Cesium Removal from AP-105 Hanford Tank Waste Using Spherical Resorcinol Formaldehyde Resin

Spherical resorcinol formaldehyde (SRF) resin is planned to be used to remove cesium (137Cs) from the aqueous phases of Hanford tank wastes in preparation for their vitrification at the Waste Treatment and Immobilization Plant. SRF is an elutable organic ion exchanger that is projected to be used in up to 30multiple process cycles (load/elute/regeneration) before being disposal . Only two full process cycles have been tested using SRF on Hanford tank waste. This paper describes the test results of six complete load/elute cycles using the SRF in a lead/lag column format with 12 liters of Hanford tank waste supernatant collected from Tank AP-105. The testing exposed the SRF to the combined sources of degradation: chemical attack from dissolved oxygen, nitric acid, and tank waste components; physical stress from resin expansion and contraction; and beta and gamma radiolytic exposure. Process conditions, dictated by Washington River Protection Solutions, featured loading until the lag column effluent reached 10% of the waste acceptance criteria (a Cs decontamination factor of 6,000). Under these conditions the lead column was nearly fully loaded and the lag column was loaded with about 20% of the input Cs. Variations in process flowrates and elution volumes were investigated as part of the testing. Characteristics examined included degradation with cycling, mass transfer zones as a function of flowrate, Cs leakage into the ensuing process cycle, and analyte mass fractionation.

spherical resorcincol formaldehyde, ion exchange, ↗

Tank Closure Cesium Removal Project CST Simulant Cesium Batch Contact Kinetics Test Results and Column Performance Predictions

To evaluate the cesium removal capabilities of the caustic-washed R9120-B version of crystalline silicotitanate (CST) ion exchange media from Savannah River Site (SRS) waste during Tank Closure Cesium Removal (TCCR) column processing, batch contact kinetics tests were performed at 23 °C in SRS Average simulant. Cesium loading kinetics data was also collected (in current and previous testing; King, et al., 2018a) using the same simulant for an older CST sample (IE- 911) which was caustic-washed by the vendor many years ago and was recently retrieved from drums stored at SRS. (Note that R9120-B and IE-911 are believed to be identical materials, after the R9120-B was caustic washed by SRNL, and differ only by particle size and manufacturing date, and thus can be considered different batches). Although cesium loading kinetics testing can be conducted more rigorously using dynamic column tests, the batch contact method requires less simulant and considerably less experimental effort. Average percent removal data for batch contact samples for the two CST batches are provided in Table ES-1. Faster cesium uptake was observed with IE-911, although the loading rates for the two media batches were similar. After 5.5 hours of CST contact, 81% cesium removal was observed with R9120-B versus 86% removal with IE-911. Although these differences are small, the trend is consistent across the timed results, with the larger bead material always loading slower. These seemingly small differences in percent removal are believed to have a large impact on the column performance. Cesium loading curves for the two CST batches are provided in Figure ES-1 below. Faster cesium loading with IE-911 CST is presumed to be associated with the smaller average particle diameter (408 μm mean volume diameter) versus R9120-B (572 μm diameter). Cesium loading kinetic data was needed to conduct column performance comparisons (i.e., model predictions) for the two CST batches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal and Hydraulic Performance Comparisons of CST Ion Exchange Media Batches in Support of the Tank Closure Cesium Removal Project - 20522

Three batches of Crystalline Silicotitanate (CST) ion exchange media have been evaluated for cesium removal efficiency from a Savannah River Site (SRS) High Level Waste (HLW) supernate simulant in support of the Tank Closure Cesium Removal (TCCR) Project, which involves at-tank column waste treatment. Results will be utilized to select the CST media batch to be added to the next TCCR unit columns. Two of the CST media samples were recent production batches and the third was an archived batch studied extensively at SRS nearly two decades ago. The archived CST batch had a significantly smaller average particle diameter than more recent batches. Small-scale (∼23 mL), side-by-side column tests were conducted at 35 deg. C with each of the CST batches using the same simulant at flow rates near 1.2 mL/min (3.0-3.4 CST bed volumes/hr). The cesium ion exchange column performance results were lower than expected for all three CST batches, but the data indicated that 30% more simulant volume and 40% more equivalent CST bed volumes of solution can be processed with the older CST batch prior to reaching the 50% cesium breakthrough point than can be processed with the newer CST batches. Hydraulic evaluations of the CST columns were also conducted in simulant at 24 deg. C to determine the impact of the different particle size distributions and associated bed porosities on frictional pressure drop under dynamic flow conditions. Higher differential pressure drops were observed with the archived CST batch relative to recent production batches, due to the smaller particle size distribution and the packing characteristics of the archived batch. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING AN ION EXCHANGE PROCESS FOR CESIUM REMOVAL FROM ALKALINE RADIOACTIVE WASTE SOLUTIONS

The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ROBUSTNESS OF THE CSSX PROCESS TO FEED VARIATION: EFFICIENT CESIUM REMOVAL FROM THE HIGH POTASSIUM WASTES AT HANFORD

This contribution finds the Caustic-Side Solvent Extraction (CSSX) process to be effective for the removal of cesium from the Hanford tank-waste supernatant solutions. The Hanford waste types are more challenging than those at the Savannah River Site (SRS) in that they contain significantly higher levels of potassium, the chief competing ion in the extraction of cesium. By use of a computerized CSSX thermodynamic model, it was calculated that the higher levels of potassium depress the cesium distribution ratio (D{sub Cs}), as validated to within {+-}11% by the measurement of D{sub Cs} values on various Hanford waste-simulant compositions. A simple analog model equation that can be readily applied in a spreadsheet for estimating the D{sub Cs} values for the varying waste compositions was developed and shown to yield nearly identical estimates as the computerized CSSX model. It is concluded from the batch distribution experiments, the physical-property measurements, the equilibrium modeling, the flowsheet calculations, and the contactor sizing that the CSSX process as currently formulated for cesium removal from alkaline salt waste at the SRS is capable of treating similar Hanford tank feeds, albeit with more stages. For the most challenging Hanford waste composition tested, 31 stages would be required to provide a cesium decontamination factor (DF) of 5000 and a concentration factor (CF) of 2. Commercial contacting equipment with rotor diameters of 10 in. for extraction and 5 in. for stripping should have the capacity to meet throughput requirements, but testing will be required to confirm that the needed efficiency and hydraulic performance are actually obtainable. Markedly improved flowsheet performance was calculated based on experimental distribution ratios determined for an improved solvent formulation employing the more soluble cesium extractant BEHBCalixC6 used with alternative scrub and strip solutions, respectively 0.1 M NaOH and 0.010 M boric acid. The improved solvent and flowsheet can meet minimum requirements (DF = 5000 and CF = 2) with 15 stages or more ambitious goals (DF = 40,000 and CF = 15) with 19 stages. Thus, a modular CSSX application for the Hanford waste seems readily obtainable with further short-term development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 9H Salt Solution Supernatant Characterization in Support of Potential Operating Strategies of Tank 9H Supernatant Through the Tank Closure Cesium Removal System

Savannah River Remediation (SRR) recently initiated an ion exchange process to remove radioactive cesium from dissolved salt solution in Tank 10H, known as Tank Closure Cesium Removal (TCCR). As part of that ongoing campaign, the salt in Tank 9H will be dissolved and transferred to Tank 10H for processing through the TCCR system, and SRR requested the characterization of the dissolved salt solution in Tank 9H prior to the transfer to Tank 10H. On July 18, 2019, Savannah River Remediation Engineering (SRR-E) delivered two variable depth Tank 9H salt solution samples, identified as samples HTF-9-19-74 and HTF-9-19-75 (combined total sample volume of about 400 mL) to the Savannah River National Laboratory (SRNL) for characterization. These two Tank 9H variable depth samples (HTF-9-19-74 and HTF-9-19-75 taken at ~180” and 42”, respectively) were retrieved from Riser 7 after hydro-lancing activities were complete. Approximately 4200 gallons of water were added to the tank during this activity. This report presents the analytical characterization results for the Tank 9H salt solution variable depth samples HTF-9-19-74 and HTF-9-19-75 and contains mainly the filtrate analytical results for anions, elements, mass spectral data, total cesium characterization results and select radionuclide results, along with the X-ray diffraction characterization of the solid fractions from the liquid /solid separation of the variable depth salt solutions. Most of these analyses were performed in duplicate with the percent relative standard deviation (%RSD), a measure of the variability between each duplicate data set expressed as a percentage, used to estimate the analytical result quality for each analyte.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pretreatment of Crystalline Silicotitanate (CST) and development of a digestion standard to support Tank Closure Cesium Removal (TCCR)

In support of Savannah River Remediation’s (SRR) deployment of an ion exchange process to remove radioactive cesium from waste supernate, referred to as the Tank Closure Cesium Removal (TCCR) process, SRNL was tasked with validating the field protocol for pretreating the crystalline silicotitanate (CST) material to be used in the columns, preparing CST for use in in-tank batch contact testing, as well as developing a digestion standard to verify complete dissolution of the CST prior to characterization after each in-tank batch contact test. A procedure (SRNL L29 Manual, ITS-0229) was developed to document the protocol for pretreating CST utilizing conditions similar to what will be performed in the field. Analysis of material pretreated following the procedure confirmed similar conversion to the Na+ form of the resin as had been obtained previously. Portions of the batch of material pretreated according to the developed protocol were also used for development of a digestion standard. Results from digestion and analysis of this standard were used to establish a set of control limits for the measured Ti, Zr, and Nb concentrations in digested CST material. An aliquot of this standard CST material will be digested and analyzed alongside each in-tank batch contact sample, and the measured concentrations of Ti, Zr, and Nb will be compared against the established control limits to confirm complete digestion has occurred.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CST R9120-B 30x60 Media Pretreatment and Digestion Standard Development to Support Tank Closure Cesium Removal 1A (TCCR-1A) Operations

In support of continued operations of Savannah River Remediation’s (SRR) ion exchange process to remove radioactive cesium from Savannah River Site (SRS) dissolved saltcake, referred to as the Tank Closure Cesium Removal 1A process (TCCR-1A; containing the second set of at-tank ion exchange columns), SRNL was tasked with: 1) validating the field protocol planned for pretreating the crystalline silicotitanate (CST) ion exchange media to be used in the columns, 2) preparing CST media for use in in-tank batch contact testing, and 3) developing a digestion standard to verify complete CST dissolution prior to characterization following each in-tank batch contact test. A procedure (SRNL L29 Manual, ITS-0229) was developed previously in support of the TCCR Demonstration (which contained the first set of ion exchange columns) based on evaluations of a different CST production lot with a larger particle size range to document the protocol for pretreating CST utilizing conditions similar to what will be performed in the field.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tank Closure Cesium Removal at Savannah River Site - 19604

Savannah River Remediation (SRR) has developed a supplemental at-tank ion exchange capability for the removal of cesium from liquid salt waste. Building on the development of previous ion exchange initiatives and the experience of commercial nuclear plant decontamination services, and following the disaster response associated with Fukushima, the technology has matured to deploy a modular at-tank treatment system for the selective removal of cesium from bulk salt waste. If feasible, this Tank Closure Cesium Removal (TCCR) initiative would provide a supplemental treatment capability to existing and future salt processing and improve confidence in supporting the desired acceleration of waste retrieval and tank closure efforts. In addition to accelerating waste retrieval and tank closure activities, demonstration of this capability has several other benefits. Deployment of commercially available technologies with minor modification can expand Department of Energy (DOE) utilization of commercially supplied treatment processes. This 'at-tank' treatment system could be modified to evaluate and demonstrate removal of other radioactive constituents (strontium, technetium, iodine, etc.) of bulk waste. The modular aspect of this capability can allow for additional units to be delivered and deployed at SRS, as well as, provide supplemental treatment capabilities for waste treatment at other DOE sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ZAM Modeling Study to Support the Tank Closure Cesium Removal (TCCR) 1A Unit

Currently at the Savannah River Site (SRS), the Tank Closure Cesium Removal (TCCR) is an “at-tank” process designed to remove cesium from aqueous tank waste. Cesium will be removed by ion exchange using the engineered IONSIV® R9120 form of Crystalline Silicotitanate (CST) media. The current TCCR design has two columns online in a lead-lag configuration to optimize media usage and achieve the target decontamination. Once the lead column is saturated with cesium, it will be removed from service, the lag column will rotate into the lead position, and a new column with fresh ion-exchange media will be placed into the lag position. The TCCR process for cesium removal from Tank 10H is detailed in X-SOW-H- 00002. Demonstration of the system began in early calendar year 2019 with two batches of salt solution generated by dissolving saltcake in Tank 10H, followed by processing of these batches through the TCCR system. A third TCCR Tank 10H dissolved saltcake batch is scheduled for processing soon. Upon completion of the demonstration with Tank 10H dissolved saltcake, Tank 9H salt solution will be transferred to Tank 10H and subsequently processed through the TCCR unit with new CST media (referred to as R9120-B 30x60) added to new IX columns. The TCCR processing campaign of Tank 9H salt solution is referred to as TCCR-1A .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of feed variability on cesium removal with multiple actual waste samples from the Hanford site

Here, the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. This lot of material was found to have superior performance in comparison to historic batches of CST. Ion exchange column and batch contact testing with supernate from Hanford tanks AP-105, AP-107 and AW-102 was performed to assess the impact of feed variability on system performance. These tests demonstrated that batch contact measurements provide a reasonable prediction of column capacities with some deviation in performance attributed to column dynamics. In addition, the variability in CST capacity for cesium in the various actual waste samples does not track with historical understanding of the competing cations, suggesting that tank waste samples contain other components that may significantly impact cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing of Crystalline Silicotitanate to Support Tank-Side Cesium Removal System Operations - 20458

The direct feed of waste from the Hanford tank farms to the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant requires an intermediate treatment step that prepares the waste for vitrification. Washington River Protection Solutions (WRPS) selected a near-tank treatment system known as the Tank-Side Cesium Removal (TSCR) system to perform the required intermediate treatment functions. The approach in the TSCR system is to filter waste supernatant with a sintered metal dead-end filter and then use a series of ion exchange columns to remove cesium; this system has several similarities to the Tank Closure Cesium Removal system that has been deployed on the Savannah River Site. The ion exchange media proposed for use is crystalline silicotitanate (CST), which is a non-elutable media with a high affinity for cesium. Because the media is non-elutable, loaded columns will be blown down with compressed air, moved into interim storage, and replaced with new columns when cesium capacity is reached. The assumed extent and rate of drying that could be achieved in the TSCR column geometry lacked confirmation by experimental data. In addition, once the columns are loaded with cesium, they generate flammable gases (primarily hydrogen) via radiolysis acting on any resident liquids, i.e., moisture, remaining in the media bed. An assessment of available information on CST concluded that gas generation data that bounds expected operational conditions were needed to support the TSCR system safety basis and planned operations. Working with WRPS, Pacific Northwest National Laboratory (PNNL) designed and conducted testing with CST media to address the need for (a) representative in-column drying data, and (b) bounding flammable gas generation data. Drying testing was performed using a full-height column with a diameter of approximately 2 inches with injected air at temperatures of 18 deg. C and 30 deg. C. Gas generation testing was conducted in an engineered bunker that allowed simultaneous irradiation of up to eight samples at a time. These two experimental approaches used at PNNL for the CST testing are summarized and the major outcomes are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from AP-106 Tank Waste Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operated by Washington River Protection Solutions, LLC, prepares Hanford waste tank supernate feeds for the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant (WTP). In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange (IX), allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is <3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST), manufactured by Honeywell UOP, LLC (product IONSIV R9140-B), was selected as the ion exchange media for TSCR.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Qualification of Processing Batches for Tank Closure Cesium Removal Through In-Tank Batch Contact Testing - 20470

The Tank Closure Cesium Removal (TCCR) process at the Savannah River Site (SRS) is currently processing waste from Tank 10H, generating decontaminated salt solution that is sent to Tank 11H. Transfers out of Tank 11H are then disposed of on site as a grout wasteform in the SRS Saltstone Processing Facility. This is a full-scale demonstration of the use of Crystalline Silicotitanate (CST) for the decontamination of aqueous nuclear waste supernate. CST primarily removes cesium from the high sodium alkaline feed, but also adsorbs strontium, actinides, and some other trace metals. The TCCR unit is an at-tank set of four ion exchange columns, with two typically being operated in series during waste processing. Tank 10H is serving a dual function as both the salt dissolution tank as well as the feed tank for the TCCR system. Prior to operation of TCCR, Tank 10H must undergo dissolution campaigns, dissolving the salt cake to form an aqueous salt solution (supernate). After each dissolution campaign, the supernate created must be qualified prior to processing through the TCCR system. Qualification includes detailed characterization of the supernate as well as in-tank batch contact tests to determine the equilibrium loading of Cs-137 on the CST ion exchange media (IONSIV{sup TM} R9120-Ba). In support of the in-tank batch contact testing, Savannah River National Laboratory (SRNL) developed a CST sample holder, also referred to as a 'tea-bag', to hold a measured amount (∼0.1 grams) of pretreated CST between stainless steel screens. The tea-bag fits within a standard stainless steel sample vial that has been modified to allow the flow of supernate to the CST. This sample holder is then immersed in the waste tank allowing free contact between the CST beads and the surrounding liquid, at an effectively infinite liquid-to-solid phase ratio. A pair of tea-bags are deployed in the tank for a period of 10 days for each batch, after which the CST is recovered, digested, and analyzed to determine the loading of cesium isotopes on the CST. This result then supports the TCCR column thermal loading limits for processing as part of the TCCR safety basis. This paper will discuss the design and testing of the CST sample holder, as well as results from the first few batches of waste qualified and subsequently processed through the TCCR system. In addition, results from analyses of Tank 11H samples, showing decontamination of the product will be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion-Exchange Modeling of Crystalline Silicotitanate for Cesium Removal - 20283

The Tank Closure Cesium Removal (TCCR) system is a Savannah River Site (SRS) demonstration 'at-tank' process designed to remove {sup 137}Cs from the high-level aqueous tank waste so that the decontaminated solution can be disposed as low-level waste. Cesium is removed by ion exchange (IX) columns using engineered IONSIV{sup TM} R9120-B form of the Crystalline Silicotitanate (CST) media. The TCCR system is deployed at Tanks 10 and Tank 11 in the SRS H Tank Farm. Water is added to the salt-cake in Tank 10 H to dissolve it. The dissolved salt solution waste is pumped out of Tank 10H (feed tank), through filters and IX columns. The decontaminated salt solution is transferred to Tank 11 (receipt tank), and on to Tank 50H for final disposal in the Saltstone Production Facility. The current TCCR can accommodate lead-lag (two-column) or lead-lag-guard (three-column) configurations to optimize media utilization and achieve the target decontamination. To assist the TCCR operations, a parametric study was conducted to evaluate the impact of different parameters (e.g., column configurations (single column, two columns or three columns in series), waste characteristics, operating temperature, process flow rate, CST average particle size) on the IX column performance including CST bed utilization. The initial results indicate that the IX column performance is improved at slower process flow rate, at lower operating temperature, and with smaller CST average particle size. Multi-column configurations are recommended, because the single-column configuration does not utilize CST bed effectively. This paper demonstrates the versatility of the ion exchange modeling to evaluate the effects of CST characteristics and operational parameters on IX column performances. (authors)