Search NASA⌕ Search

SEARCH · Search NASA

Results for “breakthrough tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NETL DAC Center Test Report

Sample of testing and analysis reports for breakthrough testing conducted at the NETL Direct Air Capture (DAC) Center on Lewatit resin.

42 ENGINEERING↗

Monitoring Xenon Capture in a Metal Organic Framework Using Laser-Induced Breakdown Spectroscopy

Molten salt reactor operation will necessitate circulation of a cover gas to remove certain evolved fission products and maintain an inert atmosphere. The cover gas leaving the reactor core is expected to contain both noble and non-noble gases, aerosols, volatile species, tritium, and radionuclides and their daughters. To remove these radioactive gases, it is necessary to develop a robust off-gas system, along with novel sensors to monitor the gas stream and the treatment system performance. In this study, a metal organic framework (MOF) was engineered for the capture of Xe, a major contributor to the off-gas source term. The engineered MOF column was tested with a laser-induced breakdown spectroscopy (LIBS) sensor for noble gas monitoring. The LIBS sensor was used to monitor breakthrough tests with various Xe, Kr, and Ar mixtures to determine the Xe selectivity of the MOF column. This study offers an initial demonstration of the feasibility of monitoring off-gas treatment systems using a LIBS sensor to aid in the development of new capture systems for molten salt reactors.

47 OTHER INSTRUMENTATION↗

High-Performance CO 2 Capture from Air by Harnessing the Power of CaO- and Superbase-Ionic-Liquid-Engineered Sorbents

Direct air capture (DAC) of CO 2 by solid porous materials represents an attractive “negative emission” technology. However, state-of-the-art sorbents based on supported amines still suffer from unsolved high energy consumption and stability issues. For this work, taking clues from the CO 2 interaction with superbase-derived ionic liquids (SILs), high-performance and tunable sorbents in DAC of CO 2 was developed by harnessing the power of CaO- and SIL-engineered sorbents. Deploying mesoporous silica as the substrate, a thin CaO layer was first introduced to consume the surface-OH groups, and then active sites with different basicities (e. g., triazolate and imidazolate) were introduced as a uniformly distributed thin layer. The as-obtained sorbents displayed high CO 2 uptake capacity via volumetric (at 0.4 mbar) and breakthrough test (400 ppm CO 2 source), rapid interaction kinetics, facile CO 2 releasing, and stable sorption/desorption cycles. Operando diffuse reflectance infrared Fourier transformation spectroscopy (DRIFTS) analysis under simulated air atmosphere and solid-state NMR under 13 CO 2 atmosphere demonstrated the critical roles of the SIL species in low-concentration CO 2 capture. The fundamental insights obtained in this work provide guidance on the development of high-performance sorbents in DAC of CO 2 by leveraging the combined advantages of porous solid scaffolds and the unique features of CO 2 -philic ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic Pairs-Engineered Fluorinated Covalent Organic Frameworks Toward Direct Air Capture of CO 2

The covalent organic frameworks (COFs) possessing high crystallinity and capability to capture low-concentration CO 2 (400 ppm) from air are still underdeveloped. The challenge lies in simultaneously incorporating high-density active sites for CO 2 insertion and maintaining the ordered structure. Herein, a structure engineering approach is developed to afford an ionic pair-functionalized crystalline and stable fluorinated COF (F-COF) skeleton. The ordered structure of the F-COF is well maintained after the integration of abundant basic fluorinated alcoholate anions, as revealed by synchrotron X-ray scattering experiments. The breakthrough test demonstrates its attractive performance in capturing (400 ppm) CO 2 from gas mixtures via O$-$C bond formation, as indicated by the in situ spectroscopy and operando nuclear magnetic resonance spectroscopy using 13 C-labeled CO 2 sources. Both theoretical and experimental thermodynamic studies reveal the reaction enthalpy of ≈-40 kJ mol -1 between CO 2 and the COF scaffolds. This implies weaker interaction strength compared with state-of-the-art amine-derived sorbents, thus allowing complete CO 2 release with less energy input. The structure evolution study from synchrotron X-ray scattering and small-angle neutron scattering confirms the well-maintained crystalline patterns after CO 2 insertion. In conclusion, the as-developed proof-of-concept approach provides guidance on anchoring binding sites for direct air capture (DAC) of CO 2 in crystalline scaffolds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CACTUS: CO 2 Aerogel Capture Towards Utilization and Sequestration

The CACTUS project aimed to develop a novel solid sorbent and sorption module prototype for direct air capture (DAC) of carbon dioxide, by a moisture-swing adsorption (MSA) mechanism. Because MSA uses changes in humidity, not temperature to switch the sorbent from capturing CO 2 to releasing concentrated CO 2 it is > 4X more energy-efficient than the thermal swing process. The goal was to develop a sorbent with a CO 2 capture capacity of 1 mmol CO 2 /g sorbent (or 0.75 mmol CO 2 /g structured sorbent), at a projected scaled cost of < $\$$15/kg sorbent and demonstration of a path to < $\$$100/ton CO 2 . At the end of the project, we achieved 0.8 mmol CO 2 /g sorbent powders, 0.37 mmol CO 2 /g structured sorbent (50% of target), at a projected cost of $\$$29/kg sorbent and an estimated cost of $\$$160/ton CO 2 . The key innovation was SRI’s patented polymer aerogel synthesis platform, which was adapted to produce a nanoporous aerogel with a high density of CO 2 -adsorbing quaternary ammonium groups. This research discovered a new ammonium polymer sorbent and identified a chemical path for its fabrication. The new process solved the monomer immiscibility challenge encountered with the initial method (ammonium is hydrophilic and the crosslinker is hydrophobic). The team fabricated structured sorbent sheets consisting of a non-woven porous substrate impregnated with ammonium polymer and demonstrated its operation in custom made breakthrough test setup MSA DAC built at SRI, and which operates similarly to the envisioned large-scale CO 2 capture plant, to provide data for techno-economic analysis (TEA). TEA sensitivity analysis indicated that ∼$\$$100/ton CO 2 can be achieved if the target capacity of 0.75 mmol CO 2 /g structured sorbent is met. Also identified routes to decrease sorbent manufacturing cost to ∼$\$$19/kg by reducing amounts and recycling the organic solvents. More work is needed on transitioning process manufacturing from powders (which showed a capacity of up to 0.8 mmol/g sorbent) to structured sheets which showed a capacity of 0.37 mmol CO 2 /g structured sorbent (or 0.44 mmol/g sorbent if one excludes the inert porous substrate). This is likely due to different micro/nano-structure of the sorbent and material processing constraints at the laboratory scale. Sorbent cycling studies (> 100 cycles) are needed to investigate its performance stability over time.

99 GENERAL AND MISCELLANEOUS↗

Compromise of Personal Protective Clothing from Liquid Exposure

Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory’s Spallation Neutron Source transfer bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or that moisture (sweat) allowed contamination to wick through the protective clothing. To pursue this issue, radiological protection staff looked more closely, however, at the specific area of the clothing where contamination was highest; under enhanced lighting and photochromic manipulation, there appeared to have been some type of moisture in the area. Recognizing the possibility that moisture may have allowed for migration of contamination through the clothing, further experiments were undertaken to determine under which conditions this transport might have occurred. The objective for this work was to identify the susceptibility of different types of personal protective clothing to various liquids encountered in the workplace.Method: Several tests were performed to determine if perspiration had enabled migration of contamination, and to identify what other liquids might have affected contamination transport. Two layers of personal protective clothing were subjected to static conditions and dynamic conditions, to include active rubbing of the materials while wet. Food dye added to each of the liquids tested enabled visual indications of liquid breakthrough. Additional tests were conducted to see if solid contamination could be transported through the materials along with the liquids. As a result, it was found that all but one type of non-rubberized personal protective clothing in use at Oak Ridge National Laboratory were permanently compromised to some extent by the solvents used for decontamination. It was determined that most common cleaning agents immediately and permanently destroyed the hydrophobic nature of several of the splash-resistant protective clothing materials, allowing for radioactive contamination to penetrate through the material to the worker. Work around wet surfaces or performing wet decontamination will only be performed in protective clothing known to prevent transport of the wetting agent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

A goldilocks computational protocol for inhibitor discovery targeting DNA damage responses including replication-repair functions

While many researchers can design knockdown and knockout methodologies to remove a gene product, this is mainly untrue for new chemical inhibitor designs that empower multifunctional DNA Damage Response (DDR) networks. Here, we present a robust Goldilocks (GL) computational discovery protocol to efficiently innovate inhibitor tools and preclinical drug candidates for cellular and structural biologists without requiring extensive virtual screen (VS) and chemical synthesis expertise. By computationally targeting DDR replication and repair proteins, we exemplify the identification of DDR target sites and compounds to probe cancer biology. Our GL pipeline integrates experimental and predicted structures to efficiently discover leads, allowing early-structure and early-testing (ESET) experiments by many laboratories. By employing an efficient VS protocol to examine protein-protein interfaces (PPIs) and allosteric interactions, we identify ligand binding sites beyond active sites, leveraging in silico advances for molecular docking and modeling to screen PPIs and multiple targets. A diverse 3,174 compound ESET library combines Diamond Light Source DSI-poised, Protein Data Bank fragments, and FDA-approved drugs to span relevant chemotypes and facilitate downstream hit evaluation efficiency for academic laboratories. Two VS per library and multiple ranked ligand binding poses enable target testing for several DDR targets. This GL library and protocol can thus strategically probe multiple DDR network targets and identify readily available compounds for early structural and activity testing to overcome bottlenecks that can limit timely breakthrough drug discoveries. By testing accessible compounds to dissect multi-functional DDRs and suggesting inhibitor mechanisms from initial docking, the GL approach may enable more groups to help accelerate discovery, suggest new sites and compounds for challenging targets including emerging biothreats and advance cancer biology for future precision medicine clinical trials.

59 BASIC BIOLOGICAL SCIENCES↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transformational Sorbent-Based Process for a Substantial Reduction in the Cost of CO2 Capture

Adsorption processes have the potential to significantly reduce the CO2 capture cost from power plants and industrial flue gases. InnoSepra has developed several sorbent-based technologies to obtain very high CO2 recovery and high purity CO2 while meeting the EOR/sequestration product specifications. A first-generation process was shown to achieve CO2 recoveries greater than 94% at CO2 purities in the range of 98.5-99.5%. The absolute heat energy required for the process was not only 40% lower than MEA but also was needed at a much lower temperature. This work will present the performance of the second-generation InnoSepra process which is based on a breakthrough sorbent regeneration method. This process has a projected 45% lower capital cost compared to MEA, less than 16% loss in plant output for CO2 capture and compression, and a CO2 capture cost at least 55% lower than MEA. Lab scale testing and the process simulations indicate a CO2 capture performance similar to or better than the first-generation process. Pilot scale drying and breakthrough tests were carried out at the Technology Centre Mongstad (TCM), Norway, and lab-scale cyclic tests were carried out at InnoSepra to confirm the process improvement. During these tests, InnoSepra’s flue gas purification technology was also tested at TCM. It can provide a low-cost option for the removal of NO2 and SOX to sub-ppm levels as well as a significant reduction in aerosol emissions.

08 HYDROGEN↗

Harnessing Uncertainty through Functional Data Analysis in Gas Breakthrough Data

Detecting subsurface explosions from radionuclide gas migration through rock fractures is an effective way to identify nuclear activity. Los Alamos National Laboratory (LANL) has developed simulation methods, based on data from the 1962 Hardhat underground nuclear test, to predict gas breakthrough times at the surface. However, these methods rely on an imperfect understanding of the relationship between rock damage and fracture permeability. Our clinic project studies methods for predicting breakthrough curves that characterize total mass produced as a function of time, as well as quantifying the uncertainty associated with these predictions. The model that is currently employed to relate damage to permeability uses an empirically motivated power-law expression, with a range of parameter values that are compatible with the experimental Hardhat data. We develop emulators, built from functional data analysis techniques and trained on simulation data, that rapidly predict the gas breakthrough curve given a damage field and given the parameter values of the power-law equation. Using Bayesian regression, we address the problem of uncertainty quantification in our emulators. Finally, in order to test the robustness of the model, we further validate it on a damage field representing different physical conditions.

58 GEOSCIENCES↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY25 Ion Exchange Processing for the West Area Risk Management (WARM) Project

The West Area Risk Management (WARM) Project was established to enable near-term retrieval and pretreatment of tank waste from Hanford’s 200 West Area and to support deployment of an ion exchange (IX) system capable of producing cesium-depleted supernate suitable for offsite treatment and disposal. The WARM experimental campaign was designed to provide key data for design and operational planning of the 200 W IX system, which plans to utilize crystalline silicotitanate (CST) as the active media for cesium removal. This report documents a comprehensive FY25 experimental campaign designed to produce key technical data required for design and operational planning of the WARM IX system. Testing includes assessing Cs and Sr breakthrough performance in a 4-column system, Cs capacity batch contact testing, phosphate precipitation assessments, reduced-hydroxide feed displacement evaluation, and Sr speciation impacts on Sr removal. The experimental results provide detailed trends in Cs and Sr loading behavior, breakthrough performance across a 4-column staged IX system, distribution profiles within CST beds, and projections of operational flowrates relative to Waste Acceptance Criteria (WAC) limits. Batch contact testing established equilibrium partitioning behavior for the S1–S5 simulants and characterized how matrix chemistry influenced Cs sorption onto CST. Additionally, further evaluations on waste matrix as it pertains to precipitation potential were also determined. Collectively, these datasets support engineering design choices for WARM system throughput and pretreatment planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulated Moving Bed Process for CO 2 Capture from Humid Postcombustion Flue Gases Using MUF-16

Simulated moving bed (SMB) designs are increasingly being adapted for the separation of multicomponent gaseous mixtures. In this work, we develop a modified SMB process for capturing CO 2 from humid postcombustion flue gas using MUF-16 (MUF = Massey University Framework). MUF-16 shows excellent selectivity for CO 2 over N 2 , moderate heats of adsorption for CO 2 and H 2 O, and no competitive sorption of CO 2 over water at relative humidities relevant to postcombustion capture. We utilize these characteristics to propose a continuous process that uses N 2 from the feed as the desorbent for the water, eliminating the need for a separate desiccant bed and allowing for localized heating during desorption for H 2 O-saturated MOF beds. Single-component isotherms, single-column breakthrough experiments, and SO 2 stability tests suggest the excellent suitability of MUF-16 to this separation via the proposed SMB design.

CO2 capture from humid flue gas↗

Hanford Tank Waste Matrix Impact on Ion Exchange Performance Using Crystalline Silicotitanate

The removal of radiocesium from Hanford tank waste supernate is a critical step in preparing feed for low-activity waste immobilization. This study evaluated cesium ion exchange performance using crystalline silicotitanate (CST) media in a series of tests designed to evaluate the influence of waste matrix variability on capacity and kinetics. Tank waste supernate subsampled from five Hanford double-shell tanks encompassed a range of sodium, hydroxide, nitrate, and nitrite concentrations in order to assess the impact of feed variability on the performance of the ion exchange system. Both equilibrium and dynamic ion exchange tests were conducted to quantify cesium distribution coefficients and breakthrough behavior under prototypic operating conditions. Results indicated that effective cesium capacity varied by up to a factor of five across the matrices tested, with higher sodium concentrations significantly reducing uptake. Kinetic behavior was similarly matrix-dependent, with solution viscosity contributing to a twofold variation in mass-transfer rates. These results demonstrate the strong dependence of CST ion exchange performance on waste composition and must be incorporated into predictive models for future treatment system design and optimization.

Westesen, Amy M.↗