Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wollaston prism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The linear phase correction of modulation of intensity emerging from zero effort (MIEZE) with magnetic Wollaston prisms

This study proposes the use of two magnetic Wollaston prisms (MWPs) to correct for the linear Larmor phase aberration of modulation of intensity emerging from zero effort (MIEZE), introduced by the transverse size of the sample. With this approach, the contrast of the intensity modulation can be maximized at any scattering angle of interest such that the same contrast as the direct transmission geometry can be fully recovered. The optimum magnetic fields required for the MWPs depend only on the scattering angle and the frequencies of the radio-frequency flippers, and they are independent of the neutron wavelength and beam divergence, which makes the approach suitable for both pulsed and continuous neutron sources.

36 MATERIALS SCIENCE↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification and Calibration of Spectroscopy and Polarization modes for the Roman Coronagraph Instrument

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit to a confirmed planet after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm intended to capture key methane absorption features. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another covering 10% bandpasses at 575 and 825nm, but the optics meet performance requirements across the full CGI bandpass. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

Tyler D. Groff↗

RST CGI: Final Verification and Calibration of Prism and Polarizer Flight Units

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit which is deployed to the planet position after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another to completely characterize the instrument polarization effects and recover the Stokes parameters of the targeted disk. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is optimized to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

high contrast imaging↗

WFIRST CGI: Prism and Polarizer Characterization Modes

As part of its technology demonstration, the WFIRST coronagraph instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The specific implementation of spectroscopy is a zero-deviation Amici prism and slit to be placed on the planet after high contrast has been achieved by CGI. The polarization optics are a set of Wollaston prisms so that orthogonal polarization states can be measured simultaneously. The CGI spectral characterization mode, being designed and built and Goddard Space Flight Center (GSFC), has a spectral resolution of R50 and is designed to accommodate a 15% bandpass spanning 610-785nm. In order to recover Stokes information, there are two sets of Wollaston prisms clocked 45 degrees with respect to one another with each measurement taken in series. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is designed to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes and address the challenge of on-orbit spectral calibration for a deployable slit in the presence of pointing drifts. Of unique interest is how the observatory error budget couples into good stellar spectrum calibration and subsequent speckle subtraction. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, modeled performance, and operations concept. These performance metrics are simulated to demonstrate how a slit located at an arbitrary field point is homed onto the planet and converted to a calibrated spectrum.

Tyler D Groff↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-textured neutron beams with orbital angular momentum

In this work, we present a rigorous theoretical framework underpinning the technique of spin-echo modulated small-angle neutron scattering (SEMSANS), and show how the technique can be extended in order to generate spin-textured neutron beams with orbital angular momentum (OAM) via birefringent neutron spin-polarization devices known as magnetic Wollaston prisms. Neutron OAM beams are mathematically characterized by a “cork-screw” phase singularity e iℓΦ about the propagation axis where ℓ is the OAM quantum number. To understand the precise relationship between the emergent OAM state and the variety of spin textures realized by various setups, we have developed a path-integral approach that in the interferometric limit makes a judicious use of magnetic Snell's law. We show that our proposed technique produces a complex two-dimensional pattern of spin-OAM entangled states which may be useful as a probe of quantum magnetic materials. We compare our path-integral approach to the well-known single-path Larmor precession model and present a pedagogical derivation of magnetic Snell's law of refraction for both massive and massless particles based on Maupertuis's action principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photometric intensity and polarization measurements of the solar corona.

Use of a satellite photometric observatory (SPO) to measure the solar corona from Miahuatlan, Mexico during the Mar. 7, 1970, total eclipse of the sun. The SPO is equipped with a 24-in. Cassegrainian telescope, a four-channel photoelectric photometer, a Wollaston prism, and a rotating half-wave plate. Simultaneous measurements were made of the two orthogonal components of coronal light in the B and R bands of the UBVRI system. A 1-minute arc aperture was scanned from the lunar disk center out to five solar radii in a series of spirals of gradually increasing radius. For the first time, simultaneous multicolor intensity, degree, and angle of polarization profiles are computed from photoelectric measurements. Comparison of the variations of the measurements for each spiral scan yield a detailed picture of the intensity and polarization features in the K corona.

Mcdougal, D. S.↗

Circular polarization of twilight.

Review of observations of circular polarization of twilight performed with a polarimeter which uses an electronically switched Pockels cell operated as a reversible quarter-wave plate to convert circular into linear polarization. The latter was then analyzed by a Wollaston prism followed by two gallium-arsenide photomultipliers. The discovery of a definite natural circular polarization at twilight does suggest that, with increased observation precision, measurements of the small daylight component are possible. These could give useful information about particles in the atmosphere and be valuable in studies of meteorology and air pollution.

Angel, J. R. P.↗

Linear polarimeter with rapid modulation, achromatic in the 0.3-1.1-micron range

A polarimeter is described, which provides achromatic modulation over the spectral range 0.3 to 1.1 microns, with very small light losses. The instrument is the first one to use superachromatic half-wave plates; such a plate is made of three achromatic half-wave plates of quartz and magnesium fluoride cemented with the optical axis of the central plate making an angle of 1.00 rad with the axes of the parallel-oriented outer half-wave plates. Wavelength dependence of the axis direction of the optical axis was eliminated by using two identical such plates in front of a Wollaston prism. The plate closer to the prism is stationary, while the other is continuously rotated by a stepper motor. In the polarimeter constructed, the range of instrumentally induced wavelength dependence of the plane of polarization did not exceed 0.002 rad. Using the polarimeter on a 228-cm telescope, a 10-min integration through the blue filter of the UBV photometric system for a star of magnitude 10.0 gives the percentage polarization with a mean error of + or - 0.014%.

Frecker, J. E.↗

Performance of the spectropolarimeter for the Space Telescope faint object spectrograph

The design and preliminary test results for the spectropolarimeter for the Faint Object Spectrograph (FOS) for the Space Telescope are presented. The mechanical design and optical specifications of the spectropolarimeter are described noting that a Wollaston prism with an internal wedge angle of 20 deg is fixed behind each of two rotatable waveplate retarders of different retardations. Either waveplate/prism combination can be positioned at either of the two FOS entrance ports. Magnesium fluoride is chosen as the birefringent crystal for the polarizing elements to allow linear and circular polarization measurements down to Lyman-alpha at 1216 A. Mechanical stability and repeatability were determined by operational testing to give polarization-position angles of + or - 0.5 deg, corresponding to degree-of-polarization measurements of + or - 0.1 percent. Faint-object accuracy, dependent on photoelectron statistics and hence on observation time, is calculated to be one percent in each 100-A-wide spectral band for a 20-min observation of an AO star with V = 15th magnitude.

Allen, R. G.↗

Real-time image difference detection using a polarization rotation spacial light modulator

An image difference detection system is described, of the type wherein two created image representations such as transparencies representing the images to be compared lie coplanar, while light passes through the two transparencies and is formed into coincident images at the image plane for comparison. The two transparencies are formed by portions of a polarization-rotation spatial light modulator display such as a multi-pixel liquid crystal display or a magnetooptical rotation type display. In a system where light passing through the two transparencies is polarized in transverse directions to enable the use of a Wollaston prism to bring the images into coincidence, a liquid crystal display can be used which is devoid of polarizing sheets that would interfere with transverse polarizing of the light passing through the two transparencies.

Chao, Tien-Hsin↗

Galileo Photopolarimeter/Radiometer experiment

The Photopolarimeter/Radiometer (PPR) is a remote sensing instrument on the Galileo Orbiter designed to measure the degree of linear polarization and the intensity of reflected sunlight in ten spectral channels between 410 and 945 nm to determine the physical properties of Jovian clouds and aerosols, and to characterize the texture and microstructure of satellite surfaces. The PPR also measures thermal radiation in five spectral bands between 15 and 100 microns to sense the upper tropospheric temperature structure. Two additional channels which measure spectrally integrated solar and solar plus thermal radiation are used to determine the planetary radiation budget components. The PPR photopolarimetric measurements utilize previously flown technology for high-precision polarimetry using a calcite Wollaston prism and two silicon photodiodes to enable simultaneous detection of the two orthogonal polarization components. The PPR radiometry measurements are made with a lithium tantalate pyroelectric detector utilizing a unique arrangement of radiometric stops and a scene/space chopper blade to enable a warm instrument to sense accurately the much colder scene temperatures.

Russell, E. E.↗

Bubble Dynamics on a Heated Surface

In this work, we study steady and oscillatory thermocapillary and natural convective flows generated by a bubble on a heated solid surface. The interaction between gas and vapor bubbles with the surrounding fluid is of interest for both space and ground-based processing. A combined numerical-experimental approach is adopted here. The temperature field is visualized using Mach-Zehnder and/or Wollaston Prism Interferometry and the flow field is observed by a laser sheet flow visualization technique. A finite element numerical model is developed which solves the transient two-dimensional continuity, momentum, and energy equations and includes the effects of temperature-dependent surface tension and bubble surface deformation. Below the critical Marangoni number, the steady state low-g and 1-g temperature and velocity fields predicted by the finite element model are in excellent agreement with both the visualization experiments in our laboratory and recently published experimental results in the literature. Above the critical Marangoni number, the model predicts an oscillatory flow which is also closely confirmed by experiments. It is shown that the dynamics of the oscillatory flow are directly controlled by the thermal and hydrodynamic interactions brought about by combined natural and thermocapillary convection. Therefore, as numerical simulations show, there are considerable differences between the 1-g and low-g temperature and flow fields at both low and high Marangoni numbers. This has serious implications for both materials processing and fluid management in space.

Kassemi, M.↗

An Astronomical Test of CCD Photometric Precision

Ground-based differential photometry is limited to a precision of order 10(exp -3) because of atmospheric effects. A space-based photometer should be limited only by the inherent instrument precision and shot noise. Laboratory tests have shown that a precision of order 10-5 is achievable with commercially available charged coupled devices (CCDs). We have proposed to take this one step further by performing measurements at a telescope using a Wollaston prism as a beam splitter First-order atmospheric effects (e.g., extinction) will appear to be identical in the two images of each star formed by the prism and will be removed in the data analysis. This arrangement can determine the precision that is achievable under the influence of second-order atmospheric effects (e.g., variable point-spread function (PSF) from seeing). These telescopic observations will thus provide a lower limit to the precision that can be realized by a space-based differential photometer.

Koch, David G.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Real-time image difference detection using a polarization rotation spacial light modulator

An image difference detection system is described, of the type wherein two created image representations such as transparencies representing the images to be compared lie coplanar, while light passes through the two transparencies and is formed into coincident images at the image plane for comparison. The two transparencies are formed by portions of a polarization rotation spacial light modulator display such as a multi-pixel liquid crystal display or a magneto optical rotation type. In a system where light passing through the two transparencies is polarized in transverse directions to enable the use of a Wollaston prism to bring the images into coincidence, a liquid crystal display can be used which is devoid of polarizing sheets that would interfere with transverse polarizing of the light passing through the two transparencies.

Chao, Tien-Hsin↗