Search NASA⌕ Search

SEARCH · Search NASA

Results for “common mode current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Common Mode Current Challenges and Opportunities in Electric Powertrain Testing

During the development of novel electric powertrain (EP) components key parameters may be evaluated by test before a fully integrated EMI design is implemented. However, insufficiently mitigated EMI could impact the test equipment and test measurements. This risk is particularly valid with high voltage wide bandgap switching converters which enable high efficiency but can increase the EMI source function producing high levels of common mode (CM) current. Test facility equipment may be susceptible to the CM current from these converters causing test delays or measurement errors. Characterization of the common mode EMI of a powertrain component by analysis and/or measurement and assessment of the test facility EMC design can reduce this risk to yield efficient tests and successful measurements.

electromagnetic interference↗

Hardware Demonstration: Radiated Emissions as a Function of Common Mode Current

This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.

Hardware Demonstration↗

Manufacturing Process Development of a Carbon Fiber Reinforced Polymer Composite Shaft for Electric Motors

Electric aircraft applications require electric motors with increased specific power and efficiency. Composite structural components in motors are a potential solution for reducing motor mass, reducing magnetic losses, and limiting undesired conduction paths for fault, electromagnetic interference, or common-mode currents. In this report, manufacturing trials for a high-speed carbon fiber reinforced polymer composite motor shaft are presented. Four prototype shafts were produced using a hybrid biaxial/triaxial fabric that was circumferentially wrapped onto an additively manufactured high-temperature washout mandrel. An additional traditional overbraid approach was also evaluated and shows promise for high-rate, high-performance parts using automated manufacturing. This paper discusses the shaft design, manufacturing methods explored, material selection, the manufacturing trials, and the lessons learned. The results of this manufacturing investigation show feasibility for manufacturing composite shafts for electric motors.

Electric moto shaft↗

Optically isolated logarithmic nanoammeter capable of floating to 5 kilovolts

A logarithmic current-measuring instrument was developed to measure plasma coupling currents at a common mode voltage of 5 kilovolts. Positive or negative currents can be measured from 10 to the -9th power to .001 ampere direct current. Optical isolation is used to control input switching and to provide data referenced to ground potential. Analog meter readouts as well as zero to five volt outputs are provided for peripheral data collection. Six independent channels are provided. Three measure positive currents, and three measure negative currents. Although designed for vacuum operation, it can be used equally well in air to measure low currents at high common mode voltages.

Sturman, J. C.↗

LISA Technology Development at GSFC

The prime focus of LISA technology development efforts at NASA/GSFC has been in LISA interferometry, specifically in the area of laser frequency noise mitigation. Laser frequency noise is addressed through a combination of stabilization and common-mode rejection. Current plans call for two stages of stabilization, pre-stabilization to a local frequency reference and further stabilization using the constellation as a frequency reference. In order for these techniques to be used simultaneously, the pre-stabilization step must provide an adjustable frequency offset. Here, we report on a modification to the standard modulation/demodulation techniques used to stabilize to optical cavities that generates a frequency-tunable reference from a fixed-length cavity. This technique requires no modifications to the cavity itself and only minor modifications to the components. The measured noise performance and dynamic range of the laboratory prototype meets the LISA requirements.

Thorpe, James Ira↗

LISA Beyond Einstein: From the Big Bang to Black Holes. LISA Technology Development at GSFC

This viewgraph presentation reviews the work that has been ongoing at the Goddard Space Flight Center (GSFC) in the development of the technology to be used in the Laser Interferometer Space Antenna (LISA) spacecrafts. The prime focus of LISA technology development efforts at NASA/GSFC has been in LISA interferometry. Specifically efforts have been made in the area of laser frequency noise mitigation. Laser frequency noise is addressed through a combination of stabilization and common-mode rejection. Current plans call for two stages of stabilization, pre-stabilization to a local frequency reference and further stabilization using the constellation as a frequency reference. In order for these techniques to be used simultaneously, the pre-stabilization step must provide an adjustable frequency offset. This presentation reports on a modification to the standard modulation/demodulation technique used to stabilize to optical cavities that generates a frequency-tunable reference from a fixed length cavity. This technique requires no modifications to the cavity itself and only minor modifications to the components. The measured noise performance and dynamic range of the laboratory prototype meet the LISA requirements.

Thorpe, James Ira↗

Switching power supply filter

A filter for a switching power supply. The filter includes a common mode inductor with coil configurations allowing differential mode current from a dc source to pass through but attenuating common mode noise from the power supply so that the noise does not reach the dc source. The invention also includes the use of feed through capacitors at the switching power supply input terminals to provide further high-frequency noise attenuation.

Kumar, Prithvi R.↗

Performance of the THS4302 and the Class V Radiation-Tolerant THS4304-SP Silicon Germanium Wideband Amplifiers at Extreme Temperatures

This report discusses the performance of silicon germanium, wideband gain amplifiers under extreme temperatures. The investigated devices include Texas Instruments THS4304-SP and THS4302 amplifiers. Both chips are manufactured using the BiCom3 process based on silicon germanium technology along with silicon-on-insulator (SOI) buried oxide layers. The THS4304-SP device was chosen because it is a Class V radiation-tolerant (150 kRad, TID silicon), voltage-feedback operational amplifier designed for use in high-speed analog signal applications and is very desirable for NASA missions. It operates with a single 5 V power supply [1]. It comes in a 10-pin ceramic flatpack package, and it provides balanced inputs, low offset voltage and offset current, and high common mode rejection ratio. The fixed-gain THS4302 chip, which comes in a 16-pin leadless package, offers high bandwidth, high slew rate, low noise, and low distortion [2]. Such features have made the amplifier useful in a number of applications such as wideband signal processing, wireless transceivers, intermediate frequency (IF) amplifier, analog-to-digital converter (ADC) preamplifier, digital-to-analog converter (DAC) output buffer, measurement instrumentation, and medical and industrial imaging.

Patterson, Richard L.↗

Differential Current Source

Circuit acts as voltage-controlled current source having high-impedance floating differential output. Maintains commanded current in load, regardless of changes in load impedance and regardless of any common-mode voltages on load. Provides constant excitation current to germanium resistance thermometer or other transducer, output voltage of which sensed by differential voltage amplifier.

Sutton, John F.↗

Silicon Photonic Transceiver for Spacecraft Navigational Lidar

NASA is developing an entry, descent, and landing (EDL) lidar system, the Navigation Doppler Lidar (NDL), for high-precision landing on the Moon, Mars, and beyond. The current flight NDL systems use 1550 nm fiber-optic components for frequency-modulated continuous wave (FMCW) ranging beyond 5 km, but have reduced performance under vibrational and thermal stresses during EDL. Here we describe recent efforts to develop a breadboard silicon photonic optical transceiver for integration into NDL to reduce instrument size and improve robustness to environment and demonstrate the optical balanced receiver performance during testing with the breadboard NDL unit. Initial testing shows improved suppression of common mode noise by 25 dB over the current receiver, but a 10 dB reduction in signal to noise ratio (SNR) resulting from coupling losses from fiber to the on-chip waveguides. Future work will target reduced coupling loss, hermetic packaging, and co-integration of a single sideband suppressed carrier modulator into the same chip.

Photonic Integrated Circuits↗

Inexpensive pulse-train converter measures analog voltage

Converter measures small voltages or currents in presence of very large common-mode voltages (thousands of volts ac or dc). Advantages are low power consumption, transmission via single isolated channel, simplicity, and operation from single-polarity power supply.

Sturman, J. C.↗

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang↗

On modeling the common mode inductor

The common mode inductor is the corner stone of filter design. One of the most important parameters of performance is leakage inductance. The role of leakage inductance in filter performance and current handling is discussed. It is demonstrated that leakage inductance is, in fact, desirable. Underlying physics of operation for the common mode inductor is reviewed. A model is presented which enables the designer to predict the leakage inductance of the common mode choke.

Nave, Mark J.↗

Common Mode Conducted Emissions

This presentation provides an overview of common mode conducted emissions (CMCE) measurements on power and signal cables. The presentation focuses on how such measurements directly apply to electromagnetic compatibility at the system level and provides a discussion of different techniques for performing them correctly and accurately.

Current↗

Superconducting gravity gradiometer and a test of inverse square law

The equivalence principle prohibits the distinction of gravity from acceleration by a local measurement. However, by making a differential measurement of acceleration over a baseline, platform accelerations can be cancelled and gravity gradients detected. In an in-line superconducting gravity gradiometer, this differencing is accomplished with two spring-mass accelerometers in which the proof masses are confined to motion in a single degree of freedom and are coupled together by superconducting circuits. Platform motions appear as common mode accelerations and are cancelled by adjusting the ratio of two persistent currents in the sensing circuit. The sensing circuit is connected to a commercial SQUID amplifier to sense changes in the persistent currents generated by differential accelerations, i.e., gravity gradients. A three-axis gravity gradiometer is formed by mounting six accelerometers on the faces of a precision cube, with the accelerometers on opposite faces of the cube forming one of three in-line gradiometers. A dedicated satellite mission for mapping the earth's gravity field is an important one. Additional scientific goals are a test of the inverse square law to a part in 10(exp 10) at 100 km, and a test of the Lense-Thirring effect by detecting the relativistic gravity magnetic terms in the gravity gradient tensor for the earth.

Moody, M. V.↗

Phase detector for three-phase power factor controller

A phase detector for the three phase power factor controller (PFC) is described. The phase detector for each phase includes an operational amplifier which senses the current phase angle for that phase by sensing the voltage across the phase thyristor. Common mode rejection is achieved by providing positive feedback between the input and output of the voltage sensing operational amplifier. this feedback preferably comprises a resistor connected between the output and input of the operational amplifier. The novelty of the invention resides in providing positive feedback such that switching of the operational amplifier is synchronized with switching of the voltage across the thyristor. The invention provides a solution to problems associated with high common mode voltage and enables use of lower cost components than would be required by other approaches.

Nola, F. J.↗

Coupling Factor Determination in the Control of Unintentionally Generated RF Fields

Radiated emissions and susceptibility requirements imposed in bands where intentional RF reception or transmission does not occur is problematical. It is often desired to compare radiated emissions with radiated susceptibility performance to assess system level compatibility. For reasons purely theoretical and because of practical measurement limitations, this not realistic. McCollum and Clark proposed a limit and test method that provided a direct comparison of radiated emissions and radiated susceptibility performance in those cases where only unintentional emissions and reception are of interest (non-tunable electronics). This test method, referred to as bulk current emissions (BCE) testing, and its associated limit is a complementary test method to bulk current injection testing and radiated susceptibility testing. Previous work utilized victim and culprit circuits with low common-mode loop impedance. Forward work identified in this publication was to determine how different loop impedance on culprit and victim circuits affected cable-to-cable coupling and the corresponding BCE test limit. Cable coupling factors for victim and culprit circuits with different loop impedance are investigated.

McCollum, Matthew B.↗

The Transient Dendritic Solidification Experiment (TDSE)

Dendritic solidification is a common mode of solidification. It is also an important model problem in nonequilibrium physics and pattern formation physics. Current theories couple the transfer of latent heat with selection mechanisms at the interface. Measurements of succinonitrile (SCN) dendrites in microgravity show reasonable agreement between heat transfer predictions and experiment. However, data and analysis for assessing interfacial physics theories are less definitive. We are studying, and will present data on, transient effects in dendritic growth of SCN. We employ the Clapeyron pressure/melting temperature effect to make a rapid change in a sample's hydrostatic pressure, and thereby rapidly change the specimen's melting temperature, forcing the dendrite to select a new steady-state. These initial measurements show some surprising and non-intuitive effects.

Koss, M. B.↗