Development of a Converter-Based Transmission Line Emulator with Three-Phase Short-Circuit Fault Emulation Capability

A transmission line emulator has been developed to flexibly represent interconnected ac lines under normal operating conditions in a voltage source converter (VSC)-based power system emulation platform. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. Here, this paper proposes a model to realize a three-phase short-circuit fault emulation at different locations along a single transmission line or one of several parallel-connected transmission lines. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and the normal state. Experiment results verify the developed transmission line three-phase short-circuit fault emulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Fault Detection, Localization, and Tolerant Operation of Modular Multilevel Converters with an Insulated Gate Bipolar Transistor (IGBT) Open Circuit Fault

Reliability is one of the critical issues for a modular multilevel converter (MMC) since it consists of a large number of series-connected power electronics submodules (SMs). Here in this paper, a complete control strategy including fault detection, localization, and tolerant operation is proposed for the MMC under an insulated gate bipolar transistor (IGBT) open circuit fault. According to the output characteristics of the SM with the open-circuit fault of IGBT, a fault detection method based on the circulating current and output current observation is used. In order to further precisely locate the position of the faulty SM, a fault localization method based on the SM capacitor voltage observation is developed. After the faulty SM is isolated, the continuous operation of the converter is ensured by adopting the fault-tolerant strategy based on the use of redundant modules. To verify the proposed fault detection, fault localization, and fault-tolerant operation strategies, a 900 kVA MMC system under the conditions of an IGBT open circuit is developed in the Matlab/Simulink platform. The capabilities of rapid detection, precise positioning, and fault-tolerant operation of the investigated detection and control algorithms are also demonstrated.

42 ENGINEERING↗

Three-phase short-circuit fault implementation in converter based transmission line emulator

A hardware test-bed (HTB) has been developed to realize power system emulation by mimicking the system components with universal three-phase voltage source converters (VSCs). The VSC-based transmission line emulator has also been successfully developed to flexibly represent interconnected ac lines under normal operating conditions. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. This paper proposes a model to realize the three-phase short-circuit fault emulation within the emulated transmission line. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and normal state.

Zhang, Shuoting↗

Series and parallel arc-fault circuit interrupter tests.

While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by opening the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.

Johnson, Jay Dean↗

Single-Submodule Open-Circuit Fault Diagnosis for a Modular Multi-level Converter Using Artificial Intelligent-based Techniques

Modular multi-level converters (MMCs) are one of the promising topologies in recent years for medium or high voltage applications. They are considered as the next generation DC/AC converters for medium/high voltage (MV/HV) motor drive applications due to their transform-less structures, high efficiency and modularity. Reliability is one of the most important challenges in MMCs, since a large number of power switching devices are used and each of these devices can be considered as a potential failure point. It is significant to detect and locate the fault accurately and apply appropriate protections in a timely manner. This paper investigates the behavior of the failure submodules and healthy submodules and use artificial neural network (ANN) classification algorithms for singlesubmodule open-circuit fault diagnosis. The ANN algorithm is implemented in field programmable gate array (FPGA) and the ANN parameters training is completed offline in Matlab. Experimental results of the proposed fault diagnosis for a singlemodule open-circuit fault are presented in this paper.

artificial intelligent↗

Inverter Design with High Short-Circuit Fault Current Contribution to Enable Legacy Overcurrent Protection for Islanded Microgrids

The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.

Ferrari Maglia, Max↗

Theoretical Analysis and Experimental Validation of Flying-Capacitor Multilevel Converters Under Short-Circuit Fault Conditions

Addressing the increasing demand for high- efficiency and high-power-density converters, the flying-capacitor multilevel converter has shown itself as a promising topology. A key advantage of this topology is the reduced voltage rating of the switches, though also makes it vulnerable to device failure during short-circuit conditions. Despite large interest in fault-tolerant operation of these converters, alongside detailed descriptions of flying capacitor balancing, little research has focused on the converter short-circuit fault analysis, which may cause a switch failure if not properly designed for. Therefore, this work presents a comprehensive model describing the large- signal short-circuit switching behavior of a general N -level flying- capacitor multilevel converter. Highly simplified models used to predict the evolution of the switch current and voltage stress during the fault are proposed, targeted at practicing engineers for conservative design guidelines. These models are used to determine the critical time for remedial action of the converter before reaching some predefined maximum conditions. A 2-to-10- level fully-configurable flying-capacitor multilevel converter and a fault circuit hardware prototype are used to experimentally perform different short-circuit tests that show a good match to the measured behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

An Overview of Spread Spectrum Time Domain Reflectometry Responses to Photovoltaic Faults

Spread spectrum time domain reflectometry (SSTDR) is a broadband electrical reflectometry technique that has been used to detect and locate faults on live electrical systems, including photovoltaic systems. In this article, we evaluate the detectability and localizability from both existing literature and our own measurements using SSTDR of open-circuit faults, connection faults, short-circuit faults, ground faults, arc faults, shading faults, bypass diode faults, and accelerated degradation faults in PV cells and mini-modules. Additionally, reflection magnitudes for these faults are compared. Herein, preliminary data on buried and grounded PV cable along with arc fault detection are presented.

14 SOLAR ENERGY↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Power Delivery Testing Feasibility Study (Task 6 Final Report)

This Final Report is covers the completion of the Electric Power Delivery Testing Feasibility Study. The objective of this project was to research, engineer, and demonstrate high-power laboratory testing protocols to accurately reproduce the conditions on the electric power grid representing both normal load switching and abnormalities such as short-circuit fault protection. Test circuits, equipment, and techniques were developed and proven at reduced power levels to determine the feasibility of building a large-scale high-power testing laboratory capable of testing equipment and systems at simulated high-power conditions of the U.S. power grid at distribution levels up through 38 kiloVolts (kV) and transmission levels up through 230 kV. The project delivered demonstrated testing techniques, high-voltage test equipment for load testing and synthetic short-circuit testing, and recommended designs for future implementation of a high-power testing laboratory to test equipment and systems, enabling increased reliability of the electric transmission and distribution grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Open-circuit submodule fault diagnosis in MMCs using support vector machines

Series connection of semiconductor submodules (SM) in a modular multilevel converter (MMC) makes the MMC prone to open-circuit (OC) IGBT failures inside SMs. If left undetected, these faults degrade the operation of the MMC and lead to its instability. This article proposes a method to detect, localise, and classify single OC SM faults in an MMC using support vector machines (SVM) trained with data obtained from the capacitor voltage balancing block of the MMC control system. The proposed method relies on data extracted from the sorted capacitor voltage arrays of the upper and lower phase arms. Therefore, it does not require extra measurements and hardware. Additionally, it offers a fixed time for detecting and localising OC SM faults. This method is easy to implement as SVM has a simple decision function. Time-domain simulation case studies are performed on a three-phase nine-level MMC to evaluate the performance of the proposed method.

42 ENGINEERING↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗