Search NASA⌕ Search

SEARCH · Search NASA

Results for “button cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CLOSEOUT REPORT FOR HYBRID SULFUR PRESSURIZED BUTTON CELL TEST FACILITY

This document is the Close-Out Report for design and partial fabrication of the Pressurized Button Cell Test Facility at Savannah River National Laboratory (SRNL). This facility was planned to help develop the sulfur dioxide depolarized electrolyzer (SDE) that is a key component of the Hybrid Sulfur Cycle for generating hydrogen. The purpose of this report is to provide as much information as possible in case the decision is made to resume research. This report satisfies DOE Milestone M3GSR10VH030107.0. The HyS Cycle is a hybrid thermochemical cycle that may be used in conjunction with advanced nuclear reactors or centralized solar receivers to produce hydrogen by watersplitting. The HyS Cycle utilizes the high temperature (>800 C) thermal decomposition of sulfuric acid to produce oxygen and regenerate sulfur dioxide. The unique aspect of HyS is the generation of hydrogen in a water electrolyzer that is operated under conditions where dissolved sulfur dioxide depolarizes the anodic reaction, resulting in substantial voltage reduction. Low cell voltage is essential for both high thermodynamic efficiency and low hydrogen cost. Sulfur dioxide is oxidized at the anode, producing sulfuric acid that is sent to the high temperature acid decomposition portion of the cycle. Sulfur dioxide from the decomposer is cycled back to electrolyzers. The electrolyzer cell uses the membrane electrode assembly (MEA) concept. Anode and cathode are formed by spraying a catalyst, typically platinized carbon, on both sides of a Proton Exchange Membrane (PEM). SRNL has been testing SDEs for several years including an atmospheric pressure Button Cell electrolyzer (2 cm{sup 2} active area) and an elevated temperature/pressure Single Cell electrolyzer (54.8 cm{sup 2} active area). SRNL tested 37 MEAs in the Single Cell electrolyzer facility from June 2005 until June 2009, when funding was discontinued. An important result of the final months of testing was the development of a method that prevents the formation of a sulfur layer previously observed in MEAs used in the Hybrid Sulfur Cycle electrolyzer. This result is very important because the sulfur layer increased cell voltage and eventually destroyed the MEA that is the heart of the cell. Steimke and Steeper [2005, 2006, 2007, 2008] reported on testing in the Single Cell Electrolyzer test facility in several periodic reports. Steimke et. al [2010] issued a final facility close-out report summarizing all the testing in the Single Cell Electrolyzer test facility. During early tests, significant deterioration of the membrane occurred in 10 hours or less; the latest tests ran for at least 200 hours with no sign of deterioration. Ironically, the success with the Single Cell electrolyzer meant that it became dedicated to long runs and not available for quick membrane evaluations. Early in this research period, the ambient pressure Button Cell Electrolyzer test facility was constructed to quickly evaluate membrane materials. Its small size allowed testing of newly developed membranes that typically were not available in sizes large enough to test in the Single Cell electrolyzer. The most promising membranes were tested in the Single Cell Electrolyzer as soon as sufficient large membranes could be obtained. However, since the concentration of SO{sub 2} gas in sulfuric acid decreases rapidly with increasing temperature, the ambient pressure Button Cell was no longer able to achieve the operating conditions needed to evaluate the newer improved high temperature membranes. Significantly higher pressure operation was required to force SO{sub 2} into the sulfuric acid to obtain meaningful concentrations at increased temperatures. A high pressure (200 psig), high temperature (120 C) Button Cell was designed and partially fabricated just before funding was discontinued in June 2009. SRNL completed the majority of the design of the test facility, including preparation of a process and instrument drawing (P&ID) and preliminary designs for the major components. SRNL intended to complete the designs and procure or fabricate the specialized equipment, including all wetted-parts for handling the SO{sub 2}/sulfuric acid reactants. The portion of the P&ID that included commercial equipment, standard tubing, controls, and structural systems was procured from a commercial partner (Giner Electrochemical Systems LLC). This report summarizes the objectives, preliminary design, and status of the test facility. At the time of this report, SRNL was continuing discussions with potential partners for transfer of the technology for use under other programs.

08 HYDROGEN↗

Challenges in practical button cell testing for hydrogen production from high temperature electrolysis of water

High temperature electrolysis of water using solid oxide electrochemical cells (SOEC) is a promising technology for hydrogen production with high energy efficiency and may promote decarbonization when coupled with renewable energy sources and excess heat from nuclear reactors. Over the past several decades there have been extensive scientific and engineering studies on cell materials and degradation behaviors that have greatly improved current density, decreased total resistance, and lowered degradation rates. Although the technology is now at a near-commercial level, maintaining consistency in cell testing and minimizing variance in practical testing environments is an often overlooked but crucial topic. To promote high quality data collection, testing procedures and balance of plant component details are extremely important to consider. This work discusses some key factors affecting the reproducibility of practical SOEC testing on the button cell level, namely, current collection layers, cell sealing procedures, the reliability of steam and hydrogen delivery systems, cell testing fixture design, and reduction procedures. To provide a baseline and a level of standardization for the SOEC community, this work also discloses details of the standard operating procedure and techniques adopted for o-SOEC testing at Idaho National Laboratory (INL).

08 HYDROGEN↗

LSM/YSZ Button Cell Tests in Cathode Air with Measured Cr Concentrations

A test fixture and methodology was developed for testing anode-supported SOFC button cells downstream from a chromia pellet at a prescribed temperature for qualitative control of Cr volatility. An alumina foam coated with Cr-gettering Na2CO3 was placed downstream from the cell to capture Cr species from the cathode air by reacting to form Na2CrO4. The coating and reaction product are both water soluble, facilitating dissolution from the porous substrate for subsequent ICP analysis to determine the Cr concentration in the resulting solution. The mass of collected Cr is used to calculate the average Cr concentration in the known volume of air used during the test. Cells with LSM/YSZ cathodes were electrochemically tested for 600 to 1000 hours with chromia pellets at varying conditions of temperature and humidity to elicit varying levels of Cr volatility. Molar Cr concentrations of only 40 to 170 ppt caused ~4%/kh degradation.

Hardy, John S.↗

Electrochemical Performance and Stability of the Cathode for Solid Oxide Fuel Cells IV. On the Ohmic loss in anode supported button cells with LSM or LSCF cathodes

Anode-supported solid oxide fuel cells (SOFC) with a variety of YSZ electrolyte thicknesses were fabricated by tape casting and lamination. The preparation of the YSZ electrolyte tapes with various thicknesses was accomplished by using doctor blades with different gaps between the precision machined, polished blade and the casting surface. The green tape was cut into discs, sintered at 1385°C for 2 h, and subsequently creep-flattened at 1350°C for 2 h. Either LSCF with an SDC interlayer or LSM+YSZ composite was used as the cathode material for the fuel cells. The ohmic resistances of these anode-supported fuel cells were characterized by electrochemical impedance spectroscopy at temperatures from 500°C to 750°C. A linear relationship was found between the ohmic resistance of the fuel cell and the YSZ electrolyte thickness at all the measuring temperatures for both LSCF and LSM+YSZ cathode fuel cells. The ionic conductivities of the YSZ electrolyte, derived for the fuel cells with LSM+YSZ or LSCF cathodes, were independent of the cathode material and cell configuration. The ionic conductivities of the YSZ electrolyte was slightly lower than that of the bulk material, possibly due to Ni-doping into the electrolyte. The fuel cell with a SDC interlayer and LSCF cathode showed larger intercept resistance than the fuel cell with LSM+YSZ cathode, which was possibly due to the imperfect contact between the SDC interlayer and the YSZ electrolyte and the migration of Zr into the SDC interlayer to form an insulating solid solution during cell fabrication. Calculations of the contribution of the YSZ electrolyte to the total ohmic resistance showed that YSZ was still a satisfactory electrolyte at temperatures above 650°C. Explorations should be directed to reduce the intercept resistance to achieve significant improvement in cell performance.

30 DIRECT ENERGY CONVERSION↗

Factors Affecting Limiting Current in Solid Oxide Fuel Cells or Debunking the Myth of Anode Diffusion Polarization

Limiting current densities for solid oxide fuel cells were measured using both button cells and a flow-through cell. The cell anodes were supplied mixtures of humidified hydrogen and various inert gasses. It was demonstrated that the true limiting current in flow-through cells is reached when either: the hydrogen is nearly or completely depleted at the anode-electrolyte interface near the outlet; or when the concentration of steam at that interface becomes high enough to interfere with adsorption or transport of the remaining hydrogen near the triple-phase boundaries. Choice of inert gas had no effect on limiting currents in the flow-through tests, indicating that diffusion within the porous anode had no significant effect on cell performance at high currents. In the button cells, the apparent limiting currents were significantly changed by the choice of inert gas, indicating that they were determined by diffusion through the bulk gas within the support tube. It was concluded that the apparent limiting currents measured in button cells are influenced more by parameters of the experimental setup, such as the proximity of the fuel tube outlet, than by the physical properties of the anode.

08 HYDROGEN↗

FCET Solid Oxide Fuel Cell Testing and Development (CRADA 526) (Final Report)

Pacific Northwest National Laboratory (PNNL) tested electrolyte coatings from Fuel Cell Enabling Technologies, Inc. (FCET) for use in solid oxide fuel cells (SOFCs). The key technology held by FCET is a process to deposit thin layers of oxide materials, less than 1 μm in thickness. The range of possible materials that can be deposited with their method is broad, but this project focused on the gadolinium-doped ceria (GDC) and yttria-stabilized zirconia (YSZ) electrolytes for SOFCs. Thin, gas tight electrolyte membranes have been a long-sought target in SOFC research. The thinner the electrolyte, the lower the cell resistance, and the higher performance of the cell (or the lower the operating temperature). A YSZ thickness of 1 μm would be a step change from the state-of-the-art, tape-cast electrolytes (~10 μm). An in-house prototype SOFC stack from FCET was first tested. The sealing geometry of the prototype stack was determined to be problematic, and testing shifted to button cells. Anode-supported solid oxide electrolysis cell (SOEC) button cells without an electrolyte layer were produced at PNNL and sent to FCET for coating with electrolyte. Three cells were tested with a gadolinium-doped ceria (GDC) electrolyte applied via spin coating. GDC was chosen for its conductivity at lower temperatures than YSZ. All three cells failed during initial reduction under hydrogen at 600°C. Testing then shifted to YSZ, which is the standard SOFC electrolyte. Several button cells were coated with YSZ and examined with scanning electron microscopy (SEM). A promising coating of ~1 mm thickness was observed under SEM. A similarly coated button cell was tested and failed similarly to previous tests during reduction at 600°C. The YSZ coating appeared dense and uniform in SEM analysis. The roughness of the underlying Ni/YSZ anode is on the order of 1 μm, and that may have compromised the gas-tightness of the coating. Further development is warranted to understand and refine the coating process. Thin YSZ applied via this spin-coating technique could be used as a low-cost, drop-in replacement in large-scale SOFC manufacturing processes, improving cell performance and lowering the cost per watt of SOFCs.

30 DIRECT ENERGY CONVERSION↗

Scaleup and manufacturability of symmetric-structured metal-supported solid oxide fuel cells

Metal-supported solid oxide fuel cells with symmetric architecture, having metal supports on both sides of the cell, are scaled up from button cell size to large 50 cm 2 active area cell size. The cells remain flat after sintering assisted by the symmetric structure. Equivalent performance is achieved for button cells and large cells, and thermal cycling and redox cycling tolerance are demonstrated for the large cells. The catalyst infiltration process is improved to enable high-throughput manufacturing. The cumbersome lab-scale molten nitrate infiltration process is replaced with a room-temperature process in which a shelf-stable aqueous solution of nitrate salts is applied to the cell by spraying, painting, or other scalable techniques. Here, a fast-ramp thermal conversion of the nitrate salts to the final oxide catalyst composition is implemented, allowing many infiltration cycles to be accomplished in a single work shift. Increasing the number of infiltration cycles from 5 to 10 led to an increase in peak power density from approximately 0.3 to 0.52 W cm -2 .

25 ENERGY STORAGE↗

HYBRID SULFUR ELECTROLYZER DEVELOPMENT FY09 SECOND QUARTER REPORT

The primary objective of the DOE-NE Nuclear Hydrogen Initiative (NHI) is to develop the nuclear hydrogen production technologies necessary to produce hydrogen at a cost competitive with other alternative transportation fuels. The focus of the NHI is on thermochemical cycles and high temperature electrolysis that can be powered by heat from high temperature gas reactors. The Savannah River National Laboratory (SRNL) has been tasked with the primary responsibility to perform research and development in order to characterize, evaluate and develop the Hybrid Sulfur (HyS) thermochemical process. This report documents work during the first quarter of Fiscal Year 2009, for the period between January 1, 2009 and March 31, 2009. The HyS Process is a two-step hybrid thermochemical cycle that is part of the 'Sulfur Family' of cycles. As a sulfur cycle, it uses high temperature thermal decomposition of sulfuric acid to produce oxygen and to regenerate the sulfur dioxide reactant. The second step of the process uses a sulfur dioxide depolarized electrolyzer (SDE) to split water and produce hydrogen by electrochemically reacting sulfur dioxide with H{sub 2}O. The SDE produces sulfuric acid, which is then sent to the acid decomposer to complete the cycle. The DOE NHI program is developing the acid decomposer at Sandia National Laboratory for application to both the HyS Process and the Sulfur Iodine Cycle. The SDE is being developed at SRNL. During FY05 and FY06, SRNL designed and conducted proof-of-concept testing for a SDE using a low temperature, PEM fuel cell-type design concept. The advantages of this design concept include high electrochemical efficiency, small footprint and potential for low capital cost, characteristics that are crucial for successful implementation on a commercial scale. During FY07, SRNL extended the range of testing of the SDE to higher temperature and pressure, conducted a 100-hour longevity test with a 60-cm{sup 2} single cell electrolyzer, and designed and built a larger, multi-cell stack electrolyzer. During FY08, SRNL continued SDE development, including development and successful testing of a three-cell electrolyzer stack with a rated capacity of 100 liters per hour. The HyS program for FY09 program will address improving SDE performance by focusing on preventing or minimizing sulfur deposition inside the cell caused by SO{sub 2} crossover, reduction of cell voltage for improved efficiency, an extension of cell operating lifetime. During FY09 a baseline technology development program is being conducted to address each of these issues. Button-cell (2-cm{sup 2}) and single cell (60-cm{sup 2}) SDEs will be fabricated and tested. A pressurized button-cell test facility will be designed and constructed to facilitate addition testing. The single cell test facility will be upgraded for unattended operation, and later for operation at higher temperature and pressure. Work will continue on development of the Gas Diffusion Electrode (GDE), or Gap Cell, as an alternative electrolyzer design approach that is being developed under subcontract with industry partner Giner Electrochemical Systems. If successful, it could provide an alternative means of preventing sulfur crossover through the proton exchange membrane, as well as the possibility for higher current density operation based on more rapid mass transfer in a gas-phase anode. Promising cell components will be assembled into membrane electrode assemblies (MEAs) and tested in the single cell test facility. Upon modification for unattended operation, test will be conducted for 200 hours or more. Both the button-cell and modified single cell facility will be utilized to demonstrate electrolyzer operation without sulfur build-up limitations, which is a Level 1 Milestone.

08 HYDROGEN↗

Lightweight Solid Oxide Cell Design for Ammonia-fed SOFC Systems

A lightweight solid oxide fuel cell (SOFC) was developed by OxEon Energy that demonstrates the potential for increased specific power (kW/g) suitable for the requirements of electric Vertical Take-off and Landing (eVTOL) applications. Fuel flexibility was demonstrated in button cells and stacks using both legacy electrolyte-supported SOFC structure and the lightweight structure. Button cell and stack performance was nearly identical among hydrogen, ammonia, and reformed natural gas. Durability testing shows similarly stable performance in each fuel. A button cell test in ammonia at 800 °C using the lightweight cell structure measured area specific resistance (ASR) of 0.25 Ω-cm2 in H2/N2 and NH3 fuel feeds and showed a peak power density of 0.98 W/ cm2 in NH3 fuel. Short term hold at 0.7 V showed stable performance.

Pike, Jenna↗

Faraday: A High-temperature Electrolysis Data Explorer

Faraday is a high-temperature electrolysis data visualization tool, which reveals the performance of various button cells under test conditions. These tests and the resulting analytics on their data constitute a state of the industry as the US Department of Energy pushes for the production of hydrogen. Faraday leverages the Idaho National Laboratory's DeepLynx data warehouse to standardize and query button cell data. Faraday programmatically accesses this data in DeepLynx by traversing the schema, represented by a custom ontology. The user interface queries DeepLynx for timeseries data associated with specific button cells in the warehouse, and renders them using JavaScript charts. Additional charting and data analysis techniques are made possible by an auxiliary Python server.

Woodruff, Nathan↗

Novel Sulfur-Tolerant Anodes for Solid Oxide Fuel Cells

One of the unique advantages of SOFCs over other types of fuel cells is the potential for direct utilization of hydrocarbon fuels (it may involve internal reforming). Unfortunately, most hydrocarbon fuels contain sulfur, which would dramatically degrade SOFC performance at parts-per-million (ppm) levels. Low concentration of sulfur (ppm or below) is difficult to remove efficiently and cost-effectively. Therefore, knowing the exact poisoning process for state-of-the-art anode-supported SOFCs with Ni-YSZ cermet anodes, understanding the detailed anode poisoning mechanism, and developing new sulfur-tolerant anodes are essential to the promotion of SOFCs that run on hydrocarbon fuels. The effect of cell operating conditions (including temperature, H{sub 2}S concentration, cell voltage/current density, etc.) on sulfur poisoning and recovery of nickel-based anode in SOFCs was investigated. It was found that sulfur poisoning is more severe at lower temperature, higher H{sub 2}S concentration or lower cell current density (higher cell voltage). In-situ Raman spectroscopy identified the nickel sulfide formation process on the surface of a Ni-YSZ electrode and the corresponding morphology change as the sample was cooled in H{sub 2}S-containing fuel. Quantum chemical calculations predicted a new S-Ni phase diagram with a region of sulfur adsorption on Ni surfaces, corresponding to sulfur poisoning of Ni-YSZ anodes under typical SOFC operating conditions. Further, quantum chemical calculations were used to predict the adsorption energy and bond length for sulfur and hydrogen atoms on various metal surfaces. Surface modification of Ni-YSZ anode by thin Nb{sub 2}O{sub 5} coating was utilized to enhance the sulfur tolerance. A multi-cell testing system was designed and constructed which is capable of simultaneously performing electrochemical tests of 12 button cells in fuels with four different concentrations of H{sub 2}S. Through systematical study of state-of-the-art anode-supported SOFC button cells, it is seen that the long-term sulfur poisoning behavior of those cells indicate that there might be a second-stage slower degradation due to sulfur poisoning, which would last for a thousand hour or even longer. However, when using G-18 sealant from PNNL, the 2nd stage poisoning was effectively prohibited.

01 COAL, LIGNITE, AND PEAT↗

XPS Studies of LSCF Interfaces after Cell Testing

The motivation of this investigation is to explore the possibility of using the depth profile capability of XPS to study interfaces after SOFC button cell testing. The literature uses XPS to study various cathode materials but has devoted little to the understanding of various cathode interfaces especially after testing. In this work, an SOFC button cell is first tested, and then, the LSCF cathode, barrier layer, and electrolyte are sputtered away to study the behavior of different interfaces. This work has shown that some elements have moved into other layers of the SOFC cell. It is argued that the migration of the elements is partly due to a redeposition mechanism after atoms are sputtered away, while the rest is due to interdiffusion between the SDC and YSZ layers. However, additional work is needed to better understand the mechanism by which atoms move around at different interfaces. In conclusion, the cell electrochemical performance is also discussed in some details but is not the focus.

42 ENGINEERING↗

Development of a Thermal Spray, Redox Stable, Ceramic Anode for Metal Supported SOFC

In this program, GE global research and GE fuel cells in Malta conducted thermal spray optimization experiments, initially focusing on a well-established ceramic anode formulation, lanthanum strontium titanate combined with gadolinium doped ceria. Powder engineering work was conducted both internally and with vendors to develop repeatable, stable, and flowable thermal spray feedstocks. Agglomerate sintering was conducted in the last phase of the project, building on earlier program work, and was used to increase run stability during the longer scaled up runs for the 410 cm 2 cells. Further powder engineering would be needed to fully design a powder ready for full scale manufacturing. During preliminary work on the LST-GDC electrodes, GE demonstrated 100 cm 2 stacks enduring multiple redox cycles with limited impact. Another key finding on the project was the identification of process conditions for two component ceramic anode thermal spray without the formation of phase impurities which were present in all early work on the program. GE global research and West Virginia University screened a large number of ceramic anode formulations, focused on identifying materials with ideal materials properties for use in SOFC anodes. In addition, synthetic scaling research was conducted to increase powder synthesis batch size several orders of magnitude during the course of project work. West Virginia University was able to show button cells using two component ceramic anodes which produced > 890 mW/cm 2 and even a single component SOFC button demonstrating > 1 W/cm 2 performance. These button cell tests show the great potential of these redox stable materials. Down-selected ceramic anode formulations were combined with the optimized thermal spray process methods to first demonstrate multiple groups of 100 cm 2 SOFC stacks able to achieve the power density goals for the project. GE research also quickly investigated the performance of a subset of these formulations on long term degradation tests and assessed their performance on simulated natural gas reformate. In the final phase of the program, scaling activities were employed to translate from the 100cm2 process up to 410 cm 2 . Two large format 10-cell stack tests were completed, and one of these stacks produced 0.987 kW which is one of the highest power demonstrations of ceramic anode, metal support, SOFC technology known to GE. These ceramic anode stacks had been produced with all other materials in the stack held constant, demonstrating the flexibility of the thermal spray process in scaling to very large electrode size.

30 DIRECT ENERGY CONVERSION↗

Physics-Based Model to Represent Membrane-Electrode Assemblies of Solid-Oxide Fuel Cells Based on Gadolinium-Doped Ceria

This paper reports a physics-based model that predicts membrane-electrode assembly (MEA) performance of solid-oxide fuel cells (SOFCs) with Ce 0.9 Gd 0.1 O 2− δ (GDC10) electrolyte membranes. The paper derives self-consistent thermodynamic and transport properties for GDC1o mobile charged defects (oxide vacancies and reduced-ceria small polarons) by fitting published measurements of oxygen non-stoichiometry and conductivity over ranges of temperature and O 2 partial pressures. The button-cell model is applied to evaluate how mixed ionic-electronic conductivity influences the performance of an SOFC MEA with a GDC10 electrolyte sandwiched between a porous, composite Ni-GDC10 anode and a porous, composite cathode of Sm 0.5 Sr 0.5 CoO 3− δ (i.e., SSC) and GDC10. SSC properties are also derived by fitting published conductivity and oxygen non-stoichiometry measurements. Mixed conductivity of GDC10 and competing charge transfer reactions at both electrodes reduce open circuit voltages due to leakage current and buildup of defect concentrations at electrode-electrolyte interfaces. To fit polarization data, the button-cell model includes heterogeneous reaction rates for defect incorporation on the GDC10 surface along with Butler–Volmer expressions derived for competing charge transfer reaction rates from rigorous analyses assuming rate-limiting, elementary charge transfer reactions for each electrode. The calibrated MEA model can support rigorous SOFC modeling with GDC10 electrolytes over the range of conditions within a fully operating cell.

Electrochemistry↗

Anode Interactions with Coal Gas Contaminants

This report describes efforts to characterize the interactions nickel anodes with phosphorus in coal gas using three different button cell configurations to emphasize particular degradation modes. Important parameters addressed included contaminant concentration, temperature, reaction time, fuel utilization, and current density. In addition, coupon tests in flow-through and flow-by arrangements were conducted to complement cell tests. The studies have involved extensive electrochemical testing using both dc and ac methods. Post-test analyses to determine the composition and extent of nickel modification are particularly important to understanding reactions that have occurred. This report also provides a thermodynamic assessment of contaminant reactions with nickel in a coal gas environment with regard to alteration phase formation. Contaminants addressed were phosphorus, arsenic, sulfur, selenium, and antimony. Phosphorus was found to interact strongly with nickel and result in extensive alteration phase formation, consistent with expectations based on thermodynamic properties. Even in button cell tests where the fuel utilization was low, phosphorus was found to be nearly completely captured by the nickel anode. For anode-supported cells, an important degradation mode involved loss of electronic percolation, the result of nickel phosphide formation, grain growth, and inducement of micro-fractures within the anode support. Even with excessive anode support conversion, electrochemical degradation rates were often very low. This is attributed to a “shadowing effect,” whereby a dense structure such as current leads prevent phosphorus from reacting with the nickel directly underneath. This effect maintains an electrical pathway to the active interface, and allows the cell to operate with minimal degradation until the anode is essentially completely consumed. In a planar stack, ribs on the interconnect plate would be expected to provide this conductive pathway in the event of phosphorus exposure. When phosphorus interactions proceeded to the active interface, most easily observed in tests with electrolyte-supported cells having a thin anode, the electrochemical performance decreased considerably.

01 COAL, LIGNITE, AND PEAT↗