Search NASA⌕ Search

SEARCH · Search NASA

Results for “charging inlet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

A review of NLR's work in charging system reliability for charging inlets, connectors, and adapters. The review includes a detailed discussion on (a) the development of a reference device for the thermal performance of charging connectors and adapters, (b) evaluation of charging adapters and their thermal warning and shutdown response, (c) implications of side-load from real-world implementations, and (d) strengthening the conformance evaluation for end caps based on field data.

33 ADVANCED PROPULSION SYSTEMS↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.

stratification↗

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

It is important for manufacturers of electric vehicle charging connectors, inlets, and adapters to understand the thermal performance of their devices. Various standards, such as SAE J1772, SAE J3400, IEC 62196, UL 2251, and UL 2252, list temperature limits that charging hardware needs to meet. However, there are currently very limited standardized reference devices against which to measure connector performance, and those that do currently exist generally serve charging currents less than 500A. This can make determining whether a charging connector meets the appropriate temperature limits difficult. Additionally, as automakers and charging station suppliers transition from the SAE J1772 CCS charging standard to SAE J3400 NACS, a number of CCS-to-NACS and NACS-to-CCS adapters are entering the market. These devices are being produced both by well-known automakers/equipment OEMs and lesser-known third-party suppliers, across a wide range of price points and construction qualities. Though SAE J3400/1 and UL 2252 lay out standards for adapter construction, performance and overtemperature response, there is no guarantee that any particular adapter will follow these standards and react to overtemperature events appropriately. This work addresses these issues by developing and evaluating a set of CCS and NACS reference inlet devices to validate the performance of charging connectors in the 500-800A range. The work also evaluates the performance of multiple NACS-to-CCS and CCS-to-NACS charging adapters with respect to UL 2252 temperature limits and SAE J3400/1 overtemperature signaling criteria.

33 ADVANCED PROPULSION SYSTEMS↗

Pull Force Evaluation of CCS Insulated End Caps

Insulated end caps installed on DC pins of Combined Charging System (CCS) inlets have been identified as potential debris sources within electric vehicle supply equipment (EVSE) connectors, increasing the risk of electric shock and fire hazards. Although standards such as IEC 62196-1:2022 specify mechanical pull-force requirements for these end caps, it remains unclear whether these requirements provide adequate robustness under real-world conditions. To address this concern, the National Charging Experience (ChargeX) Consortium's Hardware Task Force conducted evaluations of insulated end caps used in OEM CCS inlets. This study assesses the performance of insulated end caps used in OEM CCS inlets, specifically those installed on DC pins, using the procedures defined in IEC 62196-1:2022 (Section Sign) 26.7 and SAE J3400, supplemented by additional experimental conditioning. To ensure relevance to real-world conditions, NLR collaborated with charging network operators (CNOs) to guide the selection of charging inlet samples. Material analyses of the insulated end cap samples were conducted to confirm that the tested materials reflected the types and properties commonly observed in the field. The selected samples underwent temperature and humidity conditioning followed by pull-force testing to evaluate the end-cap integrity. Although SAE J3400 inlets were not directly tested due to limited diversity in available field data, the underlying end-cap principles between CCS and SAE J3400 are comparable, allowing the study's insights to be relevant to both technologies. Overall, this study provides a structured evaluation framework to inform potential refinements to mechanical pull-force requirements in charging standards.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗

CharIN Megawatt Charging System: 4 th Event Summary Report

Medium- and heavy-duty electric vehicles require higher charging power levels than are supported by present light-duty EV charging standards. The Charging Interface Initiative (CharIN) Megawatt Charging System (MCS) Task Force is undertaking efforts to develop a new high-power charging standard for medium- and heavy-duty vehicle electrification. The fourth MCS evaluation event at NREL focused on thermal and mechanical performance evaluations of high-power MCS electric vehicle charging connectors and inlets from several different manufacturers, at current levels up to 3000A. Additionally, the event evaluated the performance of a reference inlet design, which will provide a baseline level of thermal performance for use in future evaluation and certification efforts of MCS connectors.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Recommended Actions to Improve Adapter Safety

With the rapid advancement and acceleration in the electric vehicle (EV) industry within the United States, major automakers and EV charging companies are increasingly adopting the North American Charging Standard (NACS) connector style, now officially known as J3400. This shift is expected to enhance charging infrastructure, providing a better customer experience by making it easier for all EV drivers to access a wider network of direct-current (DC) fast chargers (DCFCs). However, the adoption of the J3400 standard presents challenges for many EVs already on the roads and some currently coming off production lines that are equipped with the Combined Charging System (CCS) connector, which this report will refer to as the North American standard, CCS1. These vehicles will need adapters to use new or existing J3400 infrastructure. During this transition, several issues have emerged. Firstly, there is a need to standardize the new connector type to ensure it is interoperable, safe, and reliable. Second, existing CCS EV drivers need a way to access the J3400 network, which will require electric vehicle supply equipment (EVSE) or sites with both connector types, driver-provided adapters to physically convert from CCS to J3400, or EVSE with retained adapters designed for use with the EVSE. Third, adapter standards will need to be written to specify how they will be designed and what evaluations will be needed to ensure safe and reliable performance. To address these challenges, adapters that support different types of charging connectors will be essential. These adapters will play a crucial role in supporting the transition and ensuring continued service for legacy EVs with CCS inlets as the J3400 standard becomes the predominant one in the United States. Consequently, the National Charging Experience (ChargeX) Consortium has investigated and performed a teardown analysis on the different adapter versions on the market. The aim is to create a failure mode and effects analysis (FMEA) on what are expected to be the most common adapter types used in this transition. In order to support this work, we executed an FMEA exercise with the main goal of identifying gaps in the existing adapters' performance and conformance to the most common safety requirements of high-power and high-voltage devices. This effort focused on adapters provided by the driver, as these may present the highest safety and reliability risks. The recommendations made here apply to both retained and driver-provided adapters.

25 ENERGY STORAGE↗

Reliability of Open Public Electric Vehicle Direct Current Fast Chargers

The aim was to systematically evaluate the usability of all public electric vehicles (EV) direct current fast chargers (DCFC) in the San Francisco region. To achieve a rapid transition to EVs, a highly reliable and easy to use charging infrastructure is critical to building confidence among consumers. The functionality and usability of all 182 open, public DCFC charging stations with CCS connectors (combined charging system) in the 9 counties of the Bay Area were tested (655 electric vehicle service equipment (EVSE) ports). An EVSE was classified as functional if it charged an EV for 2 minutes. Overall, 73.3% of the 655 EVSEs were functional. The causes of the nonfunctioning EVSEs (23.5%) were blank or unresponsive screens or error messages; payment system failures; charge initiation failures; network failures; or broken connectors. In addition, the cable was too short to reach the EV inlet for 3.2% of the EVSEs. A random sampling of 10% of the EVSEs, approximately 8 days after the first evaluation, found no overall change in functionality. The level of functionality found with field testing conflicts with the 95–98% uptime reported by the EV service providers (EVSPs) who operate the EV charging stations. There is a need for precise and verifiable definitions of uptime, downtime, and excluded time, as applied to public EV chargers. In conclusion, the level of failure of the existing public EV DCFC charge infrastructure highlights the importance of improving the system design and maintenance to improve adoption of EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling of Combined Lead Fast Reactor and Concentrating Solar Power Supercritical Carbon Dioxide Cycles to Demonstrate Feasibility, Efficiency Gains, and Cost Reductions

Solar power has innate issues with weather, grid demand and time of day, which can be mitigated through use of thermal energy storage for concentrating solar power (CSP). Nuclear reactors, including lead-cooled fast reactors (LFRs), can adjust power output according to demand; but with high fixed costs and low operating costs, there may not be sufficient economic incentive to make this worthwhile. We investigate potential synergies through coupling CSP and LFR together in a single supercritical CO 2 Brayton cycle and/or using the same thermal energy storage. Combining these cycles allows for the LFR to thermally charge the salt storage in the CSP cycle during low-demand periods to be dispatched when grid demand increases. The LFR/CSP coupling into one cycle is modeled to find the preferred location of the LFR heat exchanger, CSP heat exchanger, sCO 2 -to-salt heat exchanger (C2S), turbines, and recuperators within the supercritical CO 2 Brayton cycle. Three cycle configurations have been studied: two-cycle configuration, which uses CSP and LFR heat for dedicated turbocompressors, has the highest efficiencies but with less component synergies; a combined cycle with CSP and LFR heat sources in parallel is the simplest with the lowest efficiencies; and a combined cycle with separate high-temperature recuperators for both the CSP and LFR is a compromise between efficiency and component synergies. Additionally, four thermal energy storage charging techniques are studied: the turbine positioned before C2S, requiring a high LFR outlet temperature for viability; the turbine after the C2S, reducing turbine inlet temperature and therefore power; the turbine parallel to the C2S producing moderate efficiency; and a dedicated circulator loop. While all configurations have pros and cons, use of a single cycle offers component synergies with limited efficiency penalty. Using a turbine in parallel with the C2S heat exchanger is feasible but results in a low charging efficiency, while a dedicated circulator loop offers flexibility and near-perfect heat storage efficiency but increasing cost with additional cycle components.

14 SOLAR ENERGY↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Spark-ignited direct-injection engine combustion systems

A direct-injection stratified charge internal combustion engine includes a combustion cylinder to receive an air-fuel mixture, and an air intake port to inlet air into the combustion cylinder. The direct-injection engine also includes a fuel injector configured to deliver fuel within the cylinder in a spray pattern substantially aligned to a cylinder central axis to create the air-fuel mixture. A spark igniter is located within a path of the spray pattern to ignite combustion of the air-fuel mixture. The direct-injection engine further includes a movable piston defining a lower boundary of the combustion cylinder to contain the combustion of the air-fuel mixture. The piston is configured to include a bowl portion having local geometric features located on an intake port side of the combustion cylinder to redirect fluid flow towards a vortex in fluid communication with a combustion location near the cylinder central axis.

42 ENGINEERING↗

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗