used at all.

Kissel, R.↗

Reliability of Radioisotope Stirling Convertor Linear Alternator

Onboard radioisotope power systems being developed and planned for NASA s deep-space missions would require reliable design lifetimes of up to 14 years. Critical components and materials of Stirling convertors have been undergoing extensive testing and evaluation in support of a reliable performance for the specified life span. Of significant importance to the successful development of the Stirling convertor is the design of a lightweight and highly efficient linear alternator. Alternator performance could vary due to small deviations in the permanent magnet properties, operating temperature, and component geometries. Durability prediction and reliability of the alternator may be affected by these deviations from nominal design conditions. Therefore, it is important to evaluate the effect of these uncertainties in predicting the reliability of the linear alternator performance. This paper presents a study in which a reliability-based methodology is used to assess alternator performance. The response surface characterizing the induced open-circuit voltage performance is constructed using 3-D finite element magnetic analysis. Fast probability integration method is used to determine the probability of the desired performance and its sensitivity to the alternator design parameters.

Shah, Ashwin↗

Application of Derivative Spectrometry to the Analysis of Trace Gases

A derivative spectrometer is sensitive to changes in spectral intensity over narrow wavelength internal. Specifically, a second derivative spectrometer senses the curvature of the incident spectral intensity, providing an output voltage signal proportional to the second derivative of intensity with respect to wavelength. When such an instrument is combined with multi-pass White cell, a unique trace gas analyzer results. The analyzer, operating within the middle ultraviolet spectral region, provides a highly amplified derivative spectrum of any molecular narrow band absorption which is used for trace gas identification. The intensity of any peak within a spectrum is proportional to the trace gas concentration. Such an analyzer, utilizing a 20 meter pathlength White cell, is presently being used to automatically monitor ambient air for SO2, NO, NO2, and O3 with minimum detectable concentration limits in the part per billion range.

Hager, Robert N.↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

Numerical Examination of Silicon Avalanche Photodiodes Operated in Charge Storage Mode

The behavior of silicon-based avalanche photodiodes (APD's) operated in the charge storage mode is examined. In the charge storage mode, the diodes are periodically biased to a sub-breakdown voltage and then open-circuited. During this integration period, photo-excited and thermally generated carriers are accumulated within the structure. The dynamics of this accumulation and its effects upon the avalanching of the diode warrants a detailed, fully numerical analysis. The salient features of this investigation include device sensitivity to the input photo-current including the self-quenching effect of the diode and its limitations in sensing low light levels, the dependence of the response on the bulk lifetime and hence on the generation current within the device, the initial gain, transient response, dependence of the device uniformity upon performance, and the quantity of storable charge within the device. To achieve these tasks our device simulator, STEBS-2D, was utilized. A modified current-controlled boundary condition is employed which allows for the simulation of the isolated diode after the initial reset bias has been applied. With this boundary condition, it is possible to establish a steady-state voltage on the ohmic contact and then effectively remove the device from the external circuit while still including effects from surface recombination, trapped surface charge, and leakage current from the read-out electronics.

Parks, Joseph W., Jr.↗

Mass analysis addition to the Differential Ion Flux Probe (DIFP) study

The objective of this study is to develop a technique to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The approach, conducted in conjunction with current MSFC activities, is to extend the capabilities of the Differential Ion Flux Probe (DIFP) to include a high throughput mass measurement that does not require either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This will significantly reduce the complexity and expense of instrument fabrication, testing, and integration of flight hardware compared to classical mass analyzers. The feasibility of the enhanced DIFP has been verified by using breadboard test models in a controlled plasma environment. The ability to manipulate particles through the instrument regardless of incident angle, energy, or ionic component has been amply demonstrated. The energy analysis mode is differential and leads directly to a time-of-flight mass measurement. With the new design, the DIFP will separate multiple ion streams and analyze each stream independently for ion flux intensity, velocity (including direction of motion), mass, and temperature (or energy distribution). In particular, such an instrument will be invaluable on follow-on electrodynamic TSS missions and, possibly, for environmental monitoring on the space station.

Wright, K. H., Jr.↗

Silicon solar cell process development, fabrication and analysis

The fabrication of solar cells from several unconventional silicon materials is described, and cell performance measured and analyzed. Unconventional materials evaluated are edge defined film fed grown (EFG), heat exchanger method (HEM), dendritic web grown, and continuous CZ silicons. Resistivity, current voltage, and spectral sensitivity of the cells were measured. Current voltage was measured under AM0 and AM1 conditions. Maximum conversion efficiencies of cells fabricated from these and other unconventional silicons were compared and test results analyzed. The HEM and continuous CZ silicon were found to be superior to silicon materials considered previously.

Minahan, J. A.↗

Numerical procedure for analyzing Langmuir probe data

A numerical procedure is proposed for analyzing Langmuir probe data in the presence of a two-group plasma containing both primary and Maxwellian electrons. The procedure is known as a least-squares differential-correction technique for determining the unknown coefficients of the governing equation. It is shown that for a given set of input data the results of the analysis are unique and independent of the initial estimate of electron temperature, that convergence is fastest when electron temperature is overestimated, that the results are sensitive to the region of the curve used as input and also to the voltage increment, and that plasma properties determined by the proposed numerical procedure are either consistent with those determined graphically or closer to expected values. With a suitable data acquisition system, the Fortran IV program worked out for this procedure could be used to provide real-time plasma diagnostic information for an operating ion thruster.

Beattie, J. R.↗

Effect of choked flow on terminal characteristics of MPD thrusters

A one-dimensional steady real gas MPD accelerator model based on data for various electrode lengths and anode orifice radii is presented. The model relates the electric field to the boundary conditions in a form that agrees with experiment over parametric variations in current and mass flow. The electric field is sensitive to the formulations and assumptions bound into the analysis, and is useful in the modeling of outflow properties. It is shown that the location of the sonic point in the arc chamber shifts upstream for high current operation, and the relation between terminal voltage and current is demonstrated. Experiments using an anode suggested by the theory yield a thrust efficiency 1.5 times that of the unmodified thruster.

King, D. Q.↗

Assessing the SEU resistance of CMOS latches using alpha-particle sensitive test circuits

The importance of Cosmic Rays on the performance of integrated circuits (IC's) in a space environment is evident in the upset rate of the Tracking and Data Relay Satellite (TDRS) launched in Apr. 1983. This satellite experiences a single-event-upset (SEU) per day which must be corrected from the ground. Such experience caused a redesign of the Galileo spacecraft with SEU resistant IC's. The solution to the SEU problem continues to be important as the complexity of spacecraft grows, the feature size of IC's decreases, and as space systems are designed with circuits fabricated at non-radiation hardened foundries. This paper describes an approach for verifying the susceptibility of CMOS latches to heavy-ion induced state changes. The approach utilizes alpha particles to induce the upsets in test circuits. These test circuits are standard cells that have offset voltages which sensitize the circuits to upsets. These results are then used to calculate the upsetability at operating voltages. In this study results are presented for the alpha particle upset of a six-transistor static random access memory (SRAM) cell. Then a methodology is described for the analysis of a standard-cell inverter latch.

Buehler, M.↗

Process Research of Polycrystalline Silicon Material (PROPSM)

A passivation process (hydrogenation) that will improve the power generation of solar cells fabricated from presently produced, large grain, cast polycrystalline silicon (Semix), a potentially low cost material are developed. The first objective is to verify the operation of a DC plasma hydrogenation system and to investigate the effect of hydrogen on the electrical performance of a variety of polycrystalline silicon solar cells. The second objective is to parameterize and optimize a hydrogenation process for cast polycrystalline silicon, and will include a process sensitivity analysis. The sample preparation for the first phase is outlined. The hydrogenation system is described, and some early results that were obtained using the hydrogenation system without a plasma are summarized. Light beam induced current (LBIC) measurements of minicell samples, and their correlation to dark current voltage characteristics, are discussed.

Culik, J. S.↗