Search NASASearch

SEARCH · Search NASA

Results for “alternative carbon feedstocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Evaluating Crystallinity in Thermoplastic Composites for Aerospace Applications

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and faster production. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are directly influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Within thermoplastic PMC parts, crystallinity gradients can arise due to variations in part geometry, across part thicknesses, and along bonded joints. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials meet the high demands required for aerospace. Several different analytical techniques exist that can be used to characterize the bulk crystallinity of thermoplastic materials. However, many existing methods lack the specificity required to identify the subtle variations in crystallinity that may play a significant role in the performance and durability of PMC parts. Because of this, a significant amount of work is still required to fully characterize and understand the crystallinity profiles of thermoplastic PMCs and the resulting impact to material properties. This talk discusses the use of multiple techniques such as Differential Scanning Calorimetry, Polarized Light Optical Microscopy, and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in carbon fiber/thermoplastic composites. Samples of different crystallinity profiles were manufactured using various cooling procedures. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in aerospace applications.

Thermoplastics

Highly Porous Polyimide Gel for Use as Battery Separator with Room Temperature Ionic Liquid Electrolytes

Advanced aerospace vehicular concepts require advances in many existing technologies, including space power and energy storage systems. Batteries represent one of the major areas in need of improvement, both in terms of energy density and safety, with growing concerns over the fire safety of commercial lithium-ion batteries. This has prompted efforts to develop nonflammable battery components, namely the electrolyte and separator. Existing commercial lithium-ion batteries utilize polyolefin microporous membranes as separators with an electrolyte consisting of a lithium salt dissolved in a mixture of cyclic carbonate solvents. This separator/electrolyte combination has ionic conductivities in the range of 10 −2 to 10 −3 S/cm. However, the cyclic carbonate solvents are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative. They offer good ionic conductivities and are inherently nonvolatile and nonflammable, giving them a safety advantage. However, many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Alternative separator materials, such as polyimides, are non-flammable and are capable of accepting RTILs into their structure. Polyimide gels, with a composition of 4,4′-oxydianiline, 3,3′,4,4′-tetracarboxylic dianhydride and cross-linked with Desmodur N3300A, possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85% porosity) for lithium-ion transport and conduction, as well as good mechanical properties. Furthermore, these polyimide gels are compatible with selected imidazolium-based RTILs. Nonflammable separator/electrolyte systems with room-temperature conductivities in the range of 10 −3 S/cm have been evaluated. It has been demonstrated that 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was the most promising among six RTILs screened, in terms of both ionic conductivity and constant current cycling.

Polyimide

Novel Polyimide Battery Separator Imbibed with Room-Temperature Ionic Liquids

The journey to Mars will require advancements in many existing technologies, including space power and energy storage systems. According to the 2015 NASA Technology Roadmaps, energy storage is a critical technology area to develop for both terrestrial as well as future long-term space missions. Currently, batteries represent one of the major areas in need of advancement, both in terms of energy density as well as safety. Recently, concerns regarding the fire safety of commercial lithium-ion batteries have prompted efforts to produce nonflammable battery components, namely the electrolyte and separator. Commercial lithium-ion batteries utilize polyolefin separators imbibed with a lithium salt dissolved in cyclic carbonates. This separator/electrolyte combination imparts good ionic conductivities in the range of 10(exp -2) to 10(exp -3) S/cm. However, the cyclic carbonates and polyolefin separator are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative to cyclic carbonates. They offer good ionic conductivities, similar to those observed in cyclic carbonates, but are inherently nonvolatile and nonflammable giving them a safety advantage. Many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Polyimide aerogels possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85 porous), required for lithium ion conduction, as well as good mechanical properties. Furthermore, these materials are compatible with all tested RTILs. By creating a polyimide gel and imbibing the gel with a RTIL containing a lithium salt instead of super critically drying them to form aerogels, a nonflammable separator/electrolyte system with conductivities in the range of 1x10(exp -3) S/cm has been demonstrated.

Polyimide

A Dispersion-Strengthened Low-Density Niobium Alloy and Its Elevated Temperature Mechanical Performance

In response to the elevated-temperature and weight-reduction demands of modern aerospace applications, a novel oxide-dispersion-strengthened low-density niobium alloy (LDNb-ODS) was fabricated using laser powder bed fusion (L-PBF). To overcome powder procurement barriers, L-PBF feedstock was produced by blending commercial Nb521, Ti64, and Cr powder with Y2O3 nanoparticles via resonant acoustic mixing. Following L-PBF and a 1400°C vacuum heat treatment, the alloy achieved a density of 6.73 g/cc and a fine mean grain size of 4.62 µm stabilized by uniform ~30 nm yttria dispersoids. Microstructural analysis revealed a chemically inhomogeneous build with lack-of-fusion defects and a titanium (Ti) shift from a nominal 31.5 wt% in the starting powder blend to 24.8 wt% in the printed part due to preferential Ti loss during printing. Elevated-temperature tensile testing demonstrated that LDNb-ODS maintained a superior specific yield strength of 60-85 MPa/(g/cc) up to 800°C, outperforming nickel-based alloys Ni625, Ni230, and GRX-810. Between 870°C and 950°C, its specific strength surpassed both Ni718 and Ni625. In rapid stress-rupture testing at 1093°C and 20.7 MPa, uncoated LDNb-ODS survived 21.4 hours (a tenfold increase over legacy C-103) while an R512E silicide coating extended rupture life to 84.8 hours, confirming that oxidation accelerates low-stress failure. These findings demonstrate that additive manufacturing of LDNb-ODS provides a viable, lightweight alternative to nickel-based superalloys for high-temperature (>850°C) aerospace components.

Low Density Niobium Alloy

Development of a Thermal Radiator Optimization Tool with Alternate Coolants

The development of a modeling tool to optimize the design of a thermal radiator based on capacity, rejection temperature, geometry, type and coolant is presented. The radiator size is determined from the desired capacity, environmental conditions and rejection temperature. Flow through the radiator is derived from the overall heat load and prescribed inlet to outlet delta temperature for a given coolant. The tool considers radiator geometry (i.e., tube spacing and diameter, face-sheet thickness, overall size, etc.) and general type (i.e., parallel/manifold versus serpentine) in the optimization. Selection from a handful of potential coolants is also available in the tool which primarily affects necessary tube diameter to maintain turbulent flow and minimize pressure drop. An Equivalent System Mass (ESM) approach is utilized to include pump power in the optimization. Results from the tool and potential future enhancements are also discussed.

Coolant

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

Toilet

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Evaluating Crystallinity in Thermoplastic composites

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and manufacturing required in space. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are largely influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials reliably meet the high demands required by space exploration. This talk discusses the use of multiple techniques such as Polarized Light Optical Microscopy and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in various thermoplastic composites, including carbon fiber reinforced PMCs and novel bio-based Martian and Lunar regolith composites designed for in-situ manufacturing. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in space applications.

Thermoplastics

NASA Alternative Orion Small Cell Battery Design Support

The NASA Orion Crew Module Reference Design was produced to address large scale thermal runaway (TR) hazard with specific safety controls for the Orion Spacecraft. The design presented provides the description of a full scale battery design reference for implementation as a drop in replacement to meet all spacecraft energy requirements with compatible 120 Vdc electrical and mechanical interface using small cell technology (18650) packaging. The 32V SuperBrick incorporates unique support features and an electrical bus bar arrangement that allows cells negative can insertion into heat sink that is compressively coupled to the battery enclosure to promote good thermal management. The housing design also provides an internal flame suppression "filter tray" and positive venting path internal to the enclosure to allow hot effluent ejecta to escape in the event of single cell TR. Virtual cells (14P Banks) that are supported to provide cell spacing with interstitial materials to prevent side can failures that can produce cell to cell TR propagation. These features were successfully test in four separate TR run with the full scale DTA1 test article in February 2016. Successfully Completed Test Objectives - Four separate TR test runs with Full-Scale DTA1 housing with Two SuperBricks, Two SuperBrick Emulators All Tests resulted in "clean" gas with less than 6 C rise at Battery vent All Tests resulted in less than 2 C temperature rise on cold-plate outlet All Tests resulted in less than 6 psi pressure rise in the battery housing Test Run 1 -One neighbor cell TR, highest remaining neighbor 139 C. Ejecta shorted to bus caused prolonged additional heating, One shorted cell did experience TR after 12 minutes, remaining cells had adequate thermal margin Test Run 2 - No cell to cell propagation, highest neighbor cell 112 C; Test Run 3 - No cell to cell propagation, highest neighbor cell 96 C; Test Run 4 - No cell to cell propagation, highest neighbor cell 101 C; Primary TR testing and analysis were completed and reviewed for endorsement by NASA Engineering and Safety Center team members. All Key Test Objectives were met and the small cell design alternative was demonstrated and selected to be a feasible drop in replacement for the MPCV Orion CM Battery for EM2 mission.

Haynes, Chuck

Risks of Depress as a Fire Suppression Technique in Spacecraft

Spacecraft are designed to prevent fires through careful material selection and configuration control combined with electrical design controls and isolation of ignition sources. Despite these best efforts, fire risk still exists due to the potential for configuration changes with the introduction of crew and the potential for a ‘failure of imagination’ by designers in anticipating all fuel and ignition sources. Therefore, fire suppression is a critical capability for any crewed spacecraft as a last resort for crew survival. Many spacecraft suppression methods have relied on fire suppressants such as compressed carbon dioxide, nitrogen, and water. A proposed alternative is depressurization of the cabin as a method to extinguish a fire. Limited testing was conducted during Skylab and showed that depress could result in stirring the air flow and aggravating a fire before extinguishing. However, limited information was available on how the test was conducted. To better characterize the approach, testing was conducted at NASA’s White Sands Test Facility to evaluate the effect of depressurization on material extinguishment. The results showed that depressurization does not provide a safe and effective fire suppression capability. The testing approach, results, and conclusions are described and discussed.

Toni Griego

Hydrofluoroether (HFE) Cleaning Fluid Replacement and Qualification

This NASA Engineering and Safety Center (NESC) Technical Assessment Report addresses the urgent need to identify, test, and qualify replacement cleaning solvents and technologies following 3M’s decision to discontinue production of hydrofluoroether (HFE) products, including Novec HFE-7100, by the end of 2025. HFE-7100 is widely used across NASA for precision cleaning of ground and flight hardware, especially in oxygen system components, and as a heat transfer fluid in high-power-density thermal control systems. The assessment evaluates commercially available replacement solvents, alternative cleaning technologies, and their compatibility with NASA’s operational requirements. Key findings include the identification of viable solvent replacements, their performance in contaminant removal, materials compatibility, and oxygen system safety. The report also explores novel cleaning approaches, including aqueous, supercritical CO₂, cryogenic aerosol, plasma, UV-ozone, magnetically optimized fluids, and induced charge active filtration, highlighting their merits, limitations, and readiness for NASA adoption. The NESC provides recommendations for solvent selection, facility adaptation, and continued technology maturation to ensure mission continuity and regulatory compliance.

Alternative Cleaning Technologies

Bosch Carbon Catalyst Regeneration in Water I: Bosch Carbon Removal from Reacted Beads Utilizing Mechanical Agitation

The ability to recover oxygen from metabolic carbon dioxide is crucial for crewed long duration missions in which the atmosphere must be recycled. Two physiochemical methods are primarily employed for this purpose: the Bosch process and the Sabatier reaction. This paper focuses on the Bosch process. It utilizes hydrogen in the presence of a catalyst to form water and solid carbon out of metabolic carbon dioxide. The solid carbon product deposits onto the catalyst and eventually causes reactor over pressurization issues. Multiple methods are currently being investigated to regenerate the catalyst’s surface and break up the pressure causing carbon clogs. This paper explores whether water and mechanical abrasion would work to remove Bosch carbon by testing multiple washing conditions. The different washing conditions involved agitation intensity, heating, duration, and volume of water. It was found that it is possible to break up the clumps of carbon formed in the reactor through agitation with room temperature water in one hour and shows promise for completely cleaning the carbon off the beads’ surface.

Agitation

Bosch Carbon Catalyst Regeneration in Water III: Experiments for and Related to Thermal Shock

Bosch technology has the potential to close the atmospheric revitalization loop by providing theoretically 100% regeneration of metabolic carbon dioxide into oxygen. The main obstacle to using Bosch technology is over-pressurization issues in the carbon formation reactor. Prior work on Bosch catalyst regeneration established that agitating carbon coated beads in water broke up pressure causing clogs and regenerated the catalyst surface. This process proved to be time consuming with experiments taking at least one hour to regenerate ten grams of carbon coated beads. In an attempt to shorten the processing time, thermally shocking the carbon coated beads prior to mechanical agitation was tested. Agitating the carbon coated beads after exposure to a saturated steam environment was also tested to ensure that the steam generated by thermally shocking the carbon coated beads would not cause adverse effects. The rationale behind thermally shocking the carbon coated beads is that the bead would pull away from the carbon shell due to a difference in the thermal expansion coefficients. The results of this project show that the processing time can be cut in half when compared to previous work, and that saturated steam has little to no effect on regeneration.

Bosch Process

Micromechanics of crenulated fibers in carbon/carbon composites

The influence of crenulated noncircular fibers on the micromechanical stress states due to a transverse strain and to a temperature change in carbon/carbon composites is examined using the finite element method. Stresses at the interface of both fully bonded and fully disbonded fibers having two crenulation amplitudes and with two fiber volume fractions are presented. In each case, these interface stresses are compared to stresses at the interface of circular fibers which have the same degree of disbond and fiber volume fraction and are under the same loading conditions. For the disbonded cases, deformed meshes showing locations of fiber/matrix contact are also included. In addition to the interface stress states, selected composite properties are also computed and compared in each case examined. Interest in studying noncircular fibers stems from a desire to increase the transverse properties of carbon/carbon by introducing a mechanical interlocking between the fiber and the matrix. Results presented here indicate that this interlocking does in fact occur. Evidence from the interface stress data suggests, however, that any possible advantage of this interlocking may be outweighed by the disadvantage of stress concentrations which arise at the interface due to the crenulated geometry of the fibers.

E. E. Carapella