Safety Analysis of Chromium-Coated Accident-Tolerant Fuels with Increased Enrichment and Extended Burnup [Slides]

This report documents research and development conducted in support of deployment of accident-tolerant fuels. Specifically, the performance of chromium coating during a beyond design basis accident was investigated. An 18m reference core was considered, and the performance of cases with and without chromium coating compared. An extended cycle length of 24m was then considered with the chromium coating, to determine if the benefit of using the chromium coating was more or less significant than the increased fission product inventory when considering fission product release. The chromium coating model utilized here is a preliminary implementation and further work is recommended on a more detailed model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Report on RIA Relevant Modified Burst Testing of ATF Cladding Materials

The mechanical performance of accident-tolerant fuel (ATF) cladding candidates in light-water reactors (LWRs) must be similar to or better than that of current conventional nuclear fuel claddings to reduce dose to the public and ensure a that the core coolable geometry is maintained during a postulated reactivity-initiated accident (RIA) in light-water reactors (LWRs). During an RIA event, the rapid thermal expansion of nuclear fuel can deform the cladding once the fuel–cladding gap closes. In some cases, the pellet–cladding mechanical interaction (PCMI) can induce mechanical failure in ATF candidates. Thus, the mechanical response of ATF cladding must be investigated by mimicking the conditions of RIA and potentially performing Transient Reactor Test (TREAT) experiments to establish or verify the safety envelope. The work presented in this report investigated the failure behavior of as-received, hydrided, and chromium-coated (Cr-coated) Zircaloy-4 (Zry-4) cladding tube under strain-driven mechanical conditions, mimicking postulated RIA loading conditions. Mechanical testing was performed at 300°C via modified burst test (MBT) equipment with pulse width control previously developed under the Department of Energy’s (DOE’s) Advanced Fuel Campaign (AFC). The mechanical strains were determined using 2D digital image correlation (DIC) techniques. The base Zry-4 acquired by Cameco Inc. was in stress-relieved annealed (SRA) condition. Because of the observed large deformation of the cladding tubes, the failure strain definition was updated for the MBT, which can also be applied to other tube tests where significant bulging (out-of-plane deformation) is present. The failure strain was determined to be affected by the speed of the test or the RIA event. As the RIA-like event duration decreased from 75 to 15 ms, the failure strain decreased 5, 7 and 1% for as-received, hydrided, and Cr-coated specimens, respectively. Fractography on the Cr-coated specimens indicated the presence of two failure mechanisms: (i) crenulation at the outer surface of the coating due to the tensile tractional forces along with coatings grain microstructure and (ii) formation of critical defect at the coating/cladding interface that initiated coating rupture after severe plastic deformation of the Zry- 4 substrate. Based on the MBT results and fractography observations, performing mechanical property testing at high strain rates—in particular on Cr-coated tubes—and semi-integral TREAT experiments are required future efforts to ensure ATF cladding performance during transients. The testing recommended would also inform the development of long-term generalized cladding technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cr-coated Accident Tolerant Fuel Concept Source Term Accident Sequence Analysis - High Burnup Fuel Source Term Accident Sequence Analysis Supplement

To extend NUREG-1465 and high burnup fuel source term (SAND2023-01313) recommendations, representative radiological releases to containment – patterned after NUREG-1465 – have been evaluated for LWRs utilizing the chromium-coating on major zircaloy structures (cladding and fuel canisters) and high burnup fuel with enrichments of 8% and 10% for PWRs and BWRs, respectively. Representative radionuclide releases are generated for this accident tolerant fuel concept by applying non-parametric bootstrap methods to MELCOR simulation results. Accident scenarios considered in this analysis include principle contributors to historical core damage frequency estimates for a range of nuclear reactor technologies representative of the operating U.S.A. fleet of nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ATF Cladding Mechanical Properties Report: Capability Demonstration

This report documents mechanical testing capability demonstration activities performed in fiscal year (FY)2025 at Oak Ridge National Laboratory(ORNL)on chromium-coated (Cr-coated) and uncoated advanced zirconium alloy claddings irradiated in the High Flux Isotope Reactor (HFIR) to approximately 4 displacements per atom (dpa), corresponding to ~13GWd/t burnup. Specimens were prepared in axial tension (ATT) and ring tension (RTT) geometries, and passive silicon carbide(SiC)thermometry (TM) was employed to determine irradiation temperatures, which averaged 38–43 °C below the 330 °C design target. Mechanical testing at ambient temperature demonstrated the expected irradiation-induced hardening, with yield strength(YS)and ultimate tensile strength(UTS)values increasing substantially relative to unirradiated counterparts. However, this strengthening was accompanied by a reduction in ductility, as indicated by lower uniform and total elongations(UE and TE). Both coated and uncoated claddings exhibited similar mechanical response, though Cr-coated specimens showed surface cracking perpendicular to the loading direction, attributable to the hardness mismatch between the coating and substrate. Fracture in all cases remained ductile, and no coating spallation was observed following HFIR irradiation. Complementary efforts were directed toward the fabrication of test specimens from commercially irradiated cladding (rod 47I, ~31.1 GWd/t average burnup). Axial sectioning and computer numerical control(CNC)machining successfully produced ATT geometries suitable for benchmarking against HFIR-irradiated specimens. This capability enables direct comparison of cladding behavior between test reactor and commercial reactor environments, thereby supporting the validation of HFIR as a surrogate irradiation platform for accident tolerant fuel (ATF) development. Once HFIR irradiations are completed in FY26,the relevant comparison tests will be completed. Collectively, the FY 2025 PIE campaign has provided mechanical performance data for irradiated advanced claddings The demonstrated capabilities support the framework for mechanical testing and further evaluations in subsequent years. These efforts will represent an important contribution toward the licensing and deployment of Cr-coated zirconium alloy cladding as a near-term ATF solution.

36 MATERIALS SCIENCE↗

ATF Cladding Mechanical Properties Report: Capability Demonstration

This report documents post-irradiation examination (PIE) activities performed in FY 2025 at Oak Ridge National Laboratory on chromium-coated (Cr-coated) and uncoated advanced zirconium alloy claddings irradiated in the High Flux Isotope Reactor (HFIR) to approximately 4 displacements per atom (dpa), corresponding to ~40 GWd/t burnup. Specimens were prepared in axial tension (ATT) and ring tension (RTT) geometries, and passive silicon carbide thermometry was employed to determine irradiation temperatures, which averaged 38–43 °C below the 330 °C design target.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PIE-Enabled Study of Aqueous Corrosion & Zr Hydriding in Cr-Coated Cladding: M3GV-23PN0101132

Chromium-coated zirconium alloy cladding is under investigation as an accident-tolerant fuel (ATF) concept to extend performance to higher burnups via improved oxidation resistance and reduced hydrogen pickup. However, hydrothermal corrosion behavior and hydrogen transport mechanisms governing in-service hydriding of these coatings remain poorly understood. In a collaborative study between Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and the University of Huddersfield, cold spray (CS) and physical vapor deposition (PVD) Cr-coated Optimized ZIRLO™ cladding samples were characterized after exposure to PWR-simulated water chemistry under both in-core (neutron irradiation) and out-of-core (aqueous-only) conditions at the MIT Research Reactor. Multi-scale characterization was performed independently at PNNL and INL to evaluate coating integrity, microstructural evolution, Cr/Zr interface chemistry, and hydride formation. Both laboratories observed a consistent divergence in hydriding behavior: out-of-core CS Cr-coated cladding exhibited elevated hydride concentrations exceeding those of uncoated cladding, whereas in-core CS samples showed substantially suppressed hydriding. In-core specimens also displayed irradiation-specific features, including nanoscale voids within the Cr coating and radiation-induced segregation clusters in the Zr substrate. CS coatings retained an interdiffusion-free Cr/Zr bond with no intermetallic layer, whereas PVD coatings exhibited inferior quality with visible cracks and pores. An automated image-based hydride quantification method systematically overestimated bulk hydrogen content relative to inert gas fusion measurements, underscoring the need for standardized sample preparation and reference standards. Interpretation of hydride nucleation and growth is complicated by the open inner-diameter of the specimens, which provides additional hydrogen pathways. The results motivate further foundational studies to support predictive models of hydrothermal corrosion and hydrogen transport in unirradiated and irradiated Cr-coated cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical Response of Cr-Coated Zircaloy-4 Cladding to Pellet-Cladding Interactions

Chromium-coated zircaloy is a promising accident tolerant fuel (ATF) cladding design which can help mitigate high temperature oxidation. The mechanical response of the cladding during and after loading may be altered by the Cr coating throughout anticipated operational and accident occurrences such as a pellet-cladding interaction (PCI). In this work, the mechanical behavior of Cr-coated and uncoated cold worked stress-relieved (CWSR) Zircaloy-4 (Zry-4) cladding to PCI loading conditions are studied. Stress relaxation tests are performed on CWSR Zry-4 cladding using full-tube axial tension and internal pressurization to investigate mechanical anisotropy and rate-limiting deformation mechanisms of the uncoated Zry-4. These results are compared to internal pressure testing results of similar cladding with physical vapor deposition (PVD) Cr-coating to reveal how the Cr-coating affects the cladding mechanical response. Findings are discussed in the context of ATF cladding performance during operation and storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗