Search NASA⌕ Search

SEARCH · Search NASA

Results for “atmospheric electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

Atmospheric Electric Field-Mill Sensor Field Campaign Report

The foundation stone of atmospheric electricity is the existence of a Global Electric Circuit (GEC) influencing all of the planet. In fact, global thunderstorm activity acts as a voltage source that imposes a potential difference between the ionosphere (positively charged) and the Earth’s surface (negatively charged) of about ~300 kV. Such potential difference is discharged through the poorly conducting atmosphere in fair-weather regions, with atmospheric electric fields of ~100 V/m. First evidence of the GEC was gathered by scientists involved on the Carnegie vessel expeditions (early 20th Century), in which they describe a similar daily variation of the atmospheric electric field in different parts of the Pacific Ocean. Such variation become known as the Carnegie Curve (CC).

54 ENVIRONMENTAL SCIENCES↗

Diurnal variation of the fair-weather atmospheric electric field in Binchuan, China

With the purpose of understanding the variation of fair-weather atmospheric electric field, the vertical component of atmospheric electric field (recorded as Ez) has been measured in the town Binchuan (25°50'N, 100°34'E, 1438.7 m asl) of Dali city, Yunnan, China from June 14, 2017 to December 1, 2020. Automatic measured visual range is used as a proxy of aerosol concentration. The mean diurnal variation curve of the fair-weather Ez in Binchuan, having two peaks occurred at around 9LT and 20LT, shows little correlation with the well-known Carnegie Curve and other two high-latitude sites' Curves. While strong negative correlation between fair-weather Ez and visual range is found, indicating the variation of fair-weather is dominated by aerosol concentration. The main source of aerosol concentration variation probably sunrise and sunset effect. We support our findings by comparing Ez, visual range with sunrise and sunset times. The peaks (troughs) of Ez (visual range) are proved to have weak correlations with anthropogenic pollution through comparing the Ez, visual range under workdays and holidays.

54 ENVIRONMENTAL SCIENCES↗

Responses of the AC/DC Global Electric Circuit to Volcanic Electrical Activity in the Hunga Tonga-Hunga Ha'apai Eruption on 15 January 2022

Responses of the AC and DC global electric circuits (GECs) to the large eruption of the Hunga Tonga-Hunga Ha'apai (HT-HH) volcano on 15 January 2022 are discussed. The AC-related investigation is based on Schumann resonance (SR) measurements from six stations on four continents. The DC-related investigation utilizes atmospheric electric field (potential gradient, PG) measurements from six recording stations in Europe and the USA. According to data from the GLD360 and WWLLN lightning detection networks, the peak lightning stroke rate, 83/s, was dominated by negative polarity lightning, but the distributions of positive and negative lightning discharges in latitude and longitude around the volcano differed. A global intensification of SR is apparent in connection with the enhanced lightning activity caused by the eruption. SR data-based results confirm that the lightning activity in the eruption dominated the naturally occurring global activity for a period of about 1 hr. The highly localized increase in lightning activity over HT-HH was a unique point source of SR excitation. PG measurements suggest that impulse-like charging of the DC GEC, by ~15%, via negative cloud-to-ground lightning strokes took place twice during the eruption. A time constant of 7 or 8 min has been inferred for near-surface PG changes due to these enhancements. This could be the first direct measurement of the time constant of the GEC near the Earth's surface, as well as the first observation of the direct charging of the DC GEC by a unique atmospheric electrified source.

58 GEOSCIENCES↗

Lightning strike prediction at the Savannah River Site

At the Savannah River Site, employees receive warnings about lightning only after three strikes have already occurred near the site. In order to increase employee safety, it is preferential to warn employees of a lightning threat much sooner. We used data from an on-site Electric Field Mill to measure values of the atmospheric electric charge. We also used lightning detection data from the National Lightning Detection Network and the Geostationary Lightning Mapper. By comparing the data of each, we can determine how long before or after a lightning strike did the Electric Field Mill first measure within our lightning detection threshold. If the detection threshold occurs before the strike does, this provides a lead time for knowing about lightning risks before they happen. Our findings conclude that 95% of lightning strikes have a lead time in the electric field where we can predict the lightning before it occurs and warn employees of the potential lightning threat. However, our lightning detection threshold can occur even without lightning or precipitation. Finding how these false lightning alarms affect our data is necessary to improving the lightning warning system.

54 ENVIRONMENTAL SCIENCES↗

The influence of the processing parameters on the reactive flash sintering of ZrO 2 -CeO 2

Reactive flash sintering (RFS) is a method that was recently developed to produce dense single-phase bulk ceramic parts through solid-state reactions in a single-step that only takes a few minutes. The influence of the RFS parameters on the phase purity of a simple mixed oxide, (Zr 0.8 ,Ce 0.2 )O 2 , was investigated. Parameters such as furnace temperature, furnace atmosphere, electric current density, and alternating current (AC) or direct current (DC) were examined. It was found that (Zr 0.8 ,Ce 0.2 )O 2 pellets with high densities, above 90% of its theoretical density, can be produced by RFS in a few minutes when RFS occurs under oxidizing atmospheres, AC fields with current densities of 100 mA·mm –2 , and at a furnace temperature of 1200°C. Reducing conditions such as Ar-H 2 atmosphere and DC fields, low furnace temperatures, and low current densities resulted in phase impurities and poor reactions between the ZrO 2 and the CeO 2 powders. These results show that RFS is a useful method to produce mixed oxides, but it is very sensitive to the processing parameters. This is the first time that the influence of most of the RFS processing parameters has been studied systematically. Thus, the present work aims to provide guidelines on selecting the right processing parameters when exploring RFS.

36 MATERIALS SCIENCE↗

Volcanic electrification: recent advances and future perspectives

Abstract The electrification of volcanic plumes has been described intermittently since at least the time of Pliny the Younger and the 79 AD eruption of Vesuvius. Although sometimes disregarded in the past as secondary effects, recent work suggests that the electrical properties of volcanic plumes reveal intrinsic and otherwise inaccessible parameters of explosive eruptions. An increasing number of volcanic lightning studies across the last decade have shown that electrification is ubiquitous in volcanic plumes. Technological advances in engineering and numerical modelling, paired with close observation of recent eruptions and dedicated laboratory studies (shock-tube and current impulse experiments), show that charge generation and electrical activity are related to the physical, chemical, and dynamic processes underpinning the eruption itself. Refining our understanding of volcanic plume electrification will continue advancing the fundamental understanding of eruptive processes to improve volcano monitoring. Realizing this goal, however, requires an interdisciplinary approach at the intersection of volcanology, atmospheric science, atmospheric electricity, and engineering. Our paper summarizes the rapid and steady progress achieved in recent volcanic lightning research and provides a vision for future developments in this growing field.

58 GEOSCIENCES↗

Polarity Asymmetries in Rocket‐Triggered Lightning

Abstract The dissonant development of positive and negative lightning leaders is a central question in atmospheric electricity. It is also the likely root cause of other reported asymmetries between positive and negative lightning flashes, including the ones regarding: stroke multiplicity, recoil activity, leader velocities, and emission of energetic radiation. In an effort to contrast lightning leaders of different polarities, we highlight the staggering differences between two rocket‐triggered lightning flashes. The flash beginning with upward positive leaders exhibits an initial continuous current stage followed by multiple sequences of dart leaders and return strokes. On the other, in its opposite‐polarity counterpart, the upward development of negative leaders is by itself the entire flash. As a result, the flash with negative leaders is faster, briefer, transfers less charge to the ground, has lower currents, and smaller spatial extent. We conclude by presenting a discussion on the three fundamental leader propagation modes.

54 ENVIRONMENTAL SCIENCES↗

Spatio-temporal electric field distributions in an atmospheric plasma jet impinging on a microchannel array surface

The electric field distribution in the ionization waves (IWs) propagating over a microchannel array dielectric surface, with the channels either empty or filled with distilled water, is measured by ps electric field induced second harmonic generation. The surface IW is initiated by the atmospheric pressure N 2 –Ar plasma jet impinging on the surface vertically and powered by ns pulse discharge bursts. The results show that the electric field inside the microchannels, specifically its horizontal component, is enhanced by up to a factor of 2. The field enhancement region is localized within the channels. The vertical electric field inside the channels lags in time compared to the field measured at the ridges, indicating the transient reversal of the IW propagation direction across the channels (toward the jet). This is consistent with the phase-locked plasma emission images and confirmed by the kinetic modeling predictions, which show that the IW ‘jumps’ over the empty channels and propagates into the channels only after the jump between the adjacent ridges. When the channels are filled with water, the wave speed increases by up to 50%, due to the higher effective dielectric constant of the surface. No evidence of a significant electric field enhancement near the dielectric surface (ceramic or water) has been detected, within the spatial resolution of the present diagnostic, ~100 μ m.

plasmas and liquids↗

Electric field dynamics in an atmospheric pressure helium plasma jet impinging on a substrate

Time and spatially resolved electric field measurements by Stark polarization spectroscopy in a nanosecond pulsed atmospheric pressure helium jet operating in ambient air and impinging on a conductive indium tin oxide (ITO) coated glass slide are reported. An automatic fitting procedure of the Stark shifted spectra taking into consideration constraints regarding Stark components positions and intensities as well as molecular nitrogen emission subtraction was implemented. This allowed electric field vector components measurements both in the gas phase and at the interface when the jet impinges on the substrate and during the development of a surface ionization wave. The obtained results show an increase of the axial electric field in the jet effluent in the gas phase with a peak magnitude from 12 to 18 kVcm -1 before the ionization wave impinges on the substrate. A steep electric field enhancement to a peak value of about 24 kVcm -1 was observed when the ionization wave impinges on the surface. A peak radial electric field of about 27 kVcm -1 was measured off-axis in the surface ionization wave. These results are consistent with previously reported modelling predictions. While Stark polarization spectroscopy is limited to electric field measurement from regions with emission, we illustrate that the capability to measure near surface electric fields in helium makes it a valuable complementary technique for the electric field-induced second harmonic (E-FISH) technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Negative Medium-Voltage Direct Current Discharges in Air under Simulated Sub-Atmospheric Pressures for All-Electric Aircraft

The increase in the global temperature due to greenhouse gas emissions is a major concern to the world. To achieve the goal of zero emissions by 2050 in the USA the practical realization of all-electric vehicles, particularly all-electric aircraft (AEA), is important. For the design of electrical power systems (EPSs) in all-electric aircraft, a bipolar medium-voltage direct current (MVDC) system of ±5 kV is being investigated. However, several challenges manifest when using such voltages in a low-pressure environment. One of the main challenges is the partial discharge (PD) behavior of the insulation. It is important to study the PD behavior of the insulation by simulating the aviation environment in the lab. This work aimed to study the partial discharge behavior of air under a negative DC voltage in a needle-to-plane electrode geometry by simulating the aviation pressures in the lab. The partial discharge inception voltage (PDIV) and the breakdown voltage (BDV) show an obvious pressure-dependent variation. Regression analysis was performed to better understand the relationship between the PDIV and pressures. Plots were drawn for the average discharge current at each voltage step until breakdown. This paper’s findings can provide valuable insight into the design of EPS for an AEA. To the best of our knowledge, such a study has not been carried out to date.

air discharge↗

Influence of discharge polarity on streamer breakdown criterion of ambient air in a non-uniform electric field

Streamer breakdown of atmospheric air with non-uniform dc electric field in a needle-to-plate electrode configuration is studied using a semi-analytic model and experimental measurements. A high voltage (either positive or negative) is applied to a hollow needle with 0.51 mm outer diameter and 0.25 mm inner diameter separated from a planar ground electrode by a gap distance of 0.1–1.4 cm. Breakdown voltages are recorded for both positive and negative discharge polarities. Empirical relations between the critical avalanche size for streamer breakdown and the gap distance are proposed. Using these empirical relations, a semi-analytic model based on Meek's criterion for streamer breakdown is developed to accurately predict the measured breakdown voltages. It is found that for pd > 380 Torr cm (or d > 0.5 cm at one atmosphere) streamer breakdown of ambient air occurs at a lower applied voltage for a positively biased needle compared to that with a negatively biased needle, referred as the polarity effect. For pd < 380 Torr cm breakdown is attained at a lower applied voltage with a negatively biased needle compared to that with a positively biased needle, and breakdown mode transits from the polarity effect to the so called inverted polarity effect.

42 ENGINEERING↗

Sensitivity of Wind Turbine Array Downstream Effects to the Parameterization Used in WRF

The Weather Research and Forecasting (WRF) Model has been extensively used for wind energy applications, and current releases include a scheme that can be applied to examine the effects of wind turbine arrays on the atmospheric flow and electricity generation from wind turbines. Herein we present a high-resolution simulation using two different wind farm parameterizations: 1) the “Fitch” parameterization that is included in WRF releases and 2) the recently developed Explicit Wake Parameterization (EWP) scheme. We compare the schemes using a single yearlong simulation for a domain centered on the highest density of current turbine deployments in the contiguous United States (Iowa). Pairwise analyses are applied to diagnose the downstream wake effects and impact of wind turbine arrays on near-surface climate conditions. On average, use of the EWP scheme results in small-magnitude wake effects within wind farm arrays and faster recovery of full WT array wakes. This in turn leads to smaller impacts on near-surface climate variables and reduced array–array interactions, which at a systemwide scale lead to summertime capacity factors (i.e., the electrical power produced relative to nameplate installed capacity) that are 2%–3% higher than those from the more commonly applied Fitch parameterization. It is currently not possible to make recommendations with regard to which wind farm parameterization exhibits higher fidelity or to draw inferences with regard to whether the relative performance may vary with prevailing climate conditions and/or wind turbine deployment configuration. However, the sensitivities documented herein to the wind farm parameterization are of sufficient magnitude to potentially influence wind turbine array siting decisions. Thus, our research findings imply high value in undertaking combined long-term high-fidelity observational studies in support of model validation and verification.

17 WIND ENERGY↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part III: Variability

Abstract Daily expected wind power production from operating wind farms across North America are used to evaluate capacity factors (CF) computed using simulation output from the Weather Research and Forecasting (WRF) Model and to condition statistical models linking atmospheric conditions to electricity production. In Parts I and II of this work, we focus on making projections of annual energy production and the occurrence of electrical production drought. Here, we extend evaluation of the CF projections for sites in the Northeast, Midwest, southern Great Plains (SGP), and southwest U.S. coast (SWC) using statewide wind-generated electricity supply to the grid. We then quantify changes in the time scales of CF variability and the seasonality. Currently, wind-generated electricity is lowest in summer in each region except SWC, which causes a substantial mismatch with electricity demand. While electricity of residential heating may shift demand, research presented here suggests that summertime CF are likely to decline, potentially exacerbating the offset between seasonal peak power production and current load. The reduction in summertime CF is manifest for all regions except the SGP and appears to be linked to a reduction in synoptic-scale variability. Using fulfillment of 50% and 90% of annual energy production to quantify interannual variability, it is shown that wind power production exhibits higher (earlier fulfillment) or lower (later fulfillment) production for periods of over 10–30 years as a result of the action of internal climate modes. Significance Statement Electrical power system reassessment and redesign may be needed to aid efficient increased use of variable renewables in the generation of electricity. Currently wind-generated electricity in many regions of North America exhibits a minimum in summertime and hence is not well synchronized with electricity demand, which tends to be maximized in summer. Future projections indicate evidence of reductions in wind power during summer that would amplify this offset. However, electrification of heating may lead to increased wintertime demand, which would lead to greater synchronization.

Coburn, Jacob↗

Comparison of Long-Term Bioenergy with Carbon Capture and Storage to Reference Power Generation Technologies Using CO2 Avoidance Cost in the U.S.

Bioenergy with carbon capture and storage (BECCS) can sequester atmospheric CO2, while producing electricity. The CO2 avoidance cost (CAC) is used to calculate the marginal cost of avoided CO2 emissions for BECCS as compared to other established energy technologies. A comparative analysis using four different reference-case power plants for CAC calculations is performed here to evaluate the CO2 avoidance cost of BECCS implementation. Results from this work demonstrate that BECCS can generate electricity at costs competitive with other neutral emissions technologies, while simultaneously removing CO2 from the atmosphere. Approximately 73% of current coal power plants are approaching retirement by the year 2035 in the U.S. After considering CO2 sequestered from the atmosphere and coal power plant CO2 emissions displaced by BECCS, CO2 emissions can be reduced by 1.4 billion tonnes per year in the U.S. alone at a cost of $88 to $116 per tonne of CO2 removed from the atmosphere, for 10% to 90% of available biomass used, respectively. CAC calculations in this paper indicate that BECCS can help the U.S. and other countries transition to a decarbonized electricity grid, as simulations presented in this paper predict that BECCS power plants operate at lower CACs than coal plants with CCS.

25 ENERGY STORAGE↗