Simulation-based assessment on stochastic load scheduling for building cooling systems

Here, to fill knowledge gaps related to stochastic load scheduling, we performed a comprehensive evaluation of the stochastic load scheduling for building cooling systems. Specifically, we studied the common uncertain variables in the load scheduling process for building cooling systems and categorized those variables based on their dynamic patterns. We then developed a generic stochastic load scheduling framework and applied it to building cooling systems that served a simulated community. This community consists of 100 heterogeneous houses and serves as a virtual testbed for evaluating the performance of stochastic load scheduling. In this evaluation, we considered representatives of uncertain variables with different dynamic patterns and included 100 realizations of the considered uncertainty in the evaluation to better catch the probability distribution of the control performance. The evaluation results suggest that deterministic load scheduling can reduce the operating energy cost by 18% but its performance can be affected by uncertainty. Stochastic load scheduling can further decrease the operating energy cost under uncertainty compared to deterministic load scheduling. We also found that the effectiveness of stochastic load scheduling in handling uncertainty is not directly associated with the number of uncertainty scenarios that are considered in its formulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

The economics of solar powered absorption cooling

Analytic procedure evaluates cost of combining absorption-cycle chiller with solar-energy system in residential or commercial application. Procedure assumes that solar-energy system already exists to heat building and that cooling system must be added. Decision is whether to cool building with conventional vapor-compression-cycle chiller or to use solar-energy system to provide heat input to absorption chiller.

Bartlett, J. C.↗

Analysis of building heating and cooling

Energy Conservation Program (ECP) gives design engineer methodology and easy-to-use computer program for simulating hourly thermal characteristics over full year for individually characterized zones within building. Inexpensive system can be used to develop thermal model of building to aid selection of most suitable and economical heating and cooling system for building

Chai, V. W.↗

Solar heating and cooling system for an office building at Reedy Creek Utilities

The solar energy system installed in a two story office building at a utilities company, which provides utility service to Walt Disney World, is described. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled water. Performance to date has equaled or exceeded design criteria.

Source record↗

Building application of solar energy. Study no. 4: Scenarios for the utilization of solar energy in southern California buildings, change 1

Plausible future market scenarios for solar heating and cooling systems into buildings in the area served by the Southern California Edison Company. A range of plausible estimates for the number of solar systems which might be installed and the electrical energy which might be displaced by energy from these systems are provided. The effect on peak electrical load was not explicitly calculated but preliminary conclusions concerning peak load can be inferred from the estimates presented. Two markets are investigated: the single family market and the large power commercial market.

Davis, E. S.↗

Initial operation of a solar heating and cooling system in a full-scale solar building test facility

The Solar Building Test Facility (SBTF) was constructed to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test the performance of a complete solar heating and cooling system, (3) investigate component interactions, and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is printed along with the objectives, test approach, expected system performance, and some preliminary results.

Knoll, R. H.↗

Design and operation of a solar heating and cooling system for a residential size building

The first year of operation of solar house is discussed. Selected design information, together with a brief system description is included. The house was equipped with an integrated solar heating and cooling system which uses fully automated state-of-the art. Evaluation of the data indicate that the solar house heating and cooling system is capable of supplying nearly 100 percent of the thermal energy required for heating and approximately 50 percent of the thermal energy required to operate the absorption cycle air conditioner.

Littles, J. W.↗

Initial operation of a solar heating and cooling system in a full-scale solar building test facility

The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.

Knoll, R. H.↗

Assessment of solar-assisted gas-fired heat pump systems

As a possible application for the Goldstone Energy Project, the performance of a 10 ton heat pump unit using a hybrid solar gas energy source was evaluated in an effort to optimize the solar collector size. The heat pump system is designed to provide all the cooling and/or heating requirements of a selected office building. The system performance is to be augmented in the heating mode by utilizing the waste heat from the power cycle. A simplified system analysis is described to assess and compute interrrelationships of the engine, heat pump, and solar and building performance parameters, and to optimize the solar concentrator/building area ratio for a minimum total system cost. In addition, four alternative heating cooling systems, commonly used for building comfort, are described; their costs are compared, and are found to be less competitive with the gas solar heat pump system at the projected solar equipment costs.

Lansing, F. L.↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Solar energy to heat and cool a new NASA Langley office building

A solar heating and cooling system will be installed at a new NASA office building. The objective of this project is to establish a full-scale working test-bed facility to investigate solar energy for heating and cooling buildings. The energy collected will provide between 80 and 100 percent of the heating and cooling requirements during the cool months and between one-half and two-thirds of the cooling requirements in the summer. Thermal energy storage will be provided to bridge the gap between cloudy and clear days.

Maag, W. L.↗

Public policy for solar heating and cooling

Recent analyses indicated that solar heating and cooling systems for residential buildings are nearly economically competitive with conventional fossil fuel or electric systems, the former having higher initial cost but a lower operating cost than the latter. The paper examines obstacles to the widespread acceptance and use of solar space conditioning systems and explores some general policies which could help to overcome them. The discussion covers such institutional barriers limiting the adoption of solar technologies as existing building codes, financing constraints, and organizational structure of the building industry. The potential impact of financial incentives is analyzed. It is noted that a tax incentive of 25% could speed the use of solar energy by 7 to 8 years and produce an 8% reduction in fossil fuel use by 1990. A preliminary incentive package which could be helpful in promoting solar energy both at federal and state levels is proposed, and the necessary incentive level is analysed.

Hirshberg, A. S.↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.