Search NASA⌕ Search

SEARCH · Search NASA

Results for “coded aperture imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗

H420 Imager Calibration Procedure: Field of View Scan

Gamma-ray imagers with coded apertures have a finite field of view (FOV) within which an image of a source can be generated. A “FOV scan” is a facet of imager calibration procedure that involves collecting specialized data for a range of source locations filling the FOV in order to understand and correct for differences in imager performance. Systematic distortions reveal relative displacements between internal imager components, which can be accounted for in data analysis. The success of this scan requires a stable imager position during the full measurement duration (~hours). This document summarizes the hardware and software tools required to conduct a FOV calibration scan of an H3D H420 Coded Aperture Gamma-Ray Imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A coded aperture with sub-mean-free-path thickness for implosion geometry imaging on ICF and IFE experiments

Inertial confinement fusion and inertial fusion energy experiments diagnose the geometry of the fusion region through imaging of the neutrons released through fusion reactions. Pinhole arrays typically used for such imaging require thick substrates to obtain high contrast along with a small pinhole diameter to obtain high resolution capability, resulting in pinholes that have large aspect ratios. This leads to expensive pinhole arrays that have small solid angles and are difficult to align. Here, we propose a coded aperture with scatter and partial attenuation (CASPA) for fusion neutron imaging that relaxes the thick substrate requirement for good image contrast. These coded apertures are expected to scale to larger solid angles and are easier to align without sacrificing imaging resolution or throughput. We use Monte Carlo simulations (Geant4) to explore a coded aperture design to measure neutron implosion asymmetries on fusion experiments at the National Ignition Facility (NIF) and discuss the viability of this technique, matching the current nominal resolution of 10 µm. The results show that a 10 mm thick tungsten CASPA can image NIF implosions with neutron yields above 10 14 with quality comparable to unprocessed data from a current NIF neutron imaging aperture. Furthermore, this CASPA substrate is 20 times thinner than the current aperture arrays for fusion neutron imaging and less than one mean free-path of 14.1 MeV neutrons through the substrate. Since the resolution, solid angle, and throughput are decoupled in coded aperture imaging, the resolution and solid angle achievable with future designs will be limited primarily by manufacturing capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital autofocusing of a coded-aperture Laue diffraction microscope

To provide optimal depth resolution with a coded-aperture Laue diffraction microscope, an accurate position of the coded-aperture and its scanning geometry need to be known. However, finding the geometry by trial and error is a time-consuming and often challenging process because of the large number of parameters involved. In this paper, we propose an optimization approach to automate the focusing process after data is collected. Here we demonstrate the robustness and efficiency of the proposed approach with experimental data taken at a synchrotron facility.

47 OTHER INSTRUMENTATION↗

Expected Gamma-Ray Burst Detection Rates and Redshift Distributions for the BlackCAT CubeSat Mission

We report the results of an extensive set of simulations exploring the sensitivity of the BlackCAT CubeSat to long-duration gamma-ray bursts (GRBs). BlackCAT is a NASA APRA-funded CubeSat mission for the detection and real-time subarcminute localization of high-redshift (z ≳ 3.5) GRBs. Thanks to their luminous and long-lived afterglow emissions, GRBs are uniquely valuable probes of high-redshift star-forming galaxies and the intergalactic medium. In addition, each detected GRB with a known redshift serves to localize a region of high-redshift star formation in three dimensions, enabling deep follow-on searches for host galaxies and associated local and large-scale structures. We explore two distinct models for the GRB redshift distribution and luminosity function, both consistent with Swift observations. We find that, for either model, BlackCAT is expected to detect a mean of 42 bursts per year on orbit, with 6.7% to 10% of these at z > 3.5. BlackCAT bursts will be localized to an r 90 ≲ 55'' precision and reported to the community within seconds. Due to the mission orbit and pointing scheme, bursts will be located in the night sky and well placed for deep multiwavelength follow-up observations. BlackCAT is on schedule to achieve launch readiness in 2025.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-Ray Imaging to Monitor Accumulating Holdup

Over time, nuclear materials can accumulate in process equipment and keeping track of such material is of interest to many stakeholder communities including safeguards, process monitoring, criticality safety, and radiological safety. Passive gamma-ray imaging provides a visual and quantitative tool that can be applied to this problem, allowing one to determine the amount of material present from the images. In this work we emulate the accumulation of highly enriched uranium (HEU) in a large rectangular stainless-steel duct by stacking 5, 27 × 50 cm2 cards, each of which has approximately 11 g of 235U in oxide form distributed across its surface, behind each other. A series of images were collected using a coded-aperture gamma-ray imager, starting with a single card, adding a second card, etc. Long integrations were collected to allow evaluating the performance of the approach as a function of integration time. The images are analyzed using first principles to determine the amount of material in each image. The results are compared to the known amount of material in each configuration, and as a function of time. The analysis includes a first-principles error propagation and to further evaluate the uncertainty, a boot-strap sampling approach is also applied to the data. The work offers a proof of concept for unattended monitoring of uranium holdup with a quantitative gamma-ray imaging technique.

Ziock, Klaus-Peter↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗