Search NASA⌕ Search

SEARCH · Search NASA

Results for “XCT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microstructural characterization of the oxidation of nuclear graphite under chronic and accident conditions via XCT and synchrotron XCT

Graphite is a candidate material to moderate fast neutrons and for structural components in the US next-generation graphite-moderated reactors. A graphite core is conceived as a large formation of interconnected bricks that primarily serves as the moderator of fast neutrons, holds instrumentation, fuel elements, control rods, and is a receptacle for molten salts for Molten Salt Reactors (MSRs) designs. During the operation of a graphite-moderated power plant, graphite components might be subjected to chronic oxidation during normal operating conditions or aggressive oxidation as a result of accidental ingress of air that reacts vigorously with the graphite core. Using synchrotron, x-ray computed tomography (XCT), this research systematically characterized microstructural changes that accompanied these two oxidation scenarios. Chronic oxidation was studied by characterizing IG-110, PCEA, and NBG-18 specimens that were gradually oxidized in air at a low temperature (520°C). The accidental ingress of air into the graphite reactor was simulated by subjecting the grades mentioned above to high-temperature oxidation at approximately 750°C. This research is the first, in situ, systematic characterization of nuclear graphite microstructural evolution that can be associated with the two possible oxidation scenarios and provide insight into related repercussions. The results show that the microstructure and pore connectivity influence the rate of oxidation and evolution of the microstructure under the two oxidation regimes. These results are crucial to understanding which grades are more resilient to each type of oxidation and documenting the damage created in the graphite.

Arregui Mena, Jose'↗

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES↗

Nanopore networks in colloidal silica assemblies characterized by XCT for confined fluid flow modeling

Fluid flow through nanopore structures has exhibited different behavior than that described by Darcy's law, derived from pore networks of micrometer scale. Here, pressure assemblies of colloidal silica spheres of specified diameters from 94 to 620 nanometers were prepared as model nano-porous media. The smaller silica spheres tended to form random packing, but some substantial ordering was found in the packing of the larger silica spheres. X-ray computed tomography (XCT), with a voxel resolution of 16 nm, was used to characterize the nanopore networks. The porosity of the Nano-XCT pore network (34%) was less than the total porosity of the assemblies as determined by X-ray attenuation (52%), possibly due to the limits of voxel resolution during segmentation. Fluid flow in the nanopore networks was simulated using the single-phase Lattice Boltzmann Method, and the simulated permeability was compared with the empirical and experimental values. Based on our characterization, although a well-ordered packing of silica spheres was not achieved, it was found that the nanopore networks in the colloidal silica assemblies had pore size distributions corresponding to the particle sizes. The simulated permeability was less than the experimental measurement for water flow, but the complex packing of silica spheres and surface chemistry issues need to be considered in future research.

02 PETROLEUM↗

Evaluation of XCT for Matrix Density Measurement of Particle Fuel Forms

Particle fuel forms generally consist of a dispersion of fuel, such as tristructural isotropic (TRISO) particles, within a refractory matrix (e.g., graphite or silicon carbide). The density of matrix materials for particle fuel forms is of interest for modeling fuel form strength and thermal properties and may be specified as a quality control parameter, depending on reactor design. Some of the uncertainty associated with traditional, manual approaches can be eliminated by performing x-ray computed tomography (XCT) on the fuel forms and applying image processing methods to generate a precise count of the number of particles. This also removes the need to include determination of particle count within each individual fuel form during fabrication. Unfortunately, reconstruction artifacts from high-Z uranium-bearing kernels prevent accurate measurement of individual particle volumes using this approach, so the use of mean particle mass and volume are still necessary for computation of average fuel form matrix density. This method of using XCT to count particles in individual fuel form for determination of average matrix density was applied to three archived compacts from the Advanced Gas Reactor Fuel Development and Qualification (AGR)-1 campaign, four archived compacts with uranium carbide/uranium oxide (UCO) TRISO from the AGR-2 campaign, and three archived UO 2 -TRISO compacts from the AGR-2 campaign. The resulting density values were compared with those previously reported, showing slight changes due to uncertainties in the previously used number of particles in each of these cylindrical, graphite matrix compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and exterior features, offers scientists a preliminary research tool for targeted sub-sample requests, and additionally is a visually engaging interactive tool for bringing astromaterials science to the public.

Blumenfeld, E. H.↗

Isotopic, Chemical, and Molecular Studies of Insoluble Organic Matter and C-Rich Presolar Grains in Murchison and Sutter'S Mill: Assessing the Impact of XCT and Preparation for Bennu Samples

Spectral observations of B-type asteroid Bennu by the OSIRIS-REx spacecraft show affinities to CM-type carbonaceous chondrites, being organic-rich [1, 2] with abundant hydrated minerals [3-5]. Here we analyzed acid insoluble residues from Bennu analog chondrites Murchison (CM2) and Sutter’s Mill (C) to assess the effects of parent body alteration on the insoluble organic matter (IOM) chemistry and isotopic compositions, as well as abundances of C-rich presolar grains. Because Bennu samples may undergo X-ray computed tomography (XCT) imaging during preliminary examination, it is necessary to understand the effects of irradiation, if any, on IOM. We therefore also analyzed a residue produced from XCT-imaged Murchison powder to assess any X-ray damage.

A. N. Nguyen↗

XCT System for Harvesting In-Current Hydrokinetic Energy from Low-Velocity Sites

The Project demonstrated the functionality of a cross cutting (XCT) type turbine in laboratory and open water testing. The fundamental design approach of locating small axial rotors near the ends of driving spars, which pull the rotors through the water at a multiple of the free-stream velocity eliminates the need (and thus the cost) for a gearbox and torque resisting structures. This configuration, however, introduces the complexity of transmitting electricity across a rotating interface. Even so, cost models indicate that depending on the anchoring and mooring system, LCOE less than $0.10/kWh should be possible in high capacity-factor sites with non-reversing currents.

13 HYDRO ENERGY↗

The Nature of Insoluble Organic Matter in Sutter’s Mill and Murchison Carbonaceous Chondrites: Testing the Effect of X-ray Computed Tomography (XCT) and Exploring Parent Body Organic Molecular Evolution

This study analyzed samples of the Murchison and Sutter’s Mill carbonaceous chondrite meteorites in support of the future analysis of samples returned from the asteroid (10155) Bennu by the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer) mission. Focusing specifically on the insoluble organic matter (IOM), this study establishes that a total of 1.3 g of bulk sample from a single chondritic meteorite is sufficient to obtain a wide range of cosmochemical information, including light element analysis (H, C, and N), isotopic analysis (D/H, 13 C/ 12 C, and 15 N/ 14 N), and X-ray fluorescence spectroscopy for major elemental abundances. IOM isolated from the bulk meteorite samples was analyzed by light element and isotopic analysis as described above, 1 H and 13 C solid-state nuclear magnetic resonance spectroscopy, Raman spectroscopy, and complete noble gas analyses (abundances and isotopes). The samples studied included a pair from Murchison (CM2), one of which had been irradiated with high-energy X-rays in the course of computed tomographic imaging. No differences between the irradiated and non-irradiated Murchison samples were observed in the many different chemical and spectroscopic analyses, indicating that any X-ray–derived sample damage is below levels of detection. Elemental, isotopic, and molecular spectroscopic data derived from IOM isolated from the Sutter’s Mill sample reveals evidence that this meteorite falls into the class of heated CM chondrites.

planetary science↗

Developing a system for in vivo imaging of maize roots containing iodinated contrast media in soil using synchrotron XCT and XRF

We sought to develop a novel experimental system which enabled application of iodinated contrast media to in vivo plant roots intact in soil and was compatible with time-resolved synchrotron X-ray computed tomography imaging. The system was developed to overcome issues of low contrast to noise within X-ray computed tomography images of plant roots and soil environments, the latter of which can complicate image processing and result in the loss of anatomical information. To demonstrate the efficacy of the system we employ the novel use of both synchrotron X-ray computed tomography and synchrotron X-ray fluorescence mapping to capture the translocation of the contrast media through root vasculature into the leaves. With the application of contrast media we identify fluid flow in root vasculature and visualise anatomical features, which are otherwise often only observable in ex vivo microscopy, including: the xylem, metaxylem, pith, fibres in aerenchyma and leaf venation. We are also able to observe interactions between aerenchyma cross sectional area and solute transport in the root vasculature with depth. Our novel system was capable of successfully delivering sufficient contrast media into root and leaf tissues such that anatomical features could be visualised and internal fluid transport observed. We propose that our system could be used in future to study internal plant transport mechanisms and parameterise models for fluid flow in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC): A Payload Designed for Exploration of Terrestrial Planetary Bodies

Geological materials (indeed, all solid objects) are characterized by their crystal structure, elemental composition, and morphology. The Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC) instrument suite quantifies all three. These measurements address fundamental science questions (e.g., the origin and evolution of planetary bodies) and support the human exploration of space (e.g., the characterization of regolith for ISRU and the constraint of its geotechnical properties). METRIC comprises an X-ray Diffraction/X-ray Fluorescence instrument (XRD: mineral structure and XRF: elemental composition), an X-ray micro-Computed Tomography instrument (XCT: 3D internal micromorphology), and a hyperspectral imaging infrared spectrometer (IRS) to provide local/regional mineralogic context for these measurements. METRIC XRD/F draws heritage from the highly successful Mars Science Laboratory CheMin instrument. The METRIC XRD/F employs two separate sample cells, one optimized for XRD and one for XRF, resulting in more rapid XRD analysis (tens of minutes vs. tens of hours for CheMin) and an orders-of-magnitude improvement in XRF detection. XCT has not been deployed in space, so the METRIC XCT represents a new capability for solar system exploration. The XCT uses the same basic high-TRL components as METRIC XRD/F, decreasing its development cost for flight. The METRIC IRS is a derivative of the NASA Earth Science Technology Office funded Hyperspectral Thermal Imager instrument and utilizes the NASA Technology Transfer Program to incorporate a commercial-of-the-shelf infrared camera ruggedized for space by NASA Marshall Space Flight Center. The IRS spectral range (8–14 µm) and resolution (10.8 cm -1 ) are tailored to quantify mineralogy in rocks using their characteristic Reststrahlen bands and to characterize mineralogy of soils using the position of the Christensen Feature. The METRIC payload is currently designed for deployment to the Moon on a Commercial Lunar Payload Services (CLPS) mission, where the XRD/F and XCT would be located on a lander and the IRS would be on deployed on a companion rover to evaluate the mineralogical diversity of the landing site. A pneumatic drill designed by Honeybee Robotics would excavate regolith up to 50 cm below the lander and deliver multiple aliquots of regolith to the XRD/F and XCT. The METRIC payload could also be deployed on a rover. In this case, a sample handling system on a robotic arm could scoop regolith and/or drill rocks and deliver powder to the XRD/F and XCT located in the rover’s interior. Alternatively, METRIC instruments could be used singly or in combination on human space missions. The XRD/F and XCT could be used to characterize samples in a rover or in a science laboratory within a habitat. These data could help astronauts identify resource-enriched rocks and regolith and triage geologic samples to return samples of high interest for analysis in terrestrial laboratories. The IRS could be attached to a human-navigated rover to collect mineralogical data along a traverse and identify high-priority science samples.

E. B. Rampe↗

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Beam Hardening Artifact Reduction in X-Ray CT Reconstruction of 3D Printed Metal Parts Leveraging Deep Learning and CAD Models

Nondestructive evaluation (NDE) of additively manufactured (AM) parts is important for understanding the impacts of various process parameters and qualifying the built part. X-ray computed tomography (XCT) has played a critical role in rapid NDE and characterization of AM parts. However, XCT of metal AM parts can be challenging because of artifacts produced by standard reconstruction algorithms as a result of a confounding effect called “beam hardening.” Beam hardening artifacts complicate the analysis of XCT images and adversely impact the process of detecting defects, such as pores and cracks, which is key to ensuring the quality of the parts being printed. In this work, we propose a novel framework based on using available computer-aided design (CAD) models for parts to be manufactured, accurate XCT simulations, and a deep-neural network to produce high-quality XCT reconstructions from data that are affected by noise and beam hardening. Using extensive experiments with simulated data sets, we demonstrate that our method can significantly improve the reconstruction quality, thereby enabling better detection of defects compared with the state of the art. We also present promising preliminary results of applying the deep networks trained using CAD models to experimental data obtained from XCT of an AM jet-engine turbine blade.

Ziabari, Amir↗

Using X-Ray Computed Tomography to Catalog Rock Fragments in Apollo Drive Tube 73002

Overview: The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Approximately 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center (i.e., never allocated, continuously stored in dry-N2 purged cabinets, exposure history restricted to Teflon, stainless steel, and Al-metal). Although most Apollo samples have been well characterized, there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been cu-rated under special conditions, e.g., frozen samples, samples stored in He-purged environment, and previously unopened drive tubes. NASA solicited proposals for the Apollo Next Generation Sample Analysis Pro-gram (ANGSA), and 9 teams were selected to study a subset of the unopened and frozen samples [1]. The first sample opened as part of the ANGSA pro-gram was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a land-slide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube [3], which provided invaluable information during the dissection process [4]. In addition to the pre-dissection XCT scans, individual >4 mm particles were separated from the 73002 regolith during processing and scanned at high resolution by XCT. Here we pre-sent the initial lithologic classification of 134 individual >4 mm rock fragments separated from the 73002 core during the dissection process. Methodology: Drive tube 73002 was manually dissected in 0.5 cm depth intervals in three passes (Fig. 1) [4,5]. Each interval from pass 1 and 2 was sieved to <1 mm and >1 mm size fractions, and >1 mm particles were further manually subdivided into 1-2, 2-4, 4-10, and >10 mm size fractions. Pass 3 was not sieved, but >10 mm clasts were separated manually. Each 4-10 mm and >10 mm fragment was individually weighed, triply bagged in Teflon, and scanned by XCT. There are 60 rock fragments in Pass 1, 64 rock fragments in Pass 2 (from the 4-10 mm and >10 mm size fractions), and 8 rock fragments from Pass 3 (>10 mm size fraction). Each individually bagged rock fragment was scanned using the 180 kV nano-focus transmission source on the Nikon XTH 320 XCT system at NASA Johnson Space Center [6]. Scanning conditions varied considerably for individual particles, in large part be-cause of the large variation in size (0.008-19.623 g). All scans fell within the following range of scan conditions: 2.8-20.6 um voxel size; 90-155 kV voltage; 18-39 uA current; 1891-3141 projections; and 902-2000 slices. Results and Discussion: The 132 rock fragments from sample 73002 fall into the following general cat-gories: agglutinates (n = 6); basalts (13); impact melts (5); impact melt breccias (IMB; 42); regolith breccias (62); and soil breccias (4); see Figure 2 for representative examples of each lithology. Within most of these broad lithologic groups are recognizable subgroups. For example, a significant portion of regolith breccia fragments contain some agglutinate-like glass (n = 9) or are dilithologic (7) because they contain a single large clast (~50% or more by volume). Subgroups can be based on similarities to previously identified lunar lithologies, such as high-Ti basalts (9) and VLT basalts (4; Fig. 3), or based on commonly seen features within the fragments, such as poikilitic ilmenite IMB (10), ilmenite-lath IMB (12), or vesicular IMB (11) “groups”. Particles in the same “group” are not necessarily intended to be genetically related, but rather identify particles that are similar and that follow-up studies can classify in more detail [7]. Conclusion: Identification of lithologies based on XCT is a powerful tool, but a more absolute classification will sometimes require additional textural information from thin sections (e.g., glassy-matrix regolith vs. impact-melt vs. granulitic breccia) or quantitative mineral compositions (e.g., basalt vs. monomict breccia).

R A Zeigler↗